• Title/Summary/Keyword: 공정 운영시간

Search Result 155, Processing Time 0.035 seconds

A Case Study on Chlorine Dioxide Usage at a Conventional Water Treatment Plant (기존 정수장 이산화염소 시범도입 사례연구)

  • Lee, Song-Hee;Lee, Byung-Doo;Kim, Jin-Keun;Seog, Kwon-Soo;Lee, Joung-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.115-119
    • /
    • 2005
  • As the regulations on DBPs are tightened, many water treatment plants (WTPs) in Korea have already introduced or will introduce enhanced coagulation, alternative disinfectants and advanced treatments such as ozonization and granular activated carbon to improve drinking water qualify. After a phenol leakage accident at the Nakdong-River in 1991, 26 WIPs in Korea introduced carbon dioxide generators, but there has been no accumulation of significant operating data. This research summarizes things that should be considered for the introduction of carbon dioxide disinfection process to WTPs based on one year operation data from A WTP that has had high concentration of DBP during a specific period in the summer. The removal efficiency of DBP was $30{\sim}40%$, but those of 2-MIB, Geosmin were less than 10%. The generation rate of $ClO_2$ by-products such as chlorite and chlorate were $70{\sim}100%$ of input dosage, but the ratios increased over time. At the same time, strong chlorine odors may be produced in the distribution system when $ClO_2$ was used with $Cl_2$ as a result of reaction between the chlorite and residual chlorine.

Development of End-of-Life Vehicle Optimum Dismantling System Using Simulation (시뮬레이션을 통한 폐자동차 최적 해체시스템 개발)

  • Yang, Dae-Gil;Lee, Hong-Chul
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12a
    • /
    • pp.353-356
    • /
    • 2011
  • 자동차 폐차사업자들은 대부분 소규모로 영세하게 운영되고 있으며, 비효율적인 폐차 프로세스로 인해 폐차 소유자는 물론 폐차처리장까지 불이익을 받고 있다. 이를 위한 폐차 시스템에 대한 연구가 국내외에서 활발히 진행되고 있다. 하지만 기존에 개발되어진 폐차 해체시스템의 경우는 국내 폐차업계에 적용하기에는 경제적, 실용적으로 현실성이 부족하다. 따라서 본 연구에서는 폐차에 대한 효율성 극대화와 범용성 확보를 위해 시뮬레이션을 통한 폐자동차 해체시스템을 개발하고자 한다. 시뮬레이션을 통한 폐차 해체시스템의 사용은 복잡한 공정 또는 시스템의 설계 및 운영결과에 대한 효율적 분석이 가능하며, 다양한 위치 및 작업내용을 변경시켜 여러 대안을 마련할 수 있고, 이에 대한 결과를 미리 알아봄으로써 적은 시간과 비용으로 현장상황에 맞는 적절한 시스템을 구축할 수 있게 해주는 장점이 있다. 또한 최적 해체경로 시스템의 적용으로 시스템의 효율을 향상시켰다. 개발되어질 시스템은 높은 범용성 및 유연성 확보로 국내 폐차 업계의 발전에 크게 이바지 할 것이다.

  • PDF

Application of Non-Thermal Plasma for the Simultaneous Removal of Odor and Sludge (무기악취와 슬러지 동시처리를 위한 저온플라즈마의 적용)

  • Hwang, Hyun-Jung;Ann, Hae-Young;Shin, Seung-Kyu;Song, Ji-Hyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.85-92
    • /
    • 2010
  • In this study, odorous compounds emitted from various wastewater treatment were treated with using the non-thermal plasma reaction, and the effluent gas from the plasma reactor was introduced to a waste sludge reactor to achieve simultaneous sludge reduction. Hydrogen sulfide, the model odorous compound, was removed at 70% using the plasma reaction, and greater than 99% removal efficiency was observed when treated by the sludge reactor. In addition, the sludge reactor showed a high efficiency of ozone removal. As ozone reacted with sludge, oxidation with organic matters took place, and total COD decreased by 50~60% and soluble COD increased gradually. As a result, the integrated process consisting of the non-thermal plasma and the sludge reactor can be successfully applied for the simultaneous treatment of malodorous gas and waste sludge.

An Implementation of Point of Production Management System using Wireless Network (무선 네트워크를 이용한 생산시점관리시스템)

  • Seo, Jeong Min;Song, Jeo;Lee, Sang Moon
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.07a
    • /
    • pp.399-400
    • /
    • 2013
  • POP(Point of Production) 시스템은 제조현장에서 발생되는 생산 정보를 실시간으로 수집, 분석하여 현장의 보고 체계를 정형화 시켜준다. 또한 실시간 분석 정보를 통행 생산 이후의 과정(품질관리, 유통, 판매, 생산계획 등)을 기획하고 관리하는데 많은 도움을 준다. 즉, 제조 환경 변화에 따른 생산 지휘 체계를 통제하는 운영 환경을 조성하여 생산성 향상에 크게 기여한다. 이는 특힝 단위 공정의 생산량, 공정의 정확한 측정과 그에 따른 소요시간을 감축하는 장점이 있다. 본 논문에서는 기존의 C/S환경이 아닌 무선인터넷을 이용한 POP시스템을 제시한다.

