• Title/Summary/Keyword: 고정도 가속도계

Search Result 19, Processing Time 0.018 seconds

Estimation of Energy Expenditure using Unfixed Accelerometer during Exercise (비고정식 가속도계를 이용한 운동 중 에너지소비 추정)

  • Kim, Joo-Han;Lee, Jeon;Lee, Hee-Young;Kim, Young-Ho;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.63-70
    • /
    • 2011
  • In this paper, we proposed a method for estimating energy expenditure using the unfixed axis of the accelerometer. Most studies adopted waist-placement because of the fact that the waist is close to the center of mass of a whole human body. But we adopted pocket-placement, which is capable of using unfixed axis of sensor, that is more convenient than conventional methods. To evaluate the proposed method, 28 male subjects performed walking and running on a motor driven treadmill. All of subject put on the indirect calorimeter and fixed accelerometer, then data were simultaneously measured during exercise. The regression analysis was performed using the test group(n=20) and the regression equation was applied to the control group(n=8). A strong linear relationship between energy expenditure and unfixed accelerometer signal was found. Futhermore, the coefficient of determination was significantly reliable($R^2$=0.98) and showed zero of p-value. The error of energy expenditure estimation between indirect calorimeter and two types of accelerometer was 15.0%(fixed) and 17.0%(unfixed) respectively. These results show the possibilities that the unfixed accelerometer can be used in estimating the energy expenditure during exercise.

Application of High-precision Accelerometer Made in Korea to Health Monitoring of Civil Infrastructures (국산 고정밀 가속도계의 건설 구조물 적용성 평가)

  • Kwon, Nam-Yeol;Kang, Doo-Young;Sohn, Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.3
    • /
    • pp.277-283
    • /
    • 2016
  • A high-precision force-feedback 3-axes accelerometer developed in Korea has been investigated and studied for the verification of feasibility in the computational analysis and health monitoring of civil infrastructures. Through a series of experiment, the nonlinearity, bandwidth, low-frequency signal measurement accuracy and bias characteristics of the accelerometer has been thoroughly compared to those of two accelerometers produced by two market leaders in domestic and global accelerometer market. The experiment results shows that the overall measurement performance of the accelerometer has superiority over the performance of the two accelerometers from global market leader companies. Especially, the accelerometer shows a better low-frequency signal measurement accuracy and constant bias characteristic, which are mostly required in the computational analysis and the long-term health monitoring of large-scale civil infrastructures.

Study on Measurements of the In-Plane Vibration Intensity In a Beam With a Damped End (감쇠 단을 갖는 보의 면내 진동인텐시티 측정에 관한 연구)

  • Kim Chang-Yeol;Kil Hyun-Gwon;Hong Suk-Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.7
    • /
    • pp.371-378
    • /
    • 2005
  • The objective or this paper is to measure the in-plane vibration intensity of a beam with a damped end that means the magnitude and direction of vibration power. Three experimental methods have been implemented to measure the in-plane vibration intensity over the beam. The first method is the accelerometer array method using two accelerometers. The second method is the frequency response function method using the only one accelerometer. The third method is the reference accelerometer method using a fixed reference accelerometer and another moving accelerometer. Those methods have been used to measure the spatial distribution of in-plane vibration intensity over the beam. The results obtained with those methods have been compared with each other. The results have been compared with an input power. It showed that the frequency response function method and the reference accelerometer method as well as the accelerometer array method can be effectively used to measure the in-plane vibration intensity in beams.

Study for Dynamic Characteristics of the Accelerometer Mounting Fixtures (가속도계 고정기구의 동특성에 대한 연구)

  • Lee, Jong-Kyu;Kim, Sung-Boo;Lee, Doo-Hee;Bae, Dong-Myung;Shin, Chang-Hyuk;Cho, Seung-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.4 s.121
    • /
    • pp.350-355
    • /
    • 2007
  • Accelerometer mounting fixtures were prepared with the different materials(Ti and SUS). The dynamic characteristics of the mounting fixture were analyzed by finite element method(FEM), and the mode shape of each order and the displacement response for modelling the mounting fixture were analyzed by ANSYS, then resonant frequencies of the mounting fixtures with Ti and SUS were 22.700 and 23.390 kHz, respectively. The dynamic characteristics of the mounting fixture with the different positions were obtained by using laser interferometer. The response of the accelerometer was nearly a constant from 40 Hz to 500 Hz, but the change of the acceleration was increased with an increase of the frequency above 500 Hz.

