• Title/Summary/Keyword: 공진형 센서

Search Result 89, Processing Time 0.024 seconds

Design of Antenna for Intelligent Detection Sensor (지능형 주차검지센서용 안테나 개발)

  • Choi, Yoon-Seon;Hong, Ji-Hun;Woo, Jong-Myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.2
    • /
    • pp.104-109
    • /
    • 2020
  • In this paper, we proposed a miniaturized folded inverted F antenna with ISM-band (center frequency : 447 MHz) for mounting in intelligent parking sensor. First, to mount the antenna in the intelligent parking sensor module (72 mm × 70 mm) with limited size, a folded inverted F antenna was designed at low frequency 447 MHz (wavelength λ : 670 mm) of the ISM-band. As a result, it resonates in the ISM band and obtains suitable characteristic with a -10 dB bandwidth of 13 MHz (2.9%). In addition, the H-plane pattern by the vertical and horizontal elements represents the omni-directional patterns from which the null point is removed, and the E-plane has directivity in a specific direction. Finally, it is suitable as and antenna for vehicle management in parking lots.

Signal Detection and Control of Hemispherical Resonator Gyroscopes (반구형 공진 자이로스코프의 신호 검출 및 제어)

  • Hyun, Chul;Kang, Tae-Sam
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.204-210
    • /
    • 2012
  • In this paper, signal detection and control circuits for hemispherical resonator gyroscope(HRG) are designed, simulated and tested. HRG is one of the coriolis vibratory gyroscope(CVG) which has very stable quartz hemispherical resonator and shows very precise performance. HRG signals are usually modulated at the several kHz of resonant frequency. So the general control scheme cannot be applied directly because general control schemes mainly focused at low frequency range. Using demodulated and modulated PI control scheme with the signal detection which is presented in this paper, performance of manufactured HRG has tested.

Frequency Response Compensation Technique for Capacitive Microresonator (용량형 마이크로 공진기의 주파수 응답 보상 기법)

  • Seo, Jin-Deok;Lim, Kyo-Muk;Ko, Hyoung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.235-239
    • /
    • 2012
  • This paper presents frequency response compensation technique, and a self-oscillation circuit for capacitive microresonator with the compensation technique using programmable capacitor array, to compensate for the frequency response distorted by parasitic capacitances, and to obtain stable oscillation condition. The parasitic capacitances between the actuation input port and capacitive output port distort the frequency response of the microresonator. The distorted non-ideal frequency response can be compensated using two programmable capacitor arrays, which are connected between anti-phased actuation input port and capacitive output port. The simulation model includes the whole microresonator system, which consists of mechanical structure, transimpedance amplifier with automatic gain control, actuation driver and compensation circuit. The compensation operation and oscillation output of the system is verified with the simulation results.

High Sensitivity Analysis of Optical Bio-Sensor based on Grating-Assisted Strip Directional Coupler (격자 구조형 스트립 방향성 결합기에 기초한 광 바이오-센서의 고 민감도 분석)

  • Kwang-Chun Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.6
    • /
    • pp.157-162
    • /
    • 2023
  • A highly sensitive refractive index bio-sensor based on grating-assisted strip directional coupler (GASDC) is proposed. The sensor is designed using two asymmetric strip waveguides with a top-loaded grating structure in one of the waveguides. Maximum light couples from one waveguide to the other at the resonance wavelength satisfying phase-matching condition (PMC), and it shows that the change in phase-matching condition with the change in refractive index of the analyte medium in the cover region can be used as a measure of the sensitivity. The proposed sensor will be an on-chip device with a high refractive index sensitivity, and the sensor configuration offers a low propagation loss, thereby enhancing the sensitivity. Furthermore, variation of the sensitivity with the waveguide parameters of sensor is evaluated to optimize the design.

Analysis of Acoustic Reflectors for SAW Temperature Sensor and Wireless Measurement of Temperature (SAW 온도센서용 음향 반사판 분석 및 무선 온도 측정)

  • Kim, Ki-Bok;Kim, Seong-Hoon;Jeong, Jae-Kee;Shin, Beom-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.54-62
    • /
    • 2013
  • In this study, a wireless and non-power SAW (surface acoustic wave) temperature sensor was developed. The single inter-digital transducer (IDT) of SAW temperature sensor of which resonance frequency is 434 MHz was fabricated on $128^{\circ}$ rot-X $LiNbO_3$ piezoelectric substrate by semiconductor processing technology. To find optimal acoustic reflector for SAW temperature sensor, various kinds of acoustic reflectors were fabricated and their reflection characteristics were analyzed. The IDT type acoustic reflector showed better reflection characteristic than other reflectors. The wireless temperature sensing system consisting of SAW temperature sensor with dipole antenna and a microprocessor based control circuit with dipole antenna for transmitting signal to activate the SAW temperature sensor and receiving the signal from SAW temperature sensor was developed. The result with wireless SAW temperature sensing system showed that the frequency of SAW temperature sensor was linearly decreased with the increase of temperature in the range of 40 to $80^{\circ}C$ and the developed wireless SAW temperature sensing system showed the excellent performance with the coefficient of determination of 0.99.

