• 제목/요약/키워드: 공기 혼합시스템

Search Result 98, Processing Time 0.025 seconds

Design and Manufacture of the air mixing system for supersonic ground test facility (초음속 지상추진시험설비의 공기 혼합시스템 설계 및 제작)

  • Lee, Yagn-Ji;Kang, Sang-Hun;Yang, Soo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.40-48
    • /
    • 2008
  • Air mixing system which is composed of air pressure control system, hot pipe system and air mixer, is the facility for mixing hot air($1000^{\circ}C$, 10kg/s) from storage air heater (SAH) and decompressed air($20^{\circ}C$, 15kg/s) from high pressure air supply system. Air pressure control system reduce the pressure of the air, from 32MPa to 3.5 MPa and supply the decompressed air to air mixer. The hot pipe system supply hot air from SAH to air mixer which mix hot with the decompressed air from air pressure control system. Fully mixed air flow rate is 25kg/s and mixed temperature is up to $400^{\circ}C$. So, we can expand the operating envelop of the supersonic ground test facility to low Mach number and low altitude region.

  • PDF

가스터빈/연료전지 혼합형 발전시스템의 국내외 기술개발 동향

  • 김재환;양수석
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.32 no.11
    • /
    • pp.26-31
    • /
    • 2003
  • 가스터빈/연료전지 혼합형 발전시스템은 고온형 연료전지 발전시스템의 산화제(공기) 공급부가 마이크로터빈으로 대체되어 고온고압의 공기가 연료전지로 공급되고 연료전지의 반응가스가 터빈을 구동하여 두 시스템이 동시에 서로 다른 방식으로 전력을 생산하는 시스템을 의미한다.

  • PDF

환경관련 특허동향 - 화장실의 중수도 시스템(해성엔지니어링)

  • 한국환경기술인연합회
    • Environmental engineer
    • /
    • s.328
    • /
    • pp.92-96
    • /
    • 2013
  • 본 발명은 화장실의 세면대에서 사용된 세척수 및 하수를 중수도 수질기준에 적합하도록 처리하여 화장실 용수로 재활용하는 화장실의 중수도 시스템에 관한 것이다. 화장실의 중수도 시스템의 구성을 살펴보면, 세면대에서 사용된 세척수 및 하수가 유입되는 반응조와, 상기 반응조로 유입된 세척수 및 하수를 살균 및 소독하는 마이크로버블 오존 발생장치와, 살균 및 소독된 처리수를 정장하는 처리수조와, 상기 처리수조에 저장된 처리수를 화장실 용수로 공급하는 용수공급펌프를 포함한다. 이 중에서 상기 마이크로버블 오존 발생장치는, 외부에서 유입된 공기를 정화하는 에어필터와, 상기 에어필터에서 정화된 공기를 공급하는 에어펌프와, 상기 에어펌프를 통해 유입된 공기에 자외선을 조사하여 오존을 발생시키는 오존발생기와, 상기 오존발생기에서 발생된 오존을 세척수 및 하수에 혼합시키는 기액혼합펌프와 상기 오존과 상기 세척수 및 상기 하수의 혼합 효과를 극대화하기 위한 라인믹서로 구성된다. 이와 같이 구성된 본 발명에 의한 화장실의 중수도 시스템은 상수(上水)의 소비량을 줄이고 하수(下水)의 발생량을 감소시켜 경비절감의 효과를 얻을 수 있고, 지하수의 고갈 및 생활용수의 증가에 따른 물 부족 현상에 대해 능동적으로 대처할 수 있다. 특히, 재활용된 화장실 용수에는 오존이 함유되어 화장실 내의 악취제거, 살균 및 소독효과가 있으며, 외부로 배출되는 세척수 및 하수에 포함된 유지성분을 제거하여 환경오염을 방지할 수 있다.