A High Resolution Capacitive Single-Silicon Microaccelerometer using High Amplitude Sense Voltage for Application to Personal Information System (고 감지 전압을 이용한 개인 정보기기용 고정도 정전용량형 단결성 실리콘 가속도계)

  • Han, Ki-Ho;Cho, Young-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.53-58
    • /
    • 2001
  • This paper presents a high resolution capacitive microaccelerometer for applications to personal information systems. We reduce the mechanical noise level of the microaccelerometer by increasing the proof-mass based on deep RIE process. We reduce the electrical noise level by increasing the amplitude of an AC sense voltage. The high sense voltage is obtained by DC-to-DC voltage multiplier. In order to solve the nonlinearity problem caused by the high sense voltage, we modify the conventional comb electrode of straight finger type into that of branched finger type, resulting in self force-balancing effects for enhanced detection linearity. The proposed branched finger capacitive microaccelerometer was fabricated by the deep RIE process of an SOI wafer. The fabricated microaccelerometer reduces the electrical noise at the level of $2.4{\mu}g/\sqrt{Hz}$ for the sense voltage of l6.5V, which is 10.1 times smaller than the electrical noise level of $24.3{\mu}g/\sqrt{Hz}$ at 0.9V. For the sense voltage higher than 2V, the electrical noise level of the microaccelerometer became smaller than the constant mechanical noise level of $11{\mu}g/\sqrt{Hz}$. Total noise level, including the electrical noise and the mechanical noise, has been measured as $9{\mu}g/\sqrt{Hz}$ for the sense voltage of 16.5V, which is 3.2 times smaller than the total noise of $28.6{\mu}g/\sqrt{Hz}$ for the sense voltage of 0.9V. The self force-balancing effect results in the increased stiffness of 1.98 N/m at the sense voltage of 17.8V, compared to the stiffness of 1.35 N/m at 0V, thereby generating the additional stiffness at the rate of $0.002N/m/V^{2}$.

  • PDF

A Short-term Dynamic Displacement Estimation Method for Civil Infrastructures (사회기반 건설구조물의 단기 동적변위 산정기법)

  • Choi, Jaemook;Chung, Junyeon;Koo, Gunhee;Kim, Kiyoung;Sohn, Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.3
    • /
    • pp.249-254
    • /
    • 2017
  • The paper presents a new short-term dynamic displacement estimation method based on an acceleration and a geophone sensor. The proposed method combines acceleration and velocity measurements through a real time data fusion algorithm based on Kalman filter. The proposed method can estimate the displacement of a structure without displacement sensors, which is typically difficult to be applied to earthquake or fire sites due to their requirement of a fixed rigid support. The proposed method double-integrates the acceleration measurement recursively, and corrects an accumulated integration error based on the velocity measurement, The performance of the proposed method was verified by a lab-scale test, in which displacement estimated by the proposed method are compared to a reference displacement measured by laser doppler vibrometer (LDV).

Application of the fiber-optic lattice fence systems for the electric power system significant building safety monitoring (전력 System 시설물 안전 감시용 광섬유 격자 그물망 구현을 위한 광섬유 시스템 적용성 연구)

  • Lee, Cheol-Kyou;Park, Yoon-Suk;Lee, Jong-Kil;Lee, June-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1861-1863
    • /
    • 2001
  • 본 연구에서는 국내에서도 아직 초기단계 기술이라고 할 수 있는 간섭계를 이용한 주요 시설물(변전소등) 안전 감시 혹은 항만 감시 및 방어용 광섬유 격자 그물망 구현을 위한 광섬유 시스템 적용성을 연구한 것이다. 연구에서는 마흐젠더 간섭계의 구성에 비해 구성이 용이한 Sagnac간섭계를 구성 실험하였다. 이 간섭계의 성능 검증을 위하여 1550nm의 중심파장을 방사하는 레이저, 싱글모드 광섬유, 3${\times}$3 커플러 등의 광소자를 사용하였고, 광섬유의 길이의 변화를 주기 위하여 PZT 위상 변조기에 교류 전원을 인가하여 PZT 위상 변조기의 진동을 유도하였다. 또한, 전체 길이 약 180cm, 17${\times}$7, 철봉의 직경 6m의 철망 구조물을 제작후, 센서 부분의 역할을 담당한 광섬유 케이블을 일정한 간격으로 철망 구조물에 케이블 타이로 고정하였다. 철망 구조물에서 발생할 수 있는 각종 외부 가진에 대해, 철망 구조물에 가속도계를 설치하여, Sagnac 간섭계에서의 광 간섭 신호와 가속도계의 신호를 비교 검증 하였다. 본 실험결과를 통하여 광섬유 펜스는 주요 시설물(변전소등) 안전 감시 혹은 항만 감시 및 방어용 경보 시스템에 적합하다고 판단된다.