An Underwater Acoustic Transducer Responding to Frequency Shift by Doppler Effect (도플러효과에 의한 주파수 변화에 대응하는 수중 초음파변환자의 제안)

  • Kim, Jung-Whan;Kim, Moo-Joon;Ha, Kang-Lyeol
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.16-23
    • /
    • 1999
  • When a moving piezoelectric transducer detects an object in water, its receiving sensitivity is attenuated by Doppler effect. In this paper, a method for compensating the effect is suggested by using a newly designed condenser of which capacitance is varied according to the moving speed of the transducer. Using the method, the receiving resonant frequency of the transducer can be changed automatically. As a result, there is good agreement between the results of experiment and those of calculation. It is confirmed that the response sensitivity degradation of transducers due to Doppler effect can be compensated in the range of $1{\sim}10^m/_s$ moving speed.

  • PDF

New transfer standard for low vacuum region

  • 우삼용;한승웅;김부식;이상균
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.44-44
    • /
    • 1999
  • 저진공(1 kPa~ 100 kPa)은 대기압 측정, 비행고도, 기체의 온도 측정, 질량의 부력 보정, 레이저의 굴절률 측정등에 사용되는 영역으로 과학적 중요성을 갖고 있다. 또한 대기압 이상의 압력 측정과 고진공 측정의 경계적 역할도 수행하고 있어 압력 표준기의 국제 비교에 필수적으로 권장되는 역역이다. 이 영역에 주로 사용되는 압력 표준기는 수은 압력계(Mercury manometer)와 분동식 압력계(Deadweight piston gauge or Pressure)가 있다. 이들은 이동이 불편하거나 불가능하므로 표준기의 국제 비교에 사용되는 전달 표준기로는 보다 이동이 간편한 탄성 압력계인 CDG(Capacitance diaphragm Gauge)가 있다. 이 게이지는 반도체 산업의 공정 제어용으로도 많이 사용되고 있다. 그러나 게이지와 함께 사용되는 컨트롤러의 부피가 크고 무거우며 영점 이동이 커서 측정때 마다 재조정하여야 하는 단점이 있다. 본 논문에서는 이 같은 단점을 극복하기 위해 수정빔 진동형 진공 센서를 잔달 표준기로 사용하는 것에 대한 연구를 수행하였다. 수정빔 진동형 압력 센서는 수정빔으 공진주파수가 스트레인에 비례하는 것을 이용하여 제작된 센서로 주로 대기압 이상의 고압 측정에 많이 사용되고 있다. 먼저 수정빔의 압력과 주파수간의 관계를 측정하고 또한 내장된 수정 온도센서의 공진 주파수를 측정하여 온도 보상을 위한 자료로 사용하였다. 규격에 나와 있는 수정빔의 기하학적 형상으로부터 거동에 관한 이론 모델식을 구하고 압력교정 자료로부터 얻어진 데이터를 이 식과 비교 분석하여 적합한 특성식과 인자를 구하였으며 게이지의 불확도를 추정하였다.모델은 길이가 유한한 0-차원 실린더 모델로 가정하였고, 이에 대한 기하학적 성질 및 열역학적 성질은 유효계수를 고려하여 산출하였다. 진공용기 이중 벽 내부로 흐르는 질소가스의 유량과 온도의 계산은 진공용기 내벽과 외벽을 각각 독립적인 열전달 요소로 가정하여 구성한 모델을 이용하였다. 전체 해석에서 각 열전달 요소의 비열 값은 온도에 따라 변화하는 비열의 특성을 반영하였으며. 진공용기와 플라즈마 대향 부품의 방사율(emissivity)은 앞서 가정했던 각 온도 상승 곡선에 대해서 각각 0.1, 0.2, 1.3의 경우를 가정하여 계산하였다. 직선적으로 증가하는 온도 상승 곡선중 2$0^{\circ}C$/hr의 온도상승율을 갖는 경우가 다른 베이킹 시나리오 모델에 비해 효과적이라 생각되며 초대 필요 공급열량은 200kW 정도로 산출되었다. 실질적인 수치를 얻기 위해 보다 고차원 모델로의 해석이 필요하리라 생각된다. 끝으로 장기적인 관점에서 KSTAR 장치의 베이킹 계획도 살펴본다.습파라미터와 더불어, 본 연구에서 새롭게 제시된 주기분할층의 파라미터들이 모형의 학습성과를 높이기 위해 함께 고려된다. 한편, 이러한 학습과정에서 추가적으로 고려해야 할 파라미터 갯수가 증가함에 따라서, 본 모델의 학습성과가 local minimum에 빠지는 문제점이 발생될 수 있다. 즉, 웨이블릿분석과 인공신경망모형을 모두 전역적으로 최적화시켜야 하는 문제가 발생한다. 본 연구에서는 이 문제를 해결하기 위해서, 최근 local minimum의 가능성을 최소화하여 전역적인 학습성과를 높여 주는 인공지능기법으로서 유전자알고리즘기법을 본 연구이 통합모델에 반영하였다. 이에 대한 실

