• Title/Summary/Keyword: 공기스프링

Search Result 90, Processing Time 0.027 seconds

An Experimental Study on Performances of Leaf Spring Pad Air Bearing (판 스프링 패드 공기베어링 성능에 관한 실험적 연구)

  • 이희락;제양규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.94-99
    • /
    • 2003
  • As the rotating speed of rotors is increased, the instability and power loss become serious problems. Gas bearings are introduced as a good solution to those problems. But in the development of gas bearings, high load capacity and high damping force to vibrations are required. In this study a new air bearing using leaf spring pad is introduced to improve load capacity and damping force. The experimental results of the leaf spring pad air bearings show high load capacity and high damping forces. And the results show that leaf spring pad air bearings can be simultaneously acted as radial and thrust bearings

  • PDF

Review on Shock Absorber for Spacecraft Lander (착륙선용 충격 완충장치에 대한 고찰)

  • Lee, Chun-U
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.193.2-193.2
    • /
    • 2012
  • 달착륙선 등과 같은 특수 목적을 위해 제작된 우주용 착륙선에는 착륙 시 전달되는 충격하중이 탑재장비로 전달되지 못하도록 연착륙(soft-landing)을 위한 충격흡수 메커니즘이 구현되어 있어야 한다. 일반적으로 자동차 및 항공기에서는 실린더와 피스톤으로 구성된 유공압식 완충장치를 주로 사용하여, 피스톤 압축으로 실린더 내부 오일 또는 압축공기가 오리피스를 통하여 분출됨에 따라 유체마찰 에너지를 활용한 충격 흡수장치가 일반적이다. 그러나 이와 같은 지상 장비용 유공압식 충격흡수 메커니즘은 진공 및 무중력 우주 환경하에서 오리피스 기능 상실, 유압유 기화 현상 및 극저온/고온 환경에서의 성능저하 등의 문제점으로 인하여 우주용 착륙선 충격완충장치로 적용이 불가능하다. 따라서 기존의 우주용 착륙선의 대부분은 충격에너지를 기계적인 좌굴 소성 변형에너지로 변환하여 충격을 흡수할 수 있도록 알루미늄 허니콤을 주로 많이 사용하여 왔다. 본 연구에서는 진공 및 무중력 우주환경에서 착륙선 충격완충 장치로 적용이 가능하도록 실리콘 포옴과 스프링을 조합하여 구성하였으며, 충격완충 매체로 유압유 및 공압을 대체할 수 있도록 실리콘 포옴을 후방 사출 성형 방식으로 적용하여 오리피스를 통과한 실리콘 포옴의 변형에너지로 충격에너지를 흡수하게 함으로서 착륙 완충효율을 극대화 할 수 있도록 검토하였다.

  • PDF

Development of Deployment Test Equipment Suitable for Single Large Solar Panel (하나의 큰 태양전지판에 적합한 전개시험장치 개발)

  • Moon, Hong-Youl;Park, Sangho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.7
    • /
    • pp.583-591
    • /
    • 2018
  • In this paper, we propose a new deployment test equipment that is characterized for the deployment test of single large solar panel with tape spring hinge. To perform the deployment test on ground, a device that takes gravity compensation into account should be used to create a zero gravity environment similar to that in orbit. We analyzed the advantages and disadvantages of the most commonly used deployment test equipment in the past through simple conceptual design, analysis, and tests to judge whether it is applicable to the deployment of the solar panel to be tested. A dummy frame was proposed to reduce the air drag effect during on-ground test and a self-aligning ball bearing and adjusting screws were applied to the deployment test equipment to solve the alignment problem with the gravity axis. And a horizontal bearing for radial movement applied to compensate for the change of the axis of the tape spring hinge. From these, we solved the problems of the conventional deployment test equipment by developing and verifying the new deployment test equipment characterized for the solar panel to be deployed in this paper.

The Performance of the Combined Operation of Sprinkler and Smoke Curtain for Smoke Control in the Sloped Stairway Corridor (경사통로로 전파되는 연기에 대한 스프링클러와 제연커텐의 통합제연성능)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.1-12
    • /
    • 2006
  • In this study, CFD computer simulations by FDS are carried out in order to confirm the performance of the combined operation of both sprinkler system and smoke curtain of 0.54 m depth installed for cooling and blocking the smoke which propagates beneath the sloped ceiling of a stairway corridor of which dimensions are 17.92 m long, 4.00 m wide, and 6.12 m high. It is shown that the response time of sprinklers decreases with fire size and it increases more about 1.1 second in case without smoke curtain than in case with smoke curtain, that the time of smoke transport from the fire source to the stairway outlet decreases considerably with fire size, and that the delay effect of smoke transport is not related to the sprinkler system, whether it is operated or not. This study shows that the combined operation of both sprinkler system and smoke curtain is very effective in smoke cooling, but it is a little for effect on smoke blockage. Although the hazard of skin burn due to radiative heat flux from hot smoke layer is decreased by spray cooling effect, the hazard of smoke suffocation and the weakening of visibility is increased by smoke downdrag and the turbulence of smoke-air mixing due to water spray. These conditions may result in preventing occupants from going out of the stairway during evacuation.

