• Title/Summary/Keyword: 골-슬개건-골 이식물

Search Result 9, Processing Time 0.025 seconds

ACL Reconstruction: Bone-Patellar Tendon-Bone Autograft (전방 십자 인대 재건술: 골-슬개건-골 자가이식물)

  • Koh, Hae-Seok
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.102-108
    • /
    • 2005
  • The incidence of anterior cruciate ligament tears is increasing as a result of the increasing participation of individuals of all ages in high-risk sports. Endoscopic anterior cruciate ligament reconstruction using autogenous central third bone-patellar tendon-bone graft is the most commonly used method. With regard to BPTB graft as the go]d standard in ACL reconstruction, there are no data that refute this claim to date. Author reviewed the biomechanical properties, donor site morbidity and selection of the bone-patellar tendon-bone graft and described the surgical technique of endoscopic ACL reconstruction using BPTB autograft.

  • PDF

Anterior Cruciate Ligament Reconstruction Using Autologous Bone-patellar Tendon-bone (자가 골-슬개건-골을 이용한 전방십자인대 재건술)

  • Kyung, Hee-Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.88-91
    • /
    • 2010
  • 전방십자인대 재건술시 자가건 선택에 대해서는 많은 논쟁의 소지가 존재하며 많은 보고들이 나오고 있으나, 현 시점에서 이식건으로써 자가 골-슬개건-골이 표준(gold standard)라는 주장은 이제 변화하고 있으며, 골-건 고정방법의 개선에 따른 조기 슬관절 안정성의 호전으로 자가 슬괵건의 사용이 점점 증가되고 있는 추세이다. 자가 골-슬개건-골은 이식건으로써 강한 물성, 튼튼한 고정, 장기 추시에서 높은 성공률 등으로 젊고, 강한 활동을 요하는 운동선수에서 종종 선택되고 있으며 조기에 강한 활동으로의 운동 복귀를 할 수 있다. 그러나 슬관절 전방 통증, 무릎을 꿇을 때의 통증, 슬개골골절, 슬개-대퇴 관절의 염발음 및 대퇴사두근력의 감소 등 이식물 채취로 인한 공여부 이환이 문제가 되었다. 그래서 자가 골-슬개건-골의 이식건으로서의 문제점 및 문헌상 고찰을 하여 논하고자 한다.

  • PDF

The Resolving Method of Graft-Tunnel Mismatch in Arthroscopic ACL Reconstruction Using Bone-Patellar Tendon-Bone Graft (골-슬개건-골을 이용한 관절경적 전방십자인대 재건술시 이식물-터널 길이의 부조화를 줄이는 방법)

  • Cho, Se-Hyun;Park, Hyung-Bin;Ha, Sung-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.97-101
    • /
    • 1999
  • Purpose : The purpose of this study is to prevent thc graft-tunnel mismatch by measuring the patellar tendon length, intertunnel distance, tibial tunnel length and by obtaining appropriate bone block length. Materials and Methods : Authors analyzed 15 patients who had taken the anterior cruciate ligament reconstruction from March 1997 to June 1999. Tibial guide was always set on the "endo" $40^{\circ}$ position(Acufex, MA, USA). We measured the following indices, intertunnel distance(X), tibial tunnel length(T), patellar tendon length(N), tibia bone plug length(Y). Both of the femoral tunnel length(F) and the patellar bone plug length(P) were made in 25mm. The appropriate tibial bone plug length was simply calculated by subtracting the patellar tendon length from the sum of the intertunnel distance and thc tibial tunnel length(Y=X+T-N). Results : The average indices were as follows ; the intertunnel distance(X) was $23.4{\pm}1.4mm$, the tibial tunnel length(T) was $43.6{\pm}1.7mm$, the patellar tendon length was $40{\pm}2.4mm$, and the tibia bone plug length was $27{\pm}2.4mm$. Conclusion : In authors' endoscopic technique, establishment of individually determined optimal tibial bone plug length, based on total tunnel length and patellar tendon length could prevent the problem of graft-tunnel mismatch.

  • PDF

Autograft Versus Allograft Bone-Patellar Tendon-Bone in Anterior Cruciate Ligament Reconstruction - A Comparison Of Mid-Term Follow-Up Results - (자가 및 동종 골-슬개건-골을 이용한 전방 십자 인대 재건술 -중기 추시 결과의 비교-)

