• Title/Summary/Keyword: 공기투수계수

Search Result 33, Processing Time 0.026 seconds

Impervious Surface as a Thematic Parameter of Analysis for Childhood Asthma Hospitalizations : Spatio-temporal Approaches (소아천식 유병율 분포의 분석변수로서 불투수면 : 시공간적 접근)

  • Um, Jung-Sup
    • Journal of the Korean association of regional geographers
    • /
    • v.16 no.6
    • /
    • pp.706-723
    • /
    • 2010
  • The impervious surface was frequently employed as a proxy of the total environmental burden in the urban area. The impervious surface was extracted from a satellite image and the GIS (Geographical Information System) database for childhood asthma hospitalizations was generated for a total of 62,136 children using the National Health Insurance database of South Korea. Children living in an impervious environment do result in almost twice as many hospitalizations (26.58%) for asthma, as compared to the sub-urban pervious living (15.82%). Furthermore, the risk zones with persistently high hospitalizations for three years were specifically identified over the impervious sub-district alone. The impervious zone showed a small inter-year variation of hospitalizations (r: 0.937) while the sub-urban pervious fringe was found to display a yearly variation(r: 0.371). The strong temporal autocorrelation means that the impervious areas have frequent long-lived hospitalizations for asthma, thus children living in impervious areas were likely to have had more chronic asthma attacks than those living in pervious areas. These experimental results indicate that an impervious surface as thematic parameter of analysis is a crucial explanatory variable for asthma hospitalizations and its longer persistence among children.

  • PDF

Implementation of Infinite Boundary Condition Considering Superposed Theory on SVE Remediation System (토양증기추출복원 시스템에서 중첩이론을 고려한 무한 경계조건 실행)

  • Park, Jeong-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.3
    • /
    • pp.9-16
    • /
    • 2007
  • Soil vapor extraction (SVE) is an effective and cost efficient method of removing volatile organic compounds (VOCs) and petroleum hydrocarbons from unsaturated soils. Incorporating PVDs in an SVE system can extend the effectiveness of SVE to lower permeability soils by shortening the air flow-paths and ultimately expediting contaminant removal. With this approach, the real bounded system is replaced for the purposes of analysis by an imaginary system of infinite areal extent. The boundary conditions for the contaminant remediation model test include constant head and no flow condition. Due to these parallel boundaries conditions, image wells should be developed in order to maintain the condition of no flow across the impermeable boundary. It is also assumed that the flow is drawdown along the constant head boundary condition. The factors contributing to the difference between the theoretical and measured pressure heads were also analyzed. The flow factor increases as the flow rate is increased. The flow rate is the most important factor that affects the difference between the measured and theoretical pressure heads.

  • PDF

Effect of Air Void and Strength Characteristics with Freezing and Thawing Resistance on High Strength Concrete (고강도(高强度) 콘크리트에서 기포조직(氣泡組織) 및 강도특성(强度特性)이 연결융해저항(連結融解抵抗)에 미치는 영향(影響))

  • Kim, Saeng Bin;Moon, Je Kil;Kim, Dong Sin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.13-24
    • /
    • 1993
  • The influence of the bubble structure and strength characteristics on the freeze-thaw resistance of high strength concrete is investigated by the laboratory experiment. The test conditions are formed in the manner that water is continueusly supplied externally and the specimens were received severe weather actions from ordinary to significantly low temperatures. The experiments are performed in two stages. In the first stage, the relation between the durability to frost action and the bubble structure is analyzed especially with respect to the water-cement ratio and the amount of air. The AE and non-AE concrete specimens made of ordinary portland cement are used in the test. In the second stage, the non-AE concrete specimens using vibratory compaction to improve the durability to frost action, and the high watertight specimens of rapid hardening portland cement to increase their initial strength are produced and tested. The degree of watertightness of the specimens is determined by measuring the permeability of the specimens and the bubble structure of the high watertight concrete is also estimated.

  • PDF

Effect of Rootzone Mixes Amended with Crumb Rubber on the Physical Properties (폐 타이어 고무칩을 혼합한 개량제의 물리성 개선 효과)

