• Title/Summary/Keyword: 고정빔

Search Result 174, Processing Time 0.024 seconds

Fast liquid crystal switching performance on indium zinc oxide films with low curing temperature via ion-beam irradiation (이온빔 조사된 저온 소성 인듐 아연 산화막을 이용한 액정의 고속 스위칭 특성 연구)

  • Oh, Byeong-Yun
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.904-909
    • /
    • 2019
  • Using the ion-beam irradiated indium zinc oxide (IZO) films which was cured at $100^{\circ}C$, uniform LC and homogeneous alignment of liquid crystal (LC) molecules was achieved. The IZO film was deposited on the glass substrate at the curing temperature of $100^{\circ}C$ and irradiated by the ion-beam which is an LC alignment method. To verify the LC alignment characteristics, polarizing optical microscope and the crystal rotation method were used. Additionally, it was confirmed that the LC cell with the IZO films had an enough thermal budget for high-quality LC applications. Field emission scanning electron microscope was conducted as a surface analysis to evaluate the effect of the ion-beam irradiation on the IZO films. Through this, it was revealed that the ion-beam irradiation induced rough surface with anisotropic characteristics. Finally, electro-optical (EO) performances of the twisted-nematic cells with the IZO films were collected and it was confirmed that this cell had better EO performances than the conventional rubbed polyimide. Furthermore, the polar anchoring energy was measured and a suitable value for stable LC device operation was achieved.

A Comprehensive Dosimetric Analysis of Inverse Planned Intensity Modulated Radiation Therapy and Multistatic Fields Technique for Left Breast Radiotherapy (좌측 유방 방사선치료를 위한 역치료계획의 세기변조방사선치료와 다중빔조사영역치료기법 사이의 포괄적 선량측정 분석)

  • Moon, Sung-Kwon;Youn, Seon-Min
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.39-49
    • /
    • 2010
  • Purpose: This aim of this study is to analyze the dosimetric difference between intensity-modulated radiation therapy (IMRT) using 3 or 5 beams and MSF in the radiotherapy of the left breast. Materials and Methods: We performed a comparative analysis of two radiotherapy modalities that can achieve improved dose homogeneity. First is the multistatic fields technique that simultaneously uses both major and minor irradiation fields. The other is IMRT, which employs 3 or 5 beams using a fixed multileaf collimator. We designed treatment plans for 16 early left breast cancer patients who had taken breast conservation surgery and radiotherapy, and analyzed them from a dosimetric standpoint. Results: For the mean values of $V_{95}$ and dose homogeneity index, no statistically significant difference was observed among the three therapies. Extreme hot spots receiving over 110% of the prescribed dose were not found in any of the three methods. A Tukey test performed on IMRT showed a significantly larger increase in exposure dose to the ipsilateral lung and heart than multistatic fields technique (MSF) in the low-dose area, but in the high-dose area, MSF showed a slight increase. Conclusion: In order to improve dose homogeneity, the application of MSF, which can be easily planned and applied more widely, is considered an optimal alternative to IMRT for radiotherapy of early left breast cancer.

Ultra Wide Area Wireless Backhaul Network System Based on Large Scale Array Antenna (대형 어레이 안테나 기반 초광역 무선 백홀망 시스템)

  • Go, SeongWon;Kim, Hyoji;Lee, Ju Yong;Cho, Dong-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.7
    • /
    • pp.1354-1362
    • /
    • 2015
  • Heterogeneous network technology is expected to be a core technology for 5G mobile communications. 5G mobile network would be composed of many base stations even have mobility, then the operator should connect base stations through the wireless backhaul technology. This paper presents Ultra Wide Area Wireless Backhaul Network System with massive array antenna. We conducted link budget analysis for Ultra Wide Area Wireless Backhaul Network and performance analysis of massive array antenna system through the transmission simulator based on beamforming technology. In wide area ($10km^2$) wireless backhaul system composed of massive antenna, we achieved 5 bps/Hz average spectral efficiency with 1 W transmission power per beam.

