• Title/Summary/Keyword: 고주파 치료

Search Result 103, Processing Time 0.027 seconds

Tumor Recurrence in Hepatocellular Carcinoma Patients after Radiofrequency Ablation: Portal Hypertension as an Indicator of Recurrence of Hepatocellular Carcinoma (간세포암 환자의 고주파열치료 후 종양 재발: 예후인자로서 문맥고혈압)

  • Jang, Seong Won;Cho, Yun Ku;Kim, Ju Won;Gil, Je Ryung;Kim, Mi Young;Lee, Young
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.5
    • /
    • pp.264-270
    • /
    • 2018
  • Purpose: To evaluate the effect of portal hypertension on the tumor recurrence in patients with hepatocellular carcinoma (HCC) and without hepatic decompression following radiofrequency ablation (RFA). Materials and Methods: Treatment-naïve HCC patients within the Milan criteria and with Child-Pugh class A were included in this study, who had performed RFA in our hospital between January 2010 and March 2017. Univariate and multivariate analyses using the Cox proportional hazard model were performed to find the predictors of local or distant tumor recurrence. Results: Overall, 178 patients were included in this study. Median follow-up period was 40.2 months. The difference in the local tumor progression rates depending on the absence or presence of portal hypertension was not statistically significant (p = 0.195). The 1-, 3-, and 5-year distant intrahepatic tumor spread rates were 6.6%, 29.5%, and 537% in patients without portal hypertension, and 23.4%, 51.9%, and 63.6% in patients with portal hypertension, respectively. The difference was statistically significant (p = 0.011). Univariate and multivariate analysis showed that portal hypertension was an independent predictor for distant intrahepatic tumor spread (p = 0.008). Conclusion: For HCC patients with Child-Pugh class A, portal hypertension adversely affected distant intrahepatic tumor progression.

Result of Cox Maze Procedure with Bipolar Radiofrequency Electrode and Cryoablator for Persistent Atrial Fibrillation - Compared with Cut-sew Technique - (양극고주파전극과 냉동프로브를 이용한 지속성 심방세동의 수술 결과 - 절개/봉합술식과 비교 -)

  • Lee, Mi-Kyung;Choi, Jong-Bum;Lee, Jung-Moon;Kim, Kyung-Hwa;Kim, Min-Ho
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.710-718
    • /
    • 2009
  • Background: The Cox maze procedure has been used as a standard surgical treatment for atrial fibrillation for about 20 years. Recently, the creators have used a bipolar radiofrequency electrode (Cox maze IV procedure) instead of the incision and suture (cut-sew) technique to make atrial ablation lesions for persistent atrial fibrillation. We investigated clinical outcomes for the Cox maze procedure with a bipolar radiofrequency electrode and cryoablator in patients with persistent atrial fibrillation, and compared results with clinical outcomes of the cut-sew procedure. Material and Method: Between April 2005 and July 2007, 40 patients with persistent atrial fibrillation underwent Cox maze IV procedure with a bipolar radiofrequency electrode and cryoablator (bipolar radiofrequency group). Surgical outcomes were compared with those of 35 patients who had the cut-sew technique for the Cox maze III procedure. All patients had concomitant cardiac surgery. Postoperatively, the patients were followed up every 1 to 2 months. Result: At 6 months postoperatively, the conversion rate to regular sinus rhythm was not significantly different between the two groups: 95.0% for the bipolar radiofrequency ablation group; 97.1% for the cut-sew technique (p=1.0). At the end of the follow-up period, the conversion rate to regular sinus rhythm was also not significantly different (92.5% vs. 91.6%, p=1.0). In multivariate analysis using a Cox-regression model, the postoperative atrial dimension was an independent determinant of sinus conversion in the bipolar radiofrequency ablation group (hazard ratio 31, p=0.005). In the Cox-regression model for both groups, atrial fibrillation at 6 months postoperatively (hazard ratio 92.24, p=0.003) and the postoperative left atrial dimension (hazard ratio 16.05, p=0.019) were independent risk factors of continuance or recurrence of atrial fibrillation after Cox maze procedures. Aortic cross-clamp time and cardiopulmonary bypass time were significantly shorter in the radiofrequency group than in the cut-sew group. Conclusion: In the Cox maze procedure for patients with persistent atrial fibrillation, the use of bipolar radiofrequency ablation and a cryoablator is as good as the cut-sew technique for conversion to sinus rhythm. The postoperative left atrial dimension is an independent determinant of postoperative continuance and recurrence of atrial fibrillation.

