• Title/Summary/Keyword: 공명신호

Search Result 496, Processing Time 0.037 seconds

CARS에서 배경신호의 제거에 의한 분광선회복

  • 이은성
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.457-463
    • /
    • 1993
  • We investigated that the CARS signals generated from resonant or nonresonant contributions can be selectively suppressed by phase-controlled nonlinear interferometry. To control the phase of the CARS signal over a broad spectral range, a home-made phase shifting unit was used, whose thickness was automatically controlled as the wavelength of Stokes beam scaned. Using this technique, we recovered the Q-branch resonance lines of carbon monoxide and HC1 which had been distorted and buried by the nonresonant and resonant signal of propane respectively. All the spectrum measured have been normalized by reference signal which had no resonance lines over the spectral range of interest.

  • PDF

Low Fiele Measurement of 0.1 mT by Rabi's NMR Method (Rabi법 핵자기 공명에 의한 0.1 mT의 저자장 측정)

  • 유권상;김철기;우병칠;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.2
    • /
    • pp.139-142
    • /
    • 1993
  • The Rabi's NMR experiment using polarized flowing water was performed in order to measure the low field and the good NMR signal was obtained in the range of 0.1 mT. There was a change in amplitude and phase of signal due to the sinusoidal variation with the increasing RF field. The nominal field could be determined within a few tens ppm uncertainty by the NMR signal under the optimized RF condition.

  • PDF

자기공명영상에서 신호의 dynamic range와 quantization noise 분석

  • 안창범;이정선;김휴정;이흥규
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.75-75
    • /
    • 2002
  • 목적: 고자장 자기공명영상 시스템 등으로 신호대잡음비가 향상됨에 따라 데이터 측정에서 analog-to-digital converter (ADC)의 quantization noise 가 중요한 시스템 사양으로 부각되고 있다. 특히 자기공명영상은 공간주파수 영역에서 데이터를 측정하기 때문에 dc와 ac간의 신호 차이가 매우 크며, 이러한 dynmic range는 3-D 영상에서 더욱 커진다. 본 연구에서는 다양한 자기총명 영상기법 및 실험 파라미터에 따른 신호의 dynamic range와 ADC의 bit 수에 따른 quantization noise를 살펴봄으로써, 주어진 시스템에 적합한 ADC의 bit 수를 분석하고자 한다. 대상 및 방법: 펄스 시퀀스의 종류, 파라미터, 2D/3D 등에 따른 각 신호의 크기를 수학적으로 모델링하여 신호의 크기를 예측하였다. 또한 whole body MRI 시스템에서 실험을 통하여 신호의 크기를 비교하였다. ADC의 quantization noise를 실험과 시뮬레이션을 통하여 살펴보았다. 시뮬레이션은 test 영상을 Inverse FFT 하여 spatial frequency domain data를 만든 후, 다양한 bit 수의 ADC로 quantization을 한 후 다시 영상을 재구성하였다. 재구성된 영상과 원영상 간의 error가 quantization noise가 된다. 또한 이러한 error가 주파수 영역에서의 error 값과 일치하는지를 확인하였다.

  • PDF

Study on NMR Measurment of Flowing Water by a Separated Detector (분리형 감지기를 이용한 흐르는 물의 핵자기공명 측정연구)

  • ;;;;V. Ya. Shifrin
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.3
    • /
    • pp.165-170
    • /
    • 1995
  • NMR measurement has been studied for protons in pre-polarized flowing water by a separated detector working at high field far away from the measured field region where the transition of protons is occurred by the pertur-bation of RF energy. The conditions for NMR signal were optimized on the amplitude and frequency of modulation field, the RF field of detector, water speed, and RF field at the measured field region. The NMR signal with the full width of 320 nT at the half maximum in Lorentzian curve and with signal to noise ratio of 10.5 was measured in the range from a few ${\mu}T$ to mT, and its shape and amplitude were independent of the measured field intensity and its uniformity.

