• Title/Summary/Keyword: 공급 밸브

Search Result 229, Processing Time 0.03 seconds

Solenoid Valve DCC-PWM Control for Diesel Engines Fuel Pump (디젤엔진 연료펌프의 솔레노이드 밸브 DCC-PWM 제어)

  • 신우석;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.85-91
    • /
    • 1998
  • This paper describes an study electric injection system for diesel engines. It is needed effective fuel injection which controls the solenoid valve of fuel pump. To solve this, this paper proposes DCC-PWM method which can realize fast reply and low holding current for solenoid valve on/off. For the proposed design method, simulation tools of ACSL are used to analyze the system. And the single-chip microcomputer is used to reduce the size of controller and to improve flexibility. And the systems validity can be verified through the experimental results.

A Study on Stability Improvement of Fuel Metering Unit for Air Breathing Engine (공기흡입식 추진기관용 연료조절밸브 시스템 안정성 향상에 관한 연구)

  • 이도윤;박종승;최현영;구자용
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.9
    • /
    • pp.76-81
    • /
    • 2006
  • This paper deals with a fuel metering unit (referred to as FMU) for air breathing engine. The proposed FMU consists of a constant pressure drop valve and a metering valve, both of which are controlled by servovalve. Linear analysis derived from a nonlinear mathematical model of FMU is carried out to find major parameters on the system performance. Numerical results using established model of FMU were in good agreement with the experimental results. It is also shown that the system stability is improved by reducing the constant pressure drop at metering valve and applying the triangular orifice to constant-pressure-drop valve through the simulation and experiments.

Techniques for Searching Isolated Pipe Sections in Water Pipe Networks (상수도 관망의 고립구역 탐색 기법)

  • Park, Su wan;Kim, Ki Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.131-131
    • /
    • 2017
  • 상수관의 노후화로 인해 상수관망의 안정성 확보와 지속적인 용수공급에 대한 신뢰성을 증대시키는 것이 중요해지고 있다. 용수공급시스템을 구성하는 상수관의 파괴가 빈번하게 발생하며, 관 파괴 시에 수리, 교체를 위해서 관망의 일부분은 차폐가 되어 해당 지역의 용수 수요자는 수리, 교체작업이 끝날 때까지 단수가 불가피하다. 이런 불편함과 손실을 최소화하기 위한 방법을 찾는 것은 상수관망의 유지관리에서 중요한 문제이다. 상수관망의 부분적 격리는 오염물에 의한 상수관망의 오염, 테러로 인한 독극물의 유입 시 물질의 확산 방지, 상수관망을 이루는 각종 구조물의 고장수리 및 유지 보수 작업 등의 상황을 위해 필수적이다. 상수관망의 부분적 격리를 분석하기 위해서는 '고립구역'이라는 개념이 필요하다. 관 파괴시 밸브가 닫히면서 해당 관과 연결된 관들 또한 함께 격리되는 부분을 '고립구역'으로 정의한다. 관이 두 개의 밸브를 양 끝에 가지고 있는 경우와 독립적인 절점 또한 하나의 '고립구역'으로 정의할 수 있다. 본 연구에서는 이러한 '고립구역'을 실제 상수관망에서 탐색해서 정의할 수 있는 알고리즘을 제시하였다. 뿐만아니라 상수관 파괴 시 복구를 위해 파괴된 관을 포함한 고립구역이 차폐될 경우, 세그먼트내의 관들은 수원지로부터의 물공급에 차질이 생길 수 있다. 특정 관들의 고립구역이 수원지로부터 유일한 용수공급경로일 경우 고립구역의 차폐로 인해 해당 관들의 용수공급도 끊어지게 되는데 이러한 영역을 '비의도적 고립구간'이라 한다. 본 연구에서는 이러한 '비의도적 고립구간'을 실제 상수관망에서 탐색하여 정의할 수 있는 알고리즘을 제시하였다.

  • PDF

A development of auto shape inspection system for automotive valve-seal (자동차용 Valve-seal의 자동검사 장치 개발)

  • Lee, Kyu-Hun;Kim, Yong;Lee, Eun-Young;Cho, Kyu-Man;Bae, Jin-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.314-315
    • /
    • 2007
  • 자동차용 부품인 밸브씰 비전 검사 시스템을 개발하였다. 구성부품은 8 대의 독립형 CCD 카메라, 검사를 위해 밸브씰을 공급해 주는 기구장치 및 검사 모니터링 시스템으로 구성되었다. 밸브씰의 대표적인 불량 유형 1가지에 대한 영상처리 알고리즘을 제안하고, 알고리즘의 효율성은 실험을 통하여 확인하였다.

