Algorithm of Detecting Ground Fault by Using Insulation Monitoring Device(IMD) in Ungrounded DC System (직류 비접지계통에서 절연저항측정장치(IMD)를 이용한 사고검출 알고리즘)

  • Kim, Ki-Young;Lee, Hu-Dong;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.528-535
    • /
    • 2020
  • Recently, the protection coordination method of DC systems has been presented because renewable energy and distributed resources are being installed and operated in distribution systems. On the other hand, it is difficult to detect ground faults because there is no significant difference compared to a steady-state current in ungrounded IT systems, such as DC load networks and urban railways. Therefore, this paper formulates the detection principle of IMD (Insulation Monitoring Device) to use it as a protection coordination device in a DC system. Based on the signal injection method of IMD, which is analyzed by a wavelet transform, this paper presents an algorithm of detecting ground faults in a DC system in a fast and accurate manner. In addition, this paper modeled an IMD and an ungrounded DC system using the PSCAD/EMTDC S/W and performed numerical analysis of a wavelet transform with the Matlab S/W. The simulation results of a ground fault case in an ungrounded DC system showed that the proposed algorithm and modeling are useful and practical tools for detecting a ground fault in a DC system.

Preventing marine organisms adhesion by oil-infused PDMS (오일이 주입된 PDMS를 이용한 해양생물의 부착방지 방법에 대한 고찰)

  • Kim, Su-Yeong;Yun, Yeong-Cheol;Im, Chae-Gang;Jeong, Yong-Chan;Lee, Su-Yeol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.45-45
    • /
    • 2018
  • 홍합, 따개비 등의 접착성 해양생물은 선박의 하부나 발전소 해수 공급용 튜브에 부착하여 운영 효율을 저하 시키고, 냉각기기 고장을 유발하는 파울링(Fouling) 문제를 야기시킨다. 일반적으로 이러한 문제에 대응하기 위해서 초접착성 해양생물이 주로 부착하는 부위에 $Cu_2O$, ZnO 등을 포함한 유기화합물로 표면처리를 하여 부착방지를 하고 있지만, 이 소재들을 장시간 사용 시 해양 오염 및 부식을 가속화하는 문제를 초례하기 때문에 최근에는 사용을 금지하고 있다. 이러한 유해성 소재 문제를 해결하고자 친환경적이고 부작용이 없는 초접착성 해양생물 부착방지 소재를 개발하고자 하였다. 본 연구에서는 낮은 표면장력을 갖는 PDMS(Polydimethylsiloxane) 소재를 기반으로 소수성 oil을 침투시킨 I-PDMS(Oil-Polydimethylsiloxane) 표면처리법을 고안하였고, 이 방법을 활용하여 초접착성 해양생물에 대한 부착방지 성능을 향상시키고자 하였다. 기존의 개발품들 보다 성능이 향상된 I-PDMS 제조하고자, Nano-indentation을 이용한 기계적 특성 평가, X컷 및 cross-cut을 이용한 부착력 평가, 실제 바다환경에서 해양생물의 부착력 시험, 바다 환경을 모사한 수조에서의 I-PDMS와 비교군 기판에서의 홍합 거동, 홍합과 기판의 접착강도 시험, 해양 미생물 평가를 실시하였으며, 이를 통해서 I-PDMS 성능 및 내구성을 입증하고자 하였다.

  • PDF

Effects of Intragastric Hypertonic Solution on Pancreatic Exocrine Secretion (고장수액의 위내 주입으로 인한 취외분비의 변동)

  • Cho, T.S.;Kim, W.J.;Hong, S.S.
    • The Korean Journal of Pharmacology
    • /
    • v.13 no.1 s.21
    • /
    • pp.29-33
    • /
    • 1977
  • Effects of 50% glucose solution on pancreatic exocrine function were studied in rat, rabbit and cat. The alterations during the resting state, the continuous intravenous infusion of secretin and the infusion of secretin with CCK-PZ were determined. 1) No change of pancreatic secretion in rat was observed by intragastric administration of the hypertonic glucose solution. 2) Intragastric administration of the hypertonic glucose solution in rabbit produced the inhibitory effect on pancreatic secretion during secretion infusion. 3) While secretin with CCK-PZ were infused continuously, intragastric administration of the hypertonic glucose solution revealed the marked inhibitory effect on pancrcreatic secretion in cat. Oral administration of the hypertonic glucose solution produced no significant inhibition in the resting gland but markedly depressed the pancreatic flow and enzyme concentration in the secretin or CCK-PZ stimulated gland. It is felt that the inhibitory response of exocrine pancreas induced by intragastric hytertonic glucose solution is resulted in interaction between secretory hormone and gastric mucosal factor possibly enteroglucagon.

