• Title/Summary/Keyword: 골다공증 검사

Search Result 97, Processing Time 0.021 seconds

Diagnostic Coincidence of Radiologic Measurement Methods of the Proximal Femur Anterior-posterior Projection for Assessment of Osteoporosis (근위대퇴부 정면 영상을 이용한 골다공증 평가 시 방사선적 계측의 진단일치도)

  • Kang, Yeong-Han;Cho, Kwang-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.353-360
    • /
    • 2012
  • The purpose of this study was to determine whether there are relationships between radiologic parameters for osteoporosis by the proximal femur radiograhps and bone mineral density, as assessed by Dual Energy X-ray Absorptiometry(DEXA). Proximal femur anterior-posterior projection were taken from 112 individuals who undergoing DEXA. Radiographic parameters including canal-to-calcar ratio(CCR) and cortical thickness indices(CTI) were measured and compared with bone mineral density($g/cm^2$), T-score. The intramedullary femoral canal width(FW) and calcar width(CW) at osteoporosis group was significantly larger than that of control group. The CCR were correlated negatively with bone mineral density($g/cm^2$)(r=-0.340, p<0.01), and the CTI were correlated positively(r=0.624). The diagnostic accuracy of CCR for osteoporosis was 63.4%, and kappa value was 0.271. And the accuracy of CTI was 67.0%, and kappa value was the level of fair agreement(${\kappa}$=0.258). The proximal femur with large CCR and small CTI had lower T-scores. When evaluating proximal femur anterior-posterior radiographs, those patients with the thinnest femur diaphyseal cortices should be referred for further osteoporosis investigation.

Effect of Adefovir Dipivoxil on the Inhibition of Osteogenic Differentiation of Mesenchymal Stem Cells and Osteoblasts (아데포비어가 중간엽 줄기세포와 조골세포의 골형성 분화 억제에 미치는 영향)

  • Ho PARK
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.4
    • /
    • pp.284-290
    • /
    • 2023
  • Adefovir dipivoxil (ADV) is used for the treatment of hepatitis and acquired immunodeficiency syndrome, but long-term use can cause osteoporosis. In this study, the effect of ADV on the osteocyte maturation process was evaluated at the level of undifferentiated cells using mesenchymal stem cells (MSCs) and osteoblasts (MG63). First, MSCs and MG63 cells were treated with ADV at different concentrations, and then a Cell Counting Kit-8 analysis was performed to determine the effect on the proliferation of each cell. Additionally, crystal violet and Hoechst staining were performed for the morphological analysis of each cell and nucleus. To determine the cause of cell hypertrophy, the transforming growth factor-beta (TGF-β) expression was investigated, and alkaline phosphatase (ALP) staining and activity were measured to determine the degree of differentiation of the MSCs and MG63 cells into mature osteocytes. The results confirmed that the ADV increases the expression of TGF-β in MSCs and MG63 cells, causing cellular and nuclear hypertrophy, and can cause osteoporosis by inhibiting cell proliferation and affecting the differentiation of mature osteocytes. Therefore, it is believed that these results can be used as a basis for understanding the adverse effects of ADV at a cytological level in basic medicine and clinical research.

Design and Development of the Database for the Korean Genome and Health Study (한국인 유전체역학 정보 DB 설계 및 구축)

  • 양은주;박용철;고인송;오범석;김규찬
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.10b
    • /
    • pp.844-846
    • /
    • 2003
  • 국립보건원 유전체연구소는 안산-안성 지역에 거주하는 45세 이상 69세 이하의 성인을 대상으로 고혈압, 당뇨, 골다공증, 천식, 비만 등 한국인의 총 국민의료비용에서 큰 부분을 차지하는 중요 만성질환에 초점을 맞추어 코호트 연구를 수행하고 있다. 이에 검진대상자의 설문 및 임상검사를 통하여 수집되는 개인식별 데이터, 생활습관 데이터 등의 설문정보와 다양한 임상검사정보에 대한 체계적 저장ㆍ관리와 향후 수행될 대규모 정보 분석을 위해 유전체역학 정보 DB를 설계.구축하였다.

  • PDF

The Study on Bone Mineral Density Measurement Error in Accordance with Change in ROI by Utilizing Dual Energy X-ray Absorptiometry (DEXA를 이용한 골밀도 측정시 검사자의 ROI 변화에 따른 골밀도 측정값의 오차에 관한 연구)

  • Lee, Yun-Hong;Lee, In-Ja;Yong, Hyung-Jin
    • Journal of radiological science and technology
    • /
    • v.35 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • Dual Energy X-ray Absorptiometry(DEXA) is commonly used to diagnose Osteoporosis. The errors of DEXA bone density operation are caused by operator, bone mineral density meter, blood testing, patient. We focus on operator error then study about how much influence operator's region of intest(ROI) in bone testing result. During from March to July in 2011. 50 patients ware selected respectively from 30, 40, 50, 60, and 70 age groups who came to Korea University Medical Center(KUMC) for their Osteoporosis treatment. A-test was performed with usually ROI and B-test was performed with most widely ROI. Then, We compare A-test and B-test for find maximum difference of T-score error which occurred operator ROI controlling. Standard deviation of T-score of B-test showed 0.1 higher then A-test in femur neck. Standard deviation of B-test showed 0.2 higher then A-test in Ward's area which in Greater trocanter and Inter trocanter. Standard deviation of B-test showed 0,1 lower then A-test in L-1. Bone density testing about Two hundred patients results are as follow. When operator ROI was changed wider than normal ROI, bone density of femur was measured more higher but bone density of L-spine was measured more lower then normal bone density. That means, sometime DEXA bone density testing result is dependent by operator ROI controlling. This is relevant with the patient's medicine and health insurance, thus, tester always keep the size of ROI for to prevent any problem in the patient.