  • PDF

A State-of-the Art MRI of the Lungs Using Hyperpolarized Gas

  • 이동훈
    • Proceedings of the KSMRM Conference
    • /
    • 1999.11a
    • /
    • pp.19-25
    • /
    • 1999
  • 허파에 대한 수소 자기공명영상은 현재까지 거의 불가능한 것으로 알려져 있다. 허파의 조직과 비어있는 공간 사이의 심한 자화율(susceptibility) 차이로 인해서 영상왜곡 현상이 유발되어 그릇된 영상정보를 만들기 때문이다. 본 강좌에서는 이러한 문제를 해결할 수 있는 레이저 광펌핑 방법으로 초편극화된 비활성기체를 이용한 자기공명연구를 소개한다. 일반적인 자기공명 신호와 쳐편극화된 비활성기체를 이용한 자기공명 연구를 소개한다. 일반적인 자기공명 신호와 초편극화 기체를 이용한 신호의 차이와 물리적인 원리를 고찰할 것이다 . 비활성기체가 초편극화 되었을 때, 일반적인 자기공명의 경우에 (자기장: 1 Tesla, 온도는 $30^{\circ}C$의 열평형상태) 비해서 약 $10^{5}$ 정도의 magnetizaion 향상을 기대할 수 있으며, 기체상태라는 점이 감안된다 해도 의미 있는 자기공명신호를 획득할 수 있다. 비활성기체를 초편exchange 방법을 통하여 간접적으로 가스를 편극화 시키는 두 가지 방법이 있다. 이들의 기본적인 원리와 두 방법의 장단점 등을 알아 볼 것이다. 더불어, 초편극화 정도가 외부자기장의 세기 차이에 의한 영향을 받지 않는 다는 특성을 이용하는 경우, 비용을 최소화 하면서 고해상도의 영상을 얻을 수 있으며, 이동성이 용이한 낮은 자기고명진단기가 가능한데 이에 대한 소개를 할 것이다. 그리고, 초편극화가스를 이용한 자기공명영상 연구의 현재 동향 및 미래에 대해서 논의한다.

  • PDF

악성뇌종양 주변부위의 역동자기공명영상의 시간신호강도곡선 양상과 예후와의 관계

  • 최순섭;김기욱;허기영;이영일
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.21-21
    • /
    • 2003
  • 목적: 악성뇌종양 주변부위의 역동자기공명영상에서의 시간신호강도곡선 양상으로 종양의 성장 양상이나 예후를 판단할 수 있는지를 알고자 한다. 대상 및 방법: Anaplastic oligodendroglioma 3예, Anaplastic astrocytoma 1예, Glioblastoma multiforme 1예, Malignant ependymoma 2예, Medulloblastorna 1예로서, 총 8예의 종양절제전, 혹은 후의 잔류 종양을 대상으로 하였다. Routine MRI에 추가하여 종양부위에서 Turbo spin echo T1 강조 역동자기공명영상을 하였으며, Gd-DTPA 0.1 mmol/kg를 급속 주사 한 후, TR/TE, 350/15, slice thickness 6 mm, slice number 3, NEX 2회, scan time은 15 초로 하여 5 분 동안 20회 영상을 얻었다. 가시적으로 조영증강이 없는 종양의 주변부위나 수술경계부위에 관심영역을 그려서 시간신호강도곡선을 얻었으며, 첫 회 조영제 통과시의 peak 이후에 신호가 감소하는 경우를 Normal pattern으로, peak 이후에 신호가 계속 유지되거나 증가하는 경우를 Tumor pattern으로 하였으며, Normal pattern과 Tumor pattern을 보인 예들을 구분하여 종양의 재성장 상태와 환자의 생존 기간을 비교 관찰하였다.

  • PDF

New Implementation Method of the Pulsed Nuclear Magnetic Resonance Apparatus (펄스방식의 핵자기 공명장치에 관한 새로운 구현방법)

  • 김청월
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.10
    • /
    • pp.1-11
    • /
    • 1998
  • This paper presents a new implementation method of the pulsed NMR(nuclear magnetic resonance) apparatus, which contains a single coil in a magnet console, to detect a NMR signal. Applying an RF magnetic field of 5MHz to the magnet console which is designed to have Larmor frequency of 5MHz for hydrogen atom, the hydrogen NMR signal was obtained from the glycerin which was put in the magnet console as a sample. The DC magnetic field in the magnet console was implemented with a permanent magnet of 1168 gauss and the RF magnetic field was generated appling an RF signal with the frequency of 5MHz and the current magnitude of 8A to a coil of 5.73${\mu}$H. The magnitude of the NMR signal was maximum when the RF magnetic field was generated for 2.8 ${\mu}$sec, and the period of generating the RF magnetic field was designed to 100msec for detecting the NMR signal repeatedly. The NMR signal, radiated from the sample in the magnetic console, was appeared as an amplitude-modulated signal with a frequency equal to the Larmor frequency. The signal, induced in the coil, was amplified in the tx/rx separation circuit, preamplifier and intermediate amplifier by a factor of 20.7dB, 36dB and 40dB, respectively, and the signal was detected by a synchronous detection circuits, then the NMR signal was obtained.

