Air Ventilation Evaluation at Nighttime for the Construction of Wind Corridor in Urban Area (도시지역의 바람길 조성을 위한 야간시간대의 공기순환성 평가)

  • Song, Bong-Geun;Park, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.16 no.2
    • /
    • pp.16-29
    • /
    • 2013
  • The purpose of this study is to evaluate air ventilation using wind patterns of MetPhoMod program at nighttime focused on Changwon-si, Gyeongsangnam-do. Evaluation indices of air ventilation are wind resistant and retention used by results of each wind speed and diversity. The results are as follows. Vulnerable areas of air ventilation are Bonglim-dong, Bansong-dong, Yongji-dong and so on. In high-rise apartment, commercial area and single residential area of Yongji-dong, Sangnam-dong and Sapa-dong, wind is stagnated by high buildings. Therefore, these areas should construct urban spaces to circulate the wind. And to inflow persistingly the fresh wind generated in a rural area, we think that the construction of wind corridor is suggested by development plan and policy wind corridor.

블라인드 장착에 따른 실내 공기 순환 연구

  • Nam, Do-U;Hwang, Jae-Min
    • Proceeding of EDISON Challenge
    • /
    • 2016.03a
    • /
    • pp.625-627
    • /
    • 2016
  • 본 논문은 EDISON CFD의 전처리기, eMEGA를 이용하여 격자를 생성하고, 2차원 정렬 격자 기반 비압축성 해석자를 이용하여 유동해석을 진행한 뒤 후처리기, eDAVA를 통해 유동선을 그려 블라인드 장착에 따른 실내 공기 순환에 대한 연구 내용을 담고 있다. 본 연구는 시중에 판매중인 사생활 보호용 블라인드를 포함, 여러 블라인드의 장착 여부에 따라 실내 내부 공기 순환의 양상을 확인하고 실제로 블라인드 장착 시 실내환기에 어떤 영향을 주는지 유동 선을 통해 확인해 보았다. 블라인드 미장착시, 실내 전체적으로 공기가 고루 순환되는 모습을 보였으며, 블라인드 장착 시 대체로 블라인드 형태에 따라 유동이 이동하는 것을 볼 수 있었다. 본 연구는 사생활 보호와 환기 효율성의 관점에서의 소비자 선택권에 영향을 미치는 효과를 가져 올 것으로 보인다.

  • PDF

액체금속로 피동 원자로용기냉각계통의 특성 분석

  • 위명환;심윤섭
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.374-378
    • /
    • 1996
  • 피동 원자로용기 냉각계통은 원자로 용기를 둘러싸고 있는 격납공기 외부가 공기에 자연순환에 의해 냉각하는 방식으로 공기 흐름 구동력은 원자로용기의 외부 유로의 공기와 주변 대기와의 밀도 차이에 의하여 피동적으로 형성됨에 따라 높은 작동 신뢰성이 보장된 개념으로서 본 연구에서는 공기입구 위치에 따른 영향 및 격납용기와 유로 벽면간의 복사 효과 까지를 고려 할 수 있도록 해석 모형을 개선 시키고 개선된 모형을 이용하여 계통을 구성하는 설계인자들이 계통의 성능 및 크기에 미치는 영향등을 분석하였다. 이러한 분석을 통하여 공기의 입구 위치가 계통의 열제거용량에 미치는 영향, 상향공기 유로에서의 복사 열전달 고려 유무가 해석 결과에 미치는 영향 그리고 설계인자와 계통 성능간의 상관성을 밝혔다.

  • PDF

A Study on the In-Vitro Test of Thrombogenesis in Centrifugal Biopump (원심성 바이오 펌프를 이용한 혈전 생성의 생체 외 검사에 관한 연구)

