• 제목/요약/키워드: 골재 등급

검색결과 23건 처리시간 0.022초

국내 골재 품질 현황 및 골재등급에 따른 콘크리트의 역학적 특성에 관한 연구 (Domestic Aggregate Quality Status and Mechanical Properties of Concrete According to Quality of Aggregate)

  • 민충식;박종호;정용;이재현;김용로;김효락
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.207-208
    • /
    • 2012
  • This study is aimed to utilize for basic material of concrete quality management through evaluate properties of fresh and hardened concrete with the aggregate quality. As a result, fine aggregate's slump change of between one grade was 8~82% and in case of coarse aggregate, slump change of between one grade was 2~22% on same mixing condition. The unit water for same workability condition, unit water was increased 16kg/㎥ with decreasing of one grade for fine aggregate and unit water was increased 5kg/㎥ with decreasing of one grade for coarse aggregate.

  • PDF

콘크리트를 위한 매화천 A, B 지역 골재의 암석기재학적 시험 (ASTM C 295) (Petrographic Examination of Aggregates for Concrete from Maewhacheon A, B area (ASTM C 295))

  • 정지곤
    • 한국광물학회지
    • /
    • 제14권2호
    • /
    • pp.85-98
    • /
    • 2001
  • 콘크리트 구조물에 사용되는 골재의 화학적 안전성을 진단하는 방법 중의 하나인 암석기재학적 시험(ASTM C 295)에 관한 연구로서, 이 연구를 위하여 골재의 입도 분석, 피막 검사, 풍화 ·오염상태, 암석학적 기재, 그리고 알칼리-골재 반응성 광물 및 암석의 정성·정량적 분석을 실시하였다. 경남 울진군 매화천 유역 A, B 지역의 하천 골재에 대하여 암석기재학적 방법으로 검사한 결과 풍화상태는 F(신선) 등급과 WS(약간 풍화) 등급이며 골재의 피막과 오염 상태는 우려할 정도는 아니다. 알칼리-골재 반응 광물이나 구조적으로 취약한 암석이 함유된 골재는 매화천 A 지역 골재 전체의 26 wt.%, B 지역은 19 wt.%로 집계되는데 이는 양호한 골재로 볼 수 없기 때문에 화학적 방법과 몰탈바 방법으로 더욱 정밀한 시험을 거쳐 안전성이 확인되어야 한다.

  • PDF

고칼슘 플라이애쉬를 이용한 알칼리 활성화제 무첨가 저강도 유동화 채움재 특성 평가 (The Characterization of Controlled Low Strength Material (CLSM) Using High CaO Fly Ash without Chemical Alkaline Activator)

  • 임상형;추현욱;이우진;이창호
    • 한국지반환경공학회 논문집
    • /
    • 제17권12호
    • /
    • pp.17-26
    • /
    • 2016
  • 본 연구에서는 등급 외 플라이애쉬 중 산화칼슘 함량이 높은 플라이애쉬를 저강도 유동화 채움재(controlled low strength material, CLSM)의 바인더로써 활용 가능성을 알아보았다. 사용된 플라이애쉬는 상대적으로 산화칼슘 함량이 높은 플라이애쉬를 배출하는 유동층형 보일러(circulating fluidized bed combustion boiler, CFBC)에서 시료를 채집하여 사용하였다. 배합한 시료의 유동성, 일축압축강도, 단위중량 등을 파악하여 CLSM 시료의 공학적 특징을 알아보았으며, 미세구조관찰과 X선 회절분석을 통한 CLSM 시료의 경화 메커니즘을 파악하였다. 실험 수행 결과 유동성을 만족하는 함수비는 42에서 85%의 범위를 보였으며, 유동성 시험 결과 골재의 종류와 관계없이 골재율이 증가함에 따라 유동성이 증가하는 것으로 나타났다. 일축압축강도는 0.3MPa에서 1.9MPa의 분포를 보였다. 규사를 골재로 사용한 경우 골재율이 증가함에 따라 일축압축강도는 증가하였으나, 바텀애쉬를 골재로 사용한 경우 골재율이 증가함에 따라 일축압축강도는 감소하였다. 미세구조관찰 결과와 X선 회절분석을 통해 CLSM 시료는 고분자 중합반응과 시멘트 수화반응을 통해 강도를 발현하는 것으로 확인하였다. 본 연구의 결과로부터 산화칼슘 함량이 높은 플라이애쉬의 자체 경화성을 이용하여 저강도 유동화 채움재로써 활용이 가능하다고 판단된다.

