• Title/Summary/Keyword: 공동주파수

Search Result 230, Processing Time 0.026 seconds

A Study on Input Multiplexer for Ku-Band Satellite Transponder (Ku 대역 위성 중계기용 입력 멀티플렉서에 관한 연구)

  • 이주섭;엄만석;염인복;이성팔
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.4
    • /
    • pp.393-400
    • /
    • 2003
  • This paper deals with the design and manufacturing technique of EQM(Engineering Qualification Model) of input multiplexer(IMUX) for the Ku-band satellite transponder. Channel dropping method by circulator chain structure is adopted for demultiplexing each channel. External equalizers are attached behind channel filters fur reduction of group delay variation and amplitude variation simultaneously. Both channel filters and equalizers adopted dual-mode technique in design f3r mass and volume reduction. Channel filters are designed to have 8-pole elliptic response and equalizers to be of 2-pole reflection type. For good temperature stability characteristics, INVAR36 material is used for channel filters and external equalizers. Vibration test, Thermal Vacuum Test, and EMC test have been performed on input multiplexer and it is shown to be suitable for Ku-band satellite transponder.

Sequentially Rotated Array Microstrip Antenna (순차 회전 배열 마이크로스트립 안테나)

  • Han, Jeonng-Se;Lee, Hyun-Sung;Seo, Dong-Kug;Park, Byoung-Woo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.9
    • /
    • pp.1005-1014
    • /
    • 2007
  • In this paper, The four types SRA(Sequential Rotated Array) antennas has been analyzed. Those are consisted of a 4-elements SRA, a 8-elements SRA, the $2{\times}2$ planer array SRA and the triple (4+8+4)-elements SRA. These LHCP SRA antennas are used a probe feeding multi-layer truncated microstrip antenna whose center frequency is 11.85 CHz. The cooperated feeding circuits are designed for feeding to each elements with equal amplitude and regular phase. Comparing with the each simulation results and experiment results of this 4-type SRA antennas, the triple (4+8+4)-elements SRA showed the most electrical characteristics in the degree of integration, high gain and low cross polarization.

Design and Fabrication of 25 W Ka-Band SSPA Based on GaN HPA MMICs (GaN HPA MMIC 기반 Ka 대역 25 W SSPA 설계 및 제작)

  • Ji, Hong-gu;Noh, Youn-sub;Choi, Youn-ho;Kwak, Chang-soo;Youm, In-bok;Seo, In-jong;Park, Hyung-jin;Jo, In-ho;Nam, Byung-chang;Kong, Dong-uk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.12
    • /
    • pp.1083-1090
    • /
    • 2015
  • We designed and manufactured Ka-band SSPA include drive amplifier and high power amplifier MMICs by $0.15{\mu}m$ GaN commercial process. Also, we fabricated main components micro-strip line to WR28 waveguide transition and WR28 wave guide power combiner for Ka-band SSPA. This Ka-band SSPA shows saturated output power 44.2 dBm, power added efficiency 16.6 % and power gain 39.2 dB at 29~31 GHz frequency band.

Design of RISC-based Transmission Wrapper Processor IP for TCP/IP Protocol Stack (TCP/IP프로토콜 스택을 위한 RISC 기반 송신 래퍼 프로세서 IP 설계)

  • 최병윤;장종욱
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.6
    • /
    • pp.1166-1174
    • /
    • 2004
  • In this paper, a design of RISC-based transmission wrapper processor for TCP/IP protocol stack is described. The processor consists of input and output buffer memory with dual bank structure, 32-bit RISC microprocessor core, DMA unit with on-the-fly checksum capability, and memory module. To handle the various modes of TCP/IP protocol, hardware-software codesign approach based on RISC processor is used rather than the conventional state machine design. To eliminate large delay time due to sequential executions of data transfer and checksum operation, DMA module which can execute the checksum operation along with data transfer operation is adopted. The designed processor exclusive of variable-size input/output buffer consists of about 23,700 gates and its maximum operating frequency is about 167MHz under 0.35${\mu}m$ CMOS technology.

