• Title/Summary/Keyword: 골전도

Search Result 39, Processing Time 0.025 seconds

Evaluation of the Bone Defect Regeneration after Implantation with Cuttlebone in Rabbit (토끼에서 오적골 이식 후 골 결손부 재생 평가)

  • Won, Sangcheol;Lee, Joo-Myoung;Park, Hyunjung;Seo, Jongpil;Cheong, Jongtae
    • Journal of Veterinary Clinics
    • /
    • v.32 no.5
    • /
    • pp.410-416
    • /
    • 2015
  • Bone grafting is widely used to bridge major bone defects or to promote bone union. In the evaluation of bone defect regeneration, 5 mm-diameter defects were created in rabbit calvaria. Concerning biocompatibility, fibrous capsule thickness of CBHA (hydroxyapatite from cuttlebone) was significantly thinner than that of CB (cuttlebone) and CHA (hydroxyapatite from coral) (p < 0.05) at 2 and 4 weeks after implantation. Concerning 12-week total changes of radiologic gray-level histogram, CBHA was significantly higher than CHA (p < 0.05). In the evaluation of bone defect regeneration, bone formation of CHA was significantly higher than that of CB and CBHA (p < 0.05). Based on the clinical and histological results, CBHA would be a safe material for use inside the body and has more effective osteoconduction than CB. It is suggested that CBHA is a valuable bone graft material.

The Effects of Calcium-Phosphate Coated Xenogenic Bone and Type I Collagen for Bone Regeneration on the Calvarial Defects in Rabbits (Ca-P 박막 이종골과 제 1형 교원질이 토끼 두개골 결손부의 골재생에 미치는 영향)

  • Kim, Chang-Han;Park, Jin-Woo;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.223-241
    • /
    • 2004
  • The purpose of this present study evaluated the osseous response around Ca-P coated xenogenic bone and compared osteogenic potential of Ca-P coated xenogenic bone to that of combination with type I collagen derived from bovine tendon as a biocompatible binder to prevent migration of bone particle on the repair of calvarial defects in rabbits. To study the effects of Ca-P coated xenogenic bone and collagen on bone healing, four 5-mm-diameter skull defect were made in calvaria with trephine filled with an autogenous bone chip or Ca-P coated xenogenic bone or Ca-P coated xenogenic bone and type I collagen (1:1 mixture by volume) or left empty. The defects were evaluated histologically at 1, 2, 4 and 8 weeks following implantation. Ca-P coated xenogenic bone at the calvarial defects of rabbits showed osteoconductivity at the margin of defect in the early stage of bony healing, but no direct contact with new bone was observed. With time passed by, it was resorbed slowly and showed consistent inflammatory reaction. An additional use of type I collagen derived from bovine tendon improved clinical handling, but no new bone formation was observed histologically. Above all, autogenous bone graft showed most prominent healing in quantity and density of new bone formation. According to this study, the use of Ca-P coated xenogenic bone alone and combination with type I collagen did not showed effective healing in quantity and density of new bone formation.

A Parameter Study on the Frequency Characteristics Control of Implantable Bone Conduction Transducer Using FEA (FEA를 이용한 이식형 골전도 진동체의 주파수 특성 제어에 관한 파라미터 연구)

  • Shin, Dong Ho;Kim, Myoung Nam
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.8
    • /
    • pp.1040-1048
    • /
    • 2020
  • In this study, in order to improve the implantable bone conduction transducer of the prototype proposed by Shin et al., the effect of the element parameters of the transducer on the frequency characteristics was analyzed using electromagnetic and mechanical vibration analysis. Electromagnetic analysis was performed on the size of the permanent magnet and the distance between the metal plate and the coil to derive an optimal structure that generates the maximum Lorentz force. In addition, mechanical vibration analysis was performed on the cantilever structure of the vibrational membrane in order to minimize the distortion of the transducer and to have a frequency characteristic suitable for conductive hearing loss compensation. The frequency characteristics of the transducer of the optimal structure derived through finite element method were compared with the simulation results of the previous transducer. As a result, the output magnitude (displacement) of the transducer designed with the optimal structure generated an average 8.8 times higher than the previous transducer, and the resonance frequency was generated at 0.9 kHz.