  • PDF

Investigation of Correlations of Double Inversion Recovery and MR Spectroscopy on Breast MR Imaging (유방 자기공명영상에의 이중반전회복기법과 자기공명분광영상법의 상관관계 연구)

  • Ryu, Jung Kyu;Rhee, Sun Jung;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.34-42
    • /
    • 2014
  • Purpose : To evaluate the correlation of lesion-to-normal ratio (LNR) of signal intensity from double inversion recovery MR imaging and total choline-containing compound (tCho) resonance from single voxel MR spectroscopy in breast cancers. Materials and Methods: Between August 2008 and December 2009, 28 patients who were diagnosed as breast cancer and had undergone both double inversion recovery (DIR) MR imaging and MR spectroscopy (MRS) were included in this study. The signal intensities of the lesion (L) and ipsilateral normal breast tissue (N) were measured in region of interest of each breast cancer in DIR and contrast enhance MR image (CE-T1WI) to calculate the LNR value for each technique. MRS was performed using single-voxel MR spectroscopy. The height, width and area of tCho resonance were compared with each LNR of DIR and CE-T1WI. We used Pearson's correlation coefficient(r) for correlation analysis and the significance level was p=0.05. Results: There was no statistically significant correlation between LNR of CE-T1WI and height (r=-0.322, p=0.094), width (r=-0.233, p=0.232) and area (r=-0.309, p=0.109) of MRS tCho. There was no statistically significant correlation between LNR of DIR and height (r=0.067, p=0.735), width (r=-0.287, p=0.139) and area (r=0.012, p=0.953) of MRS tCho, either. The Pearson's correlation coefficient was 0.186 between LNRs of CET1WI and DIR (p=0.344). Conclusion: There was no statistically significant correlation between LNR of DIR and relative amount of tCho resonance of MRS.

3T 자기공명영상장치 내에서 측정한 뇌파로부터의 심장박동 제거를 위한 신호처리 방법

  • 김경환;윤효운;박현욱
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.76-76
    • /
    • 2003
  • 목적: fMRI와 뇌파의 동시측정 방법은 높은 시간적-공간적 해상도를 동시에 달성할 수 있는 뇌기능 측정을 가능케 하고, 각각의 방법이 제공하는 정보를 상호보완적으로 동시에 이용할 수 있도록 하는 유용한 방법이다. 그러나 자기공명영상을 얻기 위한 경사자계가 유발하는 잡음과 높은 자기장 내에서의 심장박동으로 인한 미세한 움직임 때문에 생기는 잡음이 뇌파신호의 질을 크게 저하하는 요소로 작용하여 이를 해결하기 위한 계측시스템의 최적화와 신호처리 방법의 개발이 요구된다. 본 논문에서는 평균차감법과 recursive least square 적응 필터링 방법에 기반한 심장 박동잡음의 감소를 위한 신호처리 방법의 개발 결과에 대한 연구 결과를 제시한다.

  • PDF

The Characteristics of Resonant Stimulated Raman Scattering in the water droplet (미세 물방울에서의 공명 유도라만산란의 특성)

  • 문희종;김광훈;임용식;고춘수;이재형;장준성
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.337-344
    • /
    • 1995
  • We have detected the resonant stimulated Raman scattering signal when the Q-switched Nd:YAG laser beam are incident on the $35~62{\mu}m$ sized water droplet as pump beam. The signals appeared as uniformly spaced peaks and the intervals between peaks become narrow as the droplet size increases. Also we have confirmed the morphology dependent resonances (MDR's) characteristic of the stimulated Raman scattering signal when the water droplet becomes nearly spherical shape after two water droplets are coupled to a droplet. The error in the measured intervals between MDR's of same mode order is about 5%.out 5%.

  • PDF