  • Cho, Sung-Do;Cho, Su-Hyun;Woo, Jong-Ken;Yoo, Chang-Hyun;Park, Moon-Su;Lew, Sog-U
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.1
    • /
    • pp.14-18
    • /
    • 2004
  • Purpose: To compare the mid-term follow-up results of anterior cruciate ligament(ACL) reconstruction with the bone-patellar tendon- bone(BTB) autograft to those with the BTB allograft. Materials and Methods: Retrospective study was performed in 59 cases with BTB autograft and 42 cases with BTB allograft. Evaluations include Lysholm score, 2000 IKDC subjective knee score, Shelbourne patello-femoral pain score , Lachman test, pivot shift test, KT-1000 arthrometer test and 2000 IKDC knee examination. Results: There were no significant statistic differences between two groups in Lysholm score and 2000 IKDC subjective knee score of more than 70 (p<0.05). Five cases(8.5%) showed the patello-femoral pain score less than 80 according to Shelboume with autograft group and two cases(4.8%) with allograft group (p<0.05). Lachman test, pivot shift test and KT-1000 arthrometer test showed no significant statistic differences between two groups(P<0.05). Fifty-four cases(91.5%) were normal or nearly normal according to the 2000 IKDC knee examination with autograft group and thirty-eight cases(90.4%) with allograft group(p<0.05).Conclusion: BTB allograft as well as BTB autograft is considered to be an acceptable choice for ACL reconstruction.

  • PDF

Comparison Study of Anterior Cruciate Ligament Reconstruction Using Bone-Patella Tendon-Bone Autograft and Achilles Tendon Allograft (이식건에 따른 관절경하 전방 십자 인대 재건술의 비교 -자가 골-슬개건-골과 동종 아킬레스건의 비교-)

  • Seo, Joong-Bae;Jung, Hong-Geun;Kim, Myung-Ho;Park, Hee-Gon;Yoo, Moon-Jib;Byun, Woo-Sup;Lee, Joo-Hong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.132-136
    • /
    • 2005
  • Purpose: The purpose of this study was to compare the clinical results of the arthroscopic anterior cruciate ligament reconstruction used by Bone-Patella tendon-Bone autograft and Achilles tendon allograft. Materials and Methods: We reviewed the results of patients who had been managed with arthroscopic anterior cruciate ligament reconstruction using different graft such as Bone-Patella tendon-Bone autograft and Achilles les tendon allograft. 60patients (average age, 33.5 years)were retrospectively evaluated. The one group(average age, 33.4 years) was 32 patient who had been managed with arthroscopic anterior cruciate ligament reconstruction using Bone-Patella tendon-Bone autograft. The other group(average age, 32.1 years) was 28 patient who had been managed with arthroscopic anterior cruciate ligament reconstruction using Achilles tendon allograft. 2 groups were evaluated subjectively by Lysholm knee scoring scale and objectively by KT-2000 arthrometer. The follow-up period was more than a year(average, 18 month). An early rehabilitation protocol was instituted. Results: On Lysholm knee scoring scale, the final evaluation was nearly normal in all patients. We could not find statistical difference among the two groups by KT-2000TM arthrometer. Conclusion: The use of allografts may be an acceptable choice for ACL reconstruction.

  • PDF

The Result of the Arthroscopic Reconstruction of Posterior Cruciate Ligament with Autogenous or Allogenous Graft (자가 또는 동종 이식물을 이용한 후방 십자 인대 재건술 후의 결과)

  • Chon Je-Gyun;Kim Eui-Soon;Choi Bo-Yeul;Yoon Chang-Hoon;Lee Jeong-Woung;Sun Doo-Hoon;Moon Myung-Sang
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.74-79
    • /
    • 2001
  • Purpose : The purpose of this study is to evaluate the clinical results after arthroscopic PCL reconstruction and to compare the clinical results after arthroscopic PCL reconstruction using BPTB(bone patellar tendon bone) autograft(Group I : 11 cases), Achilles tendon allograft(Group II : 7 cases) and BPTB allograft(Group 111.6 cases). Materials and Methods : We reviewed the result of 24 patients who had been managed with arthroscopic reconstruction using different graft materials such as BPTB autograft, Achilles tendon allograft and BPTB allograft. Twenty-four patients(average age, 37 years) with PCL rupture were retrospectively evaluated more than one year(average, 31 months) after having arthroscopic posterior cruciate ligament reconstruction. The clinical results were evaluated by IKDC ligament standard evaluation form, using $KT-2000^{TM}$ knee ligament arthrometer and also evaluated Lysholm knee scoring scale. Results : The final evaluation was nearly normal in 11 patients($45\%$ in Group I, $43\%$ in Group II, $50\%$ in Group III). The corrected posterior sagging was abnormal(side to side difference more than 6mm) in 8 patients($36\%$ in Group I, $29\%$ in Group II, $33\%$ in Group III). We could not find significant difference among three groups by IKDC scale. Conclusion : Comparing with other reports, our overall results were not satisfactory. And also, we could not find any remarkable difference among the three groups. Further research is necessary to evaluate new surgical approaches as well as improved techniques for capsular and collateral ligament injuries.

