• 제목/요약/키워드: 공조실

검색결과 62건 처리시간 0.023초

국내 종합병원 Utility Space의 체계 구축에 관한 연구 (A Study on the Systematic Construction of the Utility Space in General Hospital)

  • 김은석;양내원
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제23권4호
    • /
    • pp.77-84
    • /
    • 2017
  • Purpose: In terms of the flexibility in hospital architecture, there are fixed elements of hospital architecture: mechanical, electrical, aeration rooms and shafts, which are the main utility spaces. Thus, it is necessary to recognize the utility space as a system that helps internal functions and flexible internal changes. This study analyzes the notion of the main utility space in hospital architecture and the architectural planning features of the main utility spaces as the system in the design process of the recently built hospitals. Methods: The design factors are extracted comparing two hospitals' plans in each stage and the systematic characteristics of utility spaces are analyzed accordingly. The opinions gathered from interviews of practitioners, architects and facility planning experts directly involved in the architecture design process are analyzed and reflected in the results. Results: Planning for utility spaces should be accompanied by the architectural plan from the basic design process, and proceeded with recognizing utility spaces as a system, which is a fixed element. Utility spaces are highly organically connected. Horizontal and vertical distribution of air chambers can reduce the length and number of ducts, and thus save story height, and reduce the number of shafts, the vertical connection passage. This is advantageous in securing the variable area, which is the ultimate objective of the system-centered hospital architecture plan. Implications: Thereby aims to provide fundamental data on systematic utility space planning in the hospital architecture planning.

IoT 기반 흰점박이꽃무지 스마트 사육사 설계 및 성능평가 (Design and Performance Evaluation of the IoT-based Smart Breeding System for Protaetia Brevitarsis Seulensis)

  • 원진호;곽강수;노시영;이상규;최인찬;이재수;김태현;백정현;석영식
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2020년도 제62차 하계학술대회논문집 28권2호
    • /
    • pp.575-576
    • /
    • 2020
  • 본 논문은 근래에 식용곤충 식품에 대한 수요 및 국민적 관심이 증가하여 관련 산업이 급격히 성장하고 있는 가운데, 건강기능성 효과가 널리 알려진 흰점박이꽃무지 유충의 안정적인 생산량 확보를 위한 스마트 사육사를 제작하고 그 성능을 평가한 결과이다. 사육사는 L6m×W3m×H2.8m 크기로 제작하였으며, 안정적인 사육환경을 위하여 사육실과 공조실을 분리하여 설계하였다. 공시재료는 생후 15일이 경과된 흰점박이꽃 무지 유충 1령이며, 스마트 사육사 내 사육환경은 온도 25±2℃, 습도 65±5%로 제어하였다. 사육조사는 매주 1회, 유충의 체중, 길이, 두께를 측정하였으며, 스마트 사육사의 성능평가를 위해 일반 사육농가(전북 소재)와 비교·분석하였다. 사육 4주 후 조사 결과, 스마트 사육사에서 사육한 유충의 체중과 길이는 각각 평균 1.97g/마리와 3.75cm로, 일반농가의 1.58g/마리와 3.55cm에 비해 비교적 높은 것으로 나타났다. 하지만, 두께의 경우 2주 차까지 일반농가에서 대체로 높은 것으로 나타났으며, 이후 3~4주 차에서는 큰 차이를 보이지 않았다. 따라서 본 연구를 통해 개발한 흰점박이꽃무지 유충 스마트 사육사는 일반농가와 비교해 사육이 비교적 빠르고 생산량을 더 많이 확보할 수 있는 시스템으로 농가소득 증대에 유용할 것으로 판단되며, 장소 및 시간에 상관없이 생육환경 제어가 가능하여 개발된 시제품의 보급 확대가 필요하다.

  • PDF

원자력발전소 관할 소방관의 위험인식 개념도 연구 (Risk Perception of Fire Fighters Responsible for Nuclear Power Plants : A Concept Mapping Approach)