폐암 세기변조방사선치료 시 최적화된 조사계획 설정과 가상 장기 설정에 관한 연구

  • Lee, Seok;Lee, Chang-Geol;Cho, Sam-Ju;Chu, Sung-Sil;Lee, Sang-Hoon;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.34-34
    • /
    • 2003
  • 목적 : 폐암 환자 세기변조방사선치료 과정을 소개하고, 방사선치료계획의 최적화를 위한 빔 수와 방향, 가상장기 설정 (virtual organ delineation, VOD) 및 선량 제한 인자들의 이용에 대해 평가함으로써 폐, 심장 등에 조사되는 선량을 최소화하는데 사용하는 세기변조방사선치료 (intensity modulated radiotherapy, IMRT) 기술의 유용성을 평가하고자한다. 대상 및 방법 : 종양이 종격동을 침범하여 상대적으로 장기움직임에 의한 오차가 적은 폐암환자 5 명을 대상으로 하였다. 환자고정장치는 상반신을 편안하게 유지함과 동시에 팔의 위치를 고정시킴으로써 기대할 수 있는 환자고정효과와 벨트를 이용하여 환자 상복부를 압박해줌으로써 호흡운동에 의한 장기 움직임을 감소시킬 수 있는 형태로 고안하였다. 치료계획시 빔 수와 방향은 5,7,9 문 (from 200 to 160, equispaced field, arbitrary field), 4 문 (anterior, posterior, bilateral posterior oblique field) 과 비등방 7, 9 문 (non-equispaced field, arbitrary field) 등을 사용하였다. 선량제한 ($V_{20}V_{25}$)은 문헌에 기초하여 설정하였으며, 가상장기를 적절히 사용하여 최적화된 치료계획 결과를 얻었다. 방사선치료계획 평가는 선량-체적간 히스토그람 (DVH), 등선량곡선 및 선량통계 등을 이용하여 수행하였다. 특히 가상장기 설정 전, 후의 결과 값을 분석함으로써 그 유용성을 확인하였다. 결과 : 9문 등방-IMRT와 7문 비등방-IMRT 방법이 치료계획용적의 선량균질성 (PTV dose homogeneity), 평균 폐선량 (mean lung dose) 및 $V_{20}V_{25}$ 모두에서 20% 이내의 좋은 결과를 얻을 수 있었고, 가상 장기를 설정함으로써 같은 결과를 가져옴을 알 수 있었다. 또한 폐암 세기변조방사선치료 프로토콜을 작성하여 임상에 사용함으로써 치료과정 중 발생할 수 있는 오류를 보완할 수 있음을 알 수 있었다. 결론 : 폐암 세기변조방사선치료 시 사용할 수 있는 프로토콜을 작성하였고, 적절한 가상 장기 및 조사계획 설정으로 치료계획의 최적화를 얻을 수 있음을 알 수 있었다.

  • PDF

Design of Downlink Beamforming Transmitter in OFDMA/ TDD system (OFDMA/TDD 시스템의 하향링크 빔형성 송신기 설계)

  • Park Hyeong-Sook;Park Youn-Ok;Kim Cheol-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.5A
    • /
    • pp.493-500
    • /
    • 2006
  • This paper presents the efficient structure and parameter optimization of downlink beamforming transmitter in OFDMA/TDD system. To design downlink beamforming transmitter for multiple transmit antennas, an efficient beamforming structure for multiple users and the choice of word-length of each block are critical in the aspect of its performance and hardware complexity. We propose an efficient beamforming scheme, which stores the weights of subcarriers into memory without user identification at the receiver of base station and calculates the weights for corresponding user in a subcarrier unit of IFFT input at high speed. Also, we obtain the word-length of main data path and other design parameters by fixed-point simulation analysis. The proposed architecture could reduce the memory size proportional to the maximum number of users per frame, and the processing time of an OFDM symbol at the receiver of base station without the need of additional processing time for calculating the weights at the transmitter.