  • PDF

Finite Element Analysis for Insulation Design of Rectangular Busbar with the Electrical Tree (전기 트리를 가지는 사각 버스바의 절연 설계에 관한 유한요소해석)

  • Jeon, Jun-Young;Rho, Tae-Woo;Jo, Sung-Man;Kim, Sang-Min;Oh, Jong-Seok;CHOI, Jungwan;Suh, Jae-Hak
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.205-206
    • /
    • 2015
  • 케이블 및 버스바는 전원을 공급하는 부대 장치로 산업 전반에 걸쳐 널리 사용되고 있다. 대부분의 경우 일정 주기로 점검 및 교체 등의 유지 보수를 진행하나 ITER IVC 버스바 및 지중케이블 등의 특수한 경우에서는 접근성 및 작업성의 이유로 유지 보수를 진행 할 수 없다. 이러한 경우, 절연물 내부에 전기 트리가 발생했을 때에는 대책이 없다. 전기 트리는 부분적인 고전계에 의한 진성파괴, 전하의 주입 또는 추출에 의한 파괴 및 전기-기계적 응력(맥스웰 응력)에 의한 파괴, 미소 부분 방전에 의한 파괴의 가장 큰 고장요인이 되는 현상이며, 다양한 사고 사례가 알려져 있다. 본 연구에서는 유한요소해석법을 이용하여 전기 트리를 가지는 사각 버스바에 대한 전계해석을 진행하였고, 전기 트리를 방지 할 수 있는 사각 버스바의 절연 설계에 대한 방안을 제시한다. 이 설계 방안은 향후 전기 트리를 고려한 사각 버스바의 절연 설계 기초 데이터로 활용 될 것이다.

  • PDF

Field Applicability Assessment of Degradation Diagnosis System for Distribution Power Cables (배전케이블 열화진단 장치의 현장적용성 평가)

  • Lee, Jae-Bong;Kim, Dong-Myung;Song, Il-Keun;Kim, Ju-Yong;Kim, Suk-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1131-1134
    • /
    • 2003
  • 이 논문은 현재 국내에서 사용하고 있는 배전용 케이블 열화진단장치인 완화전류 측정장치의 진단기준 개선을 위한 것이다. 현재까지 사용되던 직류 고전압을 이용한 누설전류 측정법을 대체하기 위해 사용되는 완화전류 측정장치는 국내 배전선로에서 수년간 현장적용을 실시하여 많은 케이블을 교체하였다. 하지만 완화전류 측정을 통해 교체한 케이블의 상태에 대해서는 검증되지 않은 상태이므로 완화전류 측정을 통한 교체기준이 국내 케이블에 적절한지 확인할 필요가 있다. 이는 케이블 유지보수에 있어서 중요한 사항으로서 교체기준이 부적절할 경우 열화진단을 통한 고장방지 목적을 달성할 수 없거나 건전한 케이블을 교체하여 불필요한 예산을 낭비하는 원인이 된다. 본 논문에서는 현장운전중인 선로를 선택하고 열화된 케이블의 절연성능 향상을 위해 실리콘을 주입하였다. 그리고 실리콘 처리후 케이블의 운전시간에 따른 열화진단 결과와 케이블 절연파괴강도를 비교하여 진단장치의 신뢰성을 검증하고자 하였다. 이것은 1년 동안의 현장시험 결과를 정리한 것이다.