  • 최해연;이상규;김미경;최종안
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.141-149
    • /
    • 2018
  • 원전 관할 소방관의 위험인식은 업무 수행과 관련을 가지며, 재난대응의 준비 현황을 반영하기 때문에 체계적인 이해가 필요하다. 이에 본 연구는 원전 관할 소방관들의 고유한 위험인식의 구조와 내용을 개념도 방법으로 연구하였다. 원전 관할 소방관 18명이 아이디어 산출 단계에서 참여하였고, 원전 관할 소방관 15명이 진술문 구조화 단계에 참가하였다. 분석 결과, 원전 화재 대응에 대한 소방관들의 위험인식은 '두려움과 통제'와 '대응 자원' 두 차원을 중심으로 구조화되었다. 피폭에 대한 두려움과 낮은 통제, 통제와 권한 부족에 따른 불안, 공조와 신뢰의 부족, 권한제약 및 인력부족, 장비, 매뉴얼, 정보의 미비, 지식과 교육의 부족의 6개 범주가 위험인식의 주요 내용으로 도출되었다. 원전 화재에 대한 재난적 결과 기대와 대응자원의 부족에 따른 낮은 통제감이 위험인식을 높이는 주요 요소들로 확인되었다. 소방관들의 위험인식이 지니는 주요 특징들, 대응 역량과 대응자원을 포괄하는 복잡한 지식구조와 두려움과 신뢰 간의 밀접한 관련성 등에 관해 논의하였다.

칠드빔 유니트의 최적설계 및 성능평가 연구 (Study on Optimal Design and Performance Test of Chilled Beam Unit)

  • 김정엽;신현준;주상현;김지석
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.11-18
    • /
    • 2014
  • Chilled Beam system is the kind of water-air system which reduces the conveyance energy for air conditioning as well as allows efficient installation and comfortable indoor environment, and has been increasingly popular mainly in Europe. To effectively install such Chilled Beam system domestically, it is necessary to develop the product considering domestic climatic condition and the requirements for air conditioning system, and particularly the way to deal with condensation during operation of cooling system in summer shall be provided. In this study, the optimal design on induction structure of Chilled Beam unit was carried out through a numerical method, and the performance test for the prototype of unit was conducted in a real-scale experiment facilities of Chilled Beam unit. While the flowrate of 1st air is 101.3 CMH, the pressure in pressure chamber is 158.7 Pa and the cooling capacities of 1st air side and 2nd air side are 498.1 W and 709.5 W respectively.

PEMFC 시스템 효율 향상을 위한 열 관리 설비 개발 및 연구 (Development and Research of Thermal Management Equipment for Efficiency Enhancement of PEMFC Systems)

  • 김재환;이지승;강인석;주현철
    • 한국수소및신에너지학회논문집
    • /
    • 제35권2호
    • /
    • pp.205-215
    • /
    • 2024
  • This study introduced a direct contact heat exchanger to enhance the efficiency of polymer electrolyte membrane fuel cells (PEMFCs) systems. According to previous research, 28% of the operating costs of fuel cell systems are attributed to heat exchanger devices, prompting the design of a direct contact heat exchanger to address this issue. Optimal configurations were determined through computational fluid dynamics analysis and experimental device fabrication, and the enhanced heat exchange performance of the heat exchanger was experimentally confirmed. Through this, the contribution of the direct contact heat exchanger to the heat management and efficiency enhancement of PEMFC systems was established.

"황제내경(黃帝內徑)"에 나타난 음양상호관계론(陰陽相互關係論) 약고(略考) (Study On The Theory of The Interrelation of Yin and Yang in The Nei Ching)

  • 원종실
    • 동의생리병리학회지
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 2005
  • In Chinese philosophy, the concept of Yin and Yang, in the era of the Early China, applies to many more philosophical categories than merely the relationship between the sunny side and the shady side of the sun. A whole series of possible interactions between the Yin and Yang in life is contained in the Chinese Book of Changes, the I Ching. The philosophical theory and the origin of natural sciences of the I Ching is imbued in the Nei Ching. having absorbed and developed the essence of Book of Changes, the Nei Ching reflects the spirit of science. Under the influence of Book of Changes, as well as its idea of Yin and Yang, peculiar at the time, the Nei Ching adapts the essences of the theory of Yin and Yang. The contribution made by the Nei Ching to the development of the philosophical concepts of Yin and Yang lies in that it combines those philosophical concepts with medicine and makes this the basic theory of Chinese medicine. In the Nei Ching, the Yin and Yang theory asserts that the human body is an organic whole, and there exists an organic connection between all tissues and structures. Therefore, the Yin and Yang functions as an essential life that plays a major role of the organic interrelation, the mutual control, and the mutual assistance. Yet, at the same time, each of them can be divided into the opposite aspects of yin and yang. Yin and yang depend on each other for existence. Without yin, there would be no yang, Without yang, there would be no yin. Neither can exist in isolation. Thus the interrelation of Yin and Yang is premised on the two opposite forces and aspects as the underlying cause of all change of Yin and Yang.