A Status Report on Dual Energy X-ray Absorptiometry Quality Control in Korea (이중에너지 방사선흡수 골밀도 장치의 품질관리 현황)

  • Kim, Jung-Su;Rho, Young-Hoon;Lee, In-Ju;Kim, Sung-Su;Kim, Kyoung-Ah;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.527-534
    • /
    • 2016
  • Dual-energy X-ray absorptiometry (DEXA) is the most widely used technical instrument for evaluating bone mineral content (BMC) and density (BMD) in patients of all ages. In 2016, DEXA devices operating is 5617 in Korea. In this study we investigated the quality of management practices survey for DEXA equipment and we analyzed it. We got a survey response rate of 12.6%. Accurate bone densitometry test is used data for estimation a patient's risk of fracture. However, improper bone densitometry will increase the possibility of causing a false positive. Therefore. it is essential to use the proper aids accurate bone densitomenty to be performed, and the quality control of the device to reduce the error factor of the tester through the training to reduce error for the device and the attitude.

The Effect of 12 Weeks of Combined Training on Body Composition, Health-Related Physical Fitness, and Bone Mineral Density of Obese and Osteoporotic Intellectual Disabilities-Case study (12주간 복합트레이닝이 비만과 골다공증 지적장애인의 신체조성, 건강체력, 골밀도에 미치는 영향-사례연구)

  • Han, Dong-Ki;Yang, Han-Nah;Seo, Jin-Hee
    • Journal of Digital Convergence
    • /
    • v.16 no.2
    • /
    • pp.375-383
    • /
    • 2018
  • The purpose of this study was to investigate the effect of exercise training on health-related physical fitness and osteoporosis after 12 weeks of combined training for adults with intellectual disabilities diagnosed with obesity and osteoporosis. The subjects conducted a combined training program consisting of aerobic exercise and strength training twice a week for 12 weeks. Body composition and bone mineral density were measured before exercise, 6, 12 weeks, and health-related physical fitness was measured before and after exercise. Body weight and body fat decreased after exercise and bone density increased after exercise compared to before exercise. Muscle strength, muscle endurance and flexibility were improved after exercise compared to before exercise. It was confirmed that the 12 week compound training increased the leg strength and improved the functions such as walking and running, and increased the health-related fitness and increased bone mineral density.

Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry (대퇴골 경부 골절 환자에서 골다공증 평가를 위한 다중검출 CT의 이용: 이중에너지 X-선 흡수계측법과의 비교)

  • Hyo Jeong Lee;Ji Young Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.173-181
    • /
    • 2021
  • Purpose To evaluate the ability of the Hounsfield unit (HU) measurement of the femoral neck during multidetector computed tomography (MDCT) for assessing osteoporosis compared with dual-energy X-ray absorptiometry (DXA). Materials and Methods Forty-two patients with femoral neck fractures who underwent MDCT and DXA from July to December 2016 were included in this study. HU measurements were made of the cancellous portions of the normal contralateral femoral neck on MDCT. Bone mineral density (BMD) and T-scores were obtained at the femur DXA. Correlations of HU values with BMD and T-scores were analyzed using Spearman's correlation test. Results The mean BMD and T-score of the femoral neck were 0.650 g/cm2 and -2.4, respectively. The mean HU values for the normal, osteopenia, and osteoporosis groups were 131.9, 98.9, and 41.3, respectively. HU values at the femoral neck were positively correlated with BMD (r2 = 0.670; p < 0.001) and T-scores (r2 = 0.676; p < 0.001). Conclusion The HU values of the femoral neck on MDCT are significantly correlated with BMD and T-scores of femur DXA. The HU values may serve as a diagnostic tool for the screening of regional bone quality when MDCT is performed for other reasons.

Dependences of Ultrasonic Parameters for Osteoporosis Diagnosis on Bone Mineral Density (골다공증 진단을 위한 초음파 변수의 골밀도에 대한 의존성)

  • Hwang, Kyo Seung;Kim, Yoon Mi;Park, Jong Chan;Choi, Min Joo;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.502-508
    • /
    • 2012
  • Quantitative ultrasound technologies for osteoporosis diagnosis measure ultrasonic parameters such as speed of sound(SOS) and normalized broadband ultrasound attenuation(nBUA) in the calcaneus (heel bone). In the present study, the dependences of SOS and nBUA on bone mineral density in the proximal femur with high risk of fracture were investigated by using 20 trabecular bone samples extracted from bovine femurs. SOS and nBUA in the femoral trabecular bone samples were measured by using a transverse transmission method with one matched pair of ultrasonic transducers with a center frequency of 1.0 MHz. SOS and nBUA measured in the 20 trabecular bone samples exhibited high Pearson's correlation coefficients (r) of r = 0.83 and 0.72 with apparent bone density, respectively. The multiple regression analysis with SOS and nBUA as independent variables and apparent bone density as a dependent variable showed that the correlation coefficient r = 0.85 of the multiple linear regression model was higher than those of the simple linear regression model with either parameter SOS or nBUA as an independent variable. These high linear correlations between the ultrasonic parameters and the bone density suggest that the ultrasonic parameters measured in the femur can be useful for predicting the femoral bone mineral density.

