• Title/Summary/Keyword: 공기공급

Search Result 740, Processing Time 0.032 seconds

Experimental Study on Combustion Performances with Variations in Main Air-ratio and Dilution hole-pattern (주연소 영역 공기배분 및 희석공기공 배치에 따른 연소 성능 변화 연구)

  • Kim, Minkuk;Kim, Hanseok;Jung, Seungchai;Park, Heeho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.254-257
    • /
    • 2017
  • As a part of the development of aircraft gas turbines, combustion performance tests have been conducted in the single combustor sector. The effects of change in the amount of air supplied to the main combustion zone to the performance of the combustor, such as a pollutant emission, a liner temperature distribution and an exit temperature patterns, were studied. Emissions of CO and NOx increased with the main air-ratio and exit temperature pattern was improved. When changing the pattern of the dilution holes, it was shown that the temperature patterns on the exit plane of the combustor and the surface of liner changed depending on the main flame structure and mixing with diluent air. These observations will be applied to combustor liner designs to improve combustor durability and emissions reduction performance.

  • PDF

A Study on Thermal Management of Stack Supply Gas of Solid Oxide Fuel Cell System for Ship Applications (선박 전원용 고체산화물형 연료전지(SOFC) 시스템의 스택 공급 가스의 열관리 문제에 관한 연구)

  • Park, Sang-Kyun;Kim, Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.765-772
    • /
    • 2011
  • In this research, the fuel cell system model capable of generating codes in real time was developed to construct of a HIL (Hardware-In-the-Loop) for a SOFC-powered ship. Moreover, the effects of the distribution of the exhaust gas flow rates in a stack, the flow rates of fuels and temperature of air supplied on the temperature characteristics of fuels supplied to the cathode and the anode, the output power of the stack and system efficiency are examined to minimize the temperature difference between fuels supplied to the stack used in a 500kW SOFC system using methane as a fuel. As a result, the temperatures of fuels supplied to the cathode and the anode maintain at 830K when the opening factor of three-way valve located at outlet of turbine is 0.839. Also the process for optimization of methane flow rate considering the fuel cell stack and system efficiency is required to increase the temperatures of fuels supplied to the stack.

Changes in Characteristics of Semi-cured Pig Manure Liquid Fertilizer according to the Storage Duration and Aeration (반부숙상태 돈분뇨 액비의 저장기간 및 폭기여부에 따른 특성 변화)

  • Jeong, Kwang-Hwa;Park, Hoe-Man;Lee, Dong-Jun;Kim, Jung-Kon;Kim, Hyunjong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.4
    • /
    • pp.109-122
    • /
    • 2022
  • Currently, most of the pig manure generated from pig farms in Korea is in the form of a slurry with a moisture content of about 97%. Pig manure slurry is a mixture of pig manure and cleaning water in the pig house. In this study, changes in properties of pig manure liquid fertilizer according to whether air was supplied or not and with the passage of storage period were analyzed for 120 days. During the experimental period, the degree of maturity of the pig manure liquid fertilizer was higher in the experimental closed batch reactors supplied with air than in the same type reactors not supplied with air. As the liquid fertilizer storage period elapsed, there was a tendency that liquid fertilizer was converted to a state of complete maturity. In the batch reactor in which air was supplied, the moisture content of pig manure slurry, which had a moisture content of 97.90%, was reduced to 96.82% at the end of the experiment. On the other hand, the moisture content in the reactor without air was reduced to 97.33%. The pH of the liquid fertilizer, which was 8.82 at the start of the experiment, changed to 7.57 in the reactor with air supplied and 8.75 in the reactor without air at the completion of the experiment. The nitrogen content in the liquid fertilizer was 0.198 mg/L on average at the start of the experiment and it was lowered to 0.076 mg/L in the air supplied reactor at the end of the experiment. On the other hand, the nitrogen content of the liquid fertilizer was lowered to 0.121 mg/L in the reactor to which air was not supplied. The phosphoric acid (P2O5) concentration in the liquid decreased higher in the liquid fertilizer filled in the reactor without air than the liquid fertilizer filled in the reactor with air supplied as the storage period elapsed. Considering the experimental results, it is considered that the quality of pig manure liquid fertilizer is improved when air is supplied to pig manure slurry and the storage period of pig manure slurry is longer.