실내 위치기반 서비스 구현을 위한 센서 시스템 개발 (Development of Sensor System for Indoor Location-Based Service Implementation)

  • 차주헌;이경호
    • 대한기계학회논문집A
    • /
    • 제36권11호
    • /
    • pp.1433-1439
    • /
    • 2012
  • 본 논문에서는 Building Energy Management System(BEMS) 구현을 위해 "재실자의 위치 및 인원정보" 에 기반을 둔 실내 위치 기반 서비스 및 그를 위한 센서 시스템에 대하여 제안한다. 본 논문에서 제안한 센서 시스템에는 열에너지 그 자체를 감지 할 수 있는 서모파일 센서와 비 접촉 방식으로 대상까지의 거리를 얻어낼 수 있는 초음파센서, 그리고 이를 제어하고 구동할 수 있는 기구 및 동작부가 포함된다. 본 시스템은 적절한 크기의 방 전체를 감시할 수 있도록, $360^{\circ}$ 회전과 틸팅이 가능한 구조로 되어있어, 실내공간내의 재실자의 인원 및 위치를 동시에 파악할 수 있다. 또한 무선통신 기술인 블루투스 모듈을 통해 빌딩 관리자나 스마트 홈 서버와의 통신이 가능하도록 되어 있어, 빌딩내의 조명이나 공조시스템을 자동으로 제어, 관리하게 함으로써 전체 에너지 절약을 가능케 한다. 마지막으로 측정 데이터 검증을 위한 실환경 실험을 통해, 본 연구에서 제안한 시스템의 효용성 및 타당성을 확인한다.

고밀도 데이터센터의 열환경제어를 위한 수치해석 (Numerical Analysis of Thermal Environment Control in High-Density Data Center)

  • 권오경;김현중;차동안
    • 대한기계학회논문집B
    • /
    • 제36권8호
    • /
    • pp.821-828
    • /
    • 2012
  • CPU의 발열량 증가는 서버를 통과하는 배출공기와 유입공기와의 상당한 온도차를 발생시키고 이로 인해 배출공기의 재순환 현상과 유입공기의 바이패스 현상이 발생한다. 이는 데이터센터 냉각시스템의 효율저하를 발생시킨다. 따라서 CRAC의 제어를 통해 유입공기와 배출공기를 분리하는 것이 데이터센터 냉각시스템의 중요한 목표이다. 본 연구에서는 CFD 해석 코드인 ICEPAK을 이용하여 데이터센터에 대한 수치해석을 진행하였다. 실내부로 유입되는 공기유량의 변화에 따른 CPU의 온도와 실 전체의 온도분포를 분석하였다. 이를 통해 CPU의 발열량에 따른 최적 유입유량을 선정하였다. CPU 발열량이 100, 120, 140 W인 경우 유입유량이 $0.15m^3/s$인 지점에서 발열제거와 온도분배가 가장 잘 이루어졌다. RTI 성능지표를 이용하여 해석결과를 검증하였고 RTI 값이 81인 경우 가장 안정적인 결과를 보였다.

다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구 (Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility)

