• Title/Summary/Keyword: 공명 소음

Search Result 148, Processing Time 0.031 seconds

Study on Analysis of Acoustic Noise in MRI (자기 공명 영상법에서의 소음 분석에 관한 연구)

  • Park, S.H.;Chung, S.T.;Chung, S.C.;Cho, Z.H.;Moon, C.W.;Yi, J.H.;Sin, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.550-554
    • /
    • 1997
  • Acoustic or sound noise due to gradient pulsing has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as unctional MRI (fMRI). Our recent observations in MRI or the visual and motor cortex show very different results with sound noise in comparison with the results obtained without sound noise. Although a number of ideas has been suggested in the literature about the possible elimination or reduction of sound noise, progress has been slow due to the basic role of gradient pulsing in MR imaging. Therefore, we report on some typical behavior of sound noise observed from MRI scanners and the analyses of their characteristics. Data are obtained both from a commercial MRI scanner (GE Signa 1.5-T EPI system).

  • PDF

Female External Genitalia and Urethra on MR Imaging: Optimal Pulse Sequence and Comparison of Anatomy in Premenopausal and Postmenopausal Women (여성 외부 생식기와 요도의 자기공명영상 소견: 적합한 영상기법과 폐경 전후의 해부학적 변화 비교)

  • Whang, Shin-Young;Ahn, Kyung-Sik;Sung, Deuk-Jae;Park, Beom-Jin;Kim, Min-Ju;Cho, Sung-Bum;Lee, Nam-Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.146-153
    • /
    • 2011
  • Purpose : To describe normal anatomy and compare the differences of external genital organs and urethra on MR imaging in pre- and postmenopausal women. Materials and Methods : A total of 19 pre- and 18 postmenopausal healthy women underwent pelvis MR imaging at 1.5 T. Two radiologists retrospectively scored and compared the image quality of female external genitalia and urethra on axial T2-weighted images (T2WI) and axial fat-suppressed contrast-enhanced T1-weighted images (FSCE-T1WI) by using Wilcoxon signed ranks test. The radiologists compared the wall thickness or size of external genital organs and urethra on FSCE-T1WI between two groups by using Student t test. Results : Image quality was better with FSCE-T1WI than with T2WI in all subjects (p < 0.05). The vestibular bulb, clitoris and labium minor were more clearly visualized on FSCE-T1WI in premenopausal subjects rather than in postmenopausal subjects (p < 0.05). The urethra had a target-like appearance with three layers in premenopausal and postmenopausal subjects. Postmenopausal subjects were observed to have significantly smaller vaginal wall thickness, urethral wall thickness and vestibular bulb width than premenopausal subjects (p < 0.05). Conclusion : The anatomy and morphologic changes of female external genital organs and urethra were well discernible on FSCE-T1WI.

A study on in-flight acoustic load reduction in launch vehicle fairing by FE-SEA hybrid method (FE-SEA 하이브리드 기법을 이용한 비행 중 발사체 페어링 내부 음향하중 저감에 관한 연구)

  • Choi, Injeong;Park, Seoryong;Lee, Soogab
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.4
    • /
    • pp.351-363
    • /
    • 2020
  • Launch vehicles are subject to airborne acoustic loads during atmospheric flight and these effects become pronounced especially in transonic region. As the vibration due to the acoustic loads can cause malfunction of payloads, it is essential to predict and reduce the acoustic loads. In this study, a complete process has been developed for predicting airborne vibro-acoustic environment inside the payload pairing and subsequent noise reduction procedure employing acoustic blankets and Helmholtz resonators. Acoustic loads were predicted by Reynolds-Averaged Navier-Stokes (RANS) analysis and a semi-empirical model for pressure fluctuation inside turbulent boundary layer. Coupled vibro-acoustic analysis was performed using VA One SEA's Finite Element Statistical Energy Analysis (FE-SEA) hybrid module and ANSYS APDL. The process has been applied to a hammerhead launch vehicle to evaluate the effect of acoustic load reduction and accordingly to verify the effectiveness of the process. The presently developed process enables to obtain quick analysis result with reasonable accuracy and thus is expected to be useful in the initial design phase of a launch vehicle.

