• Title/Summary/Keyword: 골 고정원

Search Result 88, Processing Time 0.03 seconds

Full-mouth rehabilitation with pressed ceramic technique using provisional restorations (Pressed ceramic technique을 이용하여 제작되는 완전 도재관 완전 구강 회복 증례)

  • Roh, Hyun-Sik;Woo, Yi-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.47-51
    • /
    • 2013
  • With the introduction of dental implants, restoration of missing teeth with conventional fixed or removable partial dentures is being replaced with implants. Especially, with young patients, not only longevity but also esthetic factors need to be considered. Implant restorations provide long-term success functionally but, esthetic complications such as, marginal exposure due to gingival recession, loss of the papilla and dark color of metal abutments may occur. Recently, zirconia restorations with CAD/CAM technology provide functional, biocompatible and esthetic restorations possible. All-ceramic restorations using the pressed ceramic technique show better fracture toughness values than those of the conventional porcelain veneering technique. Pressed ceramic technique creates the veneer design in wax and the lost wax technique is used to create the restoration. The final contour of the restoration may be controlled during wax-up. A 22-year old female patient was restored with dental implants and zirconia restorations using the pressed ceramic technique presenting short-term but optimistic prognosis.

Comparison of Treatment Methods in Completely Displaced Supracondylar Fractures of Humerus in Children - Open reduction and pinning versus Closed reduction and pinning- (완전 전위된 소아 상완골 과상부 골절의 치료 방법 비교 -관혈 정복 후 내고정술과 도수 정복 후 경피적 핀 고정술의 결과 비교-)

  • Lee, Sang-Ho;Choi, Joon-Cheol;Na, Hwa-Yeop;Lee, Young-Sang;Choi, Jun-Won;Lee, Sang-Yoon;Won, Jong-Won;Sin, Min-Ho;Kim, Woo-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.1
    • /
    • pp.96-104
    • /
    • 2006
  • Purpose: To evaluate and compare the results of children with displaced supracondylar fractures of humerus treated with open reduction and pinning with closed reduction and pinning. Materials and Methods: From March 2002, we treated 17 patients with completely displaced supracondylar fractures under the age of 7 with a minimal follow up period of 6 months. 9 patients were treated with closed reduction and pinning and 8 patients were treated with open reduction and pinning. The clinical results were evaluated with Flynn's criteria. Time to bone union was also analyzed for these two set of patients. Results: The group treated with open reduction had 6 excellent and 2 good results for change in carrying angles, 5 excellent, 2 good and 1 fair results for motion loss evaluated by Flynn's criteria. The average time to bony union for this group was 5.8 weeks. The group treated with closed reduction had 6 excellent, 2 good, and 1 fair results for change in carrying angles and 7 excellent, 1 good and 1 fair results for motion loss. The average time to bony uinon for this group was 3.7 weeks. Conclusion: In treating completely displaced supracondylar fractures of humerus in children, the closed reduction method and open reduction method all showed good results. But the operation time, duration of hospital stay and time to union was somewhat shorter for the patients treated with closed redution and pinning.

Complications of PCL Reconstruction using Tibial Inlay Technique (경골 Inlay 방법을 이용한 후방 십자 인대 재건술의 합병증)