순환잔골재를 혼입한 자기충전 콘크리트의 현장적용을 위한 실험적 연구 (An Experimental Study on Field Application of Self-Compacting Concrete Using Recycled Fine Aggregate)

  • 류재석;송일현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권4호
    • /
    • pp.193-203
    • /
    • 2011
  • 본 연구에서는 폐콘크리트에서 발생하는 순환잔골재가 구조용 재료로서 많은 문제점이 있음을 인지하고 순환잔골재가 포함하고 있는 미분말이 강도증진 효과와 유동성을 증가 시킬 수 있다는 특성을 이용하여 자기충전 콘크리트(Self-Compacting Concrete, 이하 SCC로 표기)에 활용하게 되었다. 즉 순환잔골재가 갖는 미분말이 자기충전 콘크리트 특성인 고강도(40 MPa 이상)와 높은 유동성(JSCE 2등급)을 발현하기에 적당하여 폐콘크리트에서 발생하는 순환잔골재를 일반잔골재 대비 순환잔골재의 혼입률을 25%씩 증가시켜, 총 5수준으로 달리하여 자기충전 콘크리트에 적용하였으며, 이에 따라 굳지 않은 콘크리트의 물리적 특성, 경화한 콘크리트의 역학적 및 내구 특성을 검토하여 순환잔골재를 자기충전 콘크리트 재료로서 활용 가능성을 검토하고자 한다. 그 결과 물리적, 역학적 및 내구특성의 5수준 배합비율 중 일반잔골재 대비 순환잔골재는 50% 혼입률까지 적용가능하다는 결론을 얻었으며, 그 이상의 혼입률에서는 오히려 성능저하가 발생한다는 것을 알 수 있었다. 또한 실생활에서의 적용 가능성을 알아보기 위한 실구조물의 적용성이 차후 검토 되어야 할 것으로 판단된다.

골재 지역 특성이 불분명한 콘크리트의 탄산화 속도 및 강도 상관성 (Relationship between Carbonation Rate and Compressive Strength in Concrete with Unclear Local Aggregate Qualities)

  • 남진원;김형기;권성준
    • 한국건설순환자원학회논문집
    • /
    • 제12권3호
    • /
    • pp.246-253
    • /
    • 2024
  • 혼화재(슬래그 미분말 또는 플라이애시)를 혼입한 콘크리트가 재령 초기에 촉진 탄산화 실험에 노출될 경우, 수화반응과 포졸란 반응, 그리고 탄산화 반응이 동시에 발생하므로 매우 복합한 탄산화 거동이 발생한다. 특히 골재의 품질이 좋지 못한 경우에는 강도 특성과 탄산화 거동 특성이 명확하지 않다. 본 연구에서는 정보가 명확하지 않은 3개 산지 골재(A, B, C)를 대상으로 3 수준의 배합강도 등급 (24 MPa, 27 MPa, 30 MPa)의 콘크리트 시편을 제조하였다. 재령 7일과 28일 압축강도 실험을 수행하였으며, 촉진 탄산화 실험을 8주간 수행하여 탄산화 속도계수를 도출하였다. 도출된 압축강도, 탄산화 속도계수를 각 배합특성 및 골재특성을 고려하여 상관성을 분석하였다. 또한 국내 탄산화 설계식을 이용하여 목표 내구수명에 따른 최소 피복두께를 도출하였으며, 탄산화 설계의 변수(방향계수 및 유효 물-결합재 상수)의 보완 필요성을 제시하였다.