  • Chong, She-Kong;Ok, Chang-Ho
    • Asian Journal of Turfgrass Science
    • /
    • v.20 no.1
    • /
    • pp.83-91
    • /
    • 2006
  • This research was initiated to enhance the tilth of fine-textured soil for turf growth by incorporation of crumb rubber shredded from used tires. A specific objective was to determine the physical properties of soil mixes amended with different grade and amount of crumb rubber in soils. Two soils and three different grades(3.5, 6.5 and 9.5 mm) of crumb rubber were used. The soils selected were an Arenzville silt loam(coarse-silty, mixed, nonacid, mesic Typic Udifluvents) and a Hosmer silty clay loam(fine-silty, mixed, mesic Typic Fragiudalfs). The amount of crumb rubber mixed in soil ranged from 0 to 0.4 $g{\cdot}g^{-1}$(using 0.05 $g{\cdot}g^{-1}$) increments and 0 as a control. For each treatment, soil cores were constructed following the recommendation by the United States Golf Association Green Section Record. Results indicated that porosity of the mixes decreased as the amount of crumb rubber increased. Regardless of the grade of crumb rubber, mixes with less than 0.15 $g{\cdot}g^{-1}$ of crumb rubber in fine-textured soil could not enhance their macro-porosity and hydraulic conductivity. However, as the amendment increased over 0.15 $g{\cdot}g^{-1}$, the tilth of the mixes had improved significantly macro-porosity, hydraulic conductivity and air permeability, as compared with a control.

Fundamental Study on High Strength and High Durability Cement Concrete Pavement: Part II Strength and Durability Evaluations (시멘트콘크리트 포장의 고강도 고내구성을 위한 기초 연구 : Part II 최적배합콘크리트의 강도 및 내구특성 분석)

  • Yun, Kyong-Ku;Park, Cheol-Woo;Hong, Seung-Ho
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.51-60
    • /
    • 2009
  • This study investigates the fresh state characteristics, strength, chloride ion penetration resistance and freeze-thaw resistance of the suggested high strength-high durability cement concrete pavement. The required workability and air content could be achieved by using an appropriate admixtures. However its dosage should be carefully determined through field trial batches. Compressive strength increased with the increased cement content and, in particular, high cement volume concrete continuously developed strength up to 90 days. No clear relationship, however, existed between flexural strength and cement content. Chloride penetration resistance seemed as a function of curing age rather than the cement content. Freeze-thaw resistance test was conducted using two different coolants, tap water and 4% NaCl solution. When the tap water was used no severe damage was observed up to 300 cycles regardless the air content. Under 4% NaCl solution, specimens of 326kg/$m^3$ cement content showed severe damage with surface scaling. Based on the experimental investigations herein, it is highly recommended that the cement content be greater than 400kg/$m^3$ for strength-high durability cement concrete pavement structures.

  • PDF

Change of Hydraulic Characteristics due to Well Drilling and Well Development in an Unconsolidated Aquifer (미고결대수층에서 우물 굴착 및 개량에 의한 대수층의 수리특성 변화)

  • Kim, Byung-Woo;Kim, Gyoo-Bum;Kim, Geon-Young
    • The Journal of Engineering Geology
    • /
    • v.22 no.1
    • /
    • pp.27-37
    • /
    • 2012
  • To investigate the effect of aquifer disturbance on hydraulic properties while well drilling at unconsolidated aquifer, the following tests were conducted: the surge block and air-surging methods, which are well development methods used after well drilling; and step-drawdown tests and constant-rate pumping tests, which are used to assess changes in the aquifer after well drilling and development. The result of step-drawdown tests indicated that drawdown for a pumping-rate of $700m^3/day$ was 21.62 m after well development, decreasing 4.39 m from 26.01 m after well drilling. The skin factor used to identify the well properties decreased from 7.92 after well drilling to 5.04 after well development, respectively, which shows the improvement of well. Constant-rate pumping tests revealed a small increase in aquifer transmissivity after well development at MW-2, -3, and -4, centering around pumping well, from $1.684{\times}10^{-3}{\sim}4.490{\times}10^{-3}m^2/sec$ to $4.002{\times}10^{-3}{\sim}4.939{\times}10^{-3}m^2/sec$. MW-1, however, showed decline in hydraulic conductivity from $1.018{\times}10^{-2}m^2/sec$ to $6.988{\times}10^{-3}m^2/sec$, which was caused by a small decrease of aquifer permeability around monitoring well MW-1 due to latent factor of air interception and clogging in aquifer during surging. This finding indicates that fine particles have an effect on hydraulic properties at unconsolidated aquifers during well drilling; therefore, we consider that well drilling and development have an effect on hydraulic properties.

Geotechnical Characteristics of Prefabricated Vertical Drain System for Contaminated Soil Remediation (오염토양 복원을 위한 연직배수시스템의 지반공학적 특성)

