• Title/Summary/Keyword: 공기 예측

Search Result 651, Processing Time 0.042 seconds

Frostfall Forecasting in the Naju Pear Production Area Based on Discriminant Analysis of Climatic Data (기후자료 판별분석에 근거한 나주 배 생산지 서리발생 예측)

  • Han, Jeom-Hwa;Choi, Jang-Jeon;Chung, U-Ran;Cho, Kwang-Sik;Chun, Jong-Pil
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.4
    • /
    • pp.135-142
    • /
    • 2009
  • In order to predict frostfall, nocturnal cooling rate and air temperature changes were analyzed on days with and without frost when the maximum temperature was lower than $20^{\circ}C$. In general, the nocturnal cooling rates on frosty days were higher than those on non-frosty days. The cooling rates averaged from 19:00 to 24:00 on frosty and non-frosty days were $1.7^{\circ}Ch^{-1}$ and $0.7^{\circ}Ch^{-1}$ respectively. As expected, the nocturnal temperature on frosty days was lower than that on non-frosty days. Especially, the midnight air temperature averaged about $3.9{\pm}1.5^{\circ}C$ on frosty days, which was lower than that on non-frosty days (i.e., $10.1{\pm}2.9^{\circ}C$). The discriminant analysis using three independent variables (i.e., total cloud amount, air temperature at 24:00, and 5-day rainfall amount) successfully classified the presence of frost with 87% accuracy.

Estimation of Uranium Particle Concentration in the Korean Peninsula Caused by North Korea's Uranium Enrichment Facility (북한 우라늄 농축시설로 인한 한반도에서의 공기중 우라늄 입자 농도 예측)

  • Kwak, Sung-Woo;Kang, Han-Byeol;Shin, Jung-Ki;Lee, Junghyun
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.127-133
    • /
    • 2014
  • North Korea's uranium enrichment facility is a matter of international concern. It is of particular alarming to South Korea with regard to the security and safety of the country. This situation requires continuous monitoring of the DPRK and emergency preparedness on the part of the ROK. To assess the detectability of an undeclared uranium enrichment plant in North Korea, uranium concentrations in the air at both a short and a long distance from the enrichment facility were estimated. $UF_6$ source terms were determined by using existing information on North Korean facility and data from the operation experience of enrichment plants from other countries. Using the calculated source terms, two atmospheric dispersion models (Gaussian Plume Model and HYSPLIT models) and meteorological data were used to estimate the uranium particle concentrations from the Yongbyon enrichment facility. A maximum uranium concentration and its location are dependent upon the meteorological conditions and the height of the UF6 release point. This study showed that the maximum uranium concentration around the enrichment facility was about $1.0{\times}10^{-7}g{\cdot}m^{-3}$. The location of the maximum concentration was within about 0.4 km of the facility. It has been assumed that the uranium sample of about a few micrograms (${\mu}g$) could be obtained; and that few micrograms of uranium can be easily measured with current measurement instruments. On the contrary, a uranium concentration at a distance of more than 100 kilometers from the enrichment facility was estimated to be about $1.0{\times}10^{-13}{\sim}1.0{\times}10^{-15}g{\cdot}m^{-3}$, which is less than back-ground level. Therefore, based on the results of our paper, an air sample taken within the vicinity of the Yongbyon enrichment facility could be used to determine as to whether or not North Korea is carrying out an undeclared nuclear program. However, the air samples taken at a longer distance of a few hundred kilometers would prove difficult in detecting a clandestine nuclear activities.

Environmental Prediction in Greenhouse According to Modified Greenhouse Structure and Heat Exchanger Location for Efficient Thermal Energy Management (효율적인 열에너지 관리를 위한 온실 형상 및 열 교환 장치 위치 개선에 따른 온실 내부 환경 예측)