Calcium Bioavailability and Antiosteoporotic Effects of Cheonggukjang Containing High Poly-Gamma Glutamate Contents (고함량 폴리감마글루탐산(PGA) 청국장에 대한 칼슘 생체이용률 및 골다공증에 미치는 영향)

  • Lee, Mu-Jin;Jung, Ho-Kyung;Sim, Mi-Ok;Jang, Ji-Hun;Kim, Tae-Mook;Lee, Hyun-Joo;Lee, Ki-Ho;An, Byeong-Kwan;Cho, Jung-Hee;Jang, Min-Cheol;Yong, Ju-Hyun;Kim, Jong-Choon;Cho, Hyun-Woo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.11
    • /
    • pp.1544-1551
    • /
    • 2016
  • Various types of fermented soybean foods are consumed in various Asian countries, including China, Indonesia, Japan, Korea, and Vietnam. Cheonggukjang is a Korean whole soybean paste fermented by Bacillus subtilis and regarded as a healthy food. The objective of this study was to investigate the Ca-bioavailability and anti-osteoporotic effects of cheonggukjang (CGJ) containing high poly-gamma glutamate (PGA) contents in an animal model. Blood samples were collected from the jugular vein at 0, 0.5, 1, 2, 3, 4, and 5 h after a single oral dose in male rats. Ca-bioavailability in CGJ containing high PGA contents was approximately 3~5 times higher than that of natural CGJ. Female rats were either sham-operated (sham; n=5) or surgically ovariectomized (OVX; five animals per group) and then administered to OVX control, raloxifene hydrochloride (RLX) 1 mg/kg/d, or CGJ containing high contents of PGA (20 and 200 mg/kg/d) for 12 weeks. Serum osteocalcin concentration was significantly lower in the CGJ 200 mg/kg/d group compared with the OVX control group. Serum progesterone concentration was significantly higher in the CGJ 200 mg/kg/d group compared with the OVX control group. Reduction grade of the trabecular bone decreased in the RLX 1 and CGJ 200 mg/kg/d group compared with that of the OVX control group. In conclusion, CGJ 200 mg/kg/d may have inhibitory effects on osteoporosis in OVX rats, and Ca-bioavailability was improved in CGJ containing high PGA contents.

Dietary behaviors and nutritional status according to the bone mineral density status among adult female North Korean refugees in South Korea (한국에 거주하고 있는 북한이탈주민 여성의 골밀도에 따른 식생활과 영양상태)

  • Kim, Su-Hyeon;Lee, Soo-Kyung;Kim, Sin-Gon
    • Journal of Nutrition and Health
    • /
    • v.52 no.5
    • /
    • pp.449-464
    • /
    • 2019
  • Purpose: North Koreans could be at higher risk for their bone health because of previous periods of severe famine and the continuing low availability of food. This study determined the bone mineral density (BMD) status and its relationship with dietary behaviors and nutrient intake of North Korean refugees (NKR) in South Korea (SK). Methods: This cross-sectional study analyzed 110 female NKR from a NORNS cohort of a non-probability sample of adult NKR in Seoul. BMD examined by DEXA was used to divide participants into the normal group (NG) and the non-normal group (NNG) according to the WHO guideline. A self-administered questionnaire included questions on age, the socioeconomic situation in North Korea (NK) and SK, the food security in NK and SK, and the health behaviors, dietary behaviors, and food frequency questionnaire administered in SK. A one-day 24-hr recall was conducted and the results were analyzed by using CanPro. SPSS was used to analyze whether BMD and related dietary behaviors and nutrient intakes differed according to the groups. Results: NG (62.7%) was significantly younger and had a lower abdominal obesity score than NNG (p < 0.001). While 14.5% of NG reported experiencing menopause, all of NNG reported experiencing menopause. The NG more frequently consumed the dairy group of foods (9.6 times a week) than did the NNG (4.8 times a week) after the statistics were adjusted for age (p < 0.007). The NG consumed significantly more animal protein and animal calcium than did the NNG (p = 0.01, p = 0.009, respectively). Calcium intake was low with 49.3% of NG, and 78.0% of the NNG reported consuming calcium lower than the estimated average requirement. Only calcium showed an index of nutrient quality lower than one in both groups. Conclusion: These results showed that NKR women and possibly all North Korean women are at high risk for bone health and they consumed low levels of bone-related nutrients, and this should be considered for the nutrition policy for NKR and North Korea.