• Title/Summary/Keyword: 공기-물

Search Result 1,734, Processing Time 0.029 seconds

A Study on the Visualization of Urban Wind Flow by Using Thermochromic Pigment (열변색성 염료를 이용한 도심 공기 유동 시각화에 관한 연구)

  • Kim, Hong-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.11
    • /
    • pp.291-299
    • /
    • 2021
  • Recently, due to environmental problems caused by densification and high rise of urban areas, interests in air flow is increasing and appropriate shape and layout design of buildings is required. Therefore, in this study, we intend to propose an experimental method that can observe the air flow around a building using thermochromic pigment. Thermochromic pigments have limitations in observing precise temperature changes due to the characteristic that the color changes only with respect to a specific temperature, but they have the advantages of easy configuration of experimental equipment and short time required for experiments. In this study, the air flow tendencies around a building was examined by performing CFD analysis for a simple model and then compared with the thermochromic experiment results in order to review the usefulness of the proposed experimental method. As a result of the experiment, it was possible to observe the formation of separated flow and vortex region generated by buildings using the charateristics of thermochromic pigment and it was confirmed that the proposed method can be useful for buildings design and urban city planning.

Performance Evaluation of Weir Structures Under Blast Loads (폭발하중에 의한 다기능-수중보 구조물 거동평가)

  • Jeon, Jun-Tai;Jung, Woo-Young;Ju, Bu-Seog
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.168-169
    • /
    • 2015
  • 최근 위험물질에 의한 폭발 및 테러의 위험성 증가로 인하여 사회간접자본 시설물인 댐/보, 원자력 발전소, 병원 구조물과 같은 주요 시설물의 폭발 안전성 평가 연구가 이슈화 되고 있어, 본 연구에서는 가스폭발에 의한 다기능 보 구조물의 거동을 평가하고 안전성을 분석 하고 자 한다. 본 연구에서 폭발 해석에 필요한 하중 조건 산정은 PHAST 프로그램을 사용하여 주변 온도 및 공기 특성 등을 고려한 약 5톤의 가스 폭발 조건을 구축 하였다. 또한 다기능 보 구조물의 거동 분석을 위해 구조물-지반 상호 작용을 고려한 2차원 유한 요소 모델을 구축하여 폭발에 의한 구조물 거동을 평가 하였다. 다기능 보 구조물의 수치해석 결과 보 구체와 Stilling Basin구조물 사이의 연결부에 응력집중 현상이 발생하는 것으로 평가 되었다.

  • PDF

Static Fluid Structure Interaction Analysis of Wind Turbine Blade Skin Fabric (풍력발전기 블레이드 패브릭 스킨의 정적 유체-구조연성 해석에 관한 연구)

  • An, Hyung-ju;Bae, Jae-sung;Hwang, Jai-hyuk
    • Journal of Aerospace System Engineering
    • /
    • v.10 no.4
    • /
    • pp.1-10
    • /
    • 2016
  • This study analyzes the fabric skin of a wind turbine blade. The fabric skin is a membrane structure that was analyzed using a static Fluid Structure Interaction (FSI) method. For this study the blade of large 5 MW wind turbine was selected. In order to examine the validity of the analysis, a variety of reference data were used. Before conducting static FSI analysis, a Computational Fluid Dynamics (CFD) analysis and modal analysis were done. Then interaction analysis was conducted. FSI analysis was done with imported Aerodynamic data that resulted from the CFD analysis. The resulting observations about the membrane structure, inherent tensions, deformation of the final structure, and aerodynamic forces caused by deformation are reported.

Surfactant Aided Air-sparging for Groundwater Remediation (계면촬성제 첨가에 따른 지하수 폭기법의 폭기효율 변화 연구)

  • 소효은;최경민;이승재;김헌기
    • Economic and Environmental Geology
    • /
    • v.35 no.5
    • /
    • pp.421-428
    • /
    • 2002
  • Lab-scale experiments were conducted to evaluate the effect of surface tension reduction on the extension of the influence zone and the VOC removal efficiency of ground water sparging. A glass column packed with coarse sand was used for VOC removal test at two different surface tensions. A glass column without porous media was also used fer control purpose prior to sand-packed column test. A quasi-two-dimensional glass box model, packed with a sand, was used fer sparging zone tests at different water surface tensions. Surface tension of the aquoues solution used in this study was controlled using sodium dodecyl sulfate (SDS). For the glass, sand column experiments, total amount of air filled in the media increased as surface tension decreased. Toluene (used as VOC in this study) removal rate increased slightly with decreased surface tension f3r both free water column and sand-packed column. Air sparging zone extended up to 500% as the surface tension decreased. Combining the results from two different experiments, VOC removal efficiency is expected to increase significantly with surface tension reduction.

Treatment of Aquacultural Recirculating Water by Foam Separation - II. Characteristics of Solid Removal - (포말 분리법을 이용한 양어장 순환수 처리 - II. 고형물 제거특징 -)

  • SUH Kuen-Hack;LEE Min-Gyu;LEE Min-Soo;KIM Byong-Jin;KIM Eun-Jung;CHO Moon-Chul
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.3
    • /
    • pp.334-339
    • /
    • 1997
  • The feasibility of foam separation to remove solid produced from fish culture water was investigated. Performance characteristics of foam separator were highly dependent upon the operating parameters which were superficial air velocity, Hydraulic retention time (HRT), and foam height. About $50\%$ of the total protein contained in a sample of fish culture water could be removed by foam separator. The removal efficiencies of protein, T-N, TA, and solid components were increased with increasing superficial air velocity and HRT. The combined effects of these operational variables show that removal rates of TVS increase with increasing superficial air velocity and HRT, and decrease as foam height goes up. It could be confirmed that foam separator might offer good perspective for removal of harmful components such as TA and TVS in aquacultural recirculating water.

