• Title/Summary/Keyword: 공기주입

Search Result 399, Processing Time 0.039 seconds

분류층 석탄가스화기 비반응 난류 유동장 수치해석

  • 이선경;정진도;김종진;지평삼;장동순
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.05a
    • /
    • pp.28-38
    • /
    • 1994
  • 분류층 가스화기 설계를 위한 일차연구로서 가스화기 이차공기 주입방법에 따른 비반응 난류장에 대한 수치해석을 검사체적에 기초한 유한차분방법을 이용하여 수행하였다. 압력과 속도의 연계문제는 SIMPLEC 알고리즘을, 레이놀즈 전단력은 k-$\varepsilon$ 난류모델을 사용하였다. 입자궤적 계산은 공기역학적 항력만을 고려하였으며 비선형적인 공기저항력에 의한 난류변동상관모델은 고려치 않았다. 이차공기 주입방법(parallel injection과 nonparallel 3$0^{\circ}C$ injection)에 따른 수치해석을 수행하여 Ar tracer의 질량분율에 대한 실험자료와 비교하여 만족할 만한 결과를 얻었으며 이차공기의 주입각 및 기타 제반변수에 따른 유동장 변화를 분석하였다.

  • PDF

A Study on Stabilization of Landfill by Air Ventilation in Field (공기주입방식을 통한 쓰레기 안정화의 현장적용에 관한 연구)

  • Lee, Hwan;Lee, Chae-young;Jeon, Yeon-ho;Kim, Kyung;Kim, Doo-il;Lee, Cheol-hyo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.4
    • /
    • pp.121-128
    • /
    • 2000
  • Landfill and lysimeter experiments were conducted to estimate the optimum air injection method for the degradation of waste in landfill and the pre-stabilization. Continuous injection with low pressure and quantity can be effective for pre-stabilization of old landfill due to the lower contents of volatile solids in landfill. Air injection and landfill gas (LFG)extraction showed that the SVE (Soil Vapor Extraction) effect by air ventilation was more significant than the biodegradation of organics. Theses results suggested that they could accelerate the biological stabilization of organic waste in landfills. It is also expected that they would reduce the problems including gas emission during the landfill mining, separation and/or transportation to such levels that might be discharged directly to the atmosphere or with minimal treatment, if required.

  • PDF

Fouling Mitigation for Pressurized Membrane of Side-Stream MBR Process at Abnormal Operation Condition (가압식 분리막을 이용한 Side-Stream MBR 공정의 비정상 운전조건에서 막 오염 저감)

  • Ko, Byeong-Gon;Na, Ji-Hun;Nam, Duck-Hyun;Kang, Ki-Hoon;Lee, Chae-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.6
    • /
    • pp.323-328
    • /
    • 2016
  • Pressurized membrane used for side-stream MBR process requires fouling control strategy both for normal and abnormal operation conditions for stable operation of the facilities. In this study, $85m^3/day$ of pilot-scale side-stream MBR process was constructed for the evaluation of fouling mitigation by air bubble injection into the membrane module. In addition, fouling phenomena at abnormal operation conditions of low influent and/or loading rate were also investigated. Injection of air bubble was found to be effective in delaying transmembrane pressure (TMP) increase mainly due to scouring effect on the membrane surface, resulting in expanded filtration cycle at a high flux of $40L/m^2{\cdot}h$ (LMH). At abnormal operation condition, injection of PACl (53 mg/L as Al) into the bioreactor showed 19% reduction of TMP increase. However, inhibition of nitrifying bacteria by continuous PACl injection was observed from batch experiments. In contrast, injection of powdered activated carbon (PAC, 0.6 g/L) was able to maintain the initial TMP of $0.2kg/cm^2$ for 5 days at the abnormal conditions. It may have been caused from the adsorption of extracellular polymeric substances (EPS), which was known to be excessively released during growth inhibition condition and act as the major foulants in MBR operations.

