• 제목/요약/키워드: 공기조화기

검색결과 100건 처리시간 0.043초

자동차용 공기조화기의 퍼지 제어에 관한 연구 (A study on fuzzy control for vehicle air conditioner)

  • 김양영;봉재경;진상호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.516-519
    • /
    • 1997
  • In this paper, the control of the temperature for the vehicle air conditioner is implemented with the fuzzy controller using a micro controller. The linguistic control rules of the fuzzy controller are separated into two out variables(multi input multi output ; MIMO) : one is those for the blower motor, and the other is those for air mix door. The error in fuzzy controller, the input variable is defined as difference between the reference temperature and the actual temperature in the cabin room. The fuzzy control rules are established from the human operator experience, and based engineering knowledge about the process. The method of the center of gravity is utilized for the defuzzification.

  • PDF

혼합 공조 시스템의 EER(A) 평가 (Evaluation of energy efficiency ratio in the mixed air conditioner system)

  • 김병순;이승홍
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.542-548
    • /
    • 1999
  • Instead of testing split air conditioners, an empirically based calculation procedure may be used to estimate the Energy Efficiency Ratio at ARI A test conditions. Typically, the system involving the indoor unit well sold and the given outdoor unit is called the matched system. All other systems involving a given outdoor unit and other indoor units are called the mixed systems. To estimate the EER(A) for the mixed systems, EER(A) for the matched system must be known, Generally, the EER(A) for the matched system is known. This procedure relies on independent measurements and calculations made on an outdoor unit in conjunction with a matched indoor and a mixed indoor coil. A heat pump simulation model was used to quantify the effects of individual system components on the system performance. The procedure is applicable to all air-conditioning units having rated cooling capacities less than 19,000W and charged with refrigerant 22.

  • PDF

공기조화기의 설계인자가 계절성능에 미치는 영향 (EFFECT OF DESIGN PARAMITERS ON SEASONAL PERFORMANCE OF AN A/C SYSTEM)

  • 박윤철
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.239-241
    • /
    • 2010
  • Performance evaluation for an air conditioning system is conducted at a specified test conditions. One is low temperature and the other is high temperature condition. Most of the manufactures tried to improve the performance at higher outdoor temperature. One of the reasons is that the customer wants to get ore capacity at high temperature climate. To cope with these kinds of demand, manufactures are tried to achieve higher capacity at high temperature with minimum power consumption even with same size of the system. Consequently, previous studies on performance of the air conditioning system are focused on capacity and performance improvement at high outdoor temperature.

  • PDF

지하역사 공기조화기 장착용 판넬형 부직포필터 성능 연구 (A study on panel structure filter performance of air handling units for subway stations)

  • 황선호;배성준;신창헌;박윤호;권순박;김세영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1328-1334
    • /
    • 2010
  • As the life quality is higher and higher, the requirement for the clean air in a subway station is strongly being increased. Therefore, many researches have been performed about that. Seoulmetro has taken many parts and has applied latest products for the higher level of air quality. However, by various kinds of facilities, it is hard to maintain the facilities and verify their performances. Therefore it is better to use qualified air filter system by the performance test at subway stations than to apply newly developed one without any verification. This study is focused on the performance verification for a panel structure, which consists of non-woven fabric, to suggest the standard of air filter systems.

  • PDF

냉매충전량이 모세관 팽창장치를 가진 공기조화기의 성능에 미치는 영향 (The Effects of the Refrigerant Charge on the Performance of an Air Conditioner with Capillary Tube Expansions)

  • 최은수;김종배
    • 설비공학논문집
    • /
    • 제14권5호
    • /
    • pp.359-364
    • /
    • 2002
  • A popular type of residential air conditioner is the split system which has two separate units: indoor and outdoor units During field installation of the split system, the potential exists for not setting the charge exactly to the manufacturer´s specifications. The objective of this study is to investigate the effects of the refrigerant charge on the performance of the air conditioner. An air conditioner with capillary tube expansions was tested for various refrigerant charges. The results indicated that the more charge resulted in the more flowrate of the refrigerant. The flowrate of the refrigerant was one of the most important factors to understand the e(sects of the charge on the performance of the air conditioner with capillary tube expansions. Under-charge results in wide region of superheated vapor of the refrigerant in the evaporator, while over-charge results in high temperature of the liquid refrigerant in the evaporator.

에어백 기술의 발전동향 (Trends of airbag technology)

  • 김권희
    • 오토저널
    • /
    • 제18권5호
    • /
    • pp.1-9
    • /
    • 1996
  • 에어백 관련기술은 차체 충돌특성 평가, 승객거동분석, 좌석벨트/조향축/에어백의 조화설계 등을 포함하는 시스템 엔지니어링 기술과 충돌감지센서, 가스발생기, 모듈 등을 포함하는 주요 기능 부품의 설계 및 제조기술로 구분된다. 이 중 시스템 엔지니어링 기술은 국내의 완성차 업계의 노력에 의하여 선진국의 수준에 근접하고 있으나 부품의 설계 및 제조기술은 매우 취약한 상황이다. 80년대 후반부터 각국의 에어백 관련 특허 출원 건수가 급증하고 있으며 새로운 기능의 부품들이 속속 개발되고 있다. 에어백 기술의 발전방향은 소형화, 경량화, 저렴화로 요약된다. 차량의 전방 충돌에 대비한 에어백이 주종을 이루고 있으나 측면 충돌에 대비한 side bag, 뒷자석 승객을 보호하기 위한 rear bag 등이 개발되고 있고 최근에는 버스 등 대형차량이나 모터사이클 등에도 에어백을 부착하기 위한 연구가 추진되고 있다. 에어백은 충돌센서(crash sensor), 가스발생장치(inflator), 공기주머니(bag), 덮개(cover), 배선(wire harness) 등으로 구성된다. 이들 중에서 공기주머니, 덮개, 가스발생장치를 결합한 부분 조립품을 모듈(module)이라고 부르고 있다. 이하에서는 에어백을 구성하는 주요 기능부품들의 종류, 특성과 기술개발 동향을 알아보기로 한다.

