• Title/Summary/Keyword: 공조설비

Search Result 587, Processing Time 0.024 seconds

Performance evaluation of brazed aluminum heat exchangers for a condenser in residential air-conditioning applications (가정용 공조기의 응축기 적용 알루미늄 열교환기의 성능 평가)

  • 김만회;김권진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.44-55
    • /
    • 1998
  • The evaluation of aluminum flat tube and louver fin heat exchangers for a condenser in residential air-conditioning applications has been conducted. A series of tests for two-different brazed aluminum heat exchangers was performed and the results were compared with conventional fin and tube heat exchangers for residential air-conditioning system. Refrigerant charge amount for a window-system air-conditioner with the brazed aluminum condenser is decreased by 35% and the volume and material of heat exchanger can be reduced by 50% compared to the conventional fin and tube heat exchangers.

  • PDF

A Study of air Sterilization System in Personalized Office Using Simulation (시뮬레이션을 이용한 개별사무공간의 살균공조시스템 연구)

  • Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.353-360
    • /
    • 2010
  • Recently H1N1(swine flu) and SARS has been infected widely in the world; we have to care about germs and virus in indoor air environment. The air sterilization system investigated in this study allows occupants to turn on/off and to control the incoming air speed and direction. To predict the performance of air sterilization system without real experiment, a simulation is considered to compare and analyze the performance of the air sterilization systems in a typical office space. Multiple system parameters including volume flow rate and velocity of supply air were varied and investigated during the simulation. The investigation result shows that difference (between simulation and experiment) was about 3.5% in case of minimum air flow rate and about 0.2% in case of maximum air flow rate. The results indicate that multi-zone simulation technique can be used to predict the performance of a sterilization system in personalized office.

An Experimental Study on Thermal Storage Performance of an Air Conditioning System with Slab Thermal Storage (슬래브축열 공조시스템의 축열성능에 관한 실험적 연구)

  • Jung Jae-Hoon;Shin Young-Gy
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.427-435
    • /
    • 2005
  • This paper investigates the thermal storage performance of the office building which has adopted an air conditioning system with its slab structure as a regenerator. Four cases of the thermal storage performance experiment were conducted. Room air temperatures, floor slab temperatures, temperatures around the air conditioning unit were logged and analyzed. The load handling capacity of the air conditioning unit and the amount of heat stored in the slab were decided from those experiments. Several efficiencies were investigated to evaluate the performance of the thermal storage. The results concluded that the slab as a regenerator is very effective in cutting down peak loads of the office building.

Design of an Aquifer Thermal Energy Storage System(II) : Thermal Analysis (지하대수층을 이용한 축열시스템의 설계(II) : 열해석)

  • Lee, K.S.;Lee, T.H.;Song, Y.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.315-324
    • /
    • 1994
  • The energy recovery efficiency(ERE) of an aquifer thermal energy storage system was calculated using curvilinear coordinate. The results of the calculation were compared with the experimental results, and agreed within 11% of the discrepancy. The variation of ERE was investigated as a function of the underground water natural velocity, the amount of the stored energy, and period of the energy recovery. The slower the natural velocity and shorter the recovery period, the higher ERE was yielded. Also it was found that increase in the amount of energy storage yields higher ERE, and carries out less influential ERE to the natural velocity. Reiterative usage of the aquifer as a thermal storage tends to gradually increase ERE. The result of this study implements that the aquifer thermal energy storage system is suitable for large cooling/heating loads, such as district cooling/heating.

  • PDF

The optimal parameters in series-series counterflow chillers system within air conditioning (공조장치내의 직렬-직렬 대향류 냉각기에서 최적 변수)

  • Phu, Nguyen Minh;Hung, Bui Ngoc;Lee, Geun-Sik
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1332-1336
    • /
    • 2009
  • If water-chillers are arranged in series-series counterflow, compressor lift of each chiller will be decreased in comparison with water-chillers in parallel. That means that compressor power of the chillers in series will be lower than that of chillers in parallel. However, the pressure drop of the water flow through the chillers in series will increase, and thus increase the power of water pumps. This disadvantage will be made good by increasing the temperature difference of water flow through evaporator and condenser, but the water flow rates will decrease. This paper explores the optimal parameters in system of series-series counterflow for central chilled water plants such as the leaving chilled water temperature, the leaving condenser water temperature, condenser water flow rate and number of chillers in series.