Effect of plasma treatment using underwater non-thermal dielectric barrier discharge to remove antibiotics added to fish farm effluent (양식장 배출수에 첨가된 항생제 제거 위한 수중 비열 유전체장벽 방전 플라즈마 처리 효과)

  • Kyu Seok Cho;Han Seung Kang
    • Korean Journal of Environmental Biology
    • /
    • v.40 no.4
    • /
    • pp.641-650
    • /
    • 2022
  • The purpose of this study was to compare the efficiency of air and oxygen injected into the underwater non-thermal dielectric barrier discharge plasma (DBD plasma) device used to remove five types of antibiotics (tetracycline, doxycycline, oxytetracycline, clindamycin, and erythromycin) artificially contained in the fish farm discharge water. The voltage given to generate DBD plasma was 27.8 kV, and the measurement intervals were 0, 0.5, 1, 2, 4, 8, 16 and 32 minutes. Tetracycline antibiotics significantly decreased in 4 minutes when air was injected and were reduced in 30 seconds when oxygen was injected. After the introduction of air and oxygen at 32 minutes, 78.1% and 95.8% of tetracycline were removed, 77.1% and 96.3% of doxycycline were removed, and 77.1% and 95.5% of oxytetracycline were removed, respectively. In air and oxygen, 59.6% and 83.0% of clindamycin and 53.3% and 74.3% of erythromycin were removed, respectively. The two antibiotics showed lower removal efficiency than tetracyclines. In conclusion, fish farm discharge water contains five different types of antibiotics that can be reduced using underwater DBD plasma, and oxygen gas injection outperformed air in terms of removal efficiency.

Enhanced Removal of Benzene-NAPL in Soil using Concurrent Injection of Cosolvent and Air (Cosolvent와 공기 동시 주입 공정에 의한 토양 내 벤젠-NAPL 세정 증대 연구)

  • Song, Chung-Hyun;Jeong, Seung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1095-1101
    • /
    • 2008
  • Nonaqueous phase liquids (NAPL) are the continuous source for soil and groundwater contamination. The first objective of the study was to verify the effect of co-injection of cosolvent and air on NAPL removal from soil-column system. The second objective of the study was to investigate the effect of alcohol-partitioning property on the NAPL removal by the co-injection process of cosolvent and air. Enhanced removal of benzene-NAPL by the co-injection process of ethanol and air was also verified within the soilcolumn system. However, the co-injection process of Tert-butanol (TBA) and air showed no enhancement of benzene-NAPL removal. This study found that the viscous pressure of TBA was so higher than the capillary pressure and TBA easily displaced the benzene-NAPL and air present in soil pores. Air of the coinjection process did not work for NAPL removal but hindered NAPL mobilization. NAPL partitioning property and viscous pressure of cosovlent should be considered for application of the co-injection process of cosolvent and air.

Effect of Agitation Speed and Air Rate on Separation Efficiency in Fly Ash Flotation (플라이애시 부유선별 과정에서 교반속도와 공기주입량 변화에 따른 영향 연구)

  • Kim, Min Sik;Kang, Heon Chan
    • Resources Recycling
    • /
    • v.27 no.1
    • /
    • pp.45-54
    • /
    • 2018
  • This study aimed to investigate the effects of mechanical factors such as agitation speed and air rate in fly ash flotation. Specifically, we used thermal power plant fly ash with unburned carbon content of 3.4 to 3.7%. The effect of pH, agitation speed, collector dosage, and frother dosage - the key factors of froth flotation - showed unburned carbon recovery and unburned carbon content of 63% and 34%, respectively, when the dosage of safflower oil used as collector was 800 g/ton, pH was 7, agitation speed was 1,200 rpm, and frother dosage was 400 g/ton. The SEM/EDS analysis of fly ash in that case indicated that the spherical fly ash particles lowered the unburned carbon content as they floated with the air bubbles without being dissolved in the unburned carbon or settled in the ore solution. The other experiment of changing the mechanical factors such as agitation speed and air rate resulted in unburned carbon recovery and unburned carbon content of 74% and 67%, respectively, at air rate of 8 L/min and agitation speed of 900 rpm. The recovery and unburned carbon content increased as the low agitation speed and additional air injection decreased the strength of the eddy current in the ore solution and consequently prevented the floating of fine fly ash particles with unburned carbon. In addition, the recovery rate and unburned carbon increased further to 80% and 70%, respectively, showing the best performance when the agitation speed and air rate were lowered to 800 rpm and 6 L/min, respectively.