굵은골재 종류 변화에 따른 고성능 콘크리트의 폭렬특성 (Spalling Properties of High Performance Concrete Designed with the Various Types of Coarse Aggregate)

  • 허영선;박용규;김호림;지석원;양성환;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.95-98
    • /
    • 2006
  • This study investigates spalling properties of high performance concrete, 60MPa clan, made with the various types of coarse aggregate and adding ratio of polypropylene(PP) fiber. As experimental parameters, totally sixteen specimens of ${\phi}100{\times}200mm$ in size are prepared: one specimen for control without fiber, ten specimens with different coarse aggregate types, along with 0.05, 0.1, 0.15 percent of PP fiber in each. 1 hour fire test is conducted and then spalling appearance, spalling degree and residual compressive strength are examined. In addition, sit specimens made with two types of coarse aggregate site, along with same adding ratio of fiber are supplementally done, and only spalling properties is examined. Test results showed that control concrete and most specimens containing 0.05% of PP fiber exhibited 4 to 3 level of spalling degree, resulting severe explosive spalling, except for the specimen using basalt aggregate(Bc) showing 2 to 3 level of that. Especially, the Bc specimen containing 0.1% of the fiber exhibited that residual compressive strength value was 32%, which is 10% higher than other specimens using limestone or granite. Spalling resistance performance was also effective as aggregate size increase.

  • PDF

섬유보강 시멘트 기반 재료의 내충격 성능에 미치는 굵은 골재 혼입 영향 평가 (An Evaluation of Coarse Aggregate Mixed Effect on Impact Resistance of Fiber Reinforced Cement-Based Material)

  • 이은진;김규용;김홍섭;이상규;손민재;윤민호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.37-38
    • /
    • 2016
  • In this study, it evaluate the coarse aggregate mixed effect to impact resistance performance of the fiber reinforced cement-based material. The type of fiber is Hooked-ended steel fiber, and mixed 1vol.% in concrete and cement composites. The impact experiment was conducted by using a spherical shape projectile diameter of 25mm to 170m/s speed and Impact resistance performance was evaluated by measuring the fracture grade, fracture diameter and depth.

  • PDF

국산 매립회의 골재특성 평가 및 매립회 콘크리트의 내구 성능 평가 (Evaluation for Properties of Domestic Pond Ash Aggregate and Durability Performance in Pond Ash Concrete)

  • 이봉춘;정상화;김주형;권성준
    • 콘크리트학회논문집
    • /
    • 제23권3호
    • /
    • pp.311-320
    • /
    • 2011
  • 화력발전 부산물 중 플라이애쉬는 포졸란 반응을 활용하여, 콘크리트 혼화재로 적극적으로 사용되고 있으나, 바텀애쉬는 주로 매립되어 재활용이 많이 요구되는 실정이다. 매립회에는 바텀애쉬와 플라이애쉬가 혼재되어 있는데, 이 연구에서는 국내 6개 발전소 매립회를 수집하고 5가지 치환율(10%, 20%, 30%, 50%, 70%)을 고려하여 매립회의 공학적 특성과 매립회 콘크리트의 역학적/내구 성능이 평가되었다. 골재 실험으로는 조립률, 밀도 및 흡수율, 안전성, 염화물 함유량, 유해이온 함유량, 알칼리 골재 반응 등이 수행되었으며, 매립회 콘크리트에 대해서는 경화 전 특성으로 슬럼프, 공기량 시험을, 경화된 콘크리트에 대해서는 압축강도, 건조수축, 염해 저항성 및 확산계수, 촉진 탄산화 실험, 동결 융해 실험 등이 수행되었다. 매립회는 일반 잔골재보다 큰 흡수율과 작은 밀도를 가지고 있었으나, 콘크리트 골재로 사용 가능하며, 매립회 콘크리트 역시 일반 콘크리트에 해당하는 적절한 성능을 확보하고 있었다. 특히 치환율이 증가함에 따라 강도는 증가하였으며, 우수한 탄산화 저항성을 확인하였다. 최종적으로 실험 결과를 정량적으로 등급화 하여 가장 우수한 매립회 및 매립회 콘크리트의 적용 제한 사항을 도출하였다. 이 연구는 매립회 및 매립회 콘크리트의 공학적 특성을 중심으로 다루고 있으며, 실제 구조물에 대한 모형 실험을 통한 적용성 평가가 추가로 진행될 것이다.