  • Shin, Eunchul;Park, Jeongjun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.5
    • /
    • pp.5-14
    • /
    • 2007
  • The quantity of noxious wastes generated by the growth in industrialization and population in all over the world and its potential hazards in subsurface environments are becoming increasingly significant. The extraction of the contaminant from the soil and movement of the water are restricted due to the low permeability and adsorption characteristics of the reclaimed soils. Incorporated technique with PVDs have been used for dewatering from fine-grained soils for the purpose of ground improvement by means of soil flushing and soil vapor extraction systems. This paper is to evaluate several key parameters that affected to the performance of the PVDs specifically with regard to: well resistance of PVD, zone of influence, and smear effects. In the feasibility of contaminant remediation was evaluated in pilot-scale laboratory experiments. Well resistance is affected on the vertical discharge capacity of the PVDs under the various vacuum pressures. The discharge capacity increases consistently in areal extents with higher applied vacuum up to a limiting vacuum pressure. The head values for each piezometer at different vacuum pressures show that the largest head loss occurs within 14 cm of the PVD. Air flow rates and head losses were measured for the PVD placed in the model test box and the gas permeability of the silty soils was calculated. Increasing the equivalent diameter results in a decrease in the calculated gas permeability. It is concluded that the gas permeability determined over the 1,500 to 2,000 $cm^3/s$ flow rates are the most accurate values which yields gas permeability of about 3.152 Darcy.

  • PDF

Effect of Hysteresis on Soil-Water Characteristic Curve in Weathered Granite and Gneiss Soil Slopes during Rainfall Infiltration (풍화계열 사면의 불포화 함수특성곡선 이력이 강우 침투에 미치는 영향)

  • Shin, Gil-Ho;Park, Seong-Wan
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.7
    • /
    • pp.55-64
    • /
    • 2006
  • Shallow failures of slopes in weathered soils are caused by infiltration caused by prolonged rainfall. These failures are mainly triggered by the deepening of the wetting band accompanied by a decrease in suction induced by the water infiltration. In this paper, hysteresis on soil-water characteristic curve (SWCC) of granite and gneiss weathered soils is investigated using transient flow analysis respectively. Each case was subjected to artificial rainfall intensities and time duration depending on the laboratory-based drying and wetting processes. The results show that the unsaturated seepage on weathered slopes are very much affected by the initial suction of soils and unsaturated permeability of the soils. In addition, a granite weathered soil has a lower air-entry value, residual matric suction, and wetting front suction and less hysteresis loop than a gneiss weathered soil.

Soil-Water Characteristic Curve of Sandy Soils Containing Biopolymer Solution (바이오폴리머를 포함한 모래지반의 흙-습윤 특성곡선 연구)

  • Jung, Jongwon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.10
    • /
    • pp.21-26
    • /
    • 2018
  • Soil-water characteristic curve, which is called soil retention curve, is required to explore water flows in unsaturated soils, relative permeability of water in multi-phase fluids flow, and change to stiffness and volume of soils. Thus, the understanding of soil-water characteristic curves of soils help us explore the behavior of soils inclduing fluids. Biopolymers are environmental-friendly materials, which can be completely degraded by microbes and have been believed not to affect the nature. Thus, various biopolymers such as deacetylated power, polyethylene oxide, xanthan gum, alginic acid sodium salt, and polyacrylic acid have been studies for the application to soil remediation, soil improvement, and enhanced oil recovery. PAA (polyacrylic acid) is one of biopolymers, which have shown a great effect in enhanced oil recovery as well as soil remediation because of the improvement of water-flood performance by mobility control. The study on soil-water characteristic curves of sandy soils containing PAA (polyacrylic acid) has been conducted through experimentations and theoretical models. The results show that both capillary entry pressure and residual water saturation dramatically increase according to the increased concentration of PAA (polyacrylic acid). Also, soil-water characteristic curves by theoretical models are quite well consistent with the results by experimental studies. Thus, soil-water characteristic curves of sandy soils containing biopolymers such as PAA (polyacrylic acid) can be estimated using fitting parameters for the theoretical model.

A study on the optimal reinforcement area for excavation of a small cross-section shield TBM tunnel in fault fracture zone through parameter analysis (매개변수 분석을 통한 단층파쇄대의 소단면 쉴드 TBM 터널 굴착 시 최적 보강영역 연구)

  • Kang, Byung-Yun;Park, Hyung Keun;Cha, Jae-Hoon;Kim, Young-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.3
    • /
    • pp.261-275
    • /
    • 2020
  • When excavating a small cross-section tunnel in a fault fracture zone using the shield TBM method, there is a high possibility of excessive convergence and collapse. Appropriate ground reinforcement is required to minimize construction cost loss and trouble due to a fault fracture zone. In this study, the optimal reinforcement area was suggested and the surrounding ground behavior was investigated through numerical analysis using MIDAS GTS NX (Ver. 280). For the parameters, the width of the fault fracture zone, the existence of fault gouge, and the groundwater level and depth of cover were applied. As a result, when there is not fault gouge, the convergence and ground settlement are satisfied the standard when applying ground reinforcement by up to 0.5D. And, due to the high permeability coefficient, it is judged that it is necessary to apply 0.5D reinforcement. There is a fault gouge, it was possible to secure stability when applying ground reinforcement between the entire fault fracture zone from the top of the tunnel to 0.5D. And, because the groundwater discharge occurred within the standard value due to the fault gouge, reinforcement was unnecessary.