Analysis and Technical Consideration for the Rules on Television White Space (TVWS 대역 규정에 관한 분석 및 기술적 고려)

  • Kim, Young-Soo;Cho, Sang-In;Jeong, Byung-Jang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.8
    • /
    • pp.923-933
    • /
    • 2012
  • In this paper, we propose the technical considerations for the rules on television white space(TVWS), that becomes a center of public notice, in terms of incumbent services protection, technical requirements of television band devices (TVBDs) and administration of TV band databases. The basic idea behind the proposed method is based on the perfect protection of incumbent services such as digital television and wireless microphone. It has been found that FCC's approach has the advantage that a list of available channels and transmission power are provided for TVBDs faster than Ofcom's approach that requires DB to perform the algorithm for determining frequencies and transmission power for TVBDs everytime DB is asked from TVBDs.

AE Characteristic under Tensile of Carbon Steel for High-Pressure Pipe (고압배관용 탄소강의 인장시 음향방출 특성)

  • Nam Kiwoo;Lee Siyoon
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.2 s.19
    • /
    • pp.48-53
    • /
    • 2003
  • This study is to look at the effect for deformation of carbon steel for high-presure pipe, on the AE signals produced by tensile test. Acoustic emission(AE) has been widely used in various fields because of its extreme sensitivity, dynamic detection ability and location of growing defects. We investigated a relationship failure mode and AE signals by tensile test, From the tensile test, we could divide into four ranges of the failure modes of elastic range, yield range, plastic range before $\sigma$u, plastic range after $\sigma$u. And failure behaviors of elastic range, yield range, plastic range before $\sigma$u, plastic range after $\sigma$u could be evaluated in tensile test by AE counts, accumulation counts and time frequency analysis. It is expected to be basic data that can protect a risk according to tensile test and bending of pipe material for pressure vessel, as a real time test of AE.

  • PDF

Emergency Broadcast System Using Radio and DMB for Tunnel and Underground (라디오와 DMB 방송을 이용한 터널 및 지하차도용 비상방송시스템)

  • Do, Daewook;Lee, Choong Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.392-394
    • /
    • 2019
  • Tunnels and subterranean roads, which are representative evacuation facilities for national or regional disasters, have radio relay broadcasting facilities for legal reasons and convenience reasons. However, this system is limited to radio broadcasting and it is impossible to effectively communicate disaster or emergency situations that occur locally due to broadcasting of national broadcasting without DMB broadcasting. In order to improve this, we construct a remote disaster broadcasting system at each regional disaster station and implement a system to transmit it to each tunnel using internet or LTE network. The system in the tunnel transmits the emergency broadcasting signal through the existing relay equipment through the modulator which decodes the SMS, the media file, the real time broadcasting or the image received by the digital signal and converts it into FM and DMB frequency. The method proposed and implemented in this study can be used to provide efficient information and remote field control in case of emergency in tunnel and underground roadway.

  • PDF

Measurement of the Quantity of Hydrogen Peroxide Produced in the Ultrasound-irradiated Aqueous Solution of Organic Compounds (초음파를 조사(照射)한 유기화합물 수용액 속에서의 과산화수소 생성량의 측정)

  • Mo, Se-Young;Chang, Hong-Ki;Lee, Kyung-Jae;Jang, Gun-Eik;Sohn, Jong-Ryeul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.61-71
    • /
    • 2000
  • When irradiate the power ultrasound into the aqueous solutions, water vapor is decomposed by the heat of very high temperature in the cavitation bubble to produce OH (hydroxyl radical) and H (hydrogen radical), and these radicals play a role in decomposing the substances in aqueous solution by oxidation and/or reduction, and in producing the hydrogen peroxide. Accordingly it is possible to predict that the quantity of hydrogen peroxide produced may correlate with the sonolysis mechanism of the substance in aqueous solution. Thus to confirm this prediction, the quantities of hydrogen peroxide produced from each of the air saturated distilled water and three aqueous solutions of TCE, benzene, and 2,4-DCP that are prepared by dissolving them into distilled water are measured. As a result, it showed that the quantity of hydrogen peroxide produced from the distilled water and three aqueous solutions are increased in order of distilled water>TCE solution>2,4-DCP solution>benzene solution, and decrease with decrease in concentration of organic substance, which coincide with the sonolysis mechanisms reported that TCE in aqueous solution is decomposed directly by the pyrolysis in and around the cavitation bubbles when its concentration is high and by the radical reaction when low, however, benzene and 2,4-DCP are decomposed not only by the pyrolysis but also by the radical reactions. Effects of such experimental parameters as the acoustic frequency and power and as the concentration showed that the higher the acoustic frequency and the lower the acoustic power, the less the quantity of hydrogen peroxide was produced. This result coincide with the theory of ultrasound for the relation between the cavitation that is the energy source of the power ultrasound in aqueous solution and these experimental parameters.

