• Title/Summary/Keyword: 고정원

Search Result 1,493, Processing Time 0.05 seconds

Design of Phase Locking Loopfilter Using Sampling Phase Detector for Ku-Band Dielectric Resonator Oscillator (Ku-대역 유전체 공진기 발진기의 Sampling Phase Detector를 이용한 위상 고정 루프 필터 설계 및 제작)

  • Badamgarav, O.;Yang, Seong-Sik;Oh, Hyun-Seok;Lee, Man-Hee;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.10
    • /
    • pp.1147-1158
    • /
    • 2008
  • In this paper, we designed a phase-looking circuit that locks the 16.8 GHz VTDRO to a 700 MHz SAW oscillator using SPD as a phase detector Direct phase locking with loop filter alone causes the problem of lock time, so VTDRO is phase leered by loop filter with the aid of time varying square wave current generator. The current generator is related to the loop filter and needs the systematic toning. In this paper, a systematic design of the current generator and loop filter is presented. The fabricated PLDRO shows a stabilized frequency of 16.8 GHz, a output power 6.3 dBm, and a phase noise of -101 dBc/Hz at the 100 kHz offset.

Mechanical Alignment of Hull Mounted Phased Array Radar on the Separated Mast (분리된 마스트에 설치되는 선체고정 위상 배열 레이더의 기계적 정렬)

  • Seo, Hyeong-Pil;Kim, Dae-Han;Kim, Joon-Woo;Lee, Kyung-Jin;Cho, Kyu-Lyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.465-473
    • /
    • 2019
  • This paper is meaningful as the first case where a 4 - sided hull-fixed phased array radar was installed on a mast separated from Korea and the alignment was verified. The mechanical alignment method was studied for accurately mounting two separate masts for naval ships and the 3D scanner for alignment. Hull-fixed phased array radar uses very high frequency, so the short wavelength can cause a phase difference of the device due to the small positional error. Since the array antenna is fixed with the hull, it has higher accuracy control than the rotary radar for 4 array surfaces. The study describes a method of checking the flatness of two radar masts manufactured at a factory, a method of aligning masts in a shipyard, and a method of aligning four array pad mounting surfaces. As a tool for this, a 3D laser scanner and a software-based method for comparing survey results with 3D CAD are used. This paper is meaningful as the first example of installing a four-sided hull-fixed phased array radar on a separate mast from a Korean naval ship and deriving a mechanical alignment method.

A study on the Changes in the water level-flow relationship curve due to the operation of movable beams and the influence of construction (가동보 운영과 공사영향에 의한 수위-유량 관계곡선식의 변화)

  • Ok, Young Jun;Jo, Kyung Min;Lee, Jung Hoon;Kim, Seung Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.421-421
    • /
    • 2022
  • 만경강 유역은 우리나라의 농업지역 중 하나로 많은 농업용수를 필요로 하는 지역으로 농업용수 공급을 위하여 다수의 취입보가 설치되어 있으며, 충분한 농업용수 확보를 위하여 다른 지역과 달리 가동보와 고정보가 병설로 설치되어 있는 곳이 많다. 통상적인 가동보는 농업용수 확보와 공급을 위하여 농번기인 4월~9월까지 운영되는 것이 일반적이며, 이러한 가동보 운영으로 인하여 다양한 수위-유량관계의 변동성이 발생한다. '20년부터 전주천에 위치한 취입보는 과거와 달리 기존의 월류 높이가 높은 보의 형태에서 어도가 넓고, 보의 높이가 낮은 친환경 월류보의 형태로 전환이 이루어지고 있으며, 그 영향으로 인하여 과거의 수위-유량관계와는 상이한 결과가 발생한다. 하도의 변동성은 단면 측량 등으로 확인 할 수 있으나, 가동보 운영과 공사와 같이 통제특성에 의한 변동사항이 발생하는 경우 모니터링이 필수적이다. 본 연구에서는 만경강 유역에 위치한 전주시(미산교)관측소를 대상관측소로 선정하였으며, 대상관측소는 '20년 12월~'22년 1월까지 친환경 월류보 전환을 위하여 가동보 운영과 공사가 진행된 관측소이다. '20년 12월 친환경 월류보 형태의 전환을 위하여 가동보 운영을 시작하였으며, '21년은 1월~3월은 유지유량을 위한 가동보 운영을 실시하였으며, 4월~9월은 농업용수 확보를 위한 가동보 운영을 실시하였고, 10월~12월은 하도 내 공사 진행에 따라 가동보와 고정보를 같이 운영하였다. 이 기간동안 가동보와 고정보 모니터링을 실시하였으며, 정확한 유량측정성과와 곡선식 확인을 위하여 동일한 위치에서 측정을 수행하였다. 가동보 운영과 공사영향 모니터링 결과와 유량측정성과를 바탕으로 수위-유량관계 변화를 분석하였으며, 저수위 구간은 가동보 운영에 따라 총 11차례 기간분리가 발생하였으며, 중수위 구간도 가동보 운영으로 인하여 과거와 상이한 경향이 발생하여 곡선식을 재개발 하였다. 결과적으로 본 연구에서는 가동보 운영에 따른 다수의 유량측정성과를 확보하였으며, 확보한 유량측정성과의 분석을 통한 신뢰도 높은 수위-유량관계곡선식을 개발하였고 이를 통해 생산된 유량자료는 정확도가 매우 높은 것으로 분석되었다.