A Study on Characteristics of Fire in Vertical Space Using CFAST (화재시뮬레이션을 이용한 수직공간의 화재특성 분석 연구)

  • Park, Hyun-Jun;Kwon, Jin-Suk;Choi, Jae-Hyouk
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.190-190
    • /
    • 2011
  • 사회 다변화 및 급속한 경제성장과 도시밀집화로 인하여, 화재의 발생으로 인하여 막대한 인명피해 및 대규모의 재산상의 피해가 지속적으로 발생하고 있다. 이러한 화재의 피해를 예측하기 위해서는 실제 규모의 화재실험이 매우 유용하지만, 막대한 비용과 현실적 제약조건으로 인하여 실제 실험에는 많은 어려움이 따른다. 따라서 막대한 예산이 소요되는 실제규모의 화재실험의 대체방법으로 실제를 모사하는 축소모형 화재모의실험 및 컴퓨터를 이용한 화재 시뮬레이션 기법이 널리 이용되고 있다. 본 논문에서는 범용 컴퓨터를 이용한 화재 시뮬레이션 기법(CFAST)을 이용하여 수직 공간 구성을 가지는 단독주택의 화재 성상을 검토하였다. 시뮬레이션 모델로는 단독주택을 대상건물로 하여 2층으로 수직 공간을 가지는 단독주택 건물에 대한 모의 화재 시뮬레이션을 수행 하였다. 화재 시뮬레이션 결과는 각 구획실별 온도, 일산화탄소량, 공기 중 산소량 등을 도출하여 기존 이론에 의한 화재성장 그래프와 시뮬레이션 데이터를 비교하여 정확도를 검토하였다. 본 논문에서는 두가지의 시나리오를 작성하여 화재 시뮬레이션 프로그램의 결과 값을 분석하였다. (1) 시나리오 1 : 화재시뮬레이션 대상건물 1층 거실(2번방)에서 스프링클러 미 설치시 화재가 발생한 경우를 가정하여 수평방향인 3번방과 수직방향인 7번방의 화재 확산 피해정도를 살펴보고, 화재 그래프의 이론값과 실험값의 차이를 비교하여 그 정합성을 검토하였다. 발화물질은 Curtain, TV set, Sofa, Table으로 하며 시간은 60초 간격으로 총 3600초(1시간)를 분석 하였고, 발화지점의 온도, 일산화탄소, 공기중 산소 농도를 분석하였다. (2) 시나리오 2 : 시나리오 1과 동일한 화재발현 조건으로 스프링클러가 설치되어 있을 때 화재 발생 했을 경우, 수평방향인 3번방과 수직방향인 7번방의 화재 확산 피해를 시나리오 1과 비교 검토 하였다. 기존 이론에 의한 화재 성장 그래프와 이번 시뮬레이션 결과값을 토대로 만든 그래프 형태를 비교해보면 두 그래프의 형태가 비슷한 형태를 나타내어 Flash Over 현상과 Back Draft 현상이 이론값과 같은 경향을 나타내고 있음을 확인 할 수 있었다. 따라서, 본 논문에서 수행한 화재 시뮬레이션 기법으로 건축물의 실제 화재시의 피해정도를 예측하는 데 유용하게 활용될 것으로 판단된다.

  • PDF

Analysis of Indoor Thermal Environment and Cooling Effects by Ventilation Condition, and Spray irrigation or Nonspray of Single Span Plastic Greenhouses (환기조건 및 관수에 따른 단동 플라스틱 하우스의 냉방효과와 열환경 분석)

  • 허종철;임종환;서효덕;최동호
    • Journal of Bio-Environment Control
    • /
    • v.9 no.1
    • /
    • pp.27-39
    • /
    • 2000
  • In this study, we quantitatively compare the cooling effects of single span plastic greenhouses by opening or shutting of toot and side vents, and operation of fan or sprinkler. With those variables, we simultaneously made experiments at 4 greenhouses under equivalent conditions. By the experiments, the shutting of roof and side vents caused the high temperature difference of indoor and outdoor which the crops cannot be cultivated. However, the opening of the windows effectively reduced the indoor temperature and showed uniform temperature distribution in the greenhouses. The sprinkler abruptly reduced the indoor temperature, and showed excellent cooling effects. Finally, this paper provides the fundamental data for environmental control in greenhouses.

