• Title/Summary/Keyword: 공기유동해석

Search Result 547, Processing Time 0.025 seconds

Air Fluid Analysis between Porous PE-Plate and Glass in Air-Floating FPD Conveyor System (공기부상 FPD 이송장치에서 다공질판과 글래스 사이의 공기유동 해석)

  • Lho, Tae-Jung;Shon, Tae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.878-885
    • /
    • 2008
  • The FPDs(Flat Panel Displays) such as LCD(Liquid Crystal Display) and PDP(Plasma Display Panel) and OLED(Organic Light Emitting Diode), recently, have been substituted for CRT(Cathode Ray Tube) displays because they have a convex surface, small volume, light weight and lower electric power consumption. The productivity of FPDs is greatly dependent on the area of thin glass panel with 0.6 - 0.8mm thickness because FPDs are manufactured by cutting a large-scaled thin glass panel with patterns to the required product dimensions. So FPD's industries are trying to increase the area of thin glass panel. For example, the thin glass panel size of the 8th generation is 2,200mm in width, 2,600mm in length and 0.7mm in thickness. The air flows both in the thin glass panel and in the porous PE-plate surface were modeled and analyzed, from which a working condition was estimated. The thin glass panel on the porous PE-plate surface with self-lubricating characteristics was investigated and compared with that on the square duct floating bar surface with many holes of 1mm diameter when the thin glass panel contacts the floating bar surface due to malfunction of electric power supply.

Computational Fluid Analysis for Optimization of Vortex Cup with Different Shape (형상 변화에 따른 볼텍스 컵 최적화를 위한 전산유동해석)

  • Kim, Joong Hui;Sohn, Chang Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.8
    • /
    • pp.671-676
    • /
    • 2014
  • The vortex cup is proposed as a method to transport sensitive products such as silicon wafers in manufacturing. Air through the inlet nozzle located at the top of the vortex cup flows to form a swirl in the cylinder. The flow located in the lower part of the thin gap between the vortex cup and the bottom surface escapes and generates a negative pressure that can lift objects. In this research, three-dimensional numerical simulation of the air flow field in a vortex cup is performed, and a comparison of the simulation and experimental results shows very good agreement. In addition, the vortex cup length and shape that affect the negative pressure were applied to the analysis. Through the simulation results, optimum conditions for the vortex cup shape were proposed.

壓縮點火機關의 燃燒室 特性과 狀態變化(I)

  • 김광수
    • Journal of the KSME
    • /
    • v.23 no.6
    • /
    • pp.427-433
    • /
    • 1983
  • 내연기관의 성능은 실린더에서 연료의 화학에너지가 열에너지로 얼마만큼 빠르고 완전하게 변화하느냐에 좌우된다. 이를 위해서는 실린더 내에서 뜨거운 압축공기와 연료의 혼합 및 증기화가 요구된다. 엔진의 출력은 매 사이클당 흡입.압축할 수 있는 공기량에 좌우되므로 연소의 해석을 위해서는 실린더 내의 공기유동, 연료의 분무 및 연소과정을 이해 해야한다. 배기와 엔진효율의 요구성때문에 희박 혼합기 또는 EGR (exhaust gas recirculation)이 필요하게 된다. 그러나 희석이 크면 낮은 연소온도, 낮은 층류흐름속도와 화염전면의 낮은 난류강도 때문에 연소기간이 증대하게 된다. 실제로 희박의 증가는 실화 또는 긴 연소 지연기간, 사이클 마다의 연소맥동현상, HC배기의 증가등을 초래하게 된다. 이러한 저온연소의 단점들은 연소상태를 안정시키고 연소량을 증대시키는 공기의 유동을 이용해서 해결 될 수 있다. 최근에는 선회류와 난류의 강도를 증가시켜서 빠른연소(fast burning)를 이루고 있다. 선회류와 난류의 강도를 증대시키는 가장 중요한 2가지 방법은 흡입포트(port), 매니홀드(manifold)설계이다.

  • PDF

The Study of Air Sampling Smoke Detector (공기흡입형 연기감지장치에 관한 연구)

  • 이복영;이병곤
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.86-91
    • /
    • 2003
  • Since the air stream in the room controlled by HVAC system affects on he expected response of conventional detectors which are designed in accordance with normal characteristics of air stream in the fire incident, unexpected operation time delay may occur in fire. In order to solve this problem and to improve sensitivity so that to initiate fire in its early stages for minimizing damage and protecting people, we studied and developed Air Sampling Smoke Detector. The Air Sampling Smoke Detector is a kind of active-type fire detection system. it draws air continuously from the protected area through an air sampling pipe network to the smoke density analyzer. This study presents smoke density analysing technique and air intake balancing technique through an air sampling pipe network. As a result of evaluating, Air Sampling Smoke Detector was much more sensitive than conventional smoke detectors that passively wait for smoke to reach them and was not affected by ambient airflow in the room by means of balanced air intake through the sampling holes.

Conjugated Heat Transfer Analysis of Electric Heater (전기식 히터 복합 열유동 해석)

  • Shim, Chang-Yeul;Park, Soon-Sang;Han, Poong-Gyoo;Kim, Young-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.973-976
    • /
    • 2011
  • In this paper, the conjugated heat transfer anslysis was performed about an electric heater used in a combustion test equipment of a combustor engine to figure out a physical phenomenon that heater coil was periodically cut during heating test. The result of analysis is that the temperature of coil at coil inlet region was increased locally because the velocity of air was slow in that region. The coil of heater was moved to 25mm downstream so that the structure stability of coil was assured by the decrease of the coil temperature due to increase of an air velocity.