  • PDF

Influence of immediate loading on the removal torque value of mini-screws (교정력의 즉시 부하가 미니스크류의 제거 회전력에 미치는 영향의 평가)

  • Sun, Seung-Bum;Kang, Yoon-Goo;Kim, Seung-Hun;Mo, Sung-Seo;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.400-406
    • /
    • 2007
  • The purpose of this experimental study was to evaluate the effect of immediate orthodontic loading on the stability at the bone-implant interface of titanium miniscrews in a rabbit model. Methods: Forty titanium miniscrews (1.6 mm diameter, 8 mm length) were inserted in the tibiae of 10 rabbits. Twenty test group miniscrews were subjected to continuous orthodontic forces of 200g immediately after implantation for a period of 6 weeks. The remaining 20 control group miniscrews were left unloaded for the same follow-up interval. Removal torque values were recorded using a digital torque gauge. An independent t-test was performed. Results: All the miniscrews were stable, and exhibited no mobility or displacement throughout the experimental period. Histologically, miniscrews were well-integrated into bone. No statistically significant differences in removal torque data were found between the loaded test and the unloaded control groups. Conclusions: These findings suggest that titanium miniscrews can be used as anchoring units for orthodontic tooth movement immediately after insertion.

Comparison of the fatigue limit of fiber-reinforced composites and stainless steel wires when attached to the tooth surface for anchorage reinforcement (고정원 강화를 위해 치면에 부착한 fiber-reinforced composite과 스테인리스강 와이어의 피로한도 비교)

  • Kim, Moon-Jung;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.302-311
    • /
    • 2005
  • This study was performed to compare the fatigue limit of stainless steel wires and Fiber-reinforced composites (FRC) under conditions of permitting physiologic tooth movement. and to evaluate the clinical value of FRCs which was used to reinforce the anchorage unit. The stainless steel wire groups were divided into round and rectangular wire groups. The FRC groups were divided into uni-directional and woven groups, with resin coating and without resin coating in the Proximal area After the number of cycles to failure of each of the 6 groups were measured within the $5{\times}10^5\;cycle$ fatigue limit simulating the orthodontic treatment period. the fatigue limit of each group was compared with each other The findings of this study were as follows. In stainless steel wires, the fatigue limit of rectangular wires were higher than that of round wires. But there was no statistically significant difference (p>0.05). In FRCs with resin coating and without resin coating in the interproximal area, the fatigue limit of uni-directional type was higher than that of the woven type (p<0.05). In uni-directional and woven type FRCs, the fatigue limit of FRC with resin coating in the interproximal area was higher thar that of FRC without resin coating (P<0.05) As the FRCs and stainless steel wires did not fracture until the $5{\times}10^5\;cycle$ fatigue limit which clinically is useful. it is sufficient to use FRC and stainless steel wire for reinforcing anchorage. When esthetics is important and the attachment of additional devices are necessary. it seems sufficient to use FRC as anchorage reinforcement.

A comparison of on masse retraction of six anterior teeth with separate canine retraction (6전치 일괄(on masse) 견인과 견치 견인 후 4전치 견인 시 공간폐쇄 양상에 관한 연구)

  • Heo, Wook;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.32 no.3 s.92
    • /
    • pp.165-174
    • /
    • 2002
  • The purpose of this study was to compare on masse retraction of six anterior teeth with separate canine retraction in the amount of the anchorage loss and the retraction of the anterior teeth. The subjects consisted of 30 adult female patients with Angle Class 1 malocclusions who were treated by .022' straight wire appliance with 4 first permolar extraction. They were composed of two groups. Group 1 consisted of 15 subjects, whose six anterior teeth were retracted by on masse retraction. Group 2 consisted of 15 subjects, whose canines were retracted separately. Pre-treatment and post-treatment lateral cephalometric radiographs were analyzed. All data were processed statistically with independent samples t-test, and the conclusions were as follows. 1. There was no significant difference in the amount of the anchorage loss between two groups(p>0.05). 2. There was no significant difference in the amount of the retraction of the anterior teeth between two groups(p>0.05). 3. There was a significant difference in the amount of the inclinational change of the upper incisors between two groups. It was greater in Group 2. 4. There was a significant difference in the vertical positional change of the upper incisal edges between two groups. The upper incisal edges in Group 2 were more extruded than Group 1 by about 1mm. 5. There was no significant difference in the vertical positional change of the root apex of the upper incisors between two groups(p>0.05). And there was no significant difference in the vertical positional change of the upper molar(p>0.05).