Endoscopic Therapy for Pancreatic Benign Neoplasms (췌장 양성 종양의 내시경적 치료)

  • Hwang, Jun Seong;Ko, Sung Woo
    • Journal of Digestive Cancer Research
    • /
    • v.9 no.1
    • /
    • pp.25-32
    • /
    • 2021
  • Since Endoscopic ultrasound (EUS) was introduced in the 1980s, EUS has evolved from a diagnostic tool to a therapeutic modality for patients with pancreatic neoplasms. Traditionally, treatment policy of pancreatic benign neoplasms (PBN) has been a dichotomous approach to observation or surgery. However, EUS guided treatment provides an alternative option with minimally invasiveness for patients with PBN. This review aimed to provide the role of EUS guided treatment for PBN.

Pulsed Laser System of Ultra-scan Way for Uterus Rehabilitation Treatment (자궁 재활치료를 위한 울트라-스캔 방식의 펄스형 레이저시스템)

  • Kim, Whi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.256-265
    • /
    • 2009
  • Laser output becomes output adjustment from 20 w to 100 w consecutively and time of exposure is available adjustment through water plant in 0.01 seconds. Pulse action can intercept laser beam periodically and supermarket pulse 0.1 $\sim$ between 1ms discharge consist and momentary laser output is increased to 5 $\sim$ 10. Specially, that must remove malignancy cell in womb nine escarps in the case of uterine cancer first of all stability of tube output about pulse by weight very, stable soft switching action area is defined without high frequency transformer leakage inductance ($L_1$) increase and additional series inductor insertion to converter the first main circuit securing zero voltage and marks of switching action in this research specially, because circulation current path of inductor ($L_f$) current is intercepted, converter the first main circuit switching component and spiritual enlightenment damage of high frequency transformer take decreasing greatly and high frequency the second stoppage department ($D_5,\;D_6$) becomes soft switching, and also, switching damage absorption quantity characteristic that can come to life again as subordinate have, and to become tube stabilization design and result that manufacture and experiment, brought result that improve of 10% than existing equipment, and if supplement as systematic late, it becomes thought to get into superior result.

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF

Role of Endoscopic Ultrasound in the Assessment of Superficial Esophageal Cancer (조기 식도암에서 내시경초음파의 역할)

  • Cho, Yu Kyung
    • Korean Journal of Bronchoesophagology
    • /
    • v.17 no.1
    • /
    • pp.19-22
    • /
    • 2011
  • Endoscopic ultrasound in the diagnosis of esophageal carcinoma is an indispensable procedure, not only to discuss the preoperative staging of the lesion, but also to evaluate the therapeutic effect of chemo-radiation therapy. The recent increase in the incidence of superficial esophageal cancer and promising developments in potentially curative endoscopic therapies have placed EUS to a central position in decision making. Recent data have called into question the staging accuracy of EUS to distinguish mucosal from submucosal lesions, particularly in patients with early disease. In those cases, diagnostic endoscopic resection may be useful for staging and curative in superficial lesions. Nonetheless, EUS has been regarded as the most accurate staging tool and should be performed to identify potential candidates for endoscopic resection.

  • PDF

Assessment for the Temperature according to the Electrode Diameter of Radio Frequency Hyperthermia Using Agar Phantom (고주파 온열치료기의 전극의 직경에 따른 한천 팬톰의 온도분포 분석)

  • Lee, Yong Hee;Oh, Young Kee;Kim, Hwa Yeong;Jeon, Kyung Soo;Choi, Eun Cheol;Park, Seung Gyu;Kim, Ok Bae;Kim, Jin Hee
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • Hyperthermia is effective treatment modality when it combine with the radiotherapy treatment. It is important to verify the temperature distribution of (patient's) body for the safety and effective treatment during raising the temperature. In this study, we raised the temperature in agar phantom using radio frequency (RF) Hyperthermia and protocol that manufacture recommend. Temperature distribution measured 5 section of 5 cm thickness with agar phantom. When the temperature was raised according to the increase energy. Temperature distribution was elevated at similar domain regardless of energy. The temperature tend to be increased at up side then bottom side and also increase when A large electrode was used than small one.

