• Title/Summary/Keyword: 공비

Search Result 113, Processing Time 0.026 seconds

Acquisition of Direct-Sequence Cellular Communication System for Code Division Mutlipie Access (부호 분할 다원 접속을 위한 직접 확산 셀룰라 통신 시스팀의 동기)

  • 전정식;한영열
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.2
    • /
    • pp.207-217
    • /
    • 1993
  • In this paper, knowing a priori probability of phase offset between transmitted codes and reference codes in the receiver, we construct the state diagram of acquisition process of the direct sequence spread-spectrum communication system using the expanding window search. The scannings are performed from the cell with higher probability code epoch synchronization to that with lower one. We expand window size from initial value by r times of its previous size in each search, construct the corresponding the state diagrams, and derive average synchronization time using the Markov process and Mason's gain formula. Average synchronization times versus number of search n and detection probability $P_d$ are calculated.

  • PDF

STUDIES ON CYTOTOXICITY AND ANTITUMOR ACTIVITY OF KOREAN PHARMACEUTICAL HERBS

  • Ryeom, Kon;Lee, Young-Kee;Shin, Suck-Woo;Jung, Byung-Ki
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1995.04a
    • /
    • pp.62-62
    • /
    • 1995
  • 한국산 천연자원중 한방이나 민간요법에서 항종양제로 빈번히 사용되어온 생약들 중에서 103종을 선정하여 이들 성분들을 추출하고 시험관내에서 항종양성이 우수하고 정상세포에 손상을 적게 주는 생약 6종을 선별하여 암세포주에 대한 독성능 (in vitro)과 항종양성 면역감시기구(in vivo)및 LD$_{50}$등을 측정하여 항종양제로의 신약개발을 목적으로 수행하였다. 방법: 선별된 6종의 생약유효성분을 METHANOL로 추출하여 조추출물을 얻었으며 이물질들을 순차적으로 각각의 유기용매로 추출, column chromatography법으로 분획하였으며 분획분에 대한 암세포독성능은 MTT colorimetric 검정법을 이용하여 IC$_{50}$값을 구하였다. 면역감시기구 측정방범으로는 Balb/c mouae암,수 각 10수씩에 P388암세포주를 접종한군과 접종하지 않은 실험군에 생약추출분획물 8.6mg/0.2ml씩 20일간 매일 경구 투여시키고 대조군에는 생리식염수 0.2ml씩을 매일 경구 투여시켜 NK cell의 활성 MIF Recombinant IL-2로 유도시킨 NK cell활성능, chemotaxis등을 측정하였다. 생체내 항종양능 시험은 tumor panel system에 따라 mouse leukemia cell을 사용하여 측정하였다. 각분획성분의 투여용량은 실험동물에서 독성실험결과로 LD$_{50}$량을 구해 항암효과 평가시에 Maximum dose로 하였고 최고용량을 기준으로 일정한 공비를 적응하여 3단계의 투여량을 설정하였다. (중략)

  • PDF

Quality property of bioethanol blends & counterplan of infrastructure (바이오에탄올 혼합가솔린 품질특성 및 유통인프라 대응)

  • Jung, Choong-Sub
    • New & Renewable Energy
    • /
    • v.2 no.4 s.8
    • /
    • pp.102-106
    • /
    • 2006
  • 에탄올은 금속, 고무 수지를 부식시키고 열화시키기 때문에 FFV 등 알코올 대응차량이 아닌 경우 에탄올 허용도가 제한되고 있으며, 물과의 상호용해성과 흡습성으로 수분혼입에 의한 상분리가 발생하여 혼합가솔린의 유통에서의 취급에 어려움이 야기되고 있다. 또한, 에탄올은 가솔린과 혼합되면 공비현상으로 인하여 50% 유출온도가 크게 떨어지고 증기압이 7kPa 정도 상승을 초래하는 점도 간과하지 않을 수 없다. 따라서, 자동차용휘발유에 에탄올을 혼입하여 사용할 경우, 가솔린기재를 적절히 선택하여 적정품질을 유지하여야 하며 무엇보다도 에탄을 혼입농도에 따른 저장탱크와 주유기 등의 부품에의 영향과 저장시의 상분리 문제를 충분히 규명하여 유통인프라에서의 적절한 대응책이 마련되어져야 한다. 유통 인프라 대응을 위해서는 우선 생산단계에서 수분 혼입을 최소화하기 위하여 저유소의 출하지점에서 서브옥탄가솔린과 에탄올을 라인브랜딩에 의해 제조하는 방법이 가장 타당하며, 수송부문에서는 탱크로리 등의 공급라인인 파이프와 실링 재질 등에 대해서 면밀한 검토가 필요하다고 할 수 있다. 주유소에서의 대응은 에탄을 혼합연료와 직접 접촉하는 연료계 등 부품재질을 내부식성의 재질로 변환시켜야 하며, 수분혼입을 최소화하기 위한 이중탱크 설치, 지하탱크 환기구내의 대기벨브 설치 등이 필요하며, 기타, 품질 및 수분관리 대책 등도 마련되어야 할 것이다.