Array Gain Improvement of Triple Line Array System Using Inverse Beamforming (역 빔형성기를 이용한 3중 선배열 시스템에서의 어레이 이득향상)

  • 오효성;강성현;김의준;고정태;김용득
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.5
    • /
    • pp.786-795
    • /
    • 1999
  • To detect the precise of arrival of target signal in real ocean environments, Inverse beamformnig(IBF) solutions to the Inverse beamforming integral equation are surveyed theoretically and the performance properties of the IBF are analyzed with simulations. IBF-Cardioid beamforming algorithm is proposed for port/starboard discrimination and the performance gains are studied with simulations. It is shown that IBF has a 3 dB array noise gain advantage over CBF under ideal conditions. This 3 dB array noise gain advantage is proven by theocratical studies and simulations. This array noise gain advantage leads to a minimum detectable level advantage for IBF output compared with CBF output. The fact that the IBF beamwidth is narrower than the CBF beamwidth by a factor of 0.68 proves the performance of detection and spatial resolution improvement. Comparing the simulation results of IBF-Cardioid beamforming and Conventional Cardioid beamforming, it is shown that IBF-Cardioid beamformer have performance enhancement in minimum detection level, detection accuracy and resolution.

  • PDF

이온 조사에 따른 전도성 고분자의 Photoluminescecne (PL) 변화 연구

  • 이철수;주진수;고석근
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.200-200
    • /
    • 1999
  • ^g , pp V (Poly-para phenylene vinylene) 유도체와^g , pp P(Poly-para phennylene) 유도체에 Ar, H2, N2 및 O2 등의 이온을 조사하여 PL(Photoluminescence)의 변화를 실험하였다. 각각의 전도성 고분자는 ITO9indium tin oxide)가 증착되어 있는 유리기판위에 spin coating을 하였으며 이렇게 처리된 전도성 고분자의 표면에 이온을 조사하였다. 여기에서 조사된 이온의 가속 에너지는 300eV에서 700eV까지 변화시켰고 이온 조사량은 1$\times$1013ions/cm2에서 1$\times$1017ions/cm2까지 변화시켰다. 이때 이온빔의 전류밀도는 0.2$\mu\textrm{A}$/$\textrm{cm}^2$이하로 고정하였으며 chamber내의 진공도는 $1.5\times$10-4Torr를 유지하였다. 이온 빔처리후 불안정한 고분자의 표면이 대기와 반응하는 것을 어느정도 방지하기 위해 이온 빔으로 처리된 시료를 chamber의 내부에 일정시간동안 방치하였다. Ar, H등의 이온으로 처리된 MEH-PPV의 경우는 PL의 세기가 감소하였고 이온 조사량이 1016ions/cm2 보다 클 때 PL의 세기는 급속히 감소하였다.^g , pp V와^g , pp P 유도체의 경우는 특정 이온 조사량에서 PL의 증가현상을 보였는데^g , pp P 도체중에서 P3의 경우를 보면 이온 빔 에너지가 300eV이고 이온 전류 밀도가 0.05$\mu\textrm{A}$/$\textrm{cm}^2$인 N2이온을 조사하면 이온 조사량이 1$\times$1013ions/cm2가 될 때 PL의 세기가 39%까지 증가하였다. PL의 변화에 대한 비교를 위해 이온빔으로 처리된 시료와 처리되지 않은 시료의 UV흡수스펙트럼과 IR 흡수 스펙트럼을 분석하였다. 본 실험에 사용된 모든 시료의 PL 세기는 1016ons/cm2이상의 dose에서 급격한 감소 현상을 나타내었고 PL의 최대값을 나타내는 파장의 이동은 관찰되지 않았다.

  • PDF

Optical signal amplification property in photorefractive Cu-KNSBN crystal (광굴절 Cu-KNSBN 결정에서의 광신호 증폭 특성)