  • PDF

Monitoring North Korea Nuclear Tests: Comparison of 1st and 2nd Tests (북한 핵실험 모니터링 : 1, 2차 비교)

  • Chi, Heon-Cheol;Park, Jung-Ho;Kim, Geun-Young;Che, Il-Young;Sheen, Dong-Hoon;Shin, Jin-Soo;Cho, Chang-Soo;Lee, Hee-Il
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.3
    • /
    • pp.243-248
    • /
    • 2010
  • Two suspicious events, which were claimed as underground nuclear tests by North Korea, were detected in the northern Korean Peninsula on October 9, 2006 and May 25, 2009. The KIGAM and Korea-China Joint seismic stations are distributed uniformly along the boundaries between North Korea and adjacent countries. In this study, the data from broadband stations with the distance of 200 to 550 km from the test site are used to analyze and compare two nuclear tests of North Korea. By comparing the time differences of the Pn-wave arrival times of 1st and 2nd tests at multiple stations, the relative locations of two test sites could be calculated precisely. From the geometrical calculation with the velocity of Pn wave $V_{Pn}$ = 8 km/s, the 2nd test site is estimated to move in the WNW direction from 1st one with the distance of 2 km. Body wave magnitude, mb of the 2nd test, which was announced officially as the network average of 4.5, varies widely with the directional location of stations from 4.1 to 5.2. The magnitude obtained from Lg wave, $m_b$(Lg), shows less variation between 4.3 to 4.7 with the average of 4.6. The moving-window spectra of time traces of 1st and 2nd tests show very similar pattern with different scale level. In addition, the corner frequencies of P wave of 1st and 2nd tests at each station show no or negligible difference. This indicates the burial depths of two tests might be very similar. The relative yield amount of the 2nd test is estimated 8 times larger than that of the 1st from the weighted average of ground-velocity amplitude ratios.

THE MEASUREMENT OF THE IONOSPHERIC TOTAL ELECTRON CONTENT USING P-CODE OF GPS (GPS의 P 코드를 이용한 이온층의 총전자수 측정)

  • 서윤경;박필호;박종욱;이동훈
    • Journal of Astronomy and Space Sciences
    • /
    • v.11 no.1
    • /
    • pp.71-80
    • /
    • 1994
  • It is generally known that the measurement of the ionospheric total electron content(TEC) by GPS can more accurately monitor the broader area of the ionosphere than other current methods. \Ve measured the TEC along a slant path considering the arrival time differences of P-code which is transmitted from GPS satellites with the modulation on two L-band carrier frequencies, L1 (1574.42MHz) and L2 (1227.60MHz). Under the assumptions that the ionosphere is uniformly distributed and its average height is 350km, we transformed the slant TEC to the vertical TEC at the point that the line-of-sight direction to GPS satellite cut across the average height of the ionosphere. Because there is no dual frequency P-code GPS receiver in Korea, we used the data observed at the TAIW GPS station ($N25^{\circ},E121.5^{\circ}$) in Taiwan which is one of the core stations in International GPS and Geodynamics Services (IGS). The TEC values obtained in this work showed a typical daily variation of the ionosphere which is high in the daytime and low in the nighttime. Our results are found to be consistent with the SOLAR-DAILY data of NOAA and the Klobuchar's model for the ionospheric correction of GPS. In addition, in the cornparision with SOLAR-DAILY data, we estimated the precision of our TEC measurement as 2 TEC.

  • PDF