  • PDF

Indirect Current Control of Utility Interactive Inverter for Seamless Transfer (연속적인 운전모드의 전환을 위한 계통연계형 인버터의 간접 전류 제어기법)

  • Yu, Tae-Sik;Bae, Young-Sang;Kim, Hyo-Sung;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.72-78
    • /
    • 2006
  • Distributed generation (DG) systems go to intentional islanding operation to back up private emergency loads when the main grid is out of electric power. Conventional utility interactive inverters normally operated in current control mode in DG system must change their operation mode into voltage control mode to ensure stable voltage source to the emergency loads when intentional islanding operation occurs. During the transfer between current control mode and voltage control mode, serious transient problem may occur on the output terminal voltage of the utility interactive inverter. This paper proposes reasonal inverter topology and its control algorithm for seamless transfer of DG systems in intentional islanding operation. Filter design guide line and data for a LCL filter that is appropriate for the proposed control algorithm are also presented by the authors.

A study on the Removal of Heavy Metals from Industrial Wastewater by Treatment with Discarded Automotive Tires (폐 타이어에 의한 고장폐수 내의 중금속 제거에 관한 연구)

  • Choung, Youn Kyoo;Min, Dal Ki;Oh, Hyun Je
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.6 no.4
    • /
    • pp.29-42
    • /
    • 1986
  • This study is an experimental research on the adsorption capacity and the adsorption system utilizing Discarded Automotive Tires(DAT) and Powdered or Granular Activated Carbon(PAC or GAC) for the removal of heavy metals, Ag(I), Cd(II), Cu(II), Zn(II). Batch shaking test was conducted to determine the adsorption capacity of DA T and PAC in removing the heavy metals from aqueous wastes; and laboratory-scale column experiment was performed to present design factors affecting the optimum design of adsorption column with DAT and GAC, through the concept of Bed Deph/Service Time(BDST). As results, DAT has been proven to be a good adsorbent will its adsorption capacity not falling behind PAC or GAC. Factors affecting heavy metals removals were amount of adsorbents, initial concentrations, pH and so on. BDST equations were compared with values presented by the breakthrough data from adsorption system.

  • PDF

Electronical Property of BSCCO Tube Fabricated by Centrifugal Melting Process (원심 용융 성형공정으로 제조된 BSCCO 튜브의 전기적 특성)

  • Choi, Jung-Suk;Oh, Sung-Young;Jun, Byung-Hyuk;Kim, He-Lim;Hyun, Ok-Bae;Kim, Hyoung-Seop;Kim, Chan-Joong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.267-267
    • /
    • 2006
  • 전력에 큰 손실을 초래하는 고장전류를 차단하기 위한 한류기(FCL) 소재로서 고온 초전도체인 BSCCO 2212가 사용된다. 고온에서 용융된 BSCCO 2212 분말은 원심성형법에 의해 한류기용 튜브로 제조되었다. BSCCO 튜브의 기계적 특성을 높이고 용융온도를 낮추기 위해 $SrSO_4$(10wt-%)를 첨가하였다. 용탕은 $1200^{\circ}C$에서 완전히 용융되어 금속 몰드로 주입되었고 원심성형에 사용되는 금속 몰드는 $550^{\circ}C$ 온도로 2시간 예열 후 1020 ~ 2520 RPM으로 회전시켰다. 원심력에 의해 성형된 BSCCO 튜브는 약 48시간 동안 로에서 서냉 후 금속 몰드로부터 분리하였다. 튜브의 용이한 분리를 위해 이형제로서 BSCCO 2212 powder를 사용하였고 임계전류측정을 고려하여 Ag tape 단자를 튜브 끝단에 부착하였다. BSCCO 제조 공정에 있어서 몰드의 예열온도, 용융온도, 몰드 회전속도 등의 변수를 조절하여 최적의 조건을 확립하였다. 제조한 BSCCO 튜브의 임계전류($I_c$)와 임계전류밀도($J_c$)는 77K에서 536A와 $205A/cm^2$ 이었다. 본 연구에서는 BSCCO 2212 튜브를 제조하는 공정조건 변화와 각 조건에서 제조된 BSCCO 2212 튜브의 전기적 특성 및 그에 따른 분석에 대해 기술하였다.