  • Na, Myung-Hoon;Kim, Won-Gon;Kim, Joo-Hyun;Kim, Mee-Hyung;Yu, Jae-Hyeon;Lim, Seung-Pyung;Lee, Young
    • Journal of Chest Surgery
    • /
    • v.32 no.10
    • /
    • pp.863-873
    • /
    • 1999
  • 배경: 혈전 생성은 심혈관계 삽입물이나 순환 보조장치의 발전에 있어서 중요한 문제이므로 이러한 장치들의 혈전성에 대한 평가는 필수적이다. 따라서 이러한 장치들의 혈전성 연구를 시행하기 위한 효과적인 생체 외 실험 방식이 개발되어 원심성 순환 펌프의 발전에 큰 도움이 되고 있으며, 최근 엄밀하게 혈액과 공기의 접촉을 차단하는 방식이 믿을 수 있는 생체 외 실험 방식으로 강조되고 있다. 본 논문에서는 모의 순환 회로를 이용하여 기존에 행해진 연구 방법 상의 공기 접촉에 따른 핼액 응고 기전의 활성화 여부를 알아보기 위하여 공기 접촉 여부에 따른 혈액 인자의 변화를 관찰하여 확인하고, 또한 회로 내에서 생성된 혈전을 생체 내에서 형성된 혈전과 비교 분석하여 이 모의 순환 회로를 이용한 생체 외 검사가 새로 고안된 심혈관계 장치들의 혈전성을 평가하는데 있어서 동물실험을 대신할 수 있다는 기존의 주장을 검증하고자 하였다. 연구재료 및 방법: 바이오펌프를 이용한 같은 모의 순환 회로 한 쌍을 준비하고 동일 개체에서 얻은 헤파린을 첨가한(1u/$m\ell$) 신선한 혈액을 공기와 접촉시키지 않도록 한 A-회로와 공기와 접촉시킨 B-회로에 충전시켜 실험을 동시에 진행하여 결과를 얻었으며 총 12번 시행하였다. 회로에 충전한 혈액의 activated clotting time(ACT)은 정상의 3~5배였으며 ACT가 정상 범위의 1.5배가되면 실험을 끝냈고, Hematocrit(HCT), 혈소판, 동맥혈가스분석(ABGA), factor Ⅷ, factor \ulcorner, 섬유소원, thromboxane B2(TXB2), free hemoglobin(fHb) 등을 측정하였다. 실험이 끝난 후 A-회로와 B-회로에서 얻은 각 검사를 평가하고 분석하였으며 생성된 혈전을 생체 내에서 생성된 혈전과 조직 검사로 비교하였다. 본 연구의 자료분석은 SPSS 통계 프로그램을 이용하였고 유의수준 0.05를 기준으로 유의도를 판단하였다. 결과: 정상 ACT는 186.9$\pm$20.5초(평균$\pm$표준편차)이었고, 헤파린을 넣은 초기 ACT는 982.2$\pm$165.5초이었으며, 실험시간은 보통 60분에서 180분 사이였다. HCT, fHb, 혈소판, TXB2, factor Ⅷ, factor \ulcorner, 섬유원소의 초기값은 35.5$\pm$3.2%, 12.4$\pm$6.5 mg/dL, 354$\pm$56($\times$103)/$\mu$L, 72.6$\pm$15.1 mg/dL, 29.3$\pm$1.2%, 137.9$\pm$42.1 mg/dL, 그리고 17.7$\pm$9.7%이었다. 공기 접촉에 따른 차이를 보았을 때 ACT(p=0.398), HCT(p=0.988), fHb(p=0.898), 혈소판 (p=0.904), TXB2(p=0.985), factor Ⅷ(p=0.872), factor \ulcorner(p=0.489), 섬유원소(p=0.973)으로 전 예에서 통계적 유의성이 없었다. 실험 후 양 군에서 생성된 혈전의 현미경 소견은 B-회로의 혈전에 여러 군데 공기 방울이 관찰되는 것 이외에 A-회로에서 생성된 혈전과 차이가 없었고, 생체에서 생성된 혈전과 비교했을 때 그 양상이 같았다. A-회로와 B-회로에서 생성된 혈전의 총 량은 8.4$\pm$3.7 mL와 9.4$\pm$3.1 mL로 통계상 유의성은 없었다. (p=0.624). 결론: 모의 순환 회로를 이용한 혈전성 평가를 위한 생체 외 실험에 있어서 공기와의 접촉 여부는 혈액 응고 기전의 활성화나 혈전 생성에 별다른 영향을 미치지 않는다. 모의 순환 회로에서 형성된 혈전과 문헌에 있는 인체 내에서 형성된 혈전을 비교한 결과 그 형태가 일치하므로 이 모의 순환회로를 이용한 실험이 동물실험을 대신할 수 있다고 판단된다.