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.

Biosparging 공법을 이용한 석유계탄화수소화합물 오염토양에 대한 현장적용성 평가

  • 신정엽;오경철;공준;이승우;전기식
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.35-38
    • /
    • 2004
  • 부틸알데히드로 오염된 대상 부지에 Biosparging 공법의 현장 적용을 위해 적정 공기 주입 압력 조건을 도출한 결과, 주 오염층인 자갈질 모래층에 공기주입 가능 파괴압력(Pe)는 약 300mmAq로 측정되었으며 4,500mmAq 압력 조건에서는 용존 산소농도의 영향 반경이 약 3 m로 나타났다. 위의 조건을 적용하여 약 150일간 운전한 결과, 영양물질을 투입하지 않은 초기 90일 동안 최고농도 대비 약 90%가 저감되었으며 그 이후에 영양물질을 투입하여 초기 최고 농도 대비 96%가 저감되어 복원목표치인 50ppm을 모든 지역에서 만족시켰다. 또한 생분해 반응속도가 k=0.03/day로 나타나 휘발성이 낮고 생분 해도가 뛰어난 부틸알데히드로 오염된 자갈질 모래층에 Biosparging공법이 성공적으로 적용된 사례이다.

  • PDF

Flow Analysis and Design of a Microchannel in a Lab-on-a-chip actuated with an Air Bladder (공기주입기로 구동되는 랩온어칩 내의 유동 해석과 미세 유로 설계)

  • Kang, Tae-Ho;Park, Sin-Wook;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1546-1547
    • /
    • 2007
  • 휴대용 면역진단 시스템을 구현하기 위하여 설계된 공기주입기로 구동되는 랩온어칩 내의 유체 유동을 컴퓨터 시뮬레이션을 통하여 해석하고, 문제점을 보완할 수 있는 구조로 랩온어칩을 재설계하였다. 공기주입기에서 흘러나오는 공기를 이용해 완충액 저장고 내에 있는 완충액을 토출시킬 때 다량의 기포가 발생함을 시뮬레이션 결과를 통해 알 수 있었다. 완충액 저장고의 내부에 계단형 구조를 삽입함으로서 완충액 이송 시 형성되는 기포를 상당히 억제할 수 있었다. 또한 계단형 구조는 유선을 역행 방지판 쪽으로 분산시켜 역행 방지판의 효율을 높일 것이다.

  • PDF

The Clinical Utility of Rectal Gas Distension F-18 FDG PET/CT (공기주입 직장 확장 F-18 FDG PET/CT의 임상적 유용성)

  • Kim, Jin-Suk;Lim, Seok-Tae;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.565-571
    • /
    • 2009
  • Purpose: The aim of this study was to evaluate the clinical value of rectal gas distension F-18 FDG PET/CT imaging for the differentiation of the rectal focal uptake lesions. Materials and Methods: Twenty four patients (M:F=11:13, Age $62.8{\pm}12.4$ years) underwent rectal gas distension F-18 FDG PET/CT, prospectively: initial image at 50-60 min after the intravenous injection of F-18 FDG and rectal distension image after the infusion of air through the anus. Focally increased uptake lesions on initial images but disappeared on rectal distension images defined a physiological uptake. For the differential evaluation of persistent focal uptake lesions on rectal distension images, colonoscopy and histopathologic examination were performed. Results: Among the 24 patients, 27 lesions of focal rectal uptake were detected on initial images of F-18 FDG PET/CT. Of these, 7 lesions were able to judge with physiological uptake because the focal increased uptake disappeared from rectal distension image. Remaining 3 lesions were non-rectal lesions (2 lesions: rectovesical space, 1 lesion: uterine myoma). Among 17 lesions which was showed persistent increased uptake in rectal distension image, 15 lesions were confirmed as the malignant tumor (SUVmax=$15.9{\pm}6.8$) and 2 lesions were confirmed as the benign lesions including adenoma and inflammatory disease. Conclusion: The rectal distension F-18 FDG PET/CT imaging could be an important noninvasive method for the differentiation of malignant and benign focal rectal uptake lesions including physiologic uptake.