Effect of aeration on the physicochemical characteristics of livestock feces compost during composting period (퇴비화과정 중 공기공급 여부가 가축분뇨 퇴비의 물리화학적 특성에 미치는 영향)

  • Jeong, Kwang-Hwa;Kang, Ho;Kim, Tai-ll;Park, Chi-Ho;Yang, Chang-Buem
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.4
    • /
    • pp.57-65
    • /
    • 2003
  • Livestock farming is one of several industries that have faced criticism because of its impact on the water quality, soil contamination and air pollution. The livestock feces can cause some environmental problems. The best way to treat the feces is to recycle the manure as an organic fertilizer after fermentation or composting. This study was carried out to investigate the characteristics of composting of manure in several composting conditions. The variations of physicochemical characteristics of each compost piles containing different level of air volume were analyzed throughout the composting period. In this study, pigs manure compost piles mixed with saw dust were composted in 110L of laboratory scale plastic vessels and $1.5m^3$ of small cubic wooden composting vessels for 60days. The compost piles were ventilated continuously with air pump throughout the composting duration. The air volume ventilated into the piles was regulated by chock valve attached to the inlet pipe. The ventilation level was adjusted by 20, 50, 100, 150 and $200L/m^3/mim$, respectively. The highest temperature of the compost increased to $72^{\circ}C$ during composting period. After 20days from beginning of fermentation, concentrations of $H_2S$, $CH_3SH$, DMS and DMDS generated from compost piles were 29, 16, 6 and 5ppb in blow in state compost pile, conversely, in blow out state compost pile, the parameters were 32, 24, 15 and 14ppb, respectively.

  • PDF

Experimental Study of Freezing and Thawing Characteristics of Concrete Influenced by Air Content and Water Cement Ratio. (공기량 및 물-시멘트비에 따른 콘크리트의 동결융해 특성에 관한 실험적 연구)

  • 오병환;한승환;이용호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.91-96
    • /
    • 1993
  • 본 연구의 목적은 콘크리트의 열화손상을 주는 요인 중 특히 수분의 공급이 충분한 동결융해작용에 대한 영향인자에 대한 실험적 연구이다. 콘크리트의 열화에 영향을 주는 여러 영향인자 중에서 주로 공기량 및 물-시멘트비를 다루었다.

  • PDF

쾌적한 실내환경을 위한 클러스터이온 발생장치 기술

  • Ji, Yong-Jun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.39 no.2
    • /
    • pp.17-23
    • /
    • 2010
  • 자동차 내부의 공기정화를 위하여 설치되는 공기청정기술에서 새로운 방식의 클러스터이온 발생장치에 의한 클러스터 음 양이온 공급, 제균, 항균 및 악취제거로 쾌적한 실내환경을 제공할 수 있는 기술에 대하여 소개하고자 한다.

  • PDF

Mass Production of Resting Eggs by the Freshwater Rotifer, Brachionus calyciflorus Pallas with Exchange of Culture Water and Supplemental Aeration (환수 및 공기공급에 따른 담수산 rotifer, Brachionus calyciflorus의 내구란 대량생산)

  • Kwon, O-Nam;Park, Heum-Gi
    • Journal of Aquaculture
    • /
    • v.18 no.2
    • /
    • pp.115-121
    • /
    • 2005
  • This study was performed to investigate the formation and mass production of resting eggs by freshwater rotifer, Brachionus calyciflorus as influenced by different aeration supplements and exchange intervals of culture water in 15-L culture vessels and 500 L culture tanks. The maximum densities and mixis rates of the rotifers were not different between experimental group exposed to air or oxygen supplements. However, the fertilization rate and formation of resting eggs of the rotifers in the air-supplemented group were significantly higher than those in the oxygen supplemented group. In the experiment concerning exchange interval of culture water, the maximum density of the rotifers and formation of resting eggs in the batch culture were significantly higher than those in the semi-continuous culture with exchange of water every day. The formation of resting eggs per Chlorella dry weight was highest in the semi-continuous culture with exchange of water every day. The resting eggs of rotifers were produced at a density of $51.8{\sim}57.9{\times}10^6$ eggs in 500-L culture tanks. In this study, the batch culture with air is an effective method for mass production of resting eggs by the freshwater rotifer, B. calyciflorus, and the efficiency of mass production of resting eggs by this rotifer was similar to that of the seawater rotifers, B. plicatilis and B. rotundiformis.

A Study on the Air Ventilation System of Operation Room for the Prevention of Hospital Infection (수술중 감염방지를 위한 공조시스템의 개선방안에 대한 연구)

  • Kim Chun-Sook;Kwon Soonjung;Joo Youngcheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.6
    • /
    • pp.552-557
    • /
    • 2004
  • The air ventilation system of operation rooms has been studied for the prevention of cross infection during the operation. Operation rooms and air ventilation systems of three University hospitals are investigated. The distribution of microbe is measured by cultivating air samples in the operation room. A two-dimensional model for the cross-section of an operation room is developed for the CFD analysis. The characteristics of air flow in operation room are calculated by using a CFD program. The current air ventilation system of an old hospital does not deliver the clean air to the operation area efficiently. A new air ventilation method which improves air venting with little increase of the cost of equipment is suggested.

  • PDF