  • PDF

On the Hydrodynamic Forces acting on a Partially Submerged Bag (부분적으로 물에 잠긴 백에 작용하는 유체역학적 힘)

  • G.J. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.4
    • /
    • pp.104-113
    • /
    • 1992
  • The hydrodynamic problem is treated here when a pressurized bag is submerged partially into water and the end points of it oscillate. SES(Surface Effect Ship)has a bag filled with pressurized air at the stern in order to prevent the air leakage, and the pitch motion of SES is largely affected by the hydrodynamic force of the bag. The shape of a bag can be determined with the pressure difference between inside and outside. Once the hydrodynamic pressure is given, the shape of a bag can be obtained, however in order to calculate the hydrodynamic pressure we should know the shape change of the bag, and vice versa. Therefore the type of boundary condition on the surface of a bag is a moving boundary like a free surface boundary. In this paper, the formulation of this problem was done and linearized. The calculation scheme for the radiation problem of an oscillating bag is shown in comparison with the case that the bag is treated as rigid body. The hydrodynamic forces are calculated for various values of the pressure inside the bag and the submerged depth.

  • PDF

Effect of Air Flow Rate on the Performance of Planar Solid Oxide Fuel Cell using CFD (평판형 고체산화물 연료전지의 CFD 성능해석에서 공기유량변화의 영향)

  • Kim, Danbi;Han, Kyoungho;Yoon, Do-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.4
    • /
    • pp.172-181
    • /
    • 2015
  • Solid Oxide Fuel Cells (SOFC) continue to be among the most promising alternative energy devices. This paper addresses i-V characteristics of SOFC with a focus on air flow rate along the planar anode electrodes. To address this, detailed Butler-Volmer kinetics are implemented in a general-purpose CFD code FLUENT. The numerical results were validated against experimental data from the literature showing excellent match with i-V polarization data ranging 1V-0.4V. Numerical calculations of fuel cell operation under different flow rare conditions were performed in three-dimensional geometries. Results are presented in terms of concentration distribution of hydrogen, oxygen, and water. The simulations and results indicate that advanced CFD with UDF(User-Defined Function) of Butler-Volmer kinetics can be used to identify the conditions leading to air flow rate and specific surface area and guide development of operating conditions and improve the fuel cell system performance.

A study on the Characteristics of a Centrifugal Fan Vibration and Noise (Centrifugal Fan 송풍기의 진동.소음 특성에 관한 연구)

  • 김태형;김옥현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.999-1003
    • /
    • 1992
  • Because of low noise and small size with huge capacity, a centrifugal fan is widely used for ventilation, air-conditioner and so on, which are very near to human life. Because of the complexity of its vibration and noise generation mechanics, most of researches on them are based on experimental methods. This study is to characterize the centrifugal fan noise and vibration. It is considered that noise is composed of the structural vibration noise and the air flow induced aerodynamic noise. To decouple the structural vibration noise the centrifugal fan is masked with an adhesive tape, such that air blowing is prohibited thus only the structural vibration noise is extracted. The noise level and characteristics in the frequency domain are verified and compared with those of total mixed one. This study shows some significant results that the structural vibration noise has relatively narrow band power spectrum compared with the total mixed one and has a strong periodicity. The sound level is lowered about 5dB by the removal of air flow with the masked fan for an air-conditioner used in this study.

Effect of Porous Flow Field on PEMFC Performance with Dead Ended Anode System (Dead ended anode 시스템에서 다공성 유로가 연료전지 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.33 no.6
    • /
    • pp.646-652
    • /
    • 2022
  • The dead-end anode (DEA) system is a method that closes the anode outlet and supplies fuel by pressure. The DEA method could improve fuel usage and power efficiency through system simplification. However, flooding occurs due to water and nitrogen back diffusion from the cathode to the anode during the DEA operation. Flooding is a cause of decreased fuel cell performance and electrode degradation. Therefore, tthe structure and components of polymer electrolyte membrane fuel cell (PEMFC) should be optimized to prevent anode flooding during DEA operation. In this study, the effect of a porous flow field with metal foam on fuel cell performance and fuel efficiency improvement was investigated in the DEA system. As a result, fuel cell performance and purge interval were improved by effective water management with a porous flow field at the cathode, and it was confirmed that cathode flow field structure affects water back-diffusion. On the other hand, the effect of the porous flow field at the anode on fuel cell performance was insignificant. Purge interval was affected by metal foam properties and shown stable performance with large cell size metal foam in the DEA system.

A Numerical Study of Cathode Block and Air Flow Rate Effect on PEMFC Performance (고분자전해질 연료전지의 환원극 블록과 공기 유량 영향에 대한 전산 해석 연구)

  • Jo, Seonghun;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.33 no.1
    • /
    • pp.96-102
    • /
    • 2022
  • Reactants of PEMFC are hydrogen and oxygen in gas phases and fuel cell overpotential could be reduced when reactants are smoothly transported. Numerous studies to modify cathode flow field design have been conducted because oxygen mass transfer in high current density region is dominant voltage loss factor. Among those cathode flow field designs, a block in flow field is used to forced supply reactant gas to porous gas diffusion layer. In this study, the block was installed on a simple fuel cell model. Using computational fluid dynamics (CFD), effects of forced convection due to blocks on a polarization curve and local current density contour were studied when different air flow rates were supplied. The high current density could be achieved even with low air supply rate due to forced convection to a gas diffusion layer and also with multiple blocks in series compared to a single block due to an increase of forced convection effect.