  • PDF

An Experimental Study on the Deodorization Performance Enhancement of the Air Handling Unit Using a Nano-Silver Material (은나노 소재를 이용한 공조기의 탈취 성능 향상에 관한 실험적 연구)

  • Nam, Sang-Yeob;Kang, Byung-Ha;Song, Ji-Hyeon;Han, Sung
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.739-744
    • /
    • 2009
  • The filter has long been used in purification processes for indoor air quality. To determine the deodorization effect of several filter materials in a full-scale air-handling system, the present study has been carried out using a wind tunnel equipped with a heat exchanger and various filter materials, such as commercial fabric, activated carbon(AC) and silver nano-particles attached to activated carbon(Ag-AC). The experiment was conducted using an odor substance with ammonia, acetaldehyde, acetic acid. The results obtained indicate that odor substance is substantially decreased on the moisture condensation on the surface of the heat exchanger. The fabric filter has no effect for removal of odor substances. The deodorization efficiency is found to be approximately 7% in the AC filter, while the deodorization efficiency is increased up to 10% using the Ag-AC filter.

  • PDF

Desiccant Air Conditioning System market and Prospect (데시칸트 공조시장 및 전망)

  • Park, Seung-Tae;Chung, Kwang-Seop;Kim, Young-Il;Park, Jong-Il
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.230-235
    • /
    • 2009
  • The Desiccant air conditioning system has been designed as the industrial dehumidifier under the leadership of developed countries, considering CFC problems in 1990, indoor air quality(IAQ) and outdoor air intake rates. This could make the technical differences between them and us. Nowadays, domestic technology has been developed in some parts but there still remain many challenges to be managed. In this study, these tasks would be handled according to the desiccant air conditioning system market and prospects.

  • PDF

A study for a Performance analysis of Hybrid heat pump Air conditioning system (복합열원형 히트펌프 냉난방 시스템의 성능분석에 관한 연구)

  • Lim, Hyun-Mook;Park, Hee-Moon;Cho, Soo;Sung, Uk-Joo;Park, Jin-Hoon;Park, Tae-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1373-1378
    • /
    • 2009
  • This study is aiming comparison and analization between efficiency of hybride air conditioning system which uses low temperature water under dam and air and EHP(Electric Heat Pump). The experimental was carried out with air cooling tests for EHP system having 80HP and composition heat pump system. P-i diagram of both systems and COP was used to derive schemetic and calcuations. As results of the tests, hybride system has 1.4 time higher efficiency coefficient.

  • PDF

The Study on the Application of Heat Recovery Aluminium Heat Exchanger in HVAC System (배기열회수 알루미늄 열교환기의 공조시스템 적용에 관한 연구)

  • Park, Yong-Hyo;Kim, Dong-Gyu;Kim, Geun-Oh;Jung, Yong-Hwan;Kum, Jong-Soo;Jeong, Seok-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1272-1276
    • /
    • 2009
  • The purpose of this study is to introduce wasted heat recovery heat exchanger for different kind of material in HVAC systems in field. For the purpose of estimating the large volume rotary heat exchanger and cross flow plate heat exchanger in heat recovery ventilator.

  • PDF

A Basic Study on Control Algorithm for Car HVAC (승용차 공기조화 제어 알고리즘 기초연구)

  • Shin, Young-Gy
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.5
    • /
    • pp.275-281
    • /
    • 2010
  • Car HVAC is one of main factors influencing a potential customer's first impression. It should be fault-free, which requires the most stable control performance. So, the control algorithm consists of a proportional feedback only, not with an integral action needed for elimination of steady-state errors. To reduce the errors and make the response faster, feedforward algorithm based on predicted thermal load is added. To evaluate the performance, car HVAC is dynamically modelled and its control logic is simulated. The results shows that the proportional feedback leads to about $4^{\circ}C$ of steady-state error. When the feedback is combined with the feedforward algorithm and with a set value update based on disturbances, it predicts less than $1^{\circ}C$ of control error and improved thermal comfort.