  • PDF

Active Control of Isolation Table Using $H_\infty$ Control ($H_\infty$ 제어를 이용한 방진대의 능동제어)

  • Kim, Kyu-Young;Yang, Hyun-seok;Park, Young-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.10
    • /
    • pp.3079-3094
    • /
    • 1996
  • Recently, the high-precision vibration attenuation technology becomes the essence fo the seccessful development of high-integrated and ultra-precision industries, and is expected to continue playing a key role in the enhancement of manufacturing technology. Vibration isolation system using an air-spring is widely employed owing to its excellent isolation characteristics in a wide frequency range. It has, however, some drawbacks such as low-stiffness and low-damping features and can be easily excited by exogenous disturbances, and then vibration of table is remained for a long time. Consequently, the need for active vibration control for an air-spring vibration isolation system becomes inevitable. Furthermore, for an air-spring isolation table to be successfully employed in a variety of manufacturing sites, it should have a guaranteed robust performance not only to exogenous disturbances but also to uncertainties due to various equipments which might be put on the table. In this study, an active vibration suppression control system using H.inf. theory is designed and experiments are performed to verify its robust performance. An air-spring vibration isolation table with voice-coil-motors as its actuators is designed and built. The table is modeled as 3 degree-of-freedom system. An active control system is designed based on $H_\infty$control theory using frequency-shaped weighting functions. Analysis on its performance and frequency responce properties are done through numerical simulations. Robust characteristics of$H_\infty$ control on disturbances and model uncertainties are experimentally verified through (i) the transient response to the impact excitation of the table, (ii) the steady-state response to the harmonic excitation, and (iii) the response to the mass change of the table itself. An LQG controller is also designed and its performance is compared with the $H_\infty$ controller.

Development and Analysis of the Autoclave Alternative Composite Material Molding Process Using a Pressure Device (가압장치를 이용한 오토클레이브 대체 복합재료 성형공정 개발 및 분석)

  • Kim, Jung-Soo;Kim, Byung-Ha;Joe, Chee-Ryong
    • Composites Research
    • /
    • v.27 no.6
    • /
    • pp.254-259
    • /
    • 2014
  • In this study, a device and pressure press process that is able to substitute autoclave process is developed. This process complements disadvantages of autoclave process which are long process-time and high production cost. The developed device provides air pressure as well as the vacuum which are greatest feature of autoclave process. The device is sealed using hydraulic pressure to keep the air pressure inside the mold. The transfer of the heat is designed to be direct. The heating and pressure charging time are decreased by reducing the interior space. Tooling cost is reduced dramatically compared to autoclave process. Spring-back phenomenon is measured and compared. The temperatures of several parts of the mold during molding are measured. The fiber volume fraction of the parts molded by autoclave process and by the developed process are compared.

Performance Enhancement of Pneumatic Vibration Isolation Tables in Low Frequency by Active Control (공압능동제어를 이용한 저주파 영역에서의 공압제진대 제진성능 개선에 대한 연구)

  • Shin, Yun-Ho;Oh, Ki-Yong;Lee, Jeung-Hoon;Kim, Kwang-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.1 s.118
    • /
    • pp.72-79
    • /
    • 2007
  • As environmental vibration requirements on precision equipment become more stringent, use of pneumatic isolators has become more popular and their performance is subsequently required to be further improved. Dynamic performance of passive pneumatic isolators is related to various design parameters in a complicated manner and, hence, is very limited especially in low frequency range by volume of chambers. In this study, an active control technique, so called time delay control which is considered to be adequate for a low frequency or nonlinear system, is applied to a single chamber pneumatic isolator. The procedure of applying the tine delay control law to the pneumatic isolator is presented and its effectiveness in enhancement of transmissibility performance is shown based on simulation and experiment. Comparison between passive and active pneumatic isolators is also presented.

Lateral Damper of Subway Vehicle for Preventing Abnormal Impact (지하철 전동차 비정상 충격 방지를 위한 횡댐퍼에 관한 연구)

  • Shin, Yujeong;You, Wonhee;Park, Joonhyuk;Hur, Hyunmoo;Jeon, Juyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.1
    • /
    • pp.17-23
    • /
    • 2013
  • In a subway vehicle, a lateral damper is used for compensating the lateral stiffness deterioration due to the air-spring as a secondary suspension. This lateral damper can reduce the lateral vibration of the carbody. When the damping force of the lateral damper is lowered, the running stability and ride quality of the subway vehicles worsens and the lateral motion of the carbody is increased. In this study, the lateral displacement variation of the carbody according to the damping force of the lateral damper was analyzed by multi-body dynamics to solve the abnormal impact problem during vehicle operation. Furthermore, the noise and vibration due to abnormal impact were considered. An adequate damping coefficient of the lateral damper for the subway vehicle treated in this paper was suggested for preventing abnormal impact.