재료분리 평가정수(EIS)에 의한 재료분리 평가법의 제안 (Suggestion of Segregation Evaluation Method based on Evaluation Index for Segregation(EIS))

  • 한천구;김기철;박병관
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.923-926
    • /
    • 2008
  • 국내 외에서는 건축물들이 고유동 및 고성능 콘크리트의 사용량이 증가되고 있는 추세이다. 그러나 고유동 고성능 콘크리트는 유동성 향상을 위해 고성능 감수제를 다량으로 사용할 경우 유동성은 향상되었을 망정 재료분리가 발생하여 콘크리트 구조물에 악영향을 미치게 된다. 이러한 콘크리트의 재료분리 저항성을 판정하기 위한 방법으로 육안관찰, 굵은골재 씻기 시험, L Flow 철근사이의 통과성 시험, 점성측정에 의한 방법 등이 있는데, 이 같은 방법들은 매우 복잡하고 번거로우므로 실무적용에는 어려움이 있다. 그러므로 콘크리트의 재료분리 저항성을 보다 손쉬운 방법으로 평가하기 위한 방법으로 슬럼프플로우치를 슬럼프치로 나눈 EIS를 제안하기 위하여 기존 참고자료를 바탕으로 분석하였다. 그 결과 고유동 콘크리트의 경우 시방적 규정으로 재료분리 여부를 관리할 경우에는 EIS 값을 2.5 이하로 규정하면 타당할 것으로 사료되고, 성능적으로 EIS를 규정할 경우에는 1등급 2,2 이하, 2등급 2.2$\sim$2.4, 3등급 2.4$\sim$2.6, 2.6 이상은 재료분리로 관리하면 합리적일 것으로 사료된다.

  • PDF

화재피해를 입은 콘크리트구조물의 수열온도 추정을 위한 실험적 연구 (An Experimental Study for Supposed Heating Temperature of Deteriorated Concrete Structure by fire Accident)

  • 권영진
    • 한국화재소방학회논문지
    • /
    • 제18권3호
    • /
    • pp.51-56
    • /
    • 2004
  • 철근콘크리트구조물에 화재가 발생하게 되면 콘크리트내의 시멘트 수화물과 골재의 상반된 거동으로 조직이 연화되며 열응력 등으로 균열이 발생하여 부분적 혹은 전체구조시스템에 심각한 영향을 끼칠 수 있는 손상이 발생하여, 철근 콘크리트 구조물의 내구성을 현저히 저하시키게 된다. 콘크리트의 화재피해 상황은 콘크리트에 사용된 혼화재료 및 골재 등 사용재료의 영향을 받게 되며 설계기준 강도에 따라 그 피해 상황 역시 다르게 나타나기 때문에 화재피해를 입은 콘크리트 구조물의 열화 진단은 화재에 의한 열화 메커니즘을 바탕으로 이루어져야 하며, 이를 위해서는 고온에 노출된 콘크리트의 공학적 특성에 관한 기초자료가 반드시 필요하다. 그러므로 본 연구에서는 설계기준 강도 및 사용재료에 따라 콘크리트를 제조 하여 고온환경에 노출시켜 폭열상태, 초음파속도, 압축강도 등을 측정하여 화재로 열화된 콘크리트 구조물의 재사용 여부 및 피해 등급 결정을 위한 정밀 진단과 보수ㆍ보강공법의 선정을 위한 기초 자료로 제시하고자 한다.