Orthodontic intrusion treatment of mandibular anterior teeth in a periodontal patient with hyperdivergent skeletal pattern: 8-year follow-up (장안모를 보이는 치주 질환자에서 하악 전치의 압하를 통한 과개 교합 치료: 8년 경과 관찰)

  • Kwon, Eun-Young;Jung, Kyung-Hwa;Park, Soo-Byung;Kim, Seong-sik;Kim, Yong-il;Choi, Youn-kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.1
    • /
    • pp.48-60
    • /
    • 2021
  • Patients who have extruded anterior teeth and deep bite with pathologic tooth migration, it is necessary not only periodontal treatment for reduce inflammation, but also orthodontic treatment for intrusion of anterior teeth. However, it is difficult to place the orthodontic brackets due to the deep bite, and there is a problem that the extrusion of the posterior teeth occurs more easily than the intrusion of the anterior teeth biomechanically. In particular, in patients with long face, relative intrusion of the anterior teeth by extrusion of the posterior teeth causes the clockwise rotation of the mandible and makes the facial profile worse. Therefore the biomechanical consideration and appliance design that can block these problems are required from the treatment plan. This is a patient who had a deep overbite with extruded anterior teeth, treated by periodontal treatment and intrusion of mandibular anterior teeth using cute brackes and miniscrews, and resulted in favorable maintenance during 8-year retention.

An Study on flow Discharge Calculation using Surface Velocity (비접촉식 유속계의 표면유속을 이용한 유량산정방법에 관한 연구)

  • Roh, Youngsin;Lee, Sin Jae;Kim, Dae Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.230-230
    • /
    • 2020
  • 하천 유량측정을 위한 표면유속계는 비접촉식 방식이기 때문에 현장에서의 측정이 간편하고, 비교적 안전하기 때문에 홍수시 유량측정에 널리 이용되고 있다. 비접촉식 유속계가 가지고 있는 이러한 장점으로 전자파표면유속계의 활용이 점차 증가하고 있으며, 영상유속계와 같은 비접촉 측정방식의 활용방안 마련에 대한 연구개발 등이 꾸준히 진행되어 왔다. 최근에는 고정식으로 상시 운영이 가능한 표면유속계 등이 출시되어 소규모 하천이나 수로에서의 상시 유량측정에 활용되고 있다. 다만, 이러한 비접촉식 유속계는 표면의 유속을 측정하기 때문에 유량산정을 위해서는 평균유속으로의 환산이 필요하지만, 현재까지는 평균유속 환산계수를 사용하여 표면유속을 평균유속으로 환산하는 방법이 유일하게 활용되고 있다. 하지만, 실제 하천에서는 단면 및 하도형태, 하상조건, 수리특성 및 유속분포 등의 다양한 조건에 따라 환산계수가 결정되기 때문에 이를 단순히 일률적으로 적용하는 것은 곤란하며, 이로 인해 과거 오랫동안 표면유속을 평균유속으로 환산하기 위한 다양한 연구가 진행되었지만, 실제 다양한 조건의 하천에 적용할 수 있는 표준화된 방법은 아직까지 제시되지 못하고 있다. 현재까지, 고정식으로 설치된 유속계로부터 측정된 유속을 평균유속으로 환산하는 방법으로는 국내외적으로 지표유속법(Index Velocity Method)과 유속분포법(Velocity Profile Method)이 대표적이며, H-ADCP (Horizontal-Acoustic Doppler Velocity Profiler) 또는 UVM(Ultrasonic Velocity Meter) 등과 같은 초음파유속계를 활용한 자동유량측정시설의 유량산정방법으로 활용되고 있다. 이러한 방법들은 고정된 유속계의 측정유속을 지표유속(Vi)으로 하여 다양한 범위의 실측된 평균유속과의 관계를 개발하여 활용하거나, 지표유속을 매개로 개수로 단면의 이론적인 유속분포를 추정하여 평균유속을 산정한다. 이러한 지표유속을 활용하는 방법들에서 공통적으로 중요한 것은 하천단면의 최대유속(Vmax)이 가장 좋은 지표유속이라는 것이다. 따라서 국제기준에서는 지표유속을 측정하는 유속계의 가장 바람직한 위치로 유심부(core flow)를 권장하고 있다. 하지만, 접촉식 유속계의 경우 유심부 설치가 매우 어렵고 많은 비용이 들기 때문에, 비접촉식 유속계를 활용하여 하천단면의 최대유속을 측정할 수 있다면, 가장 효율적인 고정식 측정방법이 될 수 있을 것이다. 따라서, 본 연구에서는 비접촉식 표면유속계의 고정식 유량측정 활용성 및 적용성을 검토할 목적으로 표면유속에 대한 유량산정방법을 검토하였다. 이를 위해 24GHz의 주파수를 갖는 레이다표면유속계인 Sensoflow를 낙동강 수계 길안천에 위치한 안동시(대사3교)에 고정설치하여 표면유속을 지표유속으로 수집하였다. 다양한 유량규모에서 측정한 실측 표면유속과 수집된 표면유속을 지표유속으로 활용하여 지표유속관계를 개발하였으며, 산정된 유량을 기존 수위-유량관계곡선식의 환산유량과 비교하여 표면유속의 지표유속 활용성을 검토하였다.