Feasibility of Bone Conduction Earphones for Auditory Brain-Computer Interface (청각 기반 뇌-컴퓨터 인터페이스 구현을 위한 골전도 이어폰의 활용 가능성)

  • Lee, Ju-Ok;Ju, Gyeong-Ho;Kim, Do-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.22-27
    • /
    • 2020
  • Auditory stimuli are commonly used in various electroencephalogram experiments, also in EEG-based brain-computer interface systems. However, using conventional earphones that blocks the ear canal attenuates or even blocks external environmental sound which might cause loss of crucial information from surroundings. Instead, bone-conductive earphones are able to deliver sound through vibration without blocking the ear canal. To investigate the feasibility of the bone-conductive earphones for auditory-stimuli based experiments, we compared N100 event-related potential features as well the event-related spectral perturbation and inter-trial coherence of auditory steady-state response between conventional and bone-conductive earphones. The results showed no significant differences between bone conduction and conventional earphones regardless of distinct sound pressures. This result shows that bone conductive earphones can be used for auditory experiments when the environmental sound is crucial to the user.

Lidar for the BlindObstacle detection using sensors (시각장애인을 위한 라이다 센서를 활용한 장애물 감지)

  • Hyung Mook Lee;Ju Hwan Park;Jin Hwi Kim;Seoung Woo Lee;Seong Jeon;Jun Won Choi;Se Jeong Heo;Sung Jin Kim
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.01a
    • /
    • pp.133-136
    • /
    • 2023
  • 많은 사람이 "다음 생에 성적 소수자나 이주민, 장애인으로 태어나고 싶니?"라는 질문을 받는다면 대부분 사람은 선뜻 "그렇다"라고 대답하기 어렵다. 그 근본적인 이유는 질문 속 사회적 약자들은 사회에서 다양한 불평등을 마주하고 있다는 의미일 것이다. 본 논문에서는 여러 소수자 중 시각장애인을 위한 보행 보조 기구를 제작하였다. 시각장애인들이 사용하는 지팡이는 지면의 장애물 파악에 도움은 되지만 공중에 떠 있는 장애물을 파악하고 피하기 어렵다. 이러한 단점을 보완하고자 라이다 센서를 이용하여 장애물 감지가 가능한 서비스를 시각장애인에게 제공한다. 라이다 센서는 레이저 광원을 방출하여 목표물에서 튕겨 되돌아오는 특성을 이용하여 사용자에게 전방에 장애물이 감지되면 시각장애인에게 TTS로 경고음을 제공한다.

  • PDF

Convergence study of mechanical properties and biocompatability of Ti Gr4 surface coated with HA using plasma spray for ossoeintegration (골융합 촉진을 위한 Ti Gr4의 HA 코팅에 대한 물리적 특성과 생체안정성에 대한 융합적 연구)

  • Hwang, Gab-Woon
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.145-151
    • /
    • 2021
  • This study aimed to investigate the efficient conduct of HA coating on Ti Gr4 for the practical use of medical device. Ti Gr4 alloy specimens measuring 𝜱 25mm × 1mm were sprayed with hydroxyapatite using thermal spray according to ASTM F1185-88. The surface was evaluated at #120, #400, #1,000 sandpaper and barrel finishing. Each coating properties was analyzed using SEM, UTS 20,000psi cap. and in vitro cytotoxicity. Surface morphology consists of well molten particles with very little resolidified or unmolten areas. The average Ca/P ratio is 1.74 which is in good agreement with theoretical value of 1.67. The average roughness Ra is very representative of roughness of specimen. The coatings are dense and well adhered to the substrate. The average bond strength was 61.74 MPa with a standard deviation of 4.06 which indicates fairly reliable results for ASTM 633 type tests. Variations in results from jig design, epoxy used, crosshead speeds etc. in vitro cytotoxicity result had a Grade 3. The results of the study are expected to be helpful in osseointegration and plasma-spray HA coated Ti Gr4 are more satisfactory in HA coating thickness elevation which is preferable to any other system.