  • PDF

A Study on Health Check Solution using Indoor Air Purifier (실내 내장형 공기순환기를 이용한 헬스 체크 솔루션에 관한 연구)

  • Yang, Hee-Tak;Oh, Ji-Su;Lee, Keun-Ho
    • Journal of Internet of Things and Convergence
    • /
    • v.3 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • In the future a future type new city and the latest apartment will be built, and the IoT technology will be constructed and combined in large numbers indoors of ordinary households. An air cleaner that makes people in it comfortable is built in, and the suction port that sucks in the air of the air purifier and the discharge port that discharges it are set up around the room and come out. However, this is impossible to adjust because there is only a central switch on / off. Also, consuming a lot of electricity so that many electricity charges are caused by huge electricity consumption will eventually be a waste of resources. This would like to be adjusted and driven through the fine dust detection device to the room built-in air purifier and that has provided a solution to save electricity. In addition, since it exists in and around the room, you can grasp the position of the person and connect to the home network to enhance the convenience. Also, through analysis of the air, we provide a health-check solution that checks the user's health and adjusts it appropriately.

Mixing effect of aeration in thermally stratified water (물순환장치 가동에 따른 온도 성층화 혼합 효과)

  • Choi, Seongeun;Hwang, Jin Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.61-61
    • /
    • 2021
  • 온도 성층화는 많은 저수지와 댐에서 흔히 발생하는 현상으로 호수나 저수지의 표면 온도가 바닥보다 상대적으로 높아 깊이에 따른 열 구배를 나타낸다. 이러한 온도 성층화 현상은 여름철과 같이 상부와 하부의 온도 차가 클수록 안정적이게 나타나며 이러한 층화 현상으로 수직 확산이 제어되어 수질에 영향을 미친다고 알려져 있다. 따라서 댐이나 호수 등 층화 현상이 심한 유체 내부 바닥에 물순환장치를 설치하여 외부로부터 공기를 끌어와 하부에서 공기를 분출하여 온도 성층을 약화시키기도 한다. 물순환 장치를 설비하면 수체의 혼합이 용이해지며 물질전달이 개선되어 수질이 향상된다. 국내의 경우 대청댐, 보령댐, 영주 댐 등 많은 국내 댐 내부에 물순환장치가 설비되어있다. 본 연구에서 댐의 물순환장치의 성능을 파악하기 위해 산기식 물순환 장비가 설치되어있는 영주댐을 연구 대상 지역으로 잡았다. 연구지역의 계절별 성층구조 및 특성을 조사하기 위해, 봄, 여름, 가을 영주댐에 방문하여 관측 자료를 취득하였으며 물순환 장치는 봄철의 경우만 가동하였다. 봄철의 물순환 장치 가동 전후 관측 데이터를 바탕으로 수치모형실험을 실행하여 관측 결과와 비교 및 검증하였다. 이를 바탕으로 여름, 가을에 물순환장치를 가동하였을 경우 댐 내부 수체의 혼합과정을 살펴보는 연구를 진행하였다. 본 연구는 CFD (Computational Fluid Dynamic) 시뮬레이션을 수행하기 위해 오픈 소스 소프트웨어 OpenFOAM(version 4.0)에서 열 전달이 포함되어있는 비압축성 VOF 솔버를 사용하였다. 본 솔버는 물과 공기를 동시에 나타낼 수 있으며 온도의 확산 방정식을 포함하고 있다. 또한 유동해석 수행 시 사용한 물순환장치의 효울은 실제 장치의 효율과 동일하다. 본 연구의 목표는 다음과 같다. (1) 관측만으로 파악하기 어려운 수체의 혼합거동을 유동해석 자료를 통해 면밀히 살펴보고 (2) 봄철 물순환 장치가 작동하기 전후 자료를 바탕으로 여름 및 가을철 물순환장치 가동 전후 데이터를 유동해석 자료로 취득한다. (3) 또한 물순환장치 가동 전후 데이터를 통해 계절별 혼합 효율을 취득한다.