Development of communcation signal interference removal module between High-Intensity Focused Ultrasound Devices using CAN communication (CAN 통신을 이용한 고강도 집속 초음파 디바이스간의 통신 신호 간섭 제거 모듈 개발)

  • Park, Jong-Cheol;Lee, Jin-Wook;Kim, Min-Sung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.463-465
    • /
    • 2022
  • The high-intensity focused ultrasound device intermittently operates abnormally due to communication signal interference between the devices during use due to the high frequency radiated during the skin treatment procedure. Communication interference between multi-frequency ultrasound devices can be reduced through CAN communication controller and transceiver design, firmware S/W program and CAN communication module development.

  • PDF

Clinical Study of Long Term Effect of Transvaginal Ultrasound Guided Radiofrequency Myolysis for Treatment of Uterine Leiomyoma (자궁근종 치료를 위한 질경유 초음파 유도하 고주파 자궁근종용해술의 장기간 효과에 대한 임상적 연구)

  • Lee, Woo-Seok;Lee, Il-Han;Kim, Dong-Ho;Lee, Sang-Hun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.35 no.1
    • /
    • pp.77-82
    • /
    • 2008
  • Objective: This study was performed to investigate the efficacy and safety of radiofrequency (RF) myolysis under transvaginal ultrasound guidance. Methods: Transvaginal RF myolysis had been performed in one hundred nine women with uterine leiomyoma at Chung-Ang University hospital between Dec. 2004 and Mar. 2007. All patients, mean aged $42.8{\pm}5.8$ years, desired their uterine conservation. Patients underwent physical examination, transvaginal pelvic ultrasound for measurement of the lesions preoperatively. Follow up was done at 1 week, 1 month, 3 months, 6 months after RF myolysis by same physician and measurement of size and volume of myoma and improvement of myoma specific symptoms such as menorrhagia and dysmenorrhea were checked at each visit. Results: The mean maximal diameter of myomas treated by RF myolysis was $6.1{\pm}0.5\;cm$ and average time of the procedure was $16.3{\pm}8.5$ minutes. A significant decrease of myoma size and volume was observed at 1 month after myolysis. Mean reduction in maximal diameter was $29.9{\pm}4.8%$ at 1 week (p<0.001), $41.5{\pm}1.5%$ at 1 month (p=0.05), $46.2{\pm}3.9%$ at 3 months (p=0.003), $54.6{\pm}6.1%$ at 6 months (p<0.001) after RF myolysis respectively. Mean reduction in volume was $44.4{\pm}8.3%$ (p=0.001), $68.1{\pm}4.2%$ (p=0.035), 73.9$73.9{\pm}4.8%$ (p=0.042), $84.5{\pm}5.1%$ (p<0.001) at the same follow up period respectively. Significant improvement of symptom was observed at 3 months after RF myolysis. Transient low abdominal pain and prolonged vaginal bleeding were detected in 3 patients each but spontaneously resolved and no serious complication has been noticed or found. Conclusion: This study shows transvaginal RF myolysis could be a safe and effective method to treat uterine leiomyoma, allowing uterine conservation with significant volume reduction and rapid return to normal activity.