  • Jeong, In Seon;Lee, Chung Geon;Cho, La Hoon;Park, Sun Yong;Kim, Seok Jun;Kim, Dae Hyun;Oh, Jae-Heun
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.278-286
    • /
    • 2021
  • In this study, based on the Computational Fluid Dynamics (CFD) simulation model developed through previous study, inner environmenct of the modified glass greenhouse was predicted. Also, suggested the optimal shape of the greenhouse and location of the heat exchangers for heat energy management of the greenhouse using the developed model. For efficient heating energy management, the glass greenhouse was modified by changing the cross-section design and the location of the heat exchanger. The optimal cross-section design was selected based on the cross-section design standard of Republic of Korea's glass greenhouse, and the Fan Coil Unit(FCU) and the radiating pipe were re-positioned based on "Standard of greenhouse environment design" to enhance energy saving efficiency. The simulation analysis was performed to predict the inner temperature distribution and heat transfer with the modified greenhouse structure using the developed inner environment prediction model. As a result of simulation, the mean temperature and uniformity of the modified greenhouse were 0.65℃, 0.75%p higher than those of the control greenhouse, respectively. Also, the maximum deviation decreased by an average of 0.25℃. And the mean age of air was 18 sec. lower than that of the control greenhouse. It was confirmed that efficient heating energy management was possible in the modified greenhouse, when considered the temperature uniformity and the ventilation performance.

Comparison between Soil Drainage Experiment and Finite Element Analysis for Air Diffusion in Multiphase Porous Media (다공성 매질내의 공기압 확산에 대한 실내 배수시험과 유한요소해석 비교분석)

  • Kim, You-Seong;Kim, Jae-Hong;Kim, Tae-Heon;Lee, Jin-Kwang
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.2
    • /
    • pp.77-85
    • /
    • 2014
  • The paper presents comparison between numerical and experimental results to verify finite element algorithm of air diffusion in three-phase porous media. The theory of two-phase flow in partially saturated soil is a fundamental study to predict the safety for $CO_2$ sequestration. Geotechnical engineering problems exposed to atmospheric pressure generally assume that air pressure is equal to zero in three-phase porous media, but the geotechnical engineering problem at a depth of about over 1 km needs to be considered in connection with deformable solid skeleton due to air pressure. Therefore, the objective of this study is to validate the numerical algorithm by comparing with results obtained from measurement of air diffusion and dissipation through drainage test.

A Study on Condensation Heat Transfer in Air Pre-heating Heat Exchanger using Hydrophilic Surface (친수성 표면 처리를 통한 공기 예열 열교환기의 응축 열전달 성능 연구)

  • Park, Jae Won;Hwang, Sueng Sik;Seok, Sung Chul;Shin, Dong Hoon;Chung, Tae Yong;Son, Sueng Gil
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.191-197
    • /
    • 2014
  • To increase the heat transfer rate of the air pre-heating heat exchanger used for the condensing boiler, We investigated condensation heat transfer coefficients through plasma surface treatment. The hydrophilic surface showed about 10% increase in heat transfer rate than original plate. It shows that Shah correlation can be used to predict the condensation heat transfer coefficient on the original surface within 10% error range after the compatison between Shah correlation and the condensation heat transfer coefficients measured on the hydrophilic surface and original surface. Therefore, we have shown that Shah correlation is available when designing the air pre-heating heat exchanger using the original surface in this study.

Nitrogen-Oxygen Separation Characteristics by Polyimide Membrane System for Controlled Atmosphere Storage (CA저장을 위한 폴리이미드 막 시스템의 질소-산소 분리특성)

  • 이호원;현명택;고정삼
    • Food Science and Preservation
    • /
    • v.5 no.3
    • /
    • pp.239-246
    • /
    • 1998
  • Polyimide membrane system was designed for manufacturing nitrogen-enriched gas, and basic technical data was suggested for appling this system to controlled atmosphere storage. The permeability characteristics of pure oxygen and nitrogen could be explained by dual-mode sorption model. There was substantial decrease in the permeation rates of oxygen, which is the more permeable gas, through the polyimide membrane due to the presence of nitrogen in comparison with pure oxygen. However, the permeation rates of nitrogen was increased by the presence of oxygen. The ideal separation factor was in the range of 5 to 6 in the range of temperature and pressure difference studied, and the separation factor of air was lower than the ideal separation factor. The increase of ideal separation factor with increasing temperature is due to the fact that the activation energy for oxygen is larger than that for nitrogen. Nitrogen concentration decreased rapidly with increasing product recovery, and it was found that this is a major operating factor to obtain nitrogen concentration required for controlled atmosphere storage. A relation equation, by which nitrogen concentration in storehouse can be predicted, was suggested under the establishment of a hypothetical model for controlled atmosphere storage process using polyimide membrane system.