  • Kim, Sung-Gu;An, Jun-Won;Kim, Nam;Lee, Kwon-Yeon;Seo, Ho-Hyung
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.288-289
    • /
    • 2000
  • SBN, BSKNN KNSBN 등의 tungsten-bronze 계열에 속하는 광굴절 결정은 짧은 파장에서 좋은 감광도와 빠른 응답시간을 갖는다. 이중에서도 KNSBN 결정은 큰 크기의 결정 성장 및 도핑이 용이하고 광굴절 결정에서 중요한 특성 중 하나인 열 안정성(thermal stability)이 좋기 때문에 빠른 응답특성이 요구되는 응용분야에서 촉망받는 매질이다. 본 논문에서는 광정보저장, 광정보처리, 광컴퓨터, 광통신과 같은 다양한 분야에서 응용가능성을 가지는 Cu가 0.04wt.%도핑된 5mm$\times$5mm$\times$5mm 크기의 KNSBN 결정을 이용한 광신호의 증폭기술에 대하여 연구하였다. 먼저 Cu-KNSNB 결정의 2광파 결합 특성을 분석하기 위하여, 기록 파장에 따른 지수이득계수의 외부입사각의존성, 최대 지수이득계수를 나타내는 외부입사각에서 입사빔의 세기비에 따른 2광파 결합 이득을 측정하였다. 또한, 632.8nm파장 영역에서 기록 및 삭제시간 상수, 회절 효율의 입사빔 세기비 의존성을 측정하였다. 그리고, 음향-광학 변조기(AOM: acousto-optic modulator)에 의해 진폭 변조된 신호빔을 이용하여 광신호 증폭특성을 분석하고 그 결과를 제시하였다. 이때 두 빔의 입사각은 최대 지수이득계수를 나타내는 입사반각 12$^{\circ}$로 고정하고, 감쇄기를 이용하여 신호빔의 세기를 조절하면서 신호빔의 차동이득을 측정하였다. 투과된 신호빔은 같은 주파수에서 차동 이득(diffrerential gain)을 보였으며, 이는 moving grating과 시간-변조된 신호빔(또는 펌프빔)사이의 새로운 상호작용은 광굴절 결정의 시간 적분 특성에 의한 것이다. (중략) 경우는 상온에서 펌프 펄스의 유지시간이 0.5% 인 경우 레이저가 동작하는 것을 보여주었다. 이는 구조내에서 열전도가 문제가 된다는 것을 의미하는데 위아래가 공기로 둘러 싸여 있어 발생한 열이 가는 유전체 네트웍을 통해서만 전달 될 수 있기 때문이다. (중략)$^4$A$_2$에 의한 nophonon line R$_1$, R$_2$(680.4, 678.5 nm) 및 $^2$T$_1$$\longrightarrow$$^4$A$_2$(655.7, 649.3, 645.2 nm)의 형광방출 스펙트럼을 얻었으며, 형광수명은 0.264 ms로 조사되었다. 제조된 레이저 발진봉은 직경 6.3 m, 길이 45 nm이었다.\pm$0.06kHz Ge $F_4$; -1.84$\pm$0.04kHz$0.04kHz/TEX>0.04kHz 모국어 및 관련 외국어의 음운규칙만 알면 어느 학습대상 외국어에라도 적용할 수 있는 보편성을 지니는 것으로 사료된다.없다. 그렇다면 겹의문사를 [-wh]의리를 지 닌 의문사의 병렬로 분석할 수 없다. 예를 들어 누구누구를 [주구-이-ν가] [누구누구-이- ν가]로부터 생성되었다고 볼 수 없다. 그러므로 [-wh] 겹의문사는 복수 의미를 지닐 수 없 다. 그러면 단수 의미는 어떻게 생성되는가\ulcorner 본 논문에서는 표면적 형태에도 불구하고 [-wh]의미의 겹의문사는 병렬적 관계의 합성어가 아니라 내부구조를 지니지 않은 단순한 단어(minimal $X^{0}$ elements)로 가정한다.

  • PDF

Implementation of real-time free-space optical interconnection using spatial light modulator (공간광변조기를 이용한 실시간 자유공간 광연결 구현)

  • Lee, Deug-Ju;Kang, Bong-Gyun;Kim, Nam;Suh, Ho-Hyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.5
    • /
    • pp.956-966
    • /
    • 1997
  • Dynamic free-space optical interconnection system is experimented by a holographic crossbar with single-state switching architecture. For dynamic operation, electrically addressed liquid-crystal spatial light modulator and diffraction gratings are used in place of passive holograms of matrix-matrix crossbar. Diffraction gratings are consisted of regular cells which have different phase delays. This pixelated phase grating array displayed on SLM(Spatial Light modulator) deflects an input beam toward a wanted direction or splits an input beam into many beams and then steers them to desired positions. Through the experimental results, free-space optical interconnection is dynamically perfomed using a computer, SLM and phase diffraction gratings.

  • PDF

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF