• Title/Summary/Keyword: 고조파 왜곡

Search Result 170, Processing Time 0.028 seconds

Sinusoidal Current Control of Single-Phase PWM Converters under Voltage Source Distortion Using Composite Observer (왜곡된 전원 전압하에서 Composite 관측기를 이용한단상 PWM 컨버터의 정현파 전류 제어)

  • Nguyen, Thanh Hai;Lee, Dong-Choon;Lee, Suk-Gyu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.466-476
    • /
    • 2011
  • In this paper, a high-performance current control for the single-phase PWM converter under distorted source voltages is proposed using a composite observer. By applying the composite observer, the fundamental and high-order harmonic components of the source voltage and current are extracted without a delay. The extracted fundamental component is used for a phase-lock loop (PLL) system to detect the phase angle of the source voltage. A multi-PR (proportional-resonant) controller is employed to regulate the single-phase line current. The high-order harmonic components of the line current are easily eliminated, resulting in the sinusoidal line current. The simulation and experimental results have verified the validity of the proposed method.

Analysis of Volatage and Current Waveform Distortion Characteristics at Office Buildings (사무용 빌딩에서의 전압 및 전류파형 왜곡특성 분석)

  • Yoo, Jae-Geun;Lee, Sang-lck;Jeon, Jeong-Chay;Jeong, Jong-Wook;Lim, Young-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.155-161
    • /
    • 2005
  • Nonlinear electronic loads used at office buildings distort the voltage and current waveform that cause the overheating of transformer losses, ELB(Electrical Leakage Breaker) tripping, and so on. This paper analyzed waveform distortion characteristics at several once buildings by comparing with magnitude of voltage and current harmonics, crest factor of voltage and current, phase voltage and current unbalance. As a consequence, severe current waveform distortion in phase and neutral line by harmonics and high current unbalance rates by unbalanced using of single loads among the three phases are investigated. The results of the study can be used in making decisions regarding reasonable and economical operating of loads at office buildings.

Estimation of Nonlinear Distortion in Communication Systems Using Random Digital Signals (랜덤 디지탈 신호를 사용한 통신 시스템의 비선형 왜곡 추정)

  • 손주신;조용수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.4
    • /
    • pp.660-668
    • /
    • 1994
  • In this paper, a new approach to estimate nonmlinear distortions (second-harmonic, second-intermodulation, third-harmonic, and third-intermodulation) in digital communication systems is proposed. In contrast to the relatively common sine-wave input approach which requires repetition of the same experiments by changing frequencies of oscillators and filters over the band of frequencies of interest, the proposed approach uses digital random input (transmitted signal in digital communication system) to adaptively estimate parameters of a nonlinear channel in time-domain. Nonlinear distortion of the channel is estimated on line by transforming the estimated parameters into frequency-domain. Comparison between the classical two-tone input approach and the proposed approach is made through computer simulation.

  • PDF

A Study on the Harmonic Characteristics of GHP Cooling/Heating Load in an Institutional Building (교육용 건물의 GHP 냉/난방 부하의 고조파 특성에 관한 연구)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Lee, Kyu-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.29-38
    • /
    • 2009
  • The GHP(Gas Heat Pump) is an efficient cooling;11eating system in which a compressor is driven by a gas engine and is brodening its application to the facilities such as schools and office buildings. It is difficult to control the GHP system because of slow response, big time constant and time variant system. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probability approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the GHP loads, harmonic assessment by me 61000-3-2, and harmonic simulation and harmonic filter application using EDSA program for the case study system.

A Predistortion Linearizer Using the In-phase Modulator (동 위상 변조기를 이용한 전치왜곡 선형화기)

  • Kim, Eel-Kou;Jeon, Ki-Kyung;Kim, Young;Youn, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.1
    • /
    • pp.41-47
    • /
    • 2006
  • In this paper, a predistortion linearizer using the in-phase modulator is proposed. The harmonic generator of the proposed predistorter extracts a second harmonic signals. These signals are divided in-phase and quadrature-phase signals, and then amplifying each signals using variable gain amplifier. An in-phase modulator, modulate fundamental signal with second harmonic signals, generates the predistortion intermodulation distortion (IM) signals and controls amplitude and phase of them with modulation factors. As a result, this predistorter is suppressed intermodulation distortion signals of power amplifier effectively. The proposed linearizer has been implemented to operate in Cellular-band. The test results show that the third order IM is cancelled more than 20dB in case of CW 2-tone signals with ${\Delta}f$=1MHz. Also, it's improved the adjacent channel power ratio (ACPR) more than 7dB for IS-95 CDMA 1FA signals.