  • PDF

CFD and experiment validation on aerodynamic power output of small VAWT with low tip speed ratio (저속 회전형 소형 수직축 풍력발전기의 공기역학적 출력에 대한 CFD 및 실험적 검증)

  • Heo, Young-Gun;Choi, Kyoung-Ho;Kim, Kyung-Chun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.330-335
    • /
    • 2016
  • In this study, aerodynamic characteristics of the blades of a helical-type vertical axis wind turbine(VAWT) have been investigated. For this purpose, a 100-W helical-type vertical axis wind turbine was designed using a design formulae, and a 3D computational fluid dynamics analysis was performed considering wind tunnel test conditions. Through the results of the analysis, the aerodynamic power output and flow characteristics of a helical blade were confirmed. In order to validate the aerodynamic power output obtained through the analysis, a wind tunnel test was performed by using a full-scale helical-type vertical axis wind turbine. The 3D analysis technique was validated by comparing its results with those obtained from the wind tunnel test.

Influence of the Global Warming in Domestic Construction Schedules (지구온난화가 국내 건설 공기에 미치는 영향에 관한 연구)

  • Chae, Hee-Mann;Cho, Sung-Woo;Yang, Chang-Hyun;Son, Chi-Soo;Kim, Kyung-Hwan;Kim, Jae-Jun
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.567-570
    • /
    • 2007
  • Recent changes of the climate, which caused by global warming, have much effect world-widely. Korea also has struggled with these kinds of weather problems, and construction industry couldn't get away with them, either. However, the research, regarding to these problems, has not been quite settled, yet. Therefore, this study is to find out how the global warming can affect construction periods. As a result, we could recognize that changes of climate, which caused by global warming, also affects non-working days, too. This study is expected to be used as the data to find out the relationship between weather changes and domestic construction industry in the future.

  • PDF

Heat-Transfer Performance Analysis of a Multi-Channel Volumetric Air Receiver for Solar Power Tower (타워형 태양열 발전용 공기흡수기의 열전달 성능해석)

  • Jung, Eui-Guk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.277-284
    • /
    • 2012
  • In this study, a heat-transfer performance analysis is carried out for a multi-channel volumetric air receiver for a solar power tower. On the basis of a series of reviews regarding the relevant literature, a calculation process is proposed for the prediction of the wall- and air- temperature distributions of a single channel at given geometric and input conditions. Furthermore, a unique mathematical model of the receiver effectiveness is presented through analysis of the temperature profile. The receiver is made of silicon carbide. A total of 225 square straight channels per module are molded to induce the air flow, and each channel has the dimensions of $2mm(W){\times}2mm(H){\times}0.2mm(t){\times}320mm(L)$. The heat-transfer rate, temperature distribution and effectiveness are presented according to the variation of the channel and module number under uniform irradiation and mass flow rate. The available air outlet temperature applied to the solar power tower should be over $700^{\circ}C$. This numerical model was actually used in the design of a 200 kW-level commercial solar air receiver, and the required number of modules satisfying the thermal performance could be obtained for the specified geometric and input conditions.

Thermal and Fluid Analyses of Inner Air at Decomposition Equipment on the Waste Gas of Perfluorinated Compounds (과불화 화합물 폐가스에 대한 분해 장치에서의 내부 공기의 열유동해석)

  • You, Jeong-Bong;Kim, Young-Chun;Cho, Jae-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1375-1380
    • /
    • 2015
  • Nowadays, the technique to deal with the waste gas of perfluorinated compounds using plasma has been developed. As the effective decomposition techniques at many research centers and companies were investigated at home and abroad, the products have been improved with various methods. This study aims to guess the distributions of pressure and temperature through the thermal and fluid analyses inside the decomposition equipment model of waste gas. As the analysis result, the maximum pressure and the minimum pressure are 0.975Pa and -1.037Pa individually on the whole. It is shown that the pressure of air decreases gradually as the air flows from inlet to plane 1 and the pressure increases as the air flows from plane 1 to outlet. And the maximum temperature and the mimum temperature are $1718^{\circ}C$$26.07^{\circ}C$ individually on the whole. It is shown that the temperature of air increases gradually as the air flows from inlet to plane 4 and the temperature decreases as the air flows until outlet. It is thought that the data necessary to develop the real system can be applied by using the thermal and fluid analyses.