Comparison with 1.5Tesla and 3.0Tesla of Acoustic Noise Spectrum of DWI MR Pulse Sequence (1.5Tesla and 3.0Tesla에서 관류 MR의 소리 스펙트럼 분석)

  • Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.491-496
    • /
    • 2018
  • The purpose of this study is to analyze the noise spectra in DWI (diffusion-weighted imaging) pulse sequences of 1.5 Tesla and 3.0 Tesla MRI, The ACR (American College of Radiology) phantom and noise spectrum were analyzed by FFT (fast Fourier transform) and TFFT (temporal frequency analysis) using WavePad sound editor version 8.13 (NCH software, Greenwood Village, CO, USA). Noise spectra, FFT and TFFT were analyzed for laboratory 1.5Tesla and 3.0Tesla DWI MR pulse sequences. The noise threshold of the frequency amplitude in the FFT and TFFT at 3.0Tesla compared to 1.5Tesla was between 1.5Tesla and -6 dB, and between 3.0Tesla and 0 dB, the DWI pulse sequence for the patient's noise reduction was appropriately MR examination needs to be applied.

Comparison of Claustrophobia, Noise Sensitivity and Vital Signs according to Anxiety Sensitivity Level before and after MRI (자기공명영상(MRI) 검사 전·후 불안민감성 제수준에 따른 폐쇄공포, 소음민감성 및 활력징후 비교)

  • Park, Young-Hae
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.6
    • /
    • pp.950-959
    • /
    • 2008
  • Purpose: The present study was conducted in order to examine claustrophobia, noise sensitivity and vital signs according to anxiety sensitivity level in patients who have Magnet Resonance Imaging(MRI). Methods: With 100 outpatients, we measured anxiety sensitivity, claustrophobia, noise sensitivity and vital sign before and after MRI. Measuring tools were ASI, CLQ-M, and NSI. Data were collected from February to March, 2008. Results: The ASI score was higher in women than in men(p < .05), and no statistically significant difference was observed according to age, region of scanning, experience in MRI, and the use of contrast agent. Both men and women patients showed the same ASI score and decrease in CLQ M and NSI between before and after MRI. In women, ASI, CLQ M and NSI were in positive correlation with one another(p < .001), and in men, there was no correlation between ASI and CLQ M, and positive correlation was observed with NSI(p < .05). In comparison according to ASI level, blood pressure and pulse rate were not different in men and women. CLQ M was not different in men, but was different in women(p < .001). NSI was different in both men and women(men p < .05; women p < .001). Conclusion: MRI may cause claustrophobia in patients with high anxiety sensitivity, and noise appears to aggravate anxiety. In particular, claustrophobia was more serious in women than in men. Therefore, it is necessary to develop nursing interventions to reduce anxiety sensitivity particularly for female patients, and to make plans to educate and lower noise before MRI in order to reduce claustrophobia.

  • PDF

A Study on Noise Reduction of Rotary Compressor (공조용 로터리 압축기의 소음 저감에 관한 연구)

  • Ahn, B.H.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.60-69
    • /
    • 1999
  • The noise and vibration sources of rotary compressor for room air-conditioner are pressure pulsation of compression process, cavity resonance of inner space, structural radiation noise of shell and impact noise of discharge valve. Among them, pressure pulsation is very important noise and vibration source. Because it transferred various kinds of noise and vibration like as mentioned above. In this reason, muffler and resonator are used in order to absorb and remove these noises. But an analytical prediction using acoustic analysis does not coincident with the experimental result. The difference between analysis and actual state is due to the assumption of analysis. This paper covered with new concept of muffler design based on the turbulence kinetic energy of flow by using CFD. From this analysis, it is possible to decide the best position of discharge port of muffler. Therefore $2{\sim}3dB$ noise reduction effect is acquired in rotary compressor of 5000 BTU grade. Also new approach of resonator design is suggested. From this study, the characteristics of resonator and surge hole (a kind of resonator without pipe length) are identified. The former is useful for pure tone noise (narrow frequency band), and the latter is effective for broad frequency band. This paper shows that it is very available to use 3 dimensional analysis of resonator in order to predict more exact tuning frequency. The result is proved by a lot of experiments. From combination of fluid analysis and acoustic analysis, up stream position is effective location of resonator concerning turbulence motion of fluid.