Electrophysiological Analysis in Diabetic Patients with Abnormal Sensation and Pain (이상감각과 통증을 호소하는 당뇨병 환자의 전기생리학적 특징 분석)

  • Yang, Jiwon;Lee, Yeong-Bae
    • Science of Emotion and Sensibility
    • /
    • v.19 no.4
    • /
    • pp.111-118
    • /
    • 2016
  • Patients with type 2 diabetes mellitus can complain of abnormal sensation and pain which derived from the peripheral nerve damage. Various words used to be describe abnormal sense and pain, such as sharp, hot, dull, cold, sensitive, and itch. To diagnose diabetic peripheral neuropathy, several screening instruments (Neuropathic Pain Scale, NPS; Michigan Neuropathy Screening Instruments, MNSI) and electrophysiological study can be used. In this study, we aim to analyze and compare the clinical and electrophysiological characteristics of 11 patients with diabetes mellitus and abnormal sense/pain (Disease Group, DG) and 10 patients with diabetes mellitus and normal sense (Control Group, CG). In addition, we aim to reveal correlation between NPS subscore and electrophysiological parameters. As a result, the scores of NPS and MNSI in DG were significantly higher. In nerve conduction study, median motor nerve and peroneal nerve showed significant functional change. Also, median motor nerve, posterior tibial nerve and sural nerve showed negative correlation as NPS subscore increased. These results mean increased pain can be associated with abnormal nerve function. It needs to be further explored for larger size of subjects to get confirmative results.

Influence of stress and pure tone audiometry on noise-exposed dental laboratory technicians by dental instrument (치과기공 소음 노출이 치기공과 학생의 스트레스와 순음청력에 미치는 영향)

  • Yon, Jung-Min;Lee, Ju-Hee;Kim, Dae-Hyun;Lee, Og-Kyoung
    • Journal of Digital Convergence
    • /
    • v.14 no.4
    • /
    • pp.363-370
    • /
    • 2016
  • Noise is unwanted sound that is the reason of the stress and hearing loss. The current study attempted to estimate whether the noise of dental laboratory affected stress and pure tone audiometry (PTA) of dental laboratory technicians (DLTs) using heart rate variability, air and bone conduction audiometry. The age, heights, and weights of DLTs were resembled control. Standard deviation of normal to normal interval such as stress resistance and normalized HF of DLTs were significantly decreased, but heart rates, normalized LF, and LF/HF ratio of DLTs were significantly increased compared with control. In air conduction audiometry of DLTs, significant increments of thresholds encountered in 125, 250, 500, 1000, 2000, 3000, 4000, and 6000 Hz in the right ears and 125, 250, 500, 1000, and 2000 Hz in the left ears. Thresholds of bone conduction audiometry in both ears were significantly increased in 250, 500, 1000, 2000, and 4000 Hz. The findings in this study provide that stress and hearing loss observed in noise-exposed DLTs at dental laboratory. Therefore, proper safety precautions should be carried out at dental laboratory.