  • PDF

Graft Length of the Bone-patellar Tendon-bone for Reconstruction of ACL (골-슬개건-골을 이용한 전방십자인대 재건술에서 이식물의 길이)

  • Kim, Jung-Man
    • Journal of the Korean Arthroscopy Society
    • /
    • v.1 no.1
    • /
    • pp.55-62
    • /
    • 1997
  • Various surgical techniques has been advocated for reconstruction of anterior cruciate ligament using the bone-patella tendon-bone graft. Recently endoscopic technique provides good clinical results, with minimal skin incision, accurate positioning of the graft to the femoral tunnel, and decreasing wear rate of the graft. But the graft-tunnel mismatch remains problematic in endoscopic technique. The purpose of this paper is to described causes of the graft-tunnel mismatch and to provide important steps to prevent or minimize the graft-runnel mismatch following anterior cruciate ligament while using the endoscopic technique. Our guideline for prevention of the graft-tunnel mismatch are as follows: (1) The tunnel should he positioned closely to isometric point as much as possible. (2) Anterior placement of the tunnel should be avoided. (3) The change of graft length should be within 2mm between flexion and extension position.

  • PDF

Arthroscopic Posterior Cruciate Ligament Reconstruction with Preservation of the Remnant Posterior Cruciate Ligament (남아 있는 후방 십자 인대 다발을 보존한 관절경하 후방 십자 인대 재건술)

  • Ahn Jin Hwan;Ha Kwon Ik;Chung Yoon Sung;Yang Il Soon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.97-104
    • /
    • 2000
  • Purpose : The majority of PCL deficient knees have some intact remnant PCL bundles. In these cases, the remnant PCL bundles were removed fur easy passage of graft(especially in bone-patellar tendon-bone graft). The purpose of study is to report the results of PCL reconstruction by posterior transseptal portal technique and by preserving the remnant posterior cruciate ligament bundles. Materials & Methods : From November 1993 to June 1999, 44 arthroscopic posterior cruciate ligament reconstructions have been performed by one surgeon. We studied 37 knees those were followed up over 1 year among them. The mean age($14\~56$ years) was 31.8 years. The average follow-up period was 17.8 months($12\~61$ months). The graft materials were 29 double-loop hamstring autografts, 4 double-loop hamstring allografts and 4 Achilles tendon-bone allograft. Results : There are significant improvement of the preoperative subjective symptoms. The last follow-up shows that the average Lysholm knee score was markedly improved from 59.8 pre-operation to 89.2 post-operation and the average KT 2000 side difference was decreased from 11.1mm pre-operation to 2.3 mm post-operation. Follow-up MRI showed that the graft was healed with remnant posterior cruciate ligament bundles as one ligament. Conclusion : The posterior trans-septal portal makes it possible to locate the exact tibial tunnel. The arthroscopic PCL reconstruction preserving the remnant of original PCL bundles seems to provide the good result.

  • PDF

Comparison of Results of ACL Reconstruction According to the Fixation Materials (Metal & Bioabsorbable Interference Screw and RIGIDfix) (금속, 흡수성 간섭 나사못 및 RIGIDfix를 이용한 전방 십자 인대 재건술의 결과 비교)

  • Lim Hong Chul;Wang Joon Ho;Rho Young Jin;Hwang Jin Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.206-214
    • /
    • 2003
  • Purpose : To analysis each clinical results after arthroscopic ACL reconstruction with using variable fixatives which are metallic and bioabsorbable interference screw, and RIGIDfix. Therefore, We reported the clinical reliability and safty of ACL reconstruction using RIGIDfix. Materials and Methods : We evaluated the results of arthroscopic ACL resconstruction with patellar tendon autograft among three groups, of which group 1 is used metal interference screw for 44 patients, group 2 used bioabsorbable interference screw for 47 patients, group 3 used RIGIDfix for 42 patients. We compared the clinical results by physical examination (anterior drawer test, Lachman test and pivot shift test), Lysholm score and KT-2000 arthrometer and compared the radiological results by measurement of tunnel and fixatives position and widening and by MRI findings. We analyzed the results by SAS 8.2 Ducan. Tukey and paired t-test Results : Physical instability was in 5 cases, which group 2 had 4 cases and group 3 had 1 case. Lysholm score improved from 59.8. 64.4, 61 to 90.1, 92.3. 92. KT-2000 arthrometer instability improved from 9.20, 10.2, 9.5 to 1.43. 1.62. 2.00 (p=0.478). Radiologically, all cases had excellent tunnel position and cyst change was observed the 8 cases in the group 2, but, all 20 cases 2nd MRI had signal change of peri-fixatives. But, no correlation of clinical results. Conclusion : No statistical difference of clinical instability was found among three groups. And femoral tunnel changes were much observed in group I, II than III. We considered the RIGIDfix has much advantages because the short operation time, better fixation position and much bone contact surface. But, further long term follow up study was needed.

  • PDF