• Title/Summary/Keyword: 공기역학적 기능

Search Result 31, Processing Time 0.022 seconds

The Analysis of Wind Hole Effect for The Bangpae Kite (방패연의 방구멍 효과에 대한 분석)

  • Kang, Chi-Hang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.7
    • /
    • pp.561-566
    • /
    • 2014
  • Our Korean traditional cultural inheritance Bangpae Kite has the stable rectangular shield shape decorated with artistic paint or poem and a good flight performance due to the central wind hole. In this paper, to analyse the wind hole effect to kite performance we performed the wind tunnel testing of the various design factor of kite model and air flow visualization passing through the wind hole. As the result of aerodynamic analysis, we knew that the wind hole of kite displays similar function of slot system for the wing high lift device. This fact demonstrates that our ancestor understood the function of slot system and applied effectively to the development of kite flight performance.

A study on the biomechanical modeling of human pharynx by using FEM(Finite Element Method) (유한요소기법에 의한 인두의 생체역학모델에 관한 연구)

  • Kim, Seong-Min;Kim, Nam-Hyeon
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.423-429
    • /
    • 1998
  • Human pharynx is unique, acting as a complex interchange between the oral cavity and esophagus, and between the nasal cavity and lungs. It is actively involved in the transport of food and liquid, producing the forces that guide that bolus into the upper esophagus and away from the adjacent larynx and lungs. This study intended to develop a biomechanical model of the human pharynx, utilizing Finite Element Method(FEM). Within each model changes in cross sectional intralumenal area were calculated and compared with the area from the computer-generated FE model. Area matching allowed estimation of intraluminal pressure gradients during swallow. The estimated pharyngeal pressure gradient varies from one region to another. The estimated pharyngeal pressure gradients showed different patterns for upper four levels and lower four levels. The contraction velocity for upper four levels is much higher than lower four levels. The higher contraction velocities and pressure gradients in the upper levels are consistent with the bolus velocities required for efficient swallow.

  • PDF

Control of High-Pressure Exhaust Gas Flows Using Shock-Wave Confinement (충격파 감금법을 이용한 고압배기가스 유동의 제어)

  • ;;K.Matsuo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.19-19
    • /
    • 1998
  • 최근 화학, 연소, 동력, 제철 등의 각종 플랜트에서 조업압력이 고압화되어 가고 있으며, 이에 수반하여 배관계를 통하는 고압가스 유동에 관한 연구가 활발하게 진행되고 있다. 배관계를 통하는 고압가스의 유동에 있어서 유량의 적절한 제어, 유동에 의하여 야기되는 배관계의 소음·진동, 그리고 배기가스의 적절한 처리법 등은 공학적으로 매우 중요한 문제로 알려져 왔다. 일반적으로 정상운전을 하는 플랜트에서 고압 배기가스의 문제는 배기가스 Expander에 의하여 에너지를 회수하는 방법이 생각될 수 있으나, 실제 공업현장에서는 배기가스를 안전하고, 또 소음·진동을 발생시키지 않도록 적절하게 처리하는 것이 매우 중요한 기술적 과제로 남아 있다. 일반적으로 배기가스의 압력이 임계압력(critical pressure) 이상으로 되는 경우(실제 대부분의 플랜트에서 배기가스의 압력은 임계압력보다 매우 높다), 배관계 내부에서 충격파(shock-wave)가 발생하여 난류와동 혹은 난류경계층과 간섭하게 됨으로써 강력한 공기역학적 소음이나 진동을 발생시키게 된다. 이와 같은 소음·진동에 대한 대책으로는 현재 가스배출부에 감압밸브를 직렬로 설치하거나, 유로에 다공판(porous plates)들을 삽입하여 감압과정을 공간적으로 분산시킴으로써, 충격파가 발생하지 않도록 하는 방법을 주로 채택하고 있다. 그러나 이러한 방법을 적용하는 경우 배기가스 유동에 대한 유량의 제어기능이 저하되는 문제가 발생한다.

  • PDF

Heat-up Calculation for the Auxiliary Feed Water Pump Room at Ulchin Units 3 and 4 for Loss of HVAC Accidents (HVAC 상실사고시 울진원전 3/4 호기의 보조급수펌프 격실 온동상승 평가)

  • Yoon, Churl;Park, Jin-Hee;Hwang, Mee-Jeong;Han, Sang-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.553-562
    • /
    • 2012
  • Computational Fluid Dynamics (CFD) analysis has been performed to estimate the air temperature inside an Auxiliary Feed Water (AFW) Motor-Driven (MD) pump room for the case where there is loss of Heating, Ventilation, and Air-Conditioning (HVAC). A transient calculation for the closed pump room without cooling by any HVAC system shows that the volume-averaged air temperature reaches around $60^{\circ}C$ for a transient period of 8.0 h. From previous studies, the external air and surface boundary temperatures are assumed to increase slowly starting from an initial temperature of $35^{\circ}C$. For the cases where the door is opened at 2, 4, and 6 h after the initiation of HVAC failure, the average air temperature promptly drops by about $4^{\circ}C$ when the door is opened and then slowly increases. The current calculations based on the CFD technique predict the rate of increase of air temperature to be lower than that determined by previous conservative calculations on the basis of a lumped model.