Co-sputtering법으로 제작된 화합물 반도체 박막형 태양전지에서 $CuInSe_2$(CIS) 광흡수층의 열처리 효과

  • Kim, Hae-Jin;Lee, Hye-Ji;Son, Seon-Yeong;Park, Seung-Hwan;Kim, Hwa-Min;Hong, Jae-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.269-269
    • /
    • 2010
  • 현재 화석연료의 부족으로 인한 에너지 수급의 불균형, 자연환경의 파괴로 인해 대체에너지 개발이 절실히 요구되고 있다. 이러한 문제점을 극복하기 위한 방안으로 태양전지에 대한 관심이 높아지고 있다. 기존 결정형 실리콘 태양전지와 비교해 화합물 반도체를 기반으로 한 박막형 태양전지는 친환경적인 제품이면서 제조원가를 절감시킬 수 있고, 반영구적인 수명 및 값싼 기판을 활용할 수 있는 장점으로 인해 활발한 연구가 진행되고 있다. 본 실험에서는 Co-sputtering법으로 제작된 $CuInSe_2$(CIS)를 광활성층으로 한 박막형 태양전지에서 실온 ${\sim}550^{\circ}C$의 다양한 온도에서 후열 처리된 CIS 박막들의 전기적, 구조적, 광학적인 특성들을 분석하였다. 제작된 박막들 가운데 Hall Effect 측정결과 $550^{\circ}C$에서 후열 처리된 박막이 가장 높은 1.227E+22(/$cm^3$)의 캐리어 농도와 1.581(cm/$V{\cdot}s$)의 홀 이동도를 가지며, 3.092E-4(${\Omega}{\cdot}cm$)의 가장 낮은 비저항 값을 갖는 것으로 나타났다. EFM 측정결과 열처리 하지 않은 박막에 비해 후열처리된 CIS 박막의 전도성이 전체적으로 높아졌다. 특히, $550^{\circ}C$에서 후열 처리된 박막의 표면은 전체적으로 전기 전도성이 높은 결정립들이 골고루 분포하며 가장 높은 표면 포텐셜 에너지 값을 갖는 것으로 나타났다. 박막들의 구조적 특성을 분석하기 위해 SEM과 XRD를 측정한 결과, $350^{\circ}C$에서 후열 처리된 박막들은 열처리 되지 않은 박막과 비교해 표면형상 변화가 일어났으며, $550^{\circ}C$에서 후열 처리된 CIS 박막들은 $CuInSe_2$(112) 방향이 향상된 chalcopyrite-like 구조를 가지면서 박막 밀도가 높고 결정립의 크기가 증가된 것을 확인하였다. 이는 박막 성장시 기판온도의 상승으로 CIS 박막 내에서 셀레늄의 확산과 상호작용으로 3원 화합물이 재결정화되어 구조적인 특성향상에 기여하였기 때문이다. 결론적으로 본 연구는 CIS 광활성층에서 후열 처리의 효과들 뿐만아니라 박막 증착시 co-sputtering법을 이용함으로써 증착시간의 감소 및 대면적화와 대량생산으로도 적용 가능함을 제시하고자 한다.

  • PDF

Noise Cancellation Algorithm of Bone Conduction Speech Signal using Feature of Noise in Separated Band (밴드 별 잡음 특징을 이용한 골전도 음성신호의 잡음 제거 알고리즘)

  • Lee, Jina;Lee, Gihyoun;Na, Sung Dae;Seong, Ki Woong;Cho, Jin Ho;Kim, Myoung Nam
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.128-137
    • /
    • 2016
  • In mobile communication, air conduction(AC) speech signal had been commonly used, but it was easily affected by ambient noise environment such as emergency, military action and rescue. To overcome the weakness of the AC speech signal, bone conduction(BC) speech signal have been used. The BC speech signal is transmitted through bone vibration, so it is affected less by the background noise. In this paper, we proposed noise cancellation algorithm of the BC speech signal using noise feature of decomposed bands. The proposed algorithm consist of three steps. First, the BC speech signal is divided into 17 bands using perceptual wavelet packet decomposition. Second, threshold is calculated by noise feature during short time of separated-band and compared to absolute average of the signal frame. Therefore, the speech and noise parts are detected. Last, the detected noise parts are removed and then, noise eliminated bands are re-synthesised. In order to confirm the efficiency of the proposed algorithm, we compared the proposed algorithm with conventional algorithm. And the proposed algorithm has better performance than the conventional algorithm.