  • 김태한;최부헌
    • 한국조경학회지
    • /
    • 제48권5호
    • /
    • pp.80-88
    • /
    • 2020
  • 2019년 3월 미세먼지 비상저감조치가 일주일 동안 발령되면서, 미세먼지로 인한 국민의 불안감은 점차 가중되고 있다. 본 연구는 공기정화식물이 적용된 바이오필터의 다중이용시설 내 적용성 평가를 위해 입자상 오염원의 실내 연속방출환경을 조성하여 오염원 저감효과에 대한 측정방법을 제안하고, 시스템의 실내공기질 개선 여부를 확인할 수 있는 기초연구를 진행하였다. 강의실을 대상으로 춘절기에 모니터링 1시간 전 모기향을 오염원으로 배경농도를 조성한 후, 스케줄에 따라 2시간 관수, 1시간 송풍하여 미세먼지의 저감능을 확인하였으며, 바이오필터 2m 전방에 PM10, PM2.5 및 온습도 센서를 설치하고, 3개 송풍구 중 중앙에 풍속 프로브를 설치하여 시계열 모니터링을 수행하였다. 바이오필터에 구비된 총 3개소의 송풍구 평균 면풍속은 0.38±0.16 m/s로 댐퍼 면적이 제외된 송풍구별 면적 0.29m×0.65m을 적용한 총 공조풍량이 776.89±320.16㎥/h로 산출되었다. 시스템 가동으로 평균온도 21.5~22.3℃, 평균상대습도 63.79~73.6%를 유지하여, 선행연구의 다양한 조건별 온습도 범위에 부합하는 것으로 판단된다. 시스템 공조부 구동을 통해 급격하게 상대습도를 상승시키는 효과를 효율적으로 운용할 경우, 계절에 따른 실내 미세먼지 저감과 적정한 상대습도 확보도 가능할 것으로 판단된다. 미세먼지 농도는 바이오필터 시스템 가동 전의 모든 주기에서 상승 현상이 동일하게 집계되었으며, 시스템 가동 후 1주기 송풍구간(B-1, β=-3.83, β=-2.45)에서 미세먼지(PM10)는 최대 28.8% 수준인 560.3㎍/㎥, 초미세 먼지(PM2.5)는 최대 28.0% 수준인 350.0㎍/㎥까지 저감되었다. 이후 미세먼지(PM10, PM2.5)의 농도는 2주기 송풍구간 감소(B-2, β=-5.50, β=-3.30)로 각각 최대 32.6% 수준인 647.0㎍/㎥, 32.4% 수준인 401.3㎍/㎥까지 저감되었고, 3주기 송풍구간감소(B-3, β=5.48, β=-3.51)로 최대 30.8% 수준인 732.7㎍/㎥, 31.0% 수준인 459.3㎍/㎥까지 저감된 것으로 확인되었다. 본 연구는 식생 바이오필터의 다중이용시설 내 설치와 유관한 관련 표준 및 규정을 참조하여, 객관적인 성능평가환경의 구축 방안을 제시할 수 있었다. 이를 통해 일반 강의실 환경 내에 보다 객관화된 모니터링 인프라를 조성하여, 상대적으로 신뢰성 있는 데이터 확보가 가능했던 것으로 판단된다.

EnergyPlus를 이용한 건물 부위별 목질제품 적용에 따른 건축물 에너지 절감 기여도 평가 (Evaluation and Analysis of The Building Energy Saving Performance by Component of Wood Products Using EnergyPlus)

  • 서정기;위승환;김수민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권5호
    • /
    • pp.655-663
    • /
    • 2016
  • 최근, 전 세계적으로 온실 가스 증가에 따른 기후 변화에 대한 문제가 논의되고 있다. 그중, 건축물에서의 에너지 소비량은 전체 에너지 소비량의 40%까지 증가할 것으로 예상된다. 따라서 건축물에서의 에너지 소비량 절감에 대한 노력이 필요한 실정이다. 본 연구에서는, 건물에너지 절감에 효과적으로 기여하는 재료 중 하나인 목재를 이용하여, 목질 제품 구성에 따른 중부지방과 남부지방의 난방에너지 요구량에 대하여 시뮬레이션을 통해 분석하였다. 시뮬레이션 도구는 미국 에너지부(Department of Energy)가 BLAST와 DOE-2의 장점을 결합해 만든 동적 에너지 해석 엔진인 EnergyPlus를 이용하였다. EnergyPlus는 다양한 건물 및 HVAC 시스템 구성요소(Object)에 대한 입력항목(Field)을 가지고 있으며, 특히 건물, 공조시스템, 열원기기 사이의 피드백을 통해 통합된 동시계산을 수행하며, ASHRAE Standard 140-2007 표준에 따라 상용 프로그램 간의 비교를 통해 검증된 프로그램이다. 시뮬레이션을 위한 기상데이터는 EnergyPlus에서 제공하는 IWEC 인천 지역과 광주 지역의 epw 형식 기상데이터를 이용하였다. 대상 모델은 한국농어촌공사에서 제시한 2012년 농 어촌주택 표준설계도면 중 '농림-12-26-가' 유형을 이용하였으며 총 10개의 실로 구성되어 있다. 시뮬레이션 분석 결과, 중부지방과 남부지방 별 목질 제품의 적용 범위를 실내마감재, 실외마감재, 창호, 목구조로 단계적으로 변경해 지역에 따라 각각 16 Case의 시뮬레이션을 수행한 결과 실내외의 마감재로 목재를 사용한 것만으로도 에너지 성능이 향상된 것을 확인할 수 있었다.