  • PDF

주파수변조장치를 이용한 열펌프식 공기조화기의 냉방-난방에 관한 실험적 연구 (An Experimental Study on the Performance of Heat Pump Air Conditioner according to Frequency Modulator for Cooling and Heating)

  • 이대우;조진호
    • 설비공학논문집
    • /
    • 제1권3호
    • /
    • pp.203-209
    • /
    • 1989
  • This paper is an experimental study on the pleasantly suitable cool/warm air conditioning system in order to minimize the energy consumption by attaching the electronic-controlled device to the heat pump air conditioning system.While the cool/warm air conditioning, the air temperatures in the entrance and exit of the indoor heat exchangers should be checked and when the surface of heat exchanger is reached to the dew point temperature, a speed of the compressor is to be automatically controlled by anti-dewing system in order to minimize the energy consumption.At the result of this study, the energy consuming amount is saved about 5% more than that of the conventional air conditioning system by prevent unnecessary dew forming.

  • PDF

A Frost-less Heat Pump

  • 황윤제;이원희
    • 대한설비공학회지:설비저널
    • /
    • 제31권3호
    • /
    • pp.53-58
    • /
    • 2002
  • 대부분의 가정용 냉난방겸용 공기조화기(히트펌프)는 실외온도가 $5^{\circ}C$ 이하이고, 습도가 높은 저온고습조건에서 난방운전을 하면 열교환기 표변에 서리가 발생하고, 이로 인해 시스템의 성능이 떨어지게 된다. 이를 방지하기 위하여 어느 일정 조건이나 시간이 되면 히트펌프는 제상운전을 하게 되는데, 보통의 가정용 히트펌프의 경우 난방운전도중에 사이클을 냉방운전으로 전환하여 실외 열교환기의 온도를 높여 줌으로써 제상을 하는 방식 (Cycle reversing method)을 사용하고 있다. 이 방식은 부가적인 제상회로플 구성하 거나 히터를 첨가하는 등의 재료비 증가 없이 제상을 수행한다는 장점이 있으나, 시스템의 에너지 효율 측면에서 불리할 뿐만 아니라, 소비자의 입장에서 보면 제상운전이 진행되는동안에 따뜻한 바람이 공급되지 않아 쾌적한 공조를 제공받지 못한다는 단점이 있다. 본 자료에서는 먼저 제상방석에 관하여 그 종류와 특정을 알아보고, 최근에 진행되고 있는 착상 지연기술 중 어큐물레이터 내에 히터를 설치하는 방식(Viung C. Mei, et al., 2002, ASHRAE TRANSSACTIONS, V 108, Pt. 1)에 대하여 소개하고자 한다.

  • PDF

합성곱 AutoEncoder를 이용한 공기조화기 이상 감지와 실시간 모니터링 (Air conditioner anomaly detection and real-time monitoring using Convolution AutoEncoder)

  • 이세훈;김민지;임유진;조비건
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2021년도 제64차 하계학술대회논문집 29권2호
    • /
    • pp.5-6
    • /
    • 2021
  • 본 논문에서는 Semi-supervised Learning 방식의 이상감지 방법을 제안한다. 취득한 소음 데이터를 이미지화 시킨 후 Convolution AutoEncoder 학습 방법을 이용하여 모델을 학습한다. 고장 데이터와 정상 데이터 간의 데이터 불균형 문제가 대두되기 때문에 정상 데이터만을 활용한 이상감지는 실제 산업현장의 상황에 알맞게 사용할 수 있을 것이라 기대한다.

  • PDF

LonWorks/Ethernet 서버를 이용한 HVAC의 Web 기반제어에 관한 연구 (Web-Hased Control and Monitoring System Using LonWorks/Ethernet Sever for HVAC Application)

  • 홍원표;안흥수;최호성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.225-231
    • /
    • 2005
  • 본 연구에서는 프랜트 및 빌딩자동제어 분야에서 적용이 확대되고 있는 LonWorks 필드버스를 이용하여 기존의 공기조화 시스템를 제어하고 있는 DDC제어기를 대체할 수 있도록 필드버스에서 사용이 가능한 고성능 저가의 지능형 제어모듈을 개발하였다. 이는 필드버스 기반의 AHU 전용 지능형제어기를 새로운 설계기술로 개발하고 상품화를 실현하였다. 특히 S/W부분에서도 8 bit Neuron chip에 매우 콤팩트하게 내재된 고성능 응용프로그램도 개발하였다. 또한 Echelon 사의 iLON 100 server의 Soap/XML을 사용하여 Web 브라우저에서 쉽게 프로그램을 작성 제어모니터링 기법을 개발하였다. 공조기의 실험시스템을 구축하여 개발된 전용 제어기 및 Web 기반제어를 실험한 결과 밸브, 댐퍼제어 및 감시기능이 기존 DDC 제어기보다 우수함을 확인하였으며 원격제어 기반을 구축하였다.

  • PDF