  • Kim Myung-Ho;Park Hee-Gon;Yoo Moon-Jib;Byun Woo-Sup;Shim Shang-Ho
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.3 no.2
    • /
    • pp.128-133
    • /
    • 2004
  • Purpose: This study was planned to evaluate complications? of posterior cruciate ligament (PCL) reconstruction with tibial inlay technique using autogenous bone-patellar tendon-bone graft. Materials and Methods: From September 1994 to January 2004, we analyzed surgical complications in fifty-seven patients with fifty-eight cases who underwent PCL reconstruction. Fifty of them were male and seven female. The mean age of the patients was 35(15$\~$73). Twenty eight cases of injury were isolated PCL, while thirty cases had associated injury of knee. The causes of injury were thirty-nine cases of traffic accident, seven sport injuries, seven fall down injuries, and five of others. The follow-up study was done at 4 weeks, 3 months,6 months and 1 year after surgery. KT-2000 arthrometer and posterior stress X-ray were used to examine the stability of the knee joint and the Lysholm Knee Score and a variety of clinical complications were evaluated. Results: Although the mean score of the preoperative Lysholm Knee Score was 43.2, the postoperative score was increased to 87.9. The preoperative mean value of knee stability using KT-2000 arthrometer was 8.75 mm(6.2$\~$14.3 mm) but the postoperative mean was 3.41 mm(2.1$\~$10.6 mm). The intraoperative complications were: one case of popliteal artery injury with compartment syndrome, one case of patellar fracture, two cases of 20$^{\circ}$ flexion loss, and two cases of anterior cortical penetration of the screw through proximal tibia during screw fixation. The postoperative complications were: eleven cases of knee instability, one case of patellar fracture, five cases of extension loss, thirteen cases of flexion loss, twenty-one cases of around knee pain and eight cases of kneeling pain. Conclusion: After PCL reconstruction with tibial inlay technique using autogenous bone-patella tendon-bone graft, complications were observed in this study. Careful attention during and after the operation, as well as rehabilitation must be required.

  • PDF

A Clinical Analysis of 101 blunt sternal fractures (둔상에 의한 흉골골절 101례의 임상적 분석)

  • Kim, U-Jong;Lee, Jun-Bok
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.713-718
    • /
    • 1997
  • Fracture of the sternum has been considered as a serious injury and also associated with major complications such as myocardial, major thoracic vascular, and spinal injury. Retrospective datas from blunt trauma victims admitted to our hospital were analyzed to determine significance of sternal fractures and possible associated injures. 101 sternal fractures by blunt trauma were admitted from january, 1986 to december, 1995. Frequency was about 3.51 olo of the nonpenetrating chest trauma. The ratio of male to female was 1.82 versus 1. Most common cause in the stemal fracture was high decelerating injury(73 cases). Most common fracture site was sternal body(75 cases). Average days of adm ssion were 26 days. Abnormal ECG findings were sinus bradycardia(Teases), complete or incomplete RBBB(6 cases), sinus tachycardia(4 cases), specific S-T change(3 cases), 1st degree A-V block(2 cases), LVH(1 case), PVC(1 case), and Low voltage(1 case). CPK-MB was increased about 32.Lolo of sternal fractures. Except of expired 2 patients, patients were treated with conservative treatment(94 cases) and open reductions & steel wire fixations(5 cases). Complication after operation was wound infection(1 case). Causes of death were 1 hypovolemia and 1 acute respiratory distress syndrome. In conclusion, although sternal fracture is less frequent, and mostly treats with conservative treatment, it shoed be carefully observed because of critical associated injuries.

  • PDF

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE BONE ANCHORED FIXED PROSTHESIS ACCORDING TO THE LOAD CONDITION (골유착 고정성 보철물 하에서 하중조건에 따른 삼차원 유한요소법적 분석)

