• Title/Summary/Keyword: 공기냉각

Search Result 425, Processing Time 0.031 seconds

Study on Film Boiling Heat Transfer of Spray Cooling in Air-Water Full Cone Spray System (물-공기 원추형 분무시스템에 있어서 분무냉각 막비등 열전달에 관한 연구)

  • Kim, Yeung-Chan;Yun, Seung-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1236-1242
    • /
    • 2006
  • The local heat flux of spray cooling in the film boiling region were experimentally investigated for the spray region of $D_{max}$ = $0.005{\sim}0.03m^3/(m^2s)$. A twin-fluid full cone spray nozzle was employed for the experiment and the distributions of droplet flow rates were obtained for air-water full cone sprays. A stainless steel block was cooled down from initial temperature of about $800^{\circ}C$ by full cone spray. In the region near the stagnation point, it was found that the experimental data are in good agreement with the results predicted from the correlations between the local heat transfer and the local droplet flow rate proposed in the previous report. However, it was found that the experimental data of $D_r$ > $0.01m^3/(m^2s)$ are a little smaller than the results predicted from the correlations.

도계장의 도계공정별 및 닭고기의 저장 중 미생물의 증감추이

  • Seo, Mi-Yeong;Kim, Yun-Suk;Cha, Seong-Gwan
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2004.05a
    • /
    • pp.160-162
    • /
    • 2004
  • 본 연구는 도계장의 HACCP 적용에 따른 자료 확보를 위하여 도계공정 단계별 및 닭고기의 저장중의 미생물 증감 추이를 조사하였다. 도계장 규모별로 대규모 2곳과 소규모 2곳을 선정하여 여름, 가을, 겨울, 봄에 걸쳐 각 도계장마다 2회씩 시료를 채취하여 미생물검사를 도계공정 단계별로 실시한 결과 도계공정 초기인 내장적출 전, 후 단계에서 채취한 시료에서는 $10^5{\sim}10^6CFU/m{\ell}$이었다가 세척, 냉각 단계를 거쳐 냉장 단계에서는 $10^3{\sim}10^4\;CFU/m{\ell}$ 수준으로 균수가 감소하는 것으로 나타났다. 낙하세균수 조사결과는 계절에 관계없이 탕적실과 내장 적출실의 공기오염도는 높은 편이었고, 세척실과 냉각실은 양호하였으며 냉장실에서는 colony가 거의 검출되지 않았다. 닭고기를 $4^{\circ}C$에서 저장하였을 때 미생물 균 수의 변화를 조사한 결과 일반세균수는 저장 초기에 미세한 증가를 보이다가 저장후기(6${\sim}$12일) 급격한 증가를 보여 주었고, 조사한 미생물 중 내냉성균수가 가장 높은 균 수의 증가를 나타내었다. 대장균, 대장균군은 저장 초기 $10^1\;CFU/m{\ell}$ 수준이다가 저장 6일 이후로는 검출되지 않았다. 효모와 곰팡이 균은 $4^{\circ}C$ 저장기간 중 균수가 꾸준히 증가하는 경향을 보여 주었다.

  • PDF

Automation System of Explosion-Proof Panel Condition (방폭 패널 컨디션 자동화 시스템(1))

  • Hwang, Dae-Hyeon;Choi, Kwang-Il;Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.253-258
    • /
    • 2020
  • Petrochemical industry complex in Korea always has high riskiness due to explosive and inflammable gases. To prevent these explosion, most facility of petrochemical industry complex requires the performance of explosive proof. The control panel, which is used as explosive proof, has been used the air injection method by manually from outside to constantly keep the temperature and pressure between inside and outside of the panel. In this paper, we propose the automatic temperature controller, which performs automatic heating and cooling according to temperature inside the panel in order to control temperature automatically.

