• 제목/요약/키워드: 공기냉각

검색결과 425건 처리시간 0.019초

물-공기 원추형 분무시스템에 있어서 분무냉각 막비등 열전달에 관한 연구 (Study on Film Boiling Heat Transfer of Spray Cooling in Air-Water Full Cone Spray System)

  • 김영찬;윤승민
    • 대한기계학회논문집B
    • /
    • 제30권12호
    • /
    • pp.1236-1242
    • /
    • 2006
  • The local heat flux of spray cooling in the film boiling region were experimentally investigated for the spray region of $D_{max}$ = $0.005{\sim}0.03m^3/(m^2s)$. A twin-fluid full cone spray nozzle was employed for the experiment and the distributions of droplet flow rates were obtained for air-water full cone sprays. A stainless steel block was cooled down from initial temperature of about $800^{\circ}C$ by full cone spray. In the region near the stagnation point, it was found that the experimental data are in good agreement with the results predicted from the correlations between the local heat transfer and the local droplet flow rate proposed in the previous report. However, it was found that the experimental data of $D_r$ > $0.01m^3/(m^2s)$ are a little smaller than the results predicted from the correlations.

도계장의 도계공정별 및 닭고기의 저장 중 미생물의 증감추이

  • 서미영;김윤숙;차성관
    • 한국축산식품학회:학술대회논문집
    • /
    • 한국축산식품학회 2004년도 정기총회 및 제33차 춘계 학술대회
    • /
    • pp.160-162
    • /
    • 2004
  • 본 연구는 도계장의 HACCP 적용에 따른 자료 확보를 위하여 도계공정 단계별 및 닭고기의 저장중의 미생물 증감 추이를 조사하였다. 도계장 규모별로 대규모 2곳과 소규모 2곳을 선정하여 여름, 가을, 겨울, 봄에 걸쳐 각 도계장마다 2회씩 시료를 채취하여 미생물검사를 도계공정 단계별로 실시한 결과 도계공정 초기인 내장적출 전, 후 단계에서 채취한 시료에서는 $10^5{\sim}10^6CFU/m{\ell}$이었다가 세척, 냉각 단계를 거쳐 냉장 단계에서는 $10^3{\sim}10^4\;CFU/m{\ell}$ 수준으로 균수가 감소하는 것으로 나타났다. 낙하세균수 조사결과는 계절에 관계없이 탕적실과 내장 적출실의 공기오염도는 높은 편이었고, 세척실과 냉각실은 양호하였으며 냉장실에서는 colony가 거의 검출되지 않았다. 닭고기를 $4^{\circ}C$에서 저장하였을 때 미생물 균 수의 변화를 조사한 결과 일반세균수는 저장 초기에 미세한 증가를 보이다가 저장후기(6${\sim}$12일) 급격한 증가를 보여 주었고, 조사한 미생물 중 내냉성균수가 가장 높은 균 수의 증가를 나타내었다. 대장균, 대장균군은 저장 초기 $10^1\;CFU/m{\ell}$ 수준이다가 저장 6일 이후로는 검출되지 않았다. 효모와 곰팡이 균은 $4^{\circ}C$ 저장기간 중 균수가 꾸준히 증가하는 경향을 보여 주었다.

  • PDF

방폭 패널 컨디션 자동화 시스템(1) (Automation System of Explosion-Proof Panel Condition)

  • 황대현;최광일;배영철
    • 한국전자통신학회논문지
    • /
    • 제15권2호
    • /
    • pp.253-258
    • /
    • 2020
  • 우리나라의 석유화학산업단지는 폭발성 가스와 가연성 가스로 인하여 언제나 폭발 위험성이 높다. 이러한 폭발을 방지하기 위한 방법으로 석유화학산업단지의 대부분 설비에 방폭 성능을 요구하고 있다. 방폭용으로 현재 사용하고 있는 제어기 패널은 패널의 내부와 외부의 압력(양압)과 온도를 일정하게 유지를 위해 외부에서 수동으로 공기를 주입하는 방식을 사용하고 있다. 이에 본 논문은 자동으로 온도를 제어할 수 있도록 패널 내부의 온도에 따라 가열과 냉각을 자동으로 수행하는 자동 온도조절기를 제안한다.

