• Title/Summary/Keyword: 공공기관건물

Search Result 42, Processing Time 0.03 seconds

A Study on Uniform of ISDN/PSTN Subscriber Telephone Number for the Service Improvement (서비스개선을 위한 ISDN/PSTN 가입자번호 통일화에 관한 연구)

  • 박광채
    • Information and Communications Magazine
    • /
    • v.11 no.2
    • /
    • pp.113-122
    • /
    • 1994
  • In this paper, We analyze and inspect the problem of our country PSTN subscriber telephone number and suggest the ISDN/PSTN subsciber numbering plan in the future. Expecially, when you eastablish plan to change present telephone number system to ISDN telephone number system, public goverment and public office which has many calls have to be given a same number that many people want and being easy rememberance thoughout the country. Therefore we think that it is saving hours and reduce lost calls. As concrete action of convert plan it must be made consistent numbering plan when the numbering reorganization is carried out in Korea before T-time. If a partial is not carried out, it should be given when the telephone number is newly-organized or the big buliding and goverment and public office eastablich RSS individually. At that time chaos will be minimized.

  • PDF

A Study on Energy Reduction of Passive Factor Apply for the Improvement of Energy Performance in Public Building (공공기관 건물의 에너지 성능개선을 위한 패시브 요소 적용의 에너지 절감율 분석 연구)

  • Son, Ji-Hoon;Kim, Sam-Uel
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.196-201
    • /
    • 2011
  • The energy used in Korea is strongly dependent on that produced by foreign countries. Accordingly, saving energy is more important than ever, because of the rise of international oil prices and depletion of oil resources. The development of energy efficient buildings is required especially for public buildings in Korea. In this study, the energy use of public buildings is identify. Then, the analysis of energy usage through regional offices in Busan City offers energy performance for public buildings.

  • PDF

군 유휴공간 태양광발전 경제성 연구

  • Jang, Tae-Mun;Kim, Gyeong-Nam
    • Bulletin of the Korea Photovoltaic Society
    • /
    • v.4 no.2
    • /
    • pp.62-70
    • /
    • 2018
  • 대한민국 정부는 '재생에너지 3020 계획'에 따라 2030년까지 재생에너지 발전 비중을 20%까지 확대하겠다는 방침을 세웠다. 목표 달성을 위한 태양광발전은 30.8GW을 신규설비로 확보해야 하지만 신재생에너지를 설치할 수 있는 공간은 한정되어 있어 추가적인 공간이 문제가 된다. $297km^2$의 건물 부지를 소관하고 있는 군(軍)은 공공기관 중 가장 넓은 부지를 보유한 단일 기관이다. 이러한 군 유휴공간을 활용한 민간투자방식의 태양광 발전사업 경제적 타당성을 연구하였다. 본 연구에서는 경제적 효과를 RETScreen을 통해 분석하였고, 그 결과 내부수익률(IRR) 10.7%로 경제적 타당성이 입증되어 민간투자의 사업성을 확인하였다. SWOT분석 결과에 따르면 군 태양광 BOT사업은 전력 모니터링 및 유지보수 등 사업 전 과정에서 보안 요소가 발생하지만, 강한 규제의 산지 및 임야의 대안으로 표준화된 군사시설이, 한 번의 설계로, 유휴공간에 대량 설치가 가능한, 모듈화의 이점을 가지고 있었다.

  • PDF

A study on the selection of candidates for public bases according to the spatial distribution characteristics Automated External Defibrillator in Daegu City (대구시 자동심장충격기 공간분포 특성에 따른 공공 거점후보지 선정 연구)

  • Beak, Seong Ryul;Kim, Jun Hyun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.599-610
    • /
    • 2020
  • The AED (Automated External Defibrillator) is not evaluated for spatial accuracy and temporal availability even if it is located within a building or a specific area that needed necessary to partition by spatial analysis and location allocation analysis. As a result of the analysis, the spatial analysis was performed using the existing public data of AED with applied the GIS location analysis method. A public institution (119 safety center, police box) was selected as a candidate for a public AED base that can operate 24 hours a day, 365 days a year according to the characteristics of each residential area. In addition, Thiessen Polygons were created for each candidate site and divided by regions. In the analysis of the service was analyzed regional in terms of accessibility to emergency medical services in consideration of the characteristics of AED, that emergency vehicles could arrive within 4 minutes of the time required for emergency medical treatment in most areas of the study area, but it did not areas outside of the city center. As a result, It was found that the operation of the AED base service center centered on vehicles of public institutions is effective for responding to AED patients at night and weekend hours. 19 Safety Center under and police box the jurisdiction of Daegu City to establish an AED service center for public institutions, location-based distance, attribute analysis, and minimization of overlapping areas that the method of using a vehicle appeared more efficient than using the existing walking type AED.