  • PDF

Decentralized Sewage System Coupling Mechanical Elements with Constructed Wetland (인공습지와 기계적 처리요소를 연계한 마을하수 처리기술의 개발)

  • Yi, Qitao;Kwon, Tae-Young;Park, Tong-So;Kim, Y.C.
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.891-893
    • /
    • 2009
  • 기계적인 요소와 자연적인 요소를 연계한 마을하수처리 실증플랜트의 가동후 공정별 수질분석 및 자료수집개시: 2008년 9월20일에 착수하여 1주에 1회 간격으로 현재까지 공정별 26회의 현장방문과 수질 조사를 실시하였다. 질산화 전환율은 70~80%로 훌륭하나 탈질은 탄소원 부족으로 저조하였다. 그 이유는 유기물질은 전처리 단계인 바이오필터에서 대부분 제거되었기 때문으로 참여기업과 협의하여 바이오 필터 체류시간 감축방안 수립하여 운영한 결과 탈질효율을 향상시킬 수 있었다. 유기물질 제거효율은 상시적으로 90% 이상의 제거효율 달성할 수 있었다.

  • PDF

Improvement of the Waste Refrigerator Pre-processing Line in Metropolitan Recycling Center using Simulation (시뮬레이션 기반 수도권 리사이클링 센터 폐냉장고 전처리 공정 개선)

  • Kim, Do Gyun;Kang, Min Koo;Choi, Jin Young;Park, Kiejin;Kong, Man-Sik
    • Journal of the Korea Society for Simulation
    • /
    • v.22 no.4
    • /
    • pp.129-138
    • /
    • 2013
  • This paper studies the improvement of a pre-processing line for waste refrigerators in a metropolitan recycling center(MRC). We performed ARENA modeling and simulation by using work analysis and time measurement on the current processing line. Combined this result with some practical experiences from workers, we generated 3 alternatives to improve the current line and evaluated them by using ARENA simulation. The final decision selected consists of changing 2-line process into 1-line and having a separate cell-line for collecting refrigerant. Currently, the result of this study was applied to MRC by improving cycle time, throughput, and space utilization compared to the previous one.

A Study on Operating Condition of Test-Bed Plant using Membrane filtration of D Water Treatment Plant in Gwang-Ju (D정수장 정밀여과막 실증플랜트의 최적 운전조건 연구)

  • Yang, Hyung-Jae;Yi, Seung-Hoon;Moon, Kyung-Ran
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.3
    • /
    • pp.155-163
    • /
    • 2017
  • Membrane filtration has become more popular in drinking water treatment recently, since the filtration can control not only particulate matters but also pathogenic microorganisms such as giardia and cryptosporidium very effectively. Pilot-scale ($120m^3/d$ of treatment capacity) and test-bed ($25,000m^3/d$ of treatment capacity) microfiltration experiments were conducted to find optimum operating mode and the critical flux. Optimum operating mode of pilot-test was assessed as inflow 1.0 min, filtration 36.5 min, air backwash 0.9 min, backwash 1.0 min and outflow 1.0 min with 50 LMH ($L/min{\cdot}m3^$) of critical flux. Critical Flux was calculated to be $50L/m^2-h$ (within TMP 0.5 bar) based on the increase formula of the transmembrane pressure difference according to the change of time at Flux 20, 40, 56 and 62 LMH in pilot operation. Chemical cleaning was first acid washed twice, and alkali washing was performed secondarily, and a recovery rate of 95% was obtained in the test-bed plant. The results of operating under these appropriate conditions are as follows. Turbidity of treated water were 0.028, 0.024, 0.026 and 0.028 NTU in spring, summer, autumn and winter time, respectively. Microfiltration has superior treatment capability and performance characteristics in removing suspended solids and colloidal materials, which are the main cause of turbidity and important carrier of metal elements, and it has shown great potential in being an economically substitute to traditional processes (sand filtration).