  • PDF

Evaluation of Cooling Energy Saving through Applying Aisle Partition System on a Data Center Server Room (파티션 시스템 적용을 통한 기존 데이터센터 서버실의 냉방 에너지 절감 성능평가)

  • Park, Jong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.726-733
    • /
    • 2016
  • In this study, a computer simulation of the three types of air distribution systems, open type system, aisle partition system and aisle containment system, to evaluate the applicability of the aisle partition system on a data center server room. The variables of the simulation were the height and location of the partition fixed on the top server rack. The energy efficiency of the air distribution systems were confirmed to be excellent in the order of the aisle containment system, aisle partition system, and open type system. In the cold aisle partition system, the height of the partition that can be effective in saving cooling energy by obstructing sufficient air recirculation was found to be more than 0.9m. In the hot aisle partition system, the height of the partition was found to be more than 0.8m.

Effects of Animal Additives on the Fundamental Properties of Mortar and Concrete (동물성 첨가제가 모르타르 및 콘크리트의 기초 물성에 미치는 영향)

  • Song, Jin-Woo;Moon, Seung-Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.1
    • /
    • pp.69-75
    • /
    • 2012
  • The study was conducted to determine the effects of adding pig blood as an admixture to both mortar and concrete. The mortar tests included the determination of its unit weight, flow and its compressive strength. Moreover, the concrete test includes the determination of air content, slump, bleeding, setting time compressive strength and freeze-thaw resistance of the material. As the test result, the utilization of pig blood, as an additive to both mortar and concrete mixtures causes air entrainment. The mortar flow increased and both the unit weight and the compressive strength of mortar decreased. As the blood replacement rate increases, the air content decreases over time, the setting and amount of bleeding showed a tendency to decline and reduced compressive strength, and the freeze-thaw resistance of the concrete increased.

  • PDF

공기순환형 구조체 축열 공조시스템

  • 이정재;정광섭
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.8
    • /
    • pp.15-18
    • /
    • 2002
  • 축열 공조방식 중 현재 가장 많이 보급되고 있는 방식은 빙축열 방식과 수축열 방식이다. 본래 축열식 공조는 열원 용량을 감소하고, 값싼 심야전력을 통해서 운전비용(running cost)의 절감을 목적으로 하지만, 열을 저장하기 위한 "축열조"가 필요하므로, 필연적으로 초기투자비(intial cost)의 증가를 동반하며, 기존의 건물에는 쉽게 적용할 수 없는 등의 문제점이 있다. 따라서 축열을 위한 초기비용을 증가시키지 않는 축열식 공조방식으로서 건축물 자체가 가지는 높은 열용량에 착안하여 구조체 축열에 관한 연구가 최근 활성화되고 있다. 구조체 축열은 건축물 그 자체를 축열 매체로 이용하기 때문에 별도의 축열조가 필요 없고, 구조체 로부터의 "복사"형태로 거주영역에 직접적으로 작용하여 실내의 온열환경을 향상시킬 수 있다. 이 때문에 2차측 공조기의 용량을 절감시킬 수 있고, 축열 부위에서의 열반송이 필요없는 등, 구조체 축열 시스템은 기존의 빙축열과 수축열 방식에서는 없는 여러가지 장점을 가지고 있다. 구조체 축열 공조시스템은 기존의 공조시스템 중에서 급기구 부위만을 변경하여 주간에서 종래의 공조시스템과 같이 실내로 공조 공기를 급기하고, 야간에는 급기구에 설치된 댐퍼를 조절하여 천정면으로 공조 공기를 급기함으로써 구조체에 열을 축열시키는 방안이다. 본 시스템은 기존의 설비시스템을 이용하여 건축물의 구조체를 축열, 공조개시전 및 주간의 부하를 대폭 줄임으로써 에너지를 절감시킬 수 있다는 장점을 갖는다. 따라서 구조체 축열 공조시스템은 "지구환경 유지.전력부하 평준화.안전성.에너지 절약.비용절감.쾌적성"의 모든 조건을 만족시키는 유력한 차세대 공조 방식이 될 것으로 판단되며, 본 보에서는 공기순환형 구조체 축열시스템을 소개하고자 한다.

  • PDF