알루미늄 합금 실린더 블럭을 적용한 가솔린 엔진의 냉각계 개발 (The development of cooling system in the gasoline engine with the aluminum alloy cylinder block)

  • 한덕주;민병순;최재권
    • 오토저널
    • /
    • 제17권3호
    • /
    • pp.11-18
    • /
    • 1995
  • 본 논문에서는 주철 라이너를 삽입한 알루미늄 블럭 엔진 개발과정에서 주조 불량이 발생하였을때, 냉각계에 일어나는 제반 현상을 분석하고, 이를 해결해 나가는 과정을 기술하였다. 이를 위하여 주철 블럭과 알루미늄 블럭을 장착한 엔진의 피스톤 온도와 블럭의 열유속, 열정산을 측정하였다. 측정한 결과는 다음과 같다. 1. 알루미늄 블럭 제작시 주철 라이너와 알루미늄 블럭 사이에 공기층이 크거나, 용탕 충진이 불완전한 주조 불량이 발생하면 열접촉 저항이 커져 엔진 열전달 경로에 큰 영향을 준다. 2. 알루미늄 블럭 제작시 주조 불량이 발생하면 피스톤에서 라이너로의 전열량이 줄어듦에 따라 냉각수로의 전열량은 감소하는데, 6,000rpm, 전부하에서 알루미늄 블럭의 출력 대비 냉각수로의 방열량의 비는 38.3%이고, 주철 블럭은 44.1%이다. 3. 알루미늄 블럭 제작시 주조 불량이 발생하면, 피스톤 온도가 15-20.deg.C 정도 상승하여 피스톤 손상을 유발시킬 수 있다. 4. 알루미늄 블럭의 주조가 완벽하게 되어 주철 라이너와 알루미늄 몸체 사이에서의 열접촉저항이 없어지면, 스토로크 방향에 따른 금속면 온도 분포가 균일하게 된다. 5. 실린더 라이너의 주조상태 개선없이 오일젯을 사용한 결과 피스톤의 온도를 만족할 만한 수준으로 감소시켰다. 6. 6000rpm, 전부하에서 오일젯 적용시 출력 대비 냉각수로의 방열량의 비가 38.3%에서 36.2%로 감소하고, 출력대비 오일로의 방열량의 비는 9.6%에서 11.2%로 증가한다. 7. 오일젯 작용시 오일 펌프의 용량 증대와 오일 쿨러의 장착이 필수적이다.

  • PDF

자동차 엔진냉각계의 해석 프로그램의 개발 (Development of Simulation Program of Automotive Engine Cooling System)

  • 배석정;이정희;최영기
    • 설비공학논문집
    • /
    • 제15권11호
    • /
    • pp.943-956
    • /
    • 2003
  • A numerical program has been developed for the simulation of automotive engine cooling system. The program determines the mass flow rate of engine coolant circulating the engine cooling system and radiator cooling air when the engine speed is adopted by appropriate empirical correlation. The program used the method of thermal balance at individual element through the model for radiator component in radiator analysis. This study has developed the program that predicts the coolant mass flow rate, inlet and outlet temperatures of each component in the engine cooling system (engine, transmission, radiator and oil cooler) in its state of thermal equilibrium. This study also combined the individual programs and united into the total performance analysis program of the engine cooling system operating at a constant vehicle speed. An air conditioner system is also included in this engine cooling system so that the condenser of the air conditioner faces the radiator. The effect of air conditioner to the cooling performance, e.g., radiator inlet temperature, of the radiator and engine system was examined. This study could make standards of design of radiator capacity using heat rejection with respect to the mass flow rate of cooling air. This study is intended to predict the performance of each component at design step or to simulate the system when specification of the component is modified, and to analyze the performance of the total vehicle engine cooling system.

에어-오일 냉각방식에 의한 고경도재료의 선삭 (Turning of Hardened Materials Using the Air-oil Cooling System)

  • 정보구;고태조;김희술
    • 한국정밀공학회지
    • /
    • 제14권8호
    • /
    • pp.73-81
    • /
    • 1997
  • The hard turning process defined as a single point turning of materials harder than $H_{R}$C 58 differs from conventional turning because of hardness of the work materials and cutting toos needed in the process. In hard turning, tool life is very short, of the order of a few minutes, during which the cutting tool is subjected to the extremes of stress and temperature. In this regard, it is well known that CBN tool is proper for this process in spite of expensive cost. In this research, we studied the feasibility of the use of the low cost cutting tool such as a aTiN coated tool. To this end, a new cooling system was designed with an air-oil method for reducing tool temperature, which is based on the principle of air vortex flow. That is, the outlet temperature of the air becomes aver 20 .deg. C lower than atmosphere temperature by entering pressurized air of 5kgf/c $m^{2}$ into the inlet. This cooled air ejected to the top of the cutting tool lowered tool temperature, which reduced the wear of a TiN coated tool by the 30% of CBN tool life with respect to the same cutting length.h.