  • PDF

An Study on the Correlation between Sound Characteristics and Sasang Constitution by CSL (CSL을 통한 음향특성과 사상체질간의 상관성 연구)

  • Shin, Mi-ran;Kim, Dal-lae
    • Journal of Sasang Constitutional Medicine
    • /
    • v.11 no.1
    • /
    • pp.137-157
    • /
    • 1999
  • The purpose of this study is to help classifying Sasang Constitution through correlation with sound characteristic. This study was done it under the suppose that Sasang Constitution has correlation with sound spectrogram. The following result were obtained about correlation between sound spectrogram and Sasang Constitution by comparison and analysis 1. Soeumin answered his voice low tone, smooth and quiet in the survey. Soyangin answered his voice high, clear, fast and speaking random. Taeumin answered his voice low, thick and muddy. 2. Taeyangin was significantly slow compared with the others in the time of reading composition. Taeyangin was significantly slow compared with the others in Formant frequency 1. Taeyangin was significantly discriminated from Soeumin in Formant frequency 5. Taeyangin was significantly low compared with the others in Bandwidth 2. Soeumln was significantly low compared with Taeyangin in Pitch Maximum and Pitch Maximum-Pitch Minimum. Taeyangin was significantly high compared with the others in Energy mean. 3. In list of specification, the discrimination rate was higher than that by lists of 13 in the results of Multi-dimensional 4-class minimum-distance. The discrimination rate of three disposition except Soyangin was higher than that of four disposition in the results of One way ANOVA and Analysis of dis crimination in SPSS/PC+. In CART, the estimate rate of Sasang Constitution discrimination was higher than any other method. It is considered that there is a correlation between sound spectrogram and Sasang constitution according to the results. And method of Sasang constitution classification through sound spectrogram analysis can be one method as assistant for the objectification of Sasang constitution classification.

  • PDF

A study on Evaluating Validity of SNR Calculation Using a Conventional Two Region Method in MR Images Applied a Multichannel Coil and Parallel Imaging Technique (다중채널코일과 병렬영상기법 이용 시 두영역측정법을 사용한 신호대잡음비 측정의 문제점)

  • Choi, Kwan-Woo;Son, Soon-Yong;Min, Jung-Whan;Kwon, Kyung-Tae;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.403-410
    • /
    • 2015
  • The purpose of this study was to investigate the problems of a signal to noise ratio measurement using a two region measurement method that is conventionally used when using a multi-channel coil and a parallel imaging technique. As a research method, after calculating the standard SNR using a single channel head coil of which coil satisfies three preconditions when using a two region measurement method, we made comparisons and evaluations after calculating an SNR by using a two region measurement method of which method is problematic because it is used without considering the methods recommended by reputable organizations and the preconditions at the time of using a multi-channel coil and a parallel imaging technique. We found that a two region measurement method using a multi-channel coil and a parallel imaging technique shows the highest relative standard deviation, and thus shows a low degree of precision. In addition, we found out that the difference of SNR according to ROI location was very high, and thus a spatial noise distribution was not uniform. Also, 95% confidence interval through Blend-Altman plot is the widest, and thus the conformity degree with a two region measurement method using the standard single channel head coil is low. By directly comparing an AAPM method, which serves as a standard of a performance evaluation test of a magnetic resonance imaging device under the same image acquisition conditions, an NEMA method which can accurately determine the noise level in a signal region and the methods recommended by manufacturers of a magnetic resonance imaging device, there is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a two region measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.