  • PDF

A Computational Investigation on Airflow Structures Inside a Ball Bearing at High-Speed Rotation (고속 회전하는 볼베어링 내 공기 유동구조 수치해석 연구)

  • Kim, Dong-Joo;Oh, Il-Suk;Hong, Seong-Wook;Kim, Kyoung-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.6
    • /
    • pp.745-750
    • /
    • 2011
  • In a hope to better understand the flow and convective heat transfer characteristics inside a ball bearing, air flow between the rolling elements and raceways at high speed bearing rotation is numerically investigated using a simplified inner geometry of bearing and a CFD technique. Flow simulation results reveal the pressure distribution of airflow and the shear stress distribution on the ball surface, of which nonuniformity becomes significant with the increasing rotational speed. Also, the local point of maximum shear stress coincides with the stagnation flow area on the surface of rolling elements. A complex pattern of three-dimensional vortex structures is found in the air flow due to the relative motion of bearing elements and three different types of vortex pairs exist around the rotating and orbiting rolling elements.

An Experimental Study on Frosting of Humid Air-flow on a Surface with Local Cooling for Heat Exchanger Design (열교환기 설계를 위한 국소 냉각 표면위에서의 습공기 유동의 착상실험)

  • Kwon, Jeong-Tae;Lim, Hyo-Jae;Park, Kyoung-Woo;Kim, Chang-Eob;Kim, Kyung-Min;Kwon, Young-Chul
    • Journal of Energy Engineering
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • The present study has been conducted to understand the heat and mass transfer characteristics of humid airflow in frosting conditions. A flat plate of aluminum was used for the simulation of flat surface part of the fin of the heat exchanger. The aluminum surface temperatures were measured and analyzed to clarify the heat and mass transfer characteristics under frosting conditions. Also, the pressure drops were measured to clarify the air-blocking effect of frost in the mini channel of the air-side hoot exchangers. A data reduction method was developed far the analysis of local characteristics of humid air under frosting conditions.

Numerical Study of Flow Characteristics of Scramjet with a Cavity Flameholder (스크램제트 공동 화염 보염기 형상에 따른 유동 특성의 수치적 연구)

  • Jang, Won-Geun;Lee, Hak-Jin;Choe, Seong-Im
    • Proceeding of EDISON Challenge
    • /
    • 2014.03a
    • /
    • pp.603-609
    • /
    • 2014
  • 차세대 제트 추진기관으로 주목받고 있는 스크램제트 엔진의 핵심은 연소기 내부에서의 성공적인 초음속 연소를 필요로 한다. 초음속 연소는 공기-연료 혼합(fuel-air mixing)의 정도에 따라 연소효율이 영향을 받게 된다. 공동형 화염 보염기(cavity flameholder)는 재순환 영역(recirculation zone)을 생성하여 연료 혼합의 효율을 높여 지속적인 초음속 연소가 진행될 수 있는 시간을 제공한다. 본 연구에서는 EDISON 전산유체역학 소프트웨어를 이용하여 공동형 화염 보염기를 지나는 초음속 유동의 재순환 영역과 전압력 변화에 대한 전산 해석을 수행하였다. 초기 형상을 생성하여 유동 해석을 수행한 후, 3개의 형상 변수에 대한 매개 변수 연구를 통하여 공동의 형상과 위치에 따른 재순환영역의 제어가 가능함을 확인하였다.

  • PDF

Numerical Simulation on the Behavior of Air Bubble Discharging into a Water Pool through a Sparger without Load Reduction Ring (하중저감 링이 없는 증기분사기를 통해 수조로 방출되는 기포 거동에 대한 수치해석)

  • 김환열;배윤영;송진호;김희동
    • Journal of Energy Engineering
    • /
    • v.12 no.4
    • /
    • pp.259-266
    • /
    • 2003
  • Load reduction ring (LRR) was installed on the ABB-Atom sparger to reduce the oscillatory loadings due to the air bubble clouds in the water pool in case of safety relief system operations. In order to investigate the effect of LRR on the pressure field, a numerical simulation on the behavior of air bubble clouds discharging into a water pool through a ABB-Atom sparser without LRR was performed by using a commercial thermal hydraulic analysis code, FLUENT 4.5. Among the multi-phase models contained in the code, the VOF (Volume Of Fluid) model was used to simulate the interface of water, air and steam flows. By comparing the analysis results with the previous ones, the load reduction ring has an effect on reducing the oscillatory loads at the wall. It also includes the effect of air mass and inlet boundary conditions of the pipe on the pressure oscillations at the wall.

Numerical Analysis of Natural Convection in Room Fire (화재실내 자연대류의 수치해석)

  • Jung Gil-Soon;Lee Seung-Man;Lee Byung-Kon
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.18-25
    • /
    • 2005
  • In this study, numerical analysis of two-dimensional unsteady natural convection of air in a square enclosure heated from below, was performed as a basic research of fire science. SIMPLE algorithm was used to the pressure term of momentum equations in the numerical analysis. The numerical analysis were studied for the two model cases and two heat conditions, respectively, which are different with insulation of enclosures and position of heat applied. Also, the ceiling temperatures of enclosure were measured to compare the accuracy of numerical analysis, and it is found that the temperature predicted by numerical analysis were agreed well with the measurements. Streamline and isotherm of the each model case were acquired for each time step.