사무공간의 통합유니트 구축을 위한 공조유니트 도출에 관한 연구 (Development of the Air-Conditioning Unit for Workspace Integrated Units)

  • 김지현;김선숙;양인호;김광우
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.669-680
    • /
    • 2005
  • The purpose of this study is to develop the air-conditioning unit combined with the lighting unit for workspace and to supply its performance data at architectural design stage. The air-conditioning unit is one of the components of a workspace integrated unit, which can be defined as the planning unit satisfying the environmental comfort criteria of workspace. Air-conditioning diffusers are classified according to throws and features by literature review and case study. Then diffusers are combined with the lighting unit. Through the CFD simulation, the thermal performance of each unit was evaluated and finally various air-conditioning units combined with the lighting units were developed.

사무공간의 통합유니트 구축에 관한 연구 (A Study on the Development of the Workspace Integrated Units)

  • 김선숙;이선우;김지현;양인호;김광우;김광우
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.704-713
    • /
    • 2005
  • The purpose of this study is to suggest the concept of an integrated unit and to develop integrated units considering the layout of luminaires and diffusers in workspace. An integrated unit can be defined as a planning unit which satisfies the environment comfort criteria of workspace. Integrating process of each unit was proposed by considering the current workspace planning process. Luminaire and diffuser types are classified by surveying the workspace of the domestic and foreign office buildings. Several lighting units and air-conditioning units were developed by visual and thermal simulation, and integrated units for various architectural module which satisfies the visual and thermal comfort criteria were drawn from those units.

수송용 DPH HVAC 히팅유니트장치의 열유동 시뮤레이션평가연구 (A Study on the Heat Transfer Characteristics of Heating Unit in DPH HVAC)

  • 노홍구;임경빈;노종호;이영기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.605-610
    • /
    • 2008
  • The study aims to analyzed and identify the heat transfer characteristics of heating unit for room using 3-D numerical-analysis in order to design heating unit. The temperature comparison processes were done with various numerical conditions. In addition, the optimal conditions of heating unit design were proposed as inlet temperature, the inlet flow, heater power, and vessel size.

  • PDF

칠드빔 유니트의 최적설계 및 성능평가 연구 (Study on Optimal Design and Performance Test of Chilled Beam Unit)

  • 김정엽;신현준;주상현;김지석
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.11-18
    • /
    • 2014
  • Chilled Beam system is the kind of water-air system which reduces the conveyance energy for air conditioning as well as allows efficient installation and comfortable indoor environment, and has been increasingly popular mainly in Europe. To effectively install such Chilled Beam system domestically, it is necessary to develop the product considering domestic climatic condition and the requirements for air conditioning system, and particularly the way to deal with condensation during operation of cooling system in summer shall be provided. In this study, the optimal design on induction structure of Chilled Beam unit was carried out through a numerical method, and the performance test for the prototype of unit was conducted in a real-scale experiment facilities of Chilled Beam unit. While the flowrate of 1st air is 101.3 CMH, the pressure in pressure chamber is 158.7 Pa and the cooling capacities of 1st air side and 2nd air side are 498.1 W and 709.5 W respectively.