  • PDF

Acute Toxicity of Bovine Somatotrophine-Sustained Release(BST-SR) in Rats and Mice (랫드와 마우스에서 소성장 호르몬-서방형 제형(BST-SR)의 급성독성에 관한 연구)

  • 강경선;이영순
    • Journal of Food Hygiene and Safety
    • /
    • v.6 no.3
    • /
    • pp.185-189
    • /
    • 1991
  • This study was carried out to investigate whether acute toxicity of BST-SR is or not. Single dose of BST-SR was given to both sexes of Spraqe-Dawley rats and ICR mice, subcutaneously. No significant toxic symptom was observed in single treated rats and mice during the experimental period. In gross and microscopic observation, no significantly different abnormality observed between the several organs of tested animals and control animals. Therefore, it was concluded that BST-SR was nontoxic when BST-SR was subcutaneously administered to rats and mice up to 1000 times of clinical dose.

  • PDF

Silica aerogels for potential sensor material prepared by azeotropic mixture (공비혼합물로 제조된 다공성 센서재료용 실리카 에어로젤)

  • Shlyakhtina, A.V.;Oh, Young-Jei
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.395-400
    • /
    • 2007
  • Ambient drying sol-gel processing was used for monolithic silica ambigels in the temperature range of $130-250^{\circ}C$. A new method of mesopore ambigels, which mean the aerogels prepared by ambient pressure drying process synthesis, is suggested at first. This method includes two important approaches. The first point is that $SiO_{2}$ surface modification of wet gel was performed by trimethylchlorosilane in n-butanol solution. This procedure is provided the silica gel mesopore structure formation. The second point is a creation of the ternary azeotropic mixture water/n-butanol/octane as porous liquid, which is effectively provided removing of water such a low temperature by 2 step drying condition under ambient pressure. The silica aerogels, which were prepared by ambient pressure drying from azeotropic mixture of water/n-butanol/octane, are transparent, crack-free and mesoporous (pore size ${\sim}$ 5.6 nm) with surface area of ${\sim}$ $923{\;}m^2/g$, bulk density of $0.4{\;}g/cm^3$ and porosity of 85 %.

An experimental investigation of thermodynamic performance of R-22 alternative blends (R-22 대체용 혼합냉매의 열역학적 성능에 대한 실험연구)

  • Hwang, E.P.;Kim, C.N.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.82-91
    • /
    • 1997
  • R-410a and R-407c witch have the best potential among the substances being considered as R-22 alternatives were tested as "drop in" refrigerants against a set R-22 baseline tests for comparison. The performance evaluations were carried out in a psychrometric calorimeter test facility using the residential split-type air conditioner under the ARI rating conditions. Other than the use of different lubricant and a hand-operated expansion valve, one of the commercial systems was selected for the experiment. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly applied to the existing refrigeration system because of its similar vapor pressure and other thermopysical properties with those of R-22. However, it required change to the volume flow rate of compressor in order to achieve the similar performance with R-22 because of its relatively small VCR and capacity. Meanwhile, R-410a has too high a vapor pressure to be applied to the existing system and this feature results in relatively low COP of the system compared to that of R-22. But this could be improved by changing compressor design considering R-410a's relatively high VCR and capacity compared to those of R-22.

