• Title/Summary/Keyword: 공명현상

Search Result 249, Processing Time 0.025 seconds

An Experimental Study on Noise Phenomena in Supersonic Over-expanded Jet (초음속 과팽창 제트에서 발생하는 소음현상에 관한 실험적 연구)

  • Kweon Yong-Hun;Lim Chae-Min;Kim Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.337-340
    • /
    • 2006
  • The present paper describes an experimental work to investigate a transonic resonance in supersonic jet that is discharged from a convergent-divergent nozzle. When the nozzle m: at low nozzle pressure ratios, the shock occurs within the divergent section of the nozzle. The transonic resonance of a jet flow is generated by an emission of strong acoustic tones due to the unsteadiness of the shock. A Schlieren optical system is used to visualize the supersonic jet flow In order to specify the flow resonance of a jet, acoustic measurements are performed to obtain noise spectra. The acoustic characteristics of transonic resonace are compared with those of screech tones. The results obtained show that unlike screech frequency, the transonic reso- nace frequency somewhat increases with increasing the nozzle pressure ratio.

  • PDF

Detection of Micro-Crack Using a Nonlinear Ultrasonic Resonance Parameters (비선형 초음파공명 특성을 이용한 미세균열 탐지)

  • Cheong, Yong-Moo;Lee, Deok-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.369-375
    • /
    • 2012
  • In order to overcome the detection limit by the current nondestructive evaluation technology, a nonlinear resonant ultrasound spectroscopy(NRUS) technique was applied for detection of micro-scale cracks in a material. A down-shift of the resonance frequency and a variation of normalized amplitude of the resonance pattern were suggested as the nonlinear parameter for detection of micro-scale cracks in a materials. A natural-like crack were produced in a standard compact tension(CT) specimen by a low cycle fatigue test and the resonance patterns were acquired in each fatigue step. As the exciting voltage increases, a down-shift of resonance frequency were increases as well as the normalized amplitude decrease. This nonlinear effects were significant and even greater in the cracked specimen, but not observed in a intact specimen.

A Resonance Characteristic of bronze washbasin (백천사 청동 대야의 울림 특성에 관한 연구)

  • Yi, Eun-Young;Ahn, Ik-Soo;Bae, Myung-Jin
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2017.01a
    • /
    • pp.201-202
    • /
    • 2017
  • 공명은 외부에서 진동계를 진동시킬 수 있는 힘을 가했을 때 그 고유진동수와 외부에서 가해주는 힘의 진동수가 같으면 그 진동은 심해지고 진폭도 커진다. 진동체가 서로 연결되어 있는 경우, 양쪽 진동수가 같으면 공명에 의해 에너지를 서로 교환하는 현상이다. 본 논문에서는 경남 사천에 소재하는 백천사의 사찰 마당에 있는 청동 대야를 사람이 손잡이를 문지를 때 발생하는 파동 현상을 고찰한 연구이다. 청동 대야에서 발생하는 진동수는 3가지 성분이다. 이 음은 복합음의 일종으로 볼 수 있다. 복합음의 기본 특성은 기본음이 배음보다 음압이 크다. 철제에서 생성되는 음압의 형태와 단조로운 순음인 경우가 많다. 청동 대야의 음압은 맥놀이 특성을 나타내고 있어 진폭변조의 포락선을 형성하고 있다.

  • PDF

Observation with Calcifications of Breast Tissue Phantoms Using Acoustic Resonance (공명현상을 이용한 유방조직 팬텀의 석회화 관찰)

  • Ha, Myeung-Jin;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.61-69
    • /
    • 2008
  • Diagnosis of breast ultrasound is better than mammography in the early detection of breast cancer, but, it is difficult to detect microcalcification. We studied on detection for calcification of breast tissue using acoustic resonance and power doppler with 7.5 MHz linear probe in breast ultrasound. We first constructed breast tissue phantom made of gelatin and saw breast, and then observed calcification by the change of external vibration. Calcification injected breast tissue phantom visualized the difference for brightness and region of color in ROI regions of power doppler. Acoustic resonance almost never visualized in low frequency regions, plateau constituted in about 300-400 Hz and colors vanished according to the increase of frequency.