The analysis on the operation condition and premium proportion for estimating the appropriate capacity of Cooling Equipment - Public office- (열원장비의 적정용량산정을 위한 장비가동현황 및 할증률 분석 - 공공업무시설 -)

  • Shin, Mu-Kyung;Park, Sung-Hun;Park, Eun-Ha;Jang, Jong-Woon;Lee, Ji-Won;Kim, Se-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.506-511
    • /
    • 2006
  • To today with the acceleration due to the preference actual condition of high-class energy national income level it is together improving. It follows hereupon and it is convenient and the neat heat source is increasing a tendency where it is. It investigates the government offices building in commerce portion from the research which it sees and from the draft it analyzes a coat dosage. And comparison it analyzes the movable present condition of thread use dosage and the freezer. It presents the improvement direction against enemy conditions heat source equipment selecting. Also, currently it produces the dosage of heat source equipment and application it tries. The result, the various safety rate and the premium rate which it uses universally are considered above thread using. The reappraisal for enemy conditions heat source equipment selecting which it follows hereupon is necessary.

  • PDF

Evaluation of Energy Self-Sufficiency Rate through Case Analysis of Building Energy Efficiency Rating in Educational Facilities (교육시설의 건축물에너지효율등급 사례분석을 통한 에너지자립률 평가)

  • Lee, Hyun-Seung;Kim, Ji-Hyeon;Lee, Seung-Min;Meang, Joon-Ho;Shin, U-Cheul
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.18 no.4
    • /
    • pp.58-65
    • /
    • 2019
  • Under the regulation of rational energy use in public institutions, it has been mandatory for educational facilities to meet the first grade or higher since 2014. Also the regulation has forced educational facilities as public institutions to use renewable energy since September 2008. Educational facilities are required to be qualified as zero-energy buildings from 2020 under the revision of the Green Building Act. In this study, we identified the current status of the building energy efficiency rating system and the renewable energy system installation for 316 educational facilities that were accredited as "building energy efficiency rating system" from February 2015 to March 2019. Also we analyzed the energy self-sufficiency rate based on energy requirements and renewable energy output. Of the 316 facilities, 12 had 1++ and 293 had 1++ for the "Building Energy Efficiency Rating System". Among the 12 facilities which had 1+++, 11 recorded ZEB level 5 or higher, and 28 out of the 293 facilities(11%) which got received 1++ had ZEB level 5. Thus, it is impossible to implement the ZEB certification system for educational facilities under the present conditions. Expanding the ratio of 1+++ and investing in renewable energy systems should be preceded.

Analysis of the Building Energy Efficiency Rating Certified for Public Office Buildings (공공기관 업무용 건물의 건축물에너지효율등급 인증 현황 분석)

  • Lee, Han-Sol;Kim, Seo-Hun;Kim, Jonghun;Kim, Jun-Tae;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.75-82
    • /
    • 2015
  • Purpose: The first grade of Korea's Building Energy Efficiency Rating System(BEERS) is required for new government office buildings as a mandatory measure to reduce greenhouse gas emission. However, there is no specific criteria about performance that which level should apply to energy-saving design element for obtaining Building Energy Efficiency Rating 1st grade. Therefore, Certification status should be analyzed firstly, about the office building which is certificated. Certification analysis for office buildings acquired certification therefore should be done first. Method: In this study, Certification status(Office buildings acquired Building Energy Efficiency Rating Certification)was analyzed by classified year, region, specific scale etc. And we analyzed statistically by eliciting an average value of each element influencing to the amount of energy. Result: Energy demands were gradually decreased due to revision of thermal insulation standards for enhanced u-value. Energy consumptions were different from the kind of equipment and yearly trends applied depending on the size of the building. Total primary energy consumptions were influenced by heat source types and the primary energy scale factors.