A Study on Adjustment of Operational Factor in A2O process (A2O공정 운전인자 조정에 대한 연구)

  • Yoo, Ho-Sik;Lee, Byonghi
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.3
    • /
    • pp.33-41
    • /
    • 2015
  • An alternative was investigated to maximize the treatment efficiency of wastewater treatment plant without large scale expansion. 79% of detention time was required for enough nitrogen control. As aeration time was extended, nitrification was processed, but opposite trend was seen in phosphorus. High concentration of $NO_3-N$ interrupted PAOs activity not to absorb phosphorus. An alternative was devised for selective use of anaerobic or anoxic zone. Trisection was suggested for alternative use of center room. The result was relatively successful. The concentration of phosphorus was reduced with reduction of nitrogen. Extended anaerobic condition seemed to stimulate denitrification. Valve connection of internal return from aeration tank will make it possible to use middle room alternatively. This method will be a good alternative for seasonal variation of water temperature.

Study on the efficient operation of the auditing systems in the government -supported research institutes (출연기관 감사업무 효율화 방안)

  • 이병민;윤석기
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 1998.05a
    • /
    • pp.11-11
    • /
    • 1998
  • 출연기관 감사업무 효율화 방안은 네가지 측면에서 정리하여 볼 수 있다. 첫째, 법률적 측면에서 보면 감사원법에서 출연금은 감사대상에 포함되어 있어 출연기관은 감사제도를 운영하게 되어있다. 둘째, 정책적 측면에서 국회에 의한 국정감사는 연 1 회 총 20일간에 걸쳐 수행되므로 시간적 제약과 함께 지속성, 일관성 있는 적절한 감사가 이루어지기 어려운 측면이 있다. 셋째, 행정적 측면에서의 필요성은 일반적으로 이공계 연구개발 업무를 수행하고 있는 과학기술부 산하의 출연연구소는 정부기관이나 지방자치단체 또는 보조금 지원 기관과는 그 성격이 완연히 다른 연구기관임으로 연구생산성 제고에 적합한, 기관 특설에 맞는 자체 규정의 보완이 필요하다. 마지막으로 사회문화적으로 감사업무는 능률우선주의보다는 서류체계 및 규제중심으로 편향되기 쉬운 특성이 있어 이에 대한 개선방안 노력이 매우 중요하다. 출연기관의 감사기능은 내부.외부감사에 의하여 수행되고 있으나, 감사(監査)의 핵심적 기능은 역시 출연기관 자체의 감사(監事)에 의하여 수행되며 성격상 공정성(Fairness), 객관성(Objectivity), 신뢰성(Reliability)의 확보가 필수적이다. 출연기관 감사제도의 개선방향은 합법성, 합목적성을 근거로 기관운영의 효율성을 제고시키는데 초점을 맞춘 감사제도로 개선되어야한다. 감사조직체계의 개선, 전문 교육의 실시, 동일업무의 기준 마련, 상급기관과의 역할분담 정립 등으로 감사업무의 질적수준 및 효율성을 제고해야 한다. 감사평가제도는 그동안 실시된 사항이 없으므로 긍정적인 측면과 부정적인 측면이 공존하므로 평가제도의 도입 및 적용에 대해서는 보다 심층적인 검토가 필요하다. $[$감사조직의 평가요소$]$ ■ 투입요소측면 - 감사인력 - 장비 및 고정자산 - 예산(년도별) - 정보수집관리 - 조직운영방식 -전통 및 관습 - 관계법령, 규정, 감사업무지침 ■ 산출요소측면 - 감사운영 실적 - 감사보고 실적 - 감사제도 개선 및 자체개혁 실적 - 기관운영 효율화 기여도 - 기관의 연구성과 및 업적 향상 기여도 - 경영관리 고도화 기여도 등의 항목설정이 가능 출연기관 감사업무의 효율화 방안으로 감사제도 개선의 기본방향, 감사조직 및 인력운영의 개선, 감사업무 운영체계의 개선 등을 중심으로 발전방향을 제시하였다. 그러나 여기에서 제시된 개선방안들을 추진하기 위해서는 전문인력을 보강하고 상부체계에서의 수용이 요구되므로 출연기관 권역에서만으로의 힘으로는 한계가 있을 것이며 무엇보다도 감사제도 변화의 필요성과 미래지향적인 환경이 조성되어야 할 것이다.

  • PDF

Development of the Program for Operating & Managing Digital Forest Cover Type Map Using SDE(Revision 1.0) (공간DB엔진(SDE)을 이용한 수치임상도 운영·관리 프로그램 개발(Revision 1.0))

  • You, Byung-Oh;Seo, Su-An;Ryu, Joo-Hyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.3
    • /
    • pp.1-10
    • /
    • 2011
  • This program was developed to operate and manage the massive digital forest cover type map using SDE(spatial database engine) in order to solve the problems of the analogue mapping system, mapping process and managing vast amounts of data. It was established the standardization process by performing the several functions of application related to the spatial DB search, mapping history and progress control, modification and inspection of the topology error, approval and reject of those maps. It can be possible to generate the effective mapping and distribute maps to the public service. It is expected that the results will be able to reduce time-cost.