  • PDF

Development of Prototype Fill/Drain Valve for Supply of Satellite Propellant (인공위성 추진제 공급용 Fill/Drain 밸브 시제품 개발)

  • Kim, Su-Kyum;Yu, Myoung-Jong;Lee, Kyun-Ho;Choi, Joon-Min;Jang, Ki-Won
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.3
    • /
    • pp.26-31
    • /
    • 2006
  • Through the KOMPSAT program, Koreanization of thruster have been carried out successfully, but there are still many difficulties in Koreanization of most core parts of propulsion system. Because the development of core parts is essential to participate in the advanced nations, KARI has carried out development of Fill/Drain valve for propellant/pressurant supply of satellite, which has high possibilities to be koreanized, with Hanwha Corp.. This paper summarizes overall processes of development including design, manufacturing and test, and finally 4 sets of modules were successfully made. Also the satisfaction of performance requirements are verified through performance tests.

Analysis of Dynamic Characteristics and Performances of Vent-Relief Valve (산화제 벤트/릴리프밸브의 동특성 해석 및 작동성능분석)

  • Jang, Je-Sun;Koh, Hyeon-Seok;Han, Sang-Yeop;Lee, Kyung-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.741-747
    • /
    • 2010
  • Vent-relief valve performed as a safety-valve combination for liquid propellant feeding system of space launch vehicle, which can vent the vaporized oxygen vapor during both filling cryogenic oxidizer into tank and flight. We have designed vent-relief model by using the AMESim code to predict dynamic characteristics and simulate pneumatic behavior of valve. To validate valve model we have compared by opening time in vent model, and opening/closing pressure by mathematical methods and improved the accuracy through numerical flow analysis by using FLUENT code. In this study, we had verified design parameters and analyzed operating performances. We can use these analysis results to precedent development study on propellant feeding system of Korea Space Launch Vehicle.

  • PDF

기기냉각수 최저온도와 정지냉각계통 유량조절밸브 개도에 관한 설계분석

  • 김도현;이중섭;오종필;오광석
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.444-449
    • /
    • 1995
  • 한국형 표준 원자력발전소의 정지냉각운전시 최대냉각율은 75$^{\circ}$F/hr(41.7$^{\circ}C$/hr)로 기술사양서에 규정되어 있다. 정지냉각운전 냉각율에 가장 큰 영향을 미치는 2가지 중요한 변수는 정지냉각계통 열교환기를 지나는 원자로냉각재 유량과 기기냉각수의 온도다. 이중 열교환기를 지나는 원자로냉각재 유량은 butterfly형 정지냉각계통 유량조절밸브의 개도에 의하여 조절되는데 개도에 따른 throttle 능력이 중요한 인자다. 또 기기냉각수의 온도는 해수온도의 변화에 따라 편차가 발생하므로 유량조절밸브의 개도와 기기냉각수 온도의 상관관계에 따라 냉각능력이 달라진다. 본 논문에서는 현 울진 3&4호기 정지냉각계통 열 교환기 및 조절밸브 둥의 설비를 기준으로 기술사양서 상의 냉각율 75$^{\circ}$F/hr(41.7$^{\circ}C$/hr) 유지가 가능한 최저 기기냉각수의 온도를 찾아보았고, 아울러 기기냉각수의 온도와 조절밸브의 개도 사이의 관계를 조사하였다. 그 결과 현재의 울진 3&4호기 조절밸브를 최저개도로 조절할 때 약 57$^{\circ}$F(13.9$^{\circ}C$)의 기기냉각수가 공급되어도 냉각율 제한치를 넘지 않는 것으로 분석되었다. 한편, 최저조절가능 유량이 약 2000 gpm(7570 l/min)일 경우에는 낮은 기기냉각수가 공급될 경우 최대냉각율을 초과하므로 한 train을 정지시키고 한 train만으로 운전할 것을 고려하여야 할 것으로 보인다. 이 경우 최저 약 56.5$^{\circ}$F(13.6$^{\circ}C$)의 기기냉각수가 공급되어야 한다. 본 논문의 분석결과는 향후 기기설계사양서나 운전지침서 등에 반영되어 실제 발전소 설계 및 운전절차 수립에 기여할 수 있을 것으로 생각된다.공감대의 형성이 요구된다. 질적 측면에서는 공원 녹지의 기능성의 회복이라는 측면과 시대에 부합되는 새로운 기능 및 가치의 부여가 필요하며, 이를 위해서는 공원의 매력, 공원의 시설기능 증진, 녹지의 질의 향상 및 녹지 가치의 증진에 대한 다양한 시책이 요구된다. 구성적 측면에서는 공원녹지의 개별적 존재보다는 공원 녹지를 상호간 유기적인 계통을 확보하여 공원 녹지의 네트워크를 형성하여 도시 속의 산재된 고립된 섬으로서의 공원 녹지가 아닌 시민생활에 늘 가까이 있는 생활 속의 공원녹지로 재편되어야 한다. 이러한 정책의 의제는 양적 측면에서 보전(CONSERVATION)과 창출(CREATION), 질적 측면에서 쇄신(RENOVATION)과 복구(RESTORATION), 그리고 구성적 측면에서 공원 녹지의 연결(CONNECTION)과 시민 참여에 의한 운동(MOVEMENT)이라는 정책 개념의 구현을 통해 가능하다. 이러한 정책 개념과 의제를 가지고 서울시 공원 녹지 정책을 구체화시키기 위해서 푸르름의 새로운 탄생이라는 기치 아래 풍요로운 서울, 사랑 받는 공원, 생활 속의 녹지의 3대 목표, 공원 녹지의 보전, 잠재 공원 녹지의 창출, 공원의 활성화, 녹지의 복구, 경관 보전 및 복구, 공원 녹지의 네트워크, 도시 녹화의 7대 과제를 설정하고 미시설 공원 녹지 집행, 개발 사업시 공원 녹지의 확보, 환경 녹지의 총량 보호 관리, 도시 소공원 개발, 역사 문화 공원 조성, 하천 공간 복원, 공원 시설 기능 개선, 이용 프로그램 개발, 공원 관리 개선, 환경 피해 녹지의 회복, 도시 환경 림 조성, 녹지 기능 증진, 도시 자연 경관 보전, 공원 녹지체계 구성, 공원 녹지 공급 균형, 주변 환경 녹화, 가로 녹화의 17개 시책을 제안하였다. 이러한 정책사업의 원활한 추진을 위해서는 기존의 관주도의 일방적인 공원 녹지 행정이 아닌 시민의 참여를 통한 시민이 함께 하는 정 책 사업의 추진이 요구되며, 특히 민간 부문의