  • PDF

Implementation of Analog Signal Processing ASIC for Vibratory Angular Velocity Detection Sensor (진동형 각속도 검출 센서를 위한 애널로그 신호처리 ASIC의 구현)

  • 김청월;이병렬;이상우;최준혁
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.4
    • /
    • pp.65-73
    • /
    • 2003
  • This paper presents the implementation of an analog signal-processing ASIS to detect an angular velocity signal from a vibrator angular velocity detection sensor. The output of the sensor to be charge appeared as the variation of the capacitance value in the structure of the sensor was detected using charge amplifiers and a self oscillation circuit for driving the sensor was implemented with a sinusoidal self oscillation circuit using the resonance characteristics of the sensor. Specially an automatic gain control circuit was utilized to prevent the deterioration of self-oscillation characteristics due to the external elements such as the characteristic variation of the sensor process and the temperature variation. The angular velocity signal, amplitude-mod)Hated in the operation characteristics of the sensor, was demodulated using a synchronous detection circuit. A switching multiplication circuit was used in the synchronous detection circuit to prevent the magnitude variation of detected signal caused by the amplitude variation of the carrier signal. The ASIC was designed and implemented using 0.5${\mu}{\textrm}{m}$ CMOS process. The chip size was 1.2mm x 1mm. In the experiment under the supply voltage of 3V, the ASIC consumed the supply current of 3.6mA and noise spectrum density from dc to 50Hz was in the range of -95 dBrms/√Hz and -100 dBrms/√Hz when the ASIC, coupled with the sensor, was in normal operation.

Deadbeat Controller Design of a ZCS-type Power Factor Correction Circuit(QBSRR) (ZCS형 역률 개선 회로(QBSRR)의 데드빗(deadbeat)제어기 설계)

  • 최현칠
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.107-117
    • /
    • 1998
  • In this paper, a deadbeat controller design technique is developed for the recently introduced PFC(Power Factor Correction) circuit named as a QBSRR(Quantum Boost Series Resonant Rectifier) to achieve the fast dynamic responses of the output voltage in the presense of any load variations. And, in order to monitor the load information without employing the current sensor, the load estimation method is also derived. By using the information of the load estimation method, the proposed controller gain is automatically adjusted to have the system always keep the very fast dynamic responses. To verify these superior performances, the simulation and the experiment are carried out.

Real-time Blood Pressure Monitoring in Porcine Tibial Artery Using LC Resonant Pressure Sensor (LC 공진형 압력 센서를 이용한 돼지 경골 동맥의 실시간 혈압 측정)

  • Choi, Won-Seok;Kim, Jin-Tae;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.445-450
    • /
    • 2012
  • We have developed an implantable wireless sensor for real time pressure monitoring of blood circulation system. MEMS (micro-electro-mechanical system) technology was adopted as a sensor development method. The sensor is composed of photolithographically patterned inductors and a distributed capacitor in gap between the inductors. A resulting LC resonant system produces its resonant frequency in range of 269 to 284 MHz at 740 mmHg. To read the resonant frequency changed by blood pressure variation, we developed a custom readout system based on a network analyzer functionality. The bench-top testing of the pressure sensors showed good mechanical and electrical functionality. A sensor was implanted into tibial artery of farm pig, and interrogated wirelessly with accurate readings of blood pressure. After 45 days, the sensor's electrical response and histopathology were studied with good frequency reading and biocompatibility.