  • PDF

산소농도 측정을 위한 $UO_{2}$ 펠릿 공기산화로 장치의 갈바닉 센서와 지르코니움 센서의 특성 연구

  • Kim, Yeong-Hwan;Jeong, Jae-Hu;Lee, Hyo-Jik;Park, Byeong-Seok;Yun, Ji-Seop
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2007.05a
    • /
    • pp.151-152
    • /
    • 2007
  • ACP(Advanced Spent Fuel Conditioning Process)의 금속전환로에 $U_{3}O_{8}$을 공급하기 위하여 20 kgHM/batch의 $UO_{2}$ 펠릿(pellets)을 처리할 수 있는 공기산화로가 개발되고 있다. 그림 1은 산소농도 조절이 가능한 공기산화로이다. 공기산화로 이전의 공정인 슬리팅 장치에서 탈피복된 $UO_{2}$ 펠릿은 공기산화로로 운반되고, $500^{\circ}C$온도에서 공기를 공급하여 일정한 입도범위의 균질한 $U_{3}O_{8}$을 만든다. 그리고 다음공정의 금속전환장치로 이동된다. 본 논문에서는 모의연료의 산화에 대한 정확한 산소농도를 측정하고자 한다. 이를 위해서 갈바닉 센서와 지르코니움 센서가 사용되었고, 그 특성이 비교되었다. 14종의 금속 산화물이 혼합된 모의연료를 제조하여 산화실험이 수행되었으며, 시간변화에 따라 산소농도가 측정되었다. 산소농도 컨트롤러와 산소 센서를 사용한 공기산화로는 산소조절기에 의해 산소농도 100%까지 측정될 수 있다. 그림 2는 공기산화로의 산소농도를 조절할 수 있는 산소농도 측정시스템이다. 유량조절기(Mass Flow Controller)를 사용하여 질소와 산소의 혼합비를 변화시킬 수 있다. 또한 산소농도 측정시스템은 측정된 산소농도 값을 이용하여 $UO_{2}$의 산화시간을 계산하기 위하여 제작하였다. 산화시간 계산방법은 다음과 같다. 산소와 질소의 가스는 각각 40 L의 압력 봄베에 의해서 산소농도를 조절할 수 있는 공기산화로의 산소농도 측정시스템 안으로 유입된다. 유입된 산소와 질소의 배합은 컨트롤시스템 안에 있는 산소 유량조절기와 질소 유량 조절기를 사용하여 조절하며, 일정하게 혼합된 산소농도는 장치의 입구와 출구에서 산소 센서에 의해서 측정된다. 투입된 $UO_{2}$ 펠릿이 $500^{\circ}C$에서 반응하면서 공기산화로의 내부에 있는 산소농도가 감소된다. 이때 초기에 같았던 입력과 출력 농도가 시간의 흐름에 따라 감소되며, 펠릿이 완전히 산화됨과 동시에 출력 산소농도가 입력농도와 다시 같아질 때까지 소요된 구간이 산화시간이 된다.

  • PDF

Implemetation of Waterpipe Clean Control System for Dental Clinic Unit-chair (치과용 유니트체어에 적용 가능한 수관 세척 제어시스템 구현)

  • Yun, Hyun-Su;Park, Ji-Hyun;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.760-761
    • /
    • 2011
  • 본 연구에서는 치과용 유니트체어의 용수공급 시스템 중 수관 내부에 생성되는 바이오필름을 보다 효율적으로 제거하기위하여 공기와 물을 혼합한 버블을 생성하고 가변적인 압력을 인가하여 살균과 세척을 동시에 수행할 수 있는 시스템을 개발하고자 하였다. 이를 위하여 공기와 물의 혼합 세척을 통한 바이오필터 세척 및 전기분해를 이용한 용수 살균 시스템을 구현하였으며, 물과 공기의 흐름제어 및 가변적인 압력 조절 제어시스템을 구현하였다. 그리고 무선으로 제어가 가능한 솔레노이드밸브로 구성된 벨브조립체를 구성하여 세척모드 및 용수공급모드의 선택적 운용이 가능한 시스템을 구현하였다.

  • PDF

Combustion and Spray Characteristics of Jet in Crossflow in High-Velocity and High-Temperature Crossflow Conditions (고온고속기류 중에 수직 분사되는 액체제트의 연소 및 분무특성)

  • Yoon, Hyun Jin;Ku, Kun Woo;Kim, Jun Hee;Hong, Jung Goo;Park, Cheol Woo;Lee, Choong Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.67-74
    • /
    • 2013
  • A jet in a crossflow (JICF) has been extensively studied because of its wide applications in technological systems, including fuel injection into a ram-combustor. However, in the case of insufficient mixing performance of the liquid jet into the crossflow, the flame in a ram-combustor is unstable. In this study, the nonuniform flame and combustion instabilities due to lack of mixing performance were experimentally investigated. By performing correlations to predict the penetration height and break-up point, the spray and mixing characteristics of JICF have been studied. In particular, the improved correlations of penetration height are proposed in two distinctive domains depending on the X/d location of the crossflow.