  • PDF

Condensation Heat Transfer Coefficients of Binary Refrigerant Mixtures on Enhanced Tubes (열전달 촉진관에서 2원 혼합냉매의 외부 응축열전달계수)

  • 김경기;서강태;채순남;정동수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.161-167
    • /
    • 2002
  • In this study, external condensation heat transfer coefficients (HTCs) of two non-azeotropic refrigerant mixtures of HFC32/HFC134a and HF0134a/HCF0123 at various compositions were measured on both low fin and Turbo-C enhanced tubes of 19.0 mm outside diameter All data were taken at the vapor temperature of 39$^{\circ}C$ with a wall subcooling of 3- 8 K. Test results showed that HTCs of the tested mixtures on the enhanced tubes were much lower than the ideal values calculated by the mass fraction weighting of the pure compo- nents'HTCs. Also the reduction of HTCs due to the diffusion vapor film was much larger than that of a plain tube. Unlike HTCs of pure fluids, HTCs of the mixtures measured on enhanced tubes increased as the wall subcooling increased, which was due to the sudden break up of the vapor diffusion film with an increase in wall subcooling. Finally, heat transfer enhancement ratios for mixtures were found to be much lower than those of pure fluids.

A Study on the Refrigerant Characteristics of the HFC-l52a, and Azeotrope Mixed with $CF_3 I$ (HFC-152a와 HFC-1523에 $CF_3 I$를 혼합한 공비혼합냉매 특성에 관한 연구)

  • 이종인;하옥남;김재열;이연신;권일욱
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.6
    • /
    • pp.102-108
    • /
    • 2001
  • To prevent green house effect and destruction of an ozone layer, an ozone destruction potential(OBP) must be zero and a refrigerant for low global warming potential(GWP) is needed. HFC-l34a, in which hydrogen is mixed instead of chlorine is a refrigerant used for automobile conditioners and its destruction potential is ecologically zero. However, it is not consid- ered as a perfect substitutive refrigerant as its GWP is high. It is studied refrigerant mixtures in which HFC-l52a and $CF_3 I$ in HFC-l52a with low GWP and zero ODP are mixed by experimentally and concluded as follows: 1) With the variation of speed of compressor outside temperature and flow rate, 7he heat of evaporator and compressor and coefficient of perfor- mance was varied, and influenced the air conditioner. 2) The pressure of evaporator was decreased with increasing the speed of compressor and the pressure of evaporator with the refrigerant HFC-l52a was higher 24% than that of azotrope refrigerant mixed with $CF_3 I$

  • PDF

Pool Boiling Heat Transfer Correlation for Mixture Refrigerants (혼합냉매의 풀비등 열전달 상관식)

  • 고영환;김종곤;박진석;정동수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.122-133
    • /
    • 2001
  • Pool boiling heat transfer coefficients(HTCs) of HFC32/HFC134a, HFC125/HFC134a, HFC32/HFC125 and HFC32/HFC125/HFC134a were measured on a horizontal smooth tube. The experimental apparatus was specially designed to simulate the real heat transfer tube with the use of the secondary fluid of water. Data were taken in the order of decreasing heat flux starting at 80kW/$m^2\; and\; ending\; at\; 5kW/m^2$ in the pool temperature at $7^{\circ}C$. Test results showed that HTCs of these mixtures were 11~38% lower than those of ideal HTCs calculated by a linear mixing rule with pure fluids、 HTCs. Experimental data were compared with Stephan & Korner, Thome, Schlunder, Thome & Shakir、s correlations only to find that those correlations were not satisfactory for all fluids. Hence, a new correlation based on the present data was proposed which could be applied even to the ternary mixture. The correlation predicts the degradation of HTCs of mixtures well, showing a mean deviation of less than 15% for all the mixture data.

  • PDF

Thermodynamic Performance Analysis of Ammonia-Water Power Generation System Using Low-temperature Heat Source and Liquefied Natural Gas Cold Energy (저온 열원과 LNG 냉열을 이용하는 암모니아-물 동력 사이클의 열역학적 성능 해석)

  • Kim, Kyoung Hoon;Kim, Kyung Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.483-491
    • /
    • 2014
  • In this study, a thermodynamic analysis was carried out for a combined power generation system using a low-temperature heat source in the form of sensitive energy and liquefied natural gas cold energy. An ammonia-water mixture, which is a zeotropic mixture, was used as the working fluid, and systems with and without a regenerator were comparatively analyzed. The effects of the mass fraction of ammonia and the condensation temperature of the working fluid on the system variables, including the net work production, exergy destruction, and thermal and exergy efficiencies, are analyzed and discussed. The results show that the performance characteristics of the system varied sensitively with the ammonia concentration or condensation temperature of the working fluid. The system without regeneration was found to be better in relation to the net work per unit mass of the source fluid, whereas the system with regeneration was better in relation to the thermal or exergy efficiency.