  • PDF

A Study on the development of gas metering valve system (가스 계량 밸브 시스템의 개발에 관한 연구)

  • Choi, Young-Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.7 no.4
    • /
    • pp.200-204
    • /
    • 2014
  • LPG is used in the home would have to depend on the provider, because there is no method for measuring the capacitance. In addition, by measuring the gas capacities can not be known because of the LPG gas replacement time and requires an alarm for replacement. In this study, and that the gas capacities to the trusted user and the supplier, in order to know when it is time to change to LPG gas by applying a Hall effect sensor developed a gas capacities measurement the valve system.

The change of hydraulic charictar in pipenetwork be followed by the opening and closing valve. (상수도 관망내 밸브 개폐에 따른 수리적 특성 변화)

  • Rhee Kyoung Hoon;Oh Chang Ju;Kim Tae Kyoung;Kim Ji Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.981-985
    • /
    • 2005
  • 상수도 관망은 상수도 운용시스템에서 가장 중요한 부분이다. 그러므로 항상 수요자의 필요에 부응하는 충분한 수량과 좋은 수질로 공급할 수 있도록 적정한 압력 유지와 수량 확보가 되도록 유지 관리 되어야 한다. 이를 위해서는 상수도 관망의 합리적인 해석과 최적의 설계를 통해 수요자가 필요로 하는 양질의 물을 원활히 공급하고 재원의 낭비를 줄여야 한다. 그러나 우리나라의 많은 대도시들의 경우처럼 특히 상수도 시설이 거대해 지고 급수구역이 광범위하며 복잡한 배수시설을 가지고 있는 지역에 있어서는 모든 현상을 정확하게 파악하고 유지관리하기가 매우 어렵게 되므로 운영관리상 많은 문제점이 발생하게 된다. 이러한 문제점에 보다 효율적으로 대처하기 위해서는 가장 기본적으로 현재의 상수도 시설에 대한 수리적 상태를 파악하여야 한다. 따라서 본 논문에서는 대도시 상수도 시설의 효율적 운영 및 확장에 기본이 되는 현재의 상수도 시설에 대한 시설현황, 운영, 수리상태를 파악 하고, 밸브의 개폐에 따른 수리학적 특성 변화를 제시하고자 하였다. 관망 해석에 필요한 입력 자료는 실제 운영되고 있는 광주광역시의 상수도 급배수 관망 시설을 대상으로 산출 하였고 관망해석 프로그램인 Pipenet 98을 이용하여 시뮬레이션을 실시하였다. 본 논문에서 대상 구역에 대해 수리적 특성 변화를 모의한 결과 상수 관로내의 밸브 개폐도를 $100\%$ 유지시켰을 때 평균 수압은 $4.4kg/cm^2$으로 나타났으며 밸브 개폐도 $80\%$일 때의 평균 수압 $4.7kg/cm^2$, 밸브 개폐도 $60\%$일 때의 평균 수압은 $4.69kg/cm^2$으로 나타났다. 밸브 개폐도가 $100\%$일 때가 밸브를 $60\%$$80\%$ 개폐시켰을 때보다 $0.3kg/cm^2,\;0.29kg/cm^2$ 낮게 나타나 밸브를 전체 개방 했을 때 관로내의 수압이 상수설계기준에 적합한 수압을 유지함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.

  • PDF