Aerodynamic Features and Voice Therapy Interventions of Functional Voice Disorder after Thyroidectomy (갑상선 절제 술 후 기능적 음성장애의 공기역학적 특징과 음성치료 중재)

  • Lee, Chang-Yoon;An, Soo-Youn;Chang, Hyun;Jeong, Hee Seok;Son, Hee Young
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.26 no.1
    • /
    • pp.25-33
    • /
    • 2015
  • Background and Objectives:The objective of this study was to investigate the features of post-thyroidectomy subjective voice disorder by Voice Handicap Index (VHI) and Voice Symptom Scale (VOISS) through aerodynamic analysis and to investigate the appropriate voice therapy intervention. Materials and Methods:Twenty post-thyroidectomy patients who had no recurrent laryngeal nerve paralysis through laryngeal stroboscopy were enrolled for this study. Acoustic and aerodynamic evaluations were performed before operation, 2 weeks and 3 months after operation. Subjective voice evaluation was performed by VHI and VOISS. Aerodynamic evaluation was compared and analysed by maximum phonation time(MPT), phonation threshold pressure(PTP), mean air flow rate(MFR), etc. Subjective voice evaluation was surveyed through VHI and VOISS. To evaluate patients' symptoms related to functional voice disorder, scores on physical domain in VHI and VOISS were selected to be compared for each session. Results: The 10 out of 20 participants who complained of voice symptoms had no significant difference with pre-operation in acoustic evaluation, but all showed higher scores on 2 weeks and 3 months after operation compared to pre-operation, in VHI-physical domain and selected questionnaires in VOISS. They reduced MPT and increased PTP value simultaneously. Laryngeal massage and breathing training were simultaneously treated to them, 5 participants resulting in improvement in MPT and PTP compared to pre-treatment. Conclusion:Patients who complained voice change with no organic damage after thyroidectomy were all shown to have reduced MPT and increased PTP in some by aerodynamic evaluations. Reduced MPT may imply some problem in air flow beneath glottis. Increased PTP suggests much more effort in vocalization mechanism than pre-operation. Comparing aerodynamic evaluations in post-thyroidectomy may provide information on behavioral interventions. Additionally, study on laryngeal massage and breathing training simultaneously treated to patients with such voice disorder is needed to be conducted with larger number of participants.

  • PDF

The Aerodynamic Evaluation of Velopharyngeal Function after Uvulopalatopharyngoplasty (구개인두성형술 후 공기역학적 구개기능 평가)

  • Hong, Ki-Hwan;Lim, Hyun-Sil;Choi, Seung-Chul;Kim, Byum-Kyu;Lee, Sang-Heon;Kim, Hyun-Gi
    • Speech Sciences
    • /
    • v.9 no.2
    • /
    • pp.167-177
    • /
    • 2002
  • Uvulopalatopharyngoplasty (UPPP) is one of the popular surgical procedure for snoring and sleep apnea syndrome. The main principle of this procedure is to reduce abundant velopharyngeal soft tissues resulting in a shortened soft palate, which may cause some alterations in speech sound. The purpose of this study is to evaluate the change of velopharyngeal function after UPPP in the view of aerodynamics. Thirty three patients who received uvulopalatopharyngoplasty for correcting snoring and sleep apnea were included in this study. The airflow, airflow rate and air pressure during the production of oral and nasal consonants were measured before surgery and 4 week and 8 week after surgery. The oral air flows and pressures for oral and nasal consonants were not changed after surgery. However, oral air pressure for nasal consonants were increased significantly after surgery. The nasal air flows for oral consonants were not changed after surgery, but for nasal consonants were decreased at 8 weeks after surgery. The nasal flow rate for oral and nasal consonants were increased at 8 weeks after surgery. The uvulopalatopharyngoplasty may result in affecting the aerodynamic air streams during speech production.