  • PDF

HID 램프용 전자식 안정기 회로 및 특성 이해

  • 김기정
    • Electric Engineers Magazine
    • /
    • v.230 no.10
    • /
    • pp.30-33
    • /
    • 2001
  • 음향공명 발생원인 가스가 들어있는 방전관내에 방전전류가 흐르면 전력에너지가 발생하여 열을 발생 시키고 이 열은 방전관내의 압력변화를 가져온다. 이 압력변화는 방전관내의 음향변화와 같다. 주기적인 압력변화가 내벽에 반사되어 정재파가 발생되는 현상이 방정관의 고유진동수이며 이 고유진동수와 전원주파수가 일치될 때 음향공명현상이 일어난다.

  • PDF

Reduction of Acoustic Resonance Phenomena in Pulse Start MetalHalide Lamp (MH200W) (고효율 펄스스타트 메탈핼라이드램프(MH200W)의 음향공명현상감소)

  • 김기정
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.8-14
    • /
    • 2001
  • MetalHalid lamps have good efficiency, good color rendition and good focusing capability. But the shortcoming of metalhalid lamps is blown as acoustic resonance phenomena in the arc tube. Such acoustic resonance produce annoying fluctuations in the intensity and distribution of the emitted light, they can raise the voltage to the point where the arc is extinguished and they can move the arc close enough to the wall to cause local overheating and tube cracking. The objective of this research is to reduce acoustic resonance in the arc tube of the Pulse Start MetaIHaide lamp(MH200[W]). To reduce the acoustic resonance phenomena the electronic ballast was designed for high frequency operation with the constant frequency sinusoidal wave of 89[kHz] in the 84.6[kHz]∼94.2[kHz] range. Experimental results show that the acoustic resonance phenomena are not in the arc tube of Pulse Start MetalHalide lamp (MH200[W]) .

  • PDF

Development of 3D Projection Reconstruction MR Angiography

  • 김대흥;김은주;정은기
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.148-148
    • /
    • 2001
  • 목적: 자기 공명 혈관 영상(MR Angiography)법으로 혈관 촬영시, 혈관 협착으로 인하여 난류 현상이 발생되는 곳에서는 영상 자체가 얻어지지 않는다. 기존에 TE를 줄이거나 또는 projection reconstruction 방법은 2차원 TOF(Time of Flight)에 적용이 되어서 좋은 결과를 얻었다. 그런데, 2차원 TOF보다는 3차원 TOF으로 보다 좋은 혈관 영상을 얻을 수가 있다. 하지만, 3차원 TOF 방법에 projection reconstruction 방법을 적용하는 데는 여러 가지 문제점이 있어서 개발되어 있는 것이 거의 없다. 본 연구에서는 3차원 TOF 방법에 projection reconstruction 방법을 적용하여서 혈관내의 난류 현상에 의한 영상의 왜곡을 극복하는 방법을 개발한다. 대상 및 방법: 3차원 projection reconstruction을 위한 pulse sequence를 실제 진단에 사용하는 GE사의 자기공명영상장치(1.5T)에 맞게 독자적으로 개발한다. GE사의 장비에서 자료를 얻어서 일반 컴퓨터에서 영상을 재구성하는 알고리즘을 자체 개발한다. 혈관에서와 비슷한 형태의 난류를 발생시킬 수 있는 기구를 만들어서 실제 혈관영상에 사용하는 방법과 개발한 방법으로 영상을 비교한다.

  • PDF

Performance Evaluation of Seawater-Exchanging Breakwater Using Helmholtz Resonator (헤름홀츠 공명장치를 이용한 해수교환형 방파제의 성능평가)

  • 조일형
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.13 no.2
    • /
    • pp.89-99
    • /
    • 2001
  • In the present paper, Helmholtz resonator, which is widely used as a sound-amplification device, is applied to the development of seawater-exchanging breakwater. The incident waves can induce a large response in the resonator when incident wave frequency is close to one of natural modes of the resonator. Largely amplified potential energy due to the resonance supplies clean seawater into the harbor side throughout the channel. Flow supplied by the resonator circulates the seawater of harbor and helps to improve water quality. Within the framework of linear potential theory, matched asymptotic expansion method is employed to analyze the wave responses in a resonator. The semi-circular shape of the resonator has been chosen as an analytic model for mathematical simplicity. The wave responses of both single and arrays of Helmholtz resonator are investi¬gated. To validate an analytic solution, model test is conducted at 2-dimensional wave tanle Wave hcights in the resonator and velocity at the channel are measured for the state of valve-on and valve-off.

  • PDF