A Study of Establishment on the Compressed-Air Foam System (압축공기포 시스템 성능시험 연구)

  • Lim, Woo-Sub;SaKong, Seong-Ho;Lee, Jang-One;Jeong, Jae-Han;Nam, Jun-Seok;Nam, Dong-Gun;Na, Yong-Un;Park, Kyung-Hwan;Lee, Nae-Hun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.506-509
    • /
    • 2011
  • 압축공기 포는 공기포혼합기를 사용하여 약제와 물 그리고 압축공기를 혼합하여 방출하는 방식으로, 물의 확보가 곤란한 장소라도 소화 효율을 높이는 시스템으로서 주목되고 있으며, 현재 해외 선진국에서는 이미 개발되어 상용화 되어있다. 본 연구에서는 국제적 기준에 따른 압축공기포소화설비의 성능평가시험을 위해 미국, 캐나다 등에서 채택한 UL-162 시험방법을 적용하여 시험을 수행하였으며, 그 결과 기존의 포소화시스템과 압축공기포소화시스템의 성능비교시험을 통해 압축공기포가 기존의 포소화방식 보다 소화성능이 우수한 것으로 나타났다.

  • PDF

The Indoor Air Purification System Using LED and Fan for Epipremnum aureum (스킨답서스에 LED와 Fan을 이용한 실내공기정화 시스템)

  • Kim, Taehyun;Park, Junmo;Kim, Soochan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.4
    • /
    • pp.167-173
    • /
    • 2018
  • We propose an air purification system that utilizes aerial plant parts and root zone of indoor plants where light is insufficient and air circulation is bad. In order to maximize the air purification effect of the plant, the aerial plant parts illuminates mixed light combining blue and green LED and CRI(Color Rendering Index) LEDs close to natural light, respectively. And the root zone was forcibly circulated by the fan to use the soil as a filter. The indoor air purification system combined with the light source and the fan removed most polluted air in the shortest. In the case of mixed light and CRI LEDs of indoor air purification system, fine dust decreased by 14%, 14.2%, and TVOC(Total volatile organic compounds) decreased by 7.5% and 9.4%, respectively. In the experiment in which the fan was operated for 15 minutes, the TVOC decreased to 97.8%. The photosynthesis of the plant and the use of soil as a filter were able to purify polluted air in a short time. And the fan's temporary operation gave the similar effect of continuous operation.

A Preliminary Study of Low Temperature Condition by Heat Exchanger (열교환기를 이용한 저온 환경 구축에 대한 기초 연구)

  • Lee, Yang-Suk;Yang, Jae-Joon;Kim, Yoo;Ko, Young-Sung;Lim, Byeung-Jun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.23-26
    • /
    • 2007
  • A preliminary, study of low temperature condition was performed to simulate high altitude condition. The mixed air temperature were investigated at various condition by experiments using cryogenic air by heat exchanger and normal temperature air. An experimental setup was constructed to simulate low temperature condition with liquid nitrogen. To control mass flow rate, orifice and pressure regulators were used. The experimental results show that the mixed air temperature increases linearly with mass flow rate of normal temperature air. Therefore it can be help to simulate a low temperature condition of high altitude.

  • PDF

Investigation of the Mixedness of Fuel and Air in MEMS Gas Turbine Engine According to Change of Fuel Injectors and Equivalence Ratio (연료 분사구 형상 변화 및 당량비 변화에 따른 MEMS 가스터빈 내 연료-공기 혼합에 관한 연구)

  • Hwang, Yu-Hyeon;Jung, Dong-Ho;Kim, Sun-Min;Kim, Dae-Joong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.9
    • /
    • pp.835-841
    • /
    • 2010
  • The design of the fuel injector is one of the important operating factors that determine the extent of mixing of air and fuel in an MEMS gas turbine engine. In this study, we consider a system with three inlet ports with each port having multiple injectors. We perform a parametric study by varying the arrangement of fuel injectors and difference of ratio of fuel supply. The results are presented in terms of the premixed flow distribution and equivalence ratio.