The development of cooling system in the gasoline engine with the aluminum alloy cylinder block (알루미늄 합금 실린더 블럭을 적용한 가솔린 엔진의 냉각계 개발)

  • 한덕주;민병순;최재권
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.17 no.3
    • /
    • pp.11-18
    • /
    • 1995
  • 본 논문에서는 주철 라이너를 삽입한 알루미늄 블럭 엔진 개발과정에서 주조 불량이 발생하였을때, 냉각계에 일어나는 제반 현상을 분석하고, 이를 해결해 나가는 과정을 기술하였다. 이를 위하여 주철 블럭과 알루미늄 블럭을 장착한 엔진의 피스톤 온도와 블럭의 열유속, 열정산을 측정하였다. 측정한 결과는 다음과 같다. 1. 알루미늄 블럭 제작시 주철 라이너와 알루미늄 블럭 사이에 공기층이 크거나, 용탕 충진이 불완전한 주조 불량이 발생하면 열접촉 저항이 커져 엔진 열전달 경로에 큰 영향을 준다. 2. 알루미늄 블럭 제작시 주조 불량이 발생하면 피스톤에서 라이너로의 전열량이 줄어듦에 따라 냉각수로의 전열량은 감소하는데, 6,000rpm, 전부하에서 알루미늄 블럭의 출력 대비 냉각수로의 방열량의 비는 38.3%이고, 주철 블럭은 44.1%이다. 3. 알루미늄 블럭 제작시 주조 불량이 발생하면, 피스톤 온도가 15-20.deg.C 정도 상승하여 피스톤 손상을 유발시킬 수 있다. 4. 알루미늄 블럭의 주조가 완벽하게 되어 주철 라이너와 알루미늄 몸체 사이에서의 열접촉저항이 없어지면, 스토로크 방향에 따른 금속면 온도 분포가 균일하게 된다. 5. 실린더 라이너의 주조상태 개선없이 오일젯을 사용한 결과 피스톤의 온도를 만족할 만한 수준으로 감소시켰다. 6. 6000rpm, 전부하에서 오일젯 적용시 출력 대비 냉각수로의 방열량의 비가 38.3%에서 36.2%로 감소하고, 출력대비 오일로의 방열량의 비는 9.6%에서 11.2%로 증가한다. 7. 오일젯 작용시 오일 펌프의 용량 증대와 오일 쿨러의 장착이 필수적이다.

  • PDF

Development of Simulation Program of Automotive Engine Cooling System (자동차 엔진냉각계의 해석 프로그램의 개발)

  • 배석정;이정희;최영기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.11
    • /
    • pp.943-956
    • /
    • 2003
  • A numerical program has been developed for the simulation of automotive engine cooling system. The program determines the mass flow rate of engine coolant circulating the engine cooling system and radiator cooling air when the engine speed is adopted by appropriate empirical correlation. The program used the method of thermal balance at individual element through the model for radiator component in radiator analysis. This study has developed the program that predicts the coolant mass flow rate, inlet and outlet temperatures of each component in the engine cooling system (engine, transmission, radiator and oil cooler) in its state of thermal equilibrium. This study also combined the individual programs and united into the total performance analysis program of the engine cooling system operating at a constant vehicle speed. An air conditioner system is also included in this engine cooling system so that the condenser of the air conditioner faces the radiator. The effect of air conditioner to the cooling performance, e.g., radiator inlet temperature, of the radiator and engine system was examined. This study could make standards of design of radiator capacity using heat rejection with respect to the mass flow rate of cooling air. This study is intended to predict the performance of each component at design step or to simulate the system when specification of the component is modified, and to analyze the performance of the total vehicle engine cooling system.

Turning of Hardened Materials Using the Air-oil Cooling System (에어-오일 냉각방식에 의한 고경도재료의 선삭)

  • Chung, Bo Gu;Ko, Tae Jo;Kim, Hee Sool
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.8
    • /
    • pp.73-81
    • /
    • 1997
  • The hard turning process defined as a single point turning of materials harder than $H_{R}$C 58 differs from conventional turning because of hardness of the work materials and cutting toos needed in the process. In hard turning, tool life is very short, of the order of a few minutes, during which the cutting tool is subjected to the extremes of stress and temperature. In this regard, it is well known that CBN tool is proper for this process in spite of expensive cost. In this research, we studied the feasibility of the use of the low cost cutting tool such as a aTiN coated tool. To this end, a new cooling system was designed with an air-oil method for reducing tool temperature, which is based on the principle of air vortex flow. That is, the outlet temperature of the air becomes aver 20 .deg. C lower than atmosphere temperature by entering pressurized air of 5kgf/c $m^{2}$ into the inlet. This cooled air ejected to the top of the cutting tool lowered tool temperature, which reduced the wear of a TiN coated tool by the 30% of CBN tool life with respect to the same cutting length.h.