  • PDF

A Biomechanical Modeling of Human Pharyngeal Muscular Dysfunction by Using FEM(Finite Element Method) (유한요소법을 이용한 인두의 기능이상에 대한 생체역학적 모델)

  • Kim Sung Jae;Bae Ha Suk;Choi Byeong Cheol;Kim Sung Min
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.6 s.81
    • /
    • pp.515-522
    • /
    • 2003
  • Pharynx is a system transporting foods by peristaltic motion(contraction and expansion movement! into the esophagus and functioning as airway passages. In this study, structural changes of pharyngeal dysfunction are analyzed by biomechanical model using CT and FEM(finite clement method). Loading condition was assumed that equal pressure was loaded sequentially to inside of pharyngeal tissue. In order to analyze the pharyngeal muscular dysfunction by biomechanical model. the pharyngeal dysfunctions was classified into 3 cases. Taking into account the clinical complication by neuromuscular symptoms such as pharyngeal dysfunction after stroke. we assumed that a change of material property is caused by muscular tissue stiffness. A deformation of cross sectional area of the pharynx is analyzed increasing the stiffness $25\%,\;50\%,\;75\%$ in each case on the basis of stress-strain relationship. Based on three-dimensional reconstruction of pharyngeal structure using limited factor - techniques and the optimization procedure by means of inverse dynamic approach. the biomechanical model of the human pharynx is implemented. The results may be used as clinical index illustrating the degree of pharyngeal muscular dysfunction. This study may be used as useful diagnostic model in discovering early deglutitory impediment caused by physiological or pathological pharyngeal dysfunction.

The Effect of Inferior Turbinectomy on Heat/Humidity Transfer Ability of the Nose (하비갑개수술이 비강의 열/습도 전달 특성에 미친 영향)

  • Chung, Kang-Soo;Chang, Ji-Won;Kim, Sung-Kyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.419-424
    • /
    • 2012
  • In addition to respiration, the nose performs three other major physiological functions-air-conditioning, filtering, and smelling. On the basis of our experience in experimental investigations of nasal airflows in normal and abnormal nasal cavity models, airflows in the normal model and three artificially deformed models, which simulate the results of surgical treatments (inferior turbinectomy), are investigated by PIV and CFD. The left cavities of all three models are normal, and the right cavities are modified as follows: (1) excision of the head of the inferior turbinate, (2) resection of the lower fifth of the inferior turbinate, and (3) resection of almost the entire inferior turbinate. The use of high-resolution CT data and careful surface rendering of three-dimensional computer models with the help of an ENT doctor provide more sophisticated nasal cavity models. Nasal airflows for both normal and deformed cases are also compared.

An Experimental Study on the Resistance of Nylon Fiber Reinforced Concrete to Chloride Ion Penetration (나일론섬유보강 콘크리트의 염소이온 침투 저항성에 대한 실험적 연구)

  • Jeon, Joong-Kyu;Moon, Jae-Heum;You, Jin-O
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.557-560
    • /
    • 2008
  • Fiber reinforcement has been being widely used in concrete to enhance the mechanical properties and to reduce the micro-cracking caused by plastic and drying shrinkage. While researches has been focused on the benefits of fiber reinforcement, the properties of fiber reinforced concrete are strongly dependent on the type, shape and the amount of fibers in concrete. In this study, the resistance of nylon fiber reinforced concrete against the chloride ion penetration was experimentally observed by NT Build 492. The test results showed that the addition of nylon fiber has little effect on the change of the resistivity of concrete to the chloride ion penetration.

  • PDF

Change of Voice Handicap Index After Laryngeal Microsurgery for Benign Vocal Fold Lesions (양성 후두 질환 환자의 후두미세 수술 전후 음성 장애 지수의 변화)

  • Kim, Ji Hee;Choi, Hyo Geun;Park, Bumjung
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.26 no.1
    • /
    • pp.34-39
    • /
    • 2015
  • Background and Objectives:The Voice Handicap Index (VHI) evaluates the patients perception of impact of voice disorder in term of functional, physical, emotional factors. The purpose of this study was to evaluate the change of patient's subjective voice handicap index before and after laryngeal microsurgery for benign vocal cord lesions. Materials and Methods:We analyzed 55 patients who received laryngeal microsurgery for benign vocal cord disease from January 2011 to February 2013 retrospectively. There were 50 vocal nodules, 3 vocal polyps, 2 vocal cysts. VHI were analyzed before surgery and 3 months after surgery. Results:The VHI scores showed statistically significant reductions postoperatively in functional and emotional VHI (p=0.01 and p=0.034). Also, Emotional VHI score after microsurgery was higher in female than male [adjusted odd ratio (AOR)=0.292 ; 95% confidence interval, CI=0.098-0.869, p=0.01]. Conclusion:In other words, males experience significant more emotional effects that are improved after microscopic surgery.

  • PDF