  • PDF

Parallel Operation of Voltage Source Inverters by Using Stator Windings of High Power Three-Phase Induction Motors (대전력 3상 유도전동기의 고정자권선을 이용한 전압원 인버터의 병렬운전)

  • Kim B. K.;Moon S. H.;Kang S. K.;Kim I. D.;Nho E. C.;Jeon S. J.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.327-330
    • /
    • 2001
  • 본 논문에서는 고압 대전력 3상 유도전동기의 고정자 권선을 이용한 전압원 인버터의 병렬운전 방식을 제안한다. 현재 사용되고 있는 대부분의 4극 이상 대전력 유도전동기는 각 상의 권선이 외부에서 접근이 가능하도록 외부단자가 설치되어 있으며, 이들 외부단자를 이용하여 복수대의 전압원 인버터를 병렬운전하여 대전력 유도전동기를 구동할 수 있다. 이와 같이 고압 대전력 유도전동기를 복수 개의 전압원 인버터를 병렬 운전하여 구동할 경우, 특정 인버터의 고장발생 시 비록 구동 토크는 감소될지라도, 나머지 인버터로 시스템을 계속 구동할 수 있어 시스템의 고장대처능력을 향상시킬 수 있다. 또한 병렬 운전되고 있는 각 인버터의 스위칭 동작에 대해 서로 위상 차를 갖게 함으로서, 등가 스위칭 주파수를 증가시켜 출력 토크 리플 감소와 입력 전류 리플 감소, DC Link 커패시터의 크기 감소와 같은 좋은 특성을 얻을 수 있다. 또한 각 인버터로의 전력의 분산에 의해 시스템에서 발생하는 EMI 영향을 감소시킬 수 있다. 본 논문에서는 제안한 방식을 컴퓨터 시뮬레이션을 통해 특성을 증명하였다.

  • PDF

PEG에 고정화된 Pseudomonas aeruginosa를 이용한 NH$_4$-N, NO$_3$-N 동시제거에 관한 연구

  • Park, Gyeong-Hun;Jeong, Gyeong-Hun;Choe, Hyeong-Il;Song, Won-Jong;Gang, Yeong-Ju
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.503-506
    • /
    • 2008
  • 질소제거 능력이 있는 Pseudomonas aeruginosa을 고분자물질인 PEG 에 포괄고정화하였으며 제조된 고정화 미생물을 이용하여 질소제거에 미치는 C/N비, 농도, 충진율, 탄소별 제거율을 검토한 결과 다음과 같은 결론을 얻었다. 1) C/N비 10이상이면 NH$_4$-N 와 NO$_3$-N의 동시 제거가 가능하였으며 2) 탄소 원으로는 glucose를 사용하였을 때 NH$_4$-N 와 NO$_3$-N의 동시 제거가 가능하였으나 methanol은 탄소원으로 사용할 수 없었다. 3) 저농도의 NO$_3$-N(50 mg/L)는 완전히 제거 가능하였으나 NH$_5$-N인 경우에는 초기 NH$_4$-N 100 mg/L에서 60%정도만 제거되었다. 4) 연속처리 결과 NH$_4$-N는 HRT 변동에도 불구하고 유출수 농도 변화가 거의 없었으나, 오히려 C/N비를 증가시키면 NH$_4$-N 제거 효율이 높았고, NO$_3$-N인 경우도 마찬가지로 C/N비를 증가시키면 NO$_3$-N 제거 효율이 높았다.

  • PDF