  • PDF

High-resolution Capacitive Microaccelerometers using Branched finger Electrodes with High-Amplitude Sense Voltage (고감지전압 및 가지전극을 이용한 고정도 정전용량형 미소가속도계)

  • 한기호;조영호
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • This paper presents a navigation garde capacitive microaccelerometer, whose low-noise high-resolution detection capability is achieved by a new electrode design based on a high-amplitude anti-phase sense voltage. We reduce the mechanical noise of the microaccelerometer to the level of 5.5$\mu\textrm{g}$/(equation omitted) by increasing the proof-mass based on deep RIE process of an SOI wafer. We reduce the electrical noise as low as 0.6$\mu\textrm{g}$/(equation omitted) by using an anti-phase high-amplitude square-wave sense voltage of 19V. The nonlinearity problem caused by the high-amplitude sense voltage is solved by a new electrode design of branched finger type. Combined use of the branched finger electrode and high-amplitude sense voltage generates self force-balancing effects, resulting in an 140% increase of the bandwidth from 726㎐ to 1,734㎐. For a fixed sense voltage of 10V, the total noise is measured as 2.6$\mu\textrm{g}$/(equation omitted) at the air pressure of 3.9torr, which is the 51% of the total noise of 5.1$\mu\textrm{g}$/(equation omitted) at the atmospheric pressure. From the excitation test using 1g, 10㎐ sinusoidal acceleration, the signal-to-noise ratio of the fabricated microaccelerometer is measured as 105㏈, which is equivalent to the noise level of 5.7$\mu\textrm{g}$/(equation omitted). The sensitivity and linearity of the branched finger capacitive microaccelerometer are measured as 0.638V/g and 0.044%, respectively.

Comparison vibration characteristics of several wireless endodontic handpieces (여러 근관치료용 무선 핸드피스의 진동양상 비교)

  • Lee, Bo-Kyung;Lee, Yoon;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.2
    • /
    • pp.81-89
    • /
    • 2022
  • Purpose: Wireless endodontic handpieces (WEH) are widely used in dental clinics due to their convenience and portability. This study aimed to compare the vibration magnitudes and patterns generated by five WEH. Materials and Methods: Vibration acceleration of five WEH (X-Smart IQ, E connect S, Endo A Class, ENDOIT, and TRAUS ENDO) in the rotary and reciprocating motion was measured with accelerometer The average vibration acceleration was analyzed using the t-test, Welch's ANOVA test, and Dunnett T3 test at P < 0.05. Results: In all WEH, the average vibration acceleration in reciprocating motion was significantly higher than that in rotary motion (P < 0.001). In rotary motion, repeated vibration graphs of constant amplitude were obtained without sudden changes in the magnitude of vibration, and the average vibration acceleration value was high in the order of X Smart IQ, Endo A Class, ENDOIT, E Connect S, and TRAUS ENDO (P < 0.001), there was no statistically significant difference between X Smart IQ and Endo A Class. In reciprocating motion, a vibration graph was obtained in which large amplitude peaks appear at specific points within one cycle are repeated. The average vibration acceleration value was highest in the order of X Smart IQ, E Connect S, Endo A class, ENDOIT, and TRAUS ENDO (P < 0.001). Conclusion: Regardless of the type of WEH, greater vibration occurred in the reciprocating motion than in the rotary motion (P < 0.001). In the reciprocating motion, there was a difference in vibration for all handpieces (P < 0.001).

Acceleration Amplification Analysis according to Changes in Laminar Shear Box Boundary Conditions (연성토조의 경계조건 변화에 따른 가속도 증폭 분석)

  • Jeong, Sugeun;Jin, Yong;Park, Kyungho;Kim, Daehyeon
    • The Journal of Engineering Geology
    • /
    • v.32 no.1
    • /
    • pp.143-155
    • /
    • 2022
  • In this study, the response acceleration amplification according to different conditions was analyzed by changing the boundary condition of the soil called LSB (Laminar Shear Box), which is placed on a 1 g shaking table for earthquake simulation experiments. Experiments were carried out with different boundary conditions by fixing both sides of the LSB, and two samples were tested by installing an accelerometer at the same location. In addition, using DEEPSOIL v7 program, a one-dimensional ground response analysis was performed to compare and analyze with the free field condition. As a result, it was confirmed that the acceleration was amplified as it went from the lower layer to the upper layer, and as a result of comparing it with the ground response analysis, it was confirmed that it appeared similar to the analysis under the free field condition. As a result of the SA (Spectrum acceleration) analysis, a result similar to that of the ground response analysis was obtained, and in the case of fixing, it was confirmed that the PSA (Peak Spectral Acceleration) was further amplified.