  • Yang, Soon-Ik;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.780-806
    • /
    • 1995
  • The purpose of this study was to describe the application of 3D finite element analysis to determine resultant stresses on the bone anchored fixed prosthesis, implants and supporting bone of the mandible according to fixture numbers and load conditions. 4 or 6 fixtures and the bone anchored fixed prosthesis were placed in 3D finite element mandibular arch model which represents an actual mandibular skull. A $45^{\circ}$ diagonal load of 10㎏ was labiolingually applied in the center of the prosthesis(P1). A $45^{\circ}$ diagonal load of 20㎏ was buccolingually applied at the location of the 10mm or 20mm cantilever posterior to the most distal implant(P2 or P3). The vertical distribution loads were applied to the superior surfaces of both the right and the left 20mm cantilevers(P4). In order that the boundary conditions of the structure were located to the mandibular ramus and angle, the distal bone plane was to totally fixed to prevent rigid body motion of the entire model. 3D finite element analysis was perfomed for stress distribution and deflection on implants and supporting bone using commercial software(ABAQUS program. for Sun-SPARC Workstation. The results were as follows : 1. In all conditions of load, the hightest tensile stresses were observed at the metal lates of prostheses. 2. The higher tensile stresses were observed at the diagonal loads rather than the vertical loads 3. 6-implants cases were more stable than 4-implants cases for decreasing bending and torque under diagonal load on the anterior of prosthesis. 4. From a biomechanical perspective, high stress developed at the metal plate of cantilever-to-the most distal implant junctions as a consequence of loads applied to the cantilever extension. 5. Under diagonal load on cantilever extension, the 6-implants cases had a tendency to reduce displacement and to increase the reaction force of supporting point due to increasing the bendign stiffness of the prosthesis than 4-implants cases. 6. Under diagonal load on cantilever extension, the case of 10mm long cantilever was more stable than that of 20mm long cnatilever in respect of stress distribution and displacement. 7. When the ends of 10mm or 20mm long cantilever were loaded, the higher tensile stress was observed at the second most distal implant rather than the first most distal implant. 8. The 6-implants cases were more favorable about prevention of screw loosening under repeated loadings because 6-implants cases had smaller deformation and 4-implants cases had larger deformation.

  • PDF

A Case of Fat Embolism Syndrome of Fat Globules Found in BAL Fluid after Recovery from Acute Respiratory Failure (급성호흡부전 호전 후 기관지폐포세척에서 지방과립구가 확인된 지방색전증후군 1예)

  • Park, Song Ree;Kim, Hyun Soo;Lee, Jae Hyung;Kim, Sang Heon;Kim, Tae Hyung;Yoon, Ho Joo;Park, Sung Soo;Shin, Dong Ho;Park, Chan Kum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.6
    • /
    • pp.562-566
    • /
    • 2006
  • Fat embolism syndrome is a rare clinical diagnosis of dyspnea with acute respiratory failure and neurological signs caused by a traumatic long bone fracture. We report a case of fat embolism in a 22 year-old man after a traffic accident. Dyspnea and stuporous mental changes developed on the $1^{st}$ day after the external fixation operation of a left metaphyseal femur fracture. On the following day, he was transferred from a hospital to this one because of acute respiratory failure. After recovery, macrophages with fat droplets were found in the bronchoalveolar lavage fluid 1. It is important to diagnose a fat embolism as the correct cause of acute respiratory failure through the BAL in the acute state of fat embolism syndrome It is believed that clinically apparent or sometimes hidden fat embolism syndrome can be diagnosed from the BAL during the recovery state.

Three-dimensional finite element analysis of initial tooth displacement according to force application point during maxillary six anterior teeth retraction using skeletal anchorage (골격성 고정원을 이용한 상악 6전치 후방 견인시 힘의 적용점 변화에 따른 치아 이동 양상에 관한 유한 요소법적 분석)