  • PDF

Phase Lacked Loop for Grid-Connected Three phase Inverter (계통연계 분산전원을 위한 Phase Lacked loop)

  • Kim Y. S.;Ahn K. S.;Park S. Y.;Lim L. C.;Oh J. M.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.172-176
    • /
    • 2005
  • Phase Lacked Loop(PLL)은 분산전원을 계통연계시 동기설정을 위해 중요한 장비이다. 이러한 동기설정은 Point of Common Coupling(PCC)에서 계통 전압을 검출하여 크기와 위상을 동일하게 설정하여 전력변환장치에서 전력을 출력한다. 일반적으로 PCC에서 계통전압을 검출하였을 때 고조파, 상간불평형은 전력변환장치 출력 왜곡을 야기 시킨다. 본 논문에서는 이러한 출력왜곡을 감소시키기 위한 3상 PLL을 모델링하여, 그 제어 성능을 시뮬레이션을 통해 확인하였다.

  • PDF

Multiresonant Sliding Mode Control Scheme to Improve Power Quality of LCL filtered Grid-connected Inverter (계통연계 인버터의 전력품질 개선을 위한 다중 공진제어 기반 슬라이딩모드 제어기법)

  • Yoon, Seung-Jin;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.378-379
    • /
    • 2019
  • 본 논문은 LCL 필터를 사용하는 3상 계통연계 인버터의 그리드 전류 오차를 개선하고 고조파 왜곡 현상을 억제하기 위해 다중 공진제어 기법을 슬라이딩 평면에 적용한 슬라이딩 제어기(SMC)를 제시한다. 일반적으로 시스템 파라미터가 변경되거나 계통에 외란이 발생할 경우 슬라이딩 평면이 표류하는 현상이 나타나며 이러한 표류 현상은 시스템 정상상태 오차와 시스템에 고조파 왜곡 현상을 일으키고 계통연계 인버터의 전류 품질에 심각한 영향을 미치게 된다. 이러한 현상을 해결하기 위해 적분 함수가 추가된 SMC가 제안되었으나 해당 제어기는 효과적으로 정상상태 오차를 제거하는 반면 슬라이딩 평면의 표류현상을 충분히 줄여주지 못하는 한계를 가지고 있다. 이러한 정상상태 오차와 표류현상을 제거하기 위해 다중 공진제어 조건을 슬라이딩 평면 함수에 추가한 제어기를 제시한다.

  • PDF

A Study on the Harmonics Measurement and Assessment of the Electrolyzer Loads (전해조 부하의 고조파 측정 및 평가에 관한 연구)

  • Kim, Kyung-Chul;Lee, Joo-Hong;Jin, Seong-Eun;Park, Sang-Young;Lee, Il-Moo;Jeon, Young-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.29-37
    • /
    • 2006
  • Heavy chemical industries have nonlinear loads including elecrolyzers. AC-DC converters are the most widely used in an elecrolysis in a chemical plant. The electrolysis consists of AC-DC converter groups connected in parallel at the DC side. The converter operations cause harmonic currents and create distortions on the sinusoidal voltage of the AC power system. This paper provides an in depth analysis on harmonics field measurement for the electrolyzer loads and harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE 519-1992.

Design of a Bias Circuit for Reducing Memory Effects (Memory Effect를 줄이기 위한 바이어스 회로의 설계)

  • Kang, Sanggee
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.4
    • /
    • pp.115-119
    • /
    • 2017
  • Intermodulation distortion degrades the S/N(signal-to-noise) of the original signal and also affects the adjacent channels. Intermodulation distortion is mainly caused by the nonlinear characteristics of the power amplifier. If the power amplifier with nonlinear characteristics has a memory effect, the intermodulation distortions occurred in the power amplifier are generated in various and complex forms. The predistorter is used as a way to improve intermodulation distortions. In order to efficiently utilize the performance of the predistorter, the memory effect of the power amplifier must be reduced. In this paper, we describe the design method of bias circuit to reduce the memory effect in power amplifiers. To reduce the memory effect, the bias circuit must have a high impedance for the signal and a low impedance for the envelope(modulating signal) and the second harmonic component of the signal. To verify the performance of the bias circuit designed considering the memory effect, a power amplifier operating at 170 ~ 220MHz was designed and implemented. The designed bias circuit has a large impedance in the operating frequency band and low impedance in the envelope signal and the second harmonic of the signal. As a result of the performance measurement, it was found that the asymmetric intermodulation distortion component is improved by 3.7dB.

A novel energy-efficient bridgeless boost AC to DC converter (효율을 고려한 새로운 AC/DC 컨버터)

  • Yoon, Kyoung-Kuk;Kim, Seong-Hwan;Kim, Deok-Ki
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.223-227
    • /
    • 2016
  • Power supplies make the load compatible with its power source. DC power supplies are extensively used with most electrical and electronic appliances such as computers, television, and audio sets. The presence of non-linear loads results in a low power factor and higher harmonics in the power system. Several techniques for power-factor correction and harmonic reduction have been reported in the literature. This paper proposes a bridgeless boost converter that improves the power factor and reduces the harmonic content in input line currents as compared to full-bridge rectifiers. This bridgeless boost converter eliminates the need of a line-voltage bridge rectifier in conventional boost converter and thereby reduces conduction losses. The effectiveness of the proposed scheme is verified by computer simulations by using the PSIM software.