A Study on Design Tendencies in Office Buildings of Public Institutions after Reinforcement of the Building Energy Performance Criteria in Korea (건물에너지성능기준 강화 이후 국내공공기관 업무용 건축물의 디자인경향)

  • Lee, Ah-Young
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.139-149
    • /
    • 2011
  • This study focuses on design tendencies in office buildings of public institutions after tightening up Korea's building energy performance criteria. Important office design criteria and recommendations pay attention to the issues such as building orientation, greening buildings, building form, space and envelop by intensifying building energy performance related laws, government guidelines and evaluation systems. The design tendencies explored in this research are as follows. Office buildings mainly face south and have various types of indoor and roof green spaces not for ecological reasons but for the rest. Building depth becomes thinner and atria are inserted into office buildings to improve daylighting and natural ventilation. Building cores are located on north or west and east sides acting as buffer spaces to reduce heat loss and to block solar radiation. Office building envelop design includes various creative ideas to control or utilize solar energy as like three dimensional or double structured skin and window size variation to cope with the intensity of solar radiation. Further, solar energy generation systems are integrated with building component such as roofs, sun screens and windows. This study demonstrates that government's reinforcement of the building energy performance criteria drives the change in design methods and approach.

The Research on Scheme to Prevent Inundation at the Underground Space (지하공간의 침수방지대책에 관한 연구)

  • Ahn, Sang Jin;Seo, Byung Ha;Choi, Gye Woon;Park, Keun Hong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.883-887
    • /
    • 2004
  • 현재 전국적으로 $\blacktriangle$ 전기, 가스, 상수도, 하수도, 열수송관 등을 공동 수용하는 '지하공동구'가 14개 도시 30개소에 160.4km $\blacktriangle$ 보행공간으로 병용되는 '지하도로'가 23개도시 118개소에 63만 $m^2$ $\blacktriangle$ 지하도로내 설치된 지하점포가 1만1천798개소 23만$m^2$이 있다. 이와 같이 현대 도시내에서 지상공간의 과밀도 개발로 인하여 지하공간의 수요가 증대되어 지하공간 구조물이 많이 설치되고 있는 반면, 지하상가, 지하천 등과 같은 지하공간 시설에서 발생할 수 있는 침수피해 대책이 미흡한 실정이다. 본 연구에서는 과거 지하공간의 침수피해 실태를 조사하고 그 사례에서 원인을 분석하여 기술적 해결책을 도출해 내며, 침수방지를 위한 대책으로 국내에서 사용하고 있는 기숙이나 국외(미국, 일본)의 침수방지 기술 및 대책, 침수시 가이드라인 등을 조사하였다. 또한 지하공간이 침수되었을 때 일어날 수 있는 위험성에 대하여 이론적인, 기술적인 조건에 대하여 조사하였다. 이를 토대로 지하공간의 유형 즉, 지하주택, 지하상가, 지하공공시설(지하차도, 지하철, 전철, 지하변전소)에 대한 구체적인 침수방지 기숙에 대한 기준을 제시함으로써 궁극적으로는 지방자치단체, 관련기관, 연구기관에서 지하공간 침수방지대책에 대한 기초자료로 활용할 수 있을 것으로 판단된다.

  • PDF

Indoor radon concentrations in house and public buildings (국내 가옥 및 공공건물내 라돈농도)

  • 김창규;김용재;이재성;노병환
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.67-68
    • /
    • 2003
  • 라돈은 일반적으로 가장 잘 알려진 천연 방사성핵종 중 하나로서 무향 무색의 불활성기체이며 붕괴과정에서 알파입자를 방출한다. 라돈에 의한 피폭선량은 라돈붕괴에 의해 생성된 라돈자손이 호흡기관 표면에 침착되어 방출하는 알파선에 기인한다. 따라서, 피폭선량에 주로 기인하는 것은 라돈 자신이 아니라 그의 단 반감기 라돈자손들이다. 이처럼 라돈은 잘 알려진 폐암 유발원으로서 고농도의 라돈에 장기간 노출되는 경우 폐암을 유발할 수 있다. UNSCEAR 보고서(1993)는 자연 환경중에서 인간이 받는 연간 총 피폭선량인 2.4 mSv중 약 50%에 해당하는 1.15 mSv가 라돈과 그 자손에 의한 것이며 대부분 옥내에서의 호흡에 의해 비롯된다고 평가하고 있다. (중략)

  • PDF