  • Kim, Chan-Nyeon;Sung, Jae-Hyun;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.33 no.5 s.100
    • /
    • pp.339-350
    • /
    • 2003
  • The purpose of this study was to investigate the micro-implant height and anterior hook height to prevent maxillary six anterior teeth from lingual tipping and extruding during space closure. We manufactured maxillary dental arch form, bracket and wire, using the computer aided three-dimensional finite element method. Bracket was $.022'{\times}.028'$ slot size and attached to tooth surface. Wire was $.019'{\times}.025'$ stainless steel and $.032'{\times}.032'$ stainless steel hook was attached to wire between lateral incisor and canine. Length of hook was 8mm and force application points were marked at intervals of In. Four micro-implants were implanted on alveolar bone between second premolar and first molar. The heights of them were 4, 6, 8, 10mm starting from wire. We analyzed initial displacement of teeth by various force application point applying force of 150gm to each micro-implant and anterior hook. The conclusions of 4his study are as the following : 1. When the micro-implant height was 4m and the anterior hook height was 5mm and below, anterior teeth were tipped lingually. When the anterior hook height was 6mm and above, anterior teeth were tipped labially. 2. When the micro-implant height was 6mm and the anterior hook height was 6mm and below, the anterior teeth were tipped lingually. When the anterior hook height was 6m and above, the anterior teeth were tipped labially. But lingual tipping of anterior teeth decreased and labial tipping Increased when the micro-implant height was 6mm, compared with 4mm micro-implant height. 3. When the micro-implant height was 8mm and the anterior hook height was 2mm, the anterior teeth were tipped lingually. When the anterior hook height was 3mm and above, labial tipping movement of the anterior teeth increased proportionally. 4. When the micro-implant height was 10mm and the anterior hook height was 2mm and above, labial tipping of the anterior teeth increased proportionally. 5. As the anterior hook height increased, aterior teeth were tipped more labially. But extrusion occurred on canine and premolar area because of the increase of wire distortion. 6. Movement of the posterior teeth was tipped distally during maxillary six anterior teeth retraction using micro-im plant because of the friction between bracket and were Based on the results of this study, we could predict the pattern of the tooth movement according to position of micro-implant and height of anterior hook. It seems that we can find the force application point for proper tooth movement in consideration of inclination of anterior anterior teeth, periodontal condition, overjet and overbite

A Patterns of Care Study of the Various Radiation Therapies for Prostate Cancer among Korean Radiation Oncologists in 2006 (Patterns of Care Study를 위한 2006년 한국 방사선종양학과 전문의들의 전립선암 방사선치료원칙 조사연구)

  • Kim, Jin-Hee;Kim, Jae-Sung;Ha, Sung-Whan;Shin, Seong-Soo;Park, Won;Cho, Jae-Ho;Suh, Chang-Ok;Oh, Young-Taek;Shin, Sei-Won;Kim, Jae-Chul;Jang, Ji-Young;Nam, Taek-Keun;Choi, Young-Min;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.96-103
    • /
    • 2008
  • Purpose: To conduct a nationwide academic hospital patterns of the practice status and principles of radiotherapy for prostate cancer. The survey will help develop the framework of a database of Korean in Patterns of Case Study. Materials and Methods: A questionnaire about radiation treatment status and principles was sent to radiation oncologists in charge of prostate cancer treatment at thirteen academic hospitals in Korea. The data was analyzed to find treatment principles among the radiation oncologists when treating prostate cancer. Results: The number of patients with prostate cancer and treated with radiation ranged from 60 to 150 per academic hospital in Seoul City and 10 to 15 outside of Seoul City in 2006. The primary diagnostic methods of prostate cancer included the ultrasound guided biopsy on 6 to 12 prostate sites(mean=9), followed by magnetic resonance imaging and a whole body bone scan. Internal and external immobilizations were used in 61.5% and 76.9%, respectively, with diverse radiation targets. Whole pelvis radiation therapy(dose ranging from 45.0 to 50.4 Gy) was performed in 76.9%, followed by the irradiation of seminal vesicles($54.0{\sim}73.8$ Gy) in 92.3%. The definitive radiotherapy doses were increased as a function of risk group, but the range of radiation doses was wide(60.0 to 78.5 Gy). Intensity modulated radiation therapy using doses greater than 70 Gy, were performed in 53.8% of academic hospitals. In addition, the simultaneous intra-factional boost(SIB) technique was used in three hospitals; however, the target volume and radiation dose were diverse. Radiation therapy to biochemical recurrence after a radical prostatectomy was performed in 84.6%; however, the radiation dose was variable and the radiation field ranged from whole pelvis to prostate bed. Conclusion: The results of this study suggest that a nationwide Korean Patterns of Care Study is necessary for the recommendation of radiation therapy guidelines of prostate cancer.