  • PDF

Nondestructive Characterization of Degradation of EPDM Rubber for Automotive Radiator Hoses (자동차 냉각기 호스용 EPDM고무의 노화에 대한 비파괴 특성평가)

  • Kwak, Seung-Bum;Choi, Nak-Sam;Choi, Youn-Joung;Shin, Sei-Moon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.5
    • /
    • pp.368-376
    • /
    • 2005
  • Coolant rubber hoses for automobile radiators can be degraded and thus failed due to the influence of contacting stresses of air and coolant liquid under thermal and mechanical loadings. In this study, for EPDM(ethylene-propylene diene monomer) rubber conventionally used as a radiator hose material the aging behaviors of the skin part due to thermo-oxidative and electro-chemical stresses were nondestructively evaluated. Through the thermo-oxidative aging test, it was shown that the surface hardness IRHD(International Rubber Hardness Degrees) of the rubber increased with a considerable reduction of failure strain. On account of the penetration of coolant liquid into the skin part the weight of rubber specimens degraded by electro-chemical degradation(ECD) test increased, whereas their. failure strain and IRHD hardness decreased largely. The penetration of coolant liquid seemed to induce some changes in inner structure and micro hardness distribution of the rubbers. Consequently, EPDM rubbers degraded by thermo-oxidative aging and ECD could be characterized nondestructively by micro-hardness and chemical structure analysis methods.

A Study on Cooling Performance of Aluminium Heat Sink with Pulsating Heat Pipe (PHP를 결합한 알루미늄 히트싱크의 냉각성능에 관한 연구)

  • Kim, Jong-Soo;Ha, Soo-Jung;Kwon, Yong-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1016-1021
    • /
    • 2011
  • The enhancement for cooling performance of heat sink is surely necessary to guarantee the performance of electronic products. So in this paper, the cooling performances of the aluminum heat sink with pulsating heat pipe(PHP) were investigated experimentally and numerically. The pulsating heat pipe was used as a heat spreader. Working fluid of PHP was R-22. Heat inputs were 30W, 60W, 80W and 100W, respectively. Heat sink was tested for forced convection conditions with air velocity of 1 ~ 4m/s. And CFD simulations were conducted for two different heat sinks. The results showed that the cooling performance of heat sink with pulsating heat pipe was higher than that of conventional heat sink. Therefore, the pulsating heat pipe can be a good tool to improve cooling performance of heat sink.

A Study on Fluid Flow and Heat Transfer of a Corrugated Structure for Crossflow Reduction of Impingement Jet (충돌제트에서의 횡방향 유동 감소를 위한 파형 구조의 유동 및 열전달에 관한 연구)

  • Hwang, Byeong Jo;Kim, Seon Ho;Joo, Won Gu;Cho, Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.5
    • /
    • pp.329-339
    • /
    • 2017
  • Impingement jets have been applied in a wide variety of fields as they provide significantly high heat transfer on the impingement-jet stagnation zone. However, the crossflow in an impingement chamber developed by spent wall jets can disrupt and deflect the downstream jets in the array, leading to a decrease in the cooling performance of an array of impingement jets. A numerical analysis is made of the fluid flow and heat transfer characteristics in a corrugated structure that traps the spent air in the corrugations between impingement jets and reduces crossflow effects on downstream jets. All computations are performed by considering a three-dimensional, steady, and incompressible flow by using the ANSYS-CFX 15.0 code. The effects of the configuration parameters of the corrugated structure on crossflow reduction of the array of impingement jets are presented and discussed.

A Study on Cooling Effect and Power Control of a Mini Ozonizer (소형 오존발생장치의 전력제어와 냉각효과에 관한 연구)

  • Woo, Sung-Hoon;Park, Seung-Cho;Yoon, Sung-Yoon;Park, Jee-Ho;Woo, Jung-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.97-103
    • /
    • 2006
  • In this paper, a control method of a mini ozone generator is proposed, and also a cooling technique is described which is cooling down the flowing air gap into a silent discharger to $2^{\circ}C$ to generate ozone of high density and diffusing power. As the digital control system for this method, a double feedback loop is designed which detects the voltage and current of equivalent capacitor of the discharger and compensates for the poor power waveform caused by the noise at high discharging frequency. During the plant modeling of this system, computing time factor is considered as a unique parameter of the power system to improve the transient responses with regard to fluctuating load and to replenish the computing time delay of the controller. Through the experiment, sinusoidal input current for discharger can be acquired and all the effectiveness of this accurate control system over unstable ozone discharger are proved.