음향공에 의한 LOX-RP1 고주파 음향-연소안정화에 관한 연구

  • 이길용;윤웅섭;조용호
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.5-5
    • /
    • 2000
  • 액체 추진 로켓 엔진의 고주파 연소 불안정 관련 이론은 대체로 연소기 내부의 음향 공명 모드와 분무 연소 과정의 상호 작용을 구동 메커니즘으로 전제하며 Rayleigh Criterion의 재해석에 기초하여 불안정성 평가를 위한 매개변수를 도입하고 연소 불안정성을 예측한다. 여기에는 음향장 분석 이론, 음향 불안정 이론, 연소응답 및 기화반응 이론 등이 포함된다. 본 연구에서는 LOX/RPl 추진제 조합의 액체 추진 로켓 엔진 연소기를 대상으로 다차원 순수 음향장 해석과 연소-음향장 분석을 통해 대상 엔진의 고주파 연소 불안정 특성을 예측하였다. 수동 제어 기기인 음향공 설치에 따른 연소기의 음향장 및 연소-음향장의 특성 변화를 고찰하고 위 결과를 종합하여 음향공의 연소 불안정 억제 성능 및 대상 엔진의 연소 불안정성을 평가하였다. 연소기 형상 및 음향공 설치에 따른 다차원 순수 음향장 해석은 상용코드인 ANSYS를 사용하여 수행하였다. 내부 유체는 압축성, 비점성 유체로 유체의 평균 유동은 무시하며 위치에 관계없이 균일한 물성치를 부여하였다. 정상상태 연소과정을 가정하고 평형 화학을 이용한 분석 결과로부터 연소 기체의 관련 물성치를 결정하였다. 연소기 길이 방향, 반경 방향, 원주 방향 격자점들의 음향 특성을 주파수 영역에 대해 해석하고 3차원 음향 모드 형상을 토대로 음향장을 분석하였다. 연소-음향장 해석은 음향 불안정 이론 중 n- $\tau$ 2 매개변수 기법을 사용하였다. 연료 액적의 분무 연소 과정을 1차원적으로 가정하고 정상상태의 평형 화학 계산 결과를 이용하여 엔진의 연소면을 1차원적으로 설정하였다. 상류 연소응답과 중립 안정 곡선을 토대로 대상 엔진의 연소 불안정 특성을 분석하였다.구 분석 결과 기술적 문제점으로는 배기 가스온도가 낮은데 따른 출구 부분의 Bearing, Sealing이 문제가 될 수 있다고 판단되며 배기 가스 자체에 대기 공기중에 함유되어 있던 습기가 얼어붙는(Icing화) 문제가 발생하기 때문에 배기가스의 Icing을 방지하기 위하여 압축기 끝단에서 공기를 추출하여 배기부분에 송출할 필요성이 있는 것으로 판단되었다. 출구가스의 기체 유동속도가 매우 빠르므로 (100-l10m.sec) 이를 완화하기 위한 디퓨저의 설계가 요구된다고 판단된다. 또 연소기 후방에 물을 주입하는 경우 열교환기 및 기타 부분품에 발생할 수 있는 부식 및 열교환 효율 저하도 간과할 수 없는 문제로 파악되었다. 이러한 기술적 문제가 적절히 해결되는 경우 비활성 가스 제너레이터는 민수용으로는 대형 빌딩, 산림, 유조선 등의 화재에 매우 적절히 사용되어 질 수 있을 뿐 아니라 군사적으로도 군사작전 중 및 공군 기지의 화재 그리고 지하벙커에 설치되어 있는 고급 첨단 군사 장비 등의 화재 뿐 아니라 대간첩작전 등에 효과적으로 활용될 수 있을 것으로 판단된다.가 작으며, 본 연소관에 충전된 RDX/AP계 추진제의 경우 추진제의 습기투과에 의한 추진제 물성 변화는 미미한 것으로 나타났다.의 향상으로, 음성개선에 효과적이라고 사료되었으며, 이 방법이 편측 성대마비 환자의 효과적인 음성개선의 치료방법의 하나로 응용될 수 있으리라 생각된다..7%), 혈액투석, 식도부분절제술 및 위루술·위회장문합술을 시행한 경우가 각 1례(2.9%)씩이었다. 13) 심각한 합병증은 9례(26.5%)에서 보였는데 그중 식도협착증이 6례(17.6%), 급성신부전증 1례(2.9%), 종격동기흉과 폐염이 병발한 경우와 폐염이 각 1례(2.9%)였다. 14)

  • PDF