  • PDF

자동차 냉각기 호스용 EPDM고무의 노화에 대한 비파괴 특성평가 (Nondestructive Characterization of Degradation of EPDM Rubber for Automotive Radiator Hoses)

  • 곽승범;최낙삼;최윤정;신세문
    • 비파괴검사학회지
    • /
    • 제25권5호
    • /
    • pp.368-376
    • /
    • 2005
  • 자동차용 냉각기 호스는 열과 기계적 하중 하에서 공기와 부동액의 접촉 스트레스로 인해 노화와 고장이 일어날 수 있다. 본 연구에서는 냉각기 호스재료인 EPDM(ethylene-propylene diene monomer)고무에 대해 열가속 및 산소 스트레스, 전기화학적 스트레스에 의한 표피층의 노화거동을 비파괴 평가하였다. 열가속 및 산소노화 시험결과 신장률의 저하와 함께 IRHD(International Rubber Hardness Degrees)경도가 증가하였다. 전기화학적 노화(electro-chemical degradation: ECD) 시험에서는 에틸렌글리콜 수용액의 침투로 인해 무게가 증가하였으며 신장률과 경도는 크게 저하되었다 또한 에틸렌글리콜 수용액이 표피층뿐만이 아니라 내부에까지 침투하여 고무내부구조와 미크로경도분포가 깊이에 따라 변화되었다. 즉, 열가속 및 산소노화와 ECD 노화는 미크로 경도와 화학구조분석에 의해 비파괴적 특성 평가가 가능함을 보였다.

PHP를 결합한 알루미늄 히트싱크의 냉각성능에 관한 연구 (A Study on Cooling Performance of Aluminium Heat Sink with Pulsating Heat Pipe)

  • 김종수;하수정;권용하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1016-1021
    • /
    • 2011
  • 열전소자를 이용한 냉각 장치에 있어서 열전소자발열부측의 제거 열량은 제품의 성능 및 적용범위를 결정하는 주요변수가 되므로 히트싱크의 열저항을 최소화 할 수 있는 최적 조건의 히트싱크 설계를 필요로 한다. 발열부가 작고 상대적으로 히트싱크 면적이 커서 히트싱크 전체면으로 열확산이 필요한 경우 히트싱크의 방열 성능을 향상시키기 위하여 작동유체 R-22의 진동형 히트파이프를 이용하여 열전소자의 발열부측의 발열량(30W, 60W, 80W, 100W)과 공기 유속(1~4 m/s)에 따른 히트싱크의 열저항 실험 및 수치해석 결과와 비교 분석을 통해 히트싱크의 냉각 성능을 향상 시킬 수 있는 방법을 연구하였다.

충돌제트에서의 횡방향 유동 감소를 위한 파형 구조의 유동 및 열전달에 관한 연구 (A Study on Fluid Flow and Heat Transfer of a Corrugated Structure for Crossflow Reduction of Impingement Jet)

  • 황병조;김선호;주원구;조형희
    • 대한기계학회논문집B
    • /
    • 제41권5호
    • /
    • pp.329-339
    • /
    • 2017
  • 충돌제트는 제트가 충돌하는 정체 영역에 매우 높은 열전달을 제공하기 때문에 다양한 분야에서 적용되고 있다. 그러나 제트가 벽면에 부딪친 후 벽면 제트에 의해 야기되는 충돌 챔버 내의 횡방향 유동은 여러 개의 제트로 구성된 배열제트인 경우 하류에 있는 제트 유동을 방해하거나 휘게 할 수 있으며, 이로 인해 배열 충돌제트의 냉각 성능은 감소하게 된다. 파형 구조는 하류 제트에서의 횡방향 유동영향을 줄이기 위해 인접한 충돌 제트 사이에 있는 파형 속에 사용된 냉각 공기를 유입시키는 역할을 하며, 이러한 파형 구조에서의 유동 및 열전달 특성에 대해 수치해석을 수행하였다. 3차원, 정상상태, 비압축성 유동으로 고려하고 해석하였으며 ANSYS-CFX 15.0 코드를 사용하였다. 파형 구조의 형상 변수가 배열 충돌제트의 횡방향 유동 억제에 미치는 영향을 제시하고 분석하였다.

소형 오존발생장치의 전력제어와 냉각효과에 관한 연구 (A Study on Cooling Effect and Power Control of a Mini Ozonizer)

  • 우성훈;박승조;윤성윤;박지호;우정인
    • 대한환경공학회지
    • /
    • 제28권1호
    • /
    • pp.97-103
    • /
    • 2006
  • 본 논문은 미세 오존 출력을 얻을 수 있는 자동제어형 오존발생장치의 제어기법을 제시하고, 또한 무성방전에 의한 오존발생장치의 유입공기를 공극에서 저온인 $2^{\circ}C$까지 냉각 하여 포화 확산도가 높은 고밀도 탈취용 오존을 발생시킬 수 있는 기법을 제시한다. 고주파수의 오존방전 노이즈에 의한 전원파형의 불량화를 보상하기 위해서 디지털 궤환 제어시스템을 구성하고, 방전관의 등가 커패시터의 전압과 전류를 검출하여 2중의 제어루프를 설계한다. 부하변동에 따르는 과도상태 응답특성을 개선하고 제어기의 연산 지연시간을 보상하기 위하여 연산시간을 전원장치 플랜트의 고유한 파라미터로 가정하여 플랜트모델에 포함시켜 모델링한다. 제안된 오존 발생기는 고농도 고효율의 오존방전 시스템의 입력전원에서 고주파방전노이즈가 제거되어 정현적으로 되며 2배 이상의 안정된 오존출력을 얻는 것을 실험적으로 입증한다.