  • PDF

Investigation of Plume Opacity Induced by the Combustion of Orimulsion (오리멀젼 연소로 인한 가시백연의 원인 규명)

  • Kim, Young-Hun;Kim, Jong-Ho;Joo, Ji-Bong;Lee, Jeong-Jin;Kim, Jin-Soo;Kwak, Byung-Kyu;Jeong, Jin-Heun;Park, Soong-Keun;Yi, Jong-Heop
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.297-303
    • /
    • 2007
  • Orimulsion, a bitumen-in-water emulsified fuel, has been used throughout the world as a substitute fuel for heavy oil and coal. Orimulsion has relatively high levels of sulfur, nickel, and vanadium, compared to other fuel oils and coals, and has been the subject of much debate regarding the environmental impacts. In Korea, Y power plant has operated boilers with Orimulsion as a fuel, and they has some drawbacks during the plant operation, such as plume opacity. In this study, we investigated the cause of formation mechanism and factors for the plume opacity by investigating the operation data, and measuring the particle size distribution at EP(Electrostatic Precipitator), FGD(Fuel Gas Desulfurization) and TMS(Telecommunications Management System) units. Resulting data showed the primary particles below 1 ${\mu}m$ formed were regrown by the recombination of $SO_3$ in wet-limestone FGD process, and thus the secondary particles are induced to cause the plume opacity.

鐵鋼 溶接部의 균열發生과 그 試驗方法

  • 김영식
    • Journal of Welding and Joining
    • /
    • v.4 no.3
    • /
    • pp.13-25
    • /
    • 1986
  • 철강 구조물의 용접기술에 있어 용접부의 신속성을 좌우하는 가장 중요한 요소는 용접균열에 관한 문제와 용접본드부의 취화에 관한 문제로 요약될 수 있다. 일반적으로 용접부 및 그 근방의 금속은 국부적으로 매우 높은 온도까지 급열된 후 급냉되므로, 용접부에서 각종균열의 발성 위험성이 높아지고 용접본드부를 취화하여 파양인성의 저하를 초래하게 된다. 따라서 이러한 문 제점을 극복하기 위해서는 재료의 선택이나 설계, 시공, 검사의 각 단계에서 충분한 검토가 필 요하다. 특히 최근 들어 이전보다 높은 강도의 고장력강재가 널리 사용되고 구조물의 대형화에 따라 구속조건이 증대되며 구조물의 사용 조건은 더욱 가혹 화함에 따라 상술한 문제점은 더욱 중요시되고 있다. 철강 용접부에 발생하는 균열은 용접시공시 발생되는 균열과 용접완료후 구 조물 사용중에 발생되는 균열로 대별될 수 있다. 용접시공중 발생되는 균열은 용접열싸이클로 인해 생성되는 조직, 석출물등의 치금학적 요인과 잔유응력 또는 구속응력등의 역학적 요인이 중첩됨으로서 발생된다. 또한 사용중 발생되는 균열은 상기의 두 가지 요인이외에 환경적 요인이 첨가되어 발생된다고 볼 수 있다. 이상과 같은 용접균열을 방지하기 위해서는 실 구조물 용접 조립시의 각종 조건을 재현한 시험법을 통해 용접균열 발생의 한계조건을 정량적으로 분석할 필요가 있다. 이러한 균열 시험의 결과, 적정한 용접 시공 조건이 도출될 수 있기 때문이다. 이와 같은 필요성에 의해 지금까지 다수의 용접균열 시험법에 관한 연구가 행하여져 왔고 그 중에는 각 국가의 협회나 학회의 규격으로 확립된 것도 많으며 국제규격으로 되어 있는 것도 있다. 본 고에서는 각종균열들에 대한 지금까지 밝혀진 기구들에 대해 해설하고, 그 각각에 적용되고 있는 시험법들에 대해 소개하고저 한다.C1지구의 공업.생활용수는 103units, 33units로 배분되고, 하류지구에 304units로 배분되었다. 따라서 용도별로 물배분하므로서 금호강 하루지역에 더욱 많은 물을 배분할 수 있음을 알았다.통해서 수위-유량관계(rating curve)를 규명하였다. 시험지구의 관개효율 및 용수손실 규명 등에 관한 기본자료를 수집하기 위해서는 계측시스템의 운영은 장기간으로 지속 되어야 한다며, 전기전도도와 토양수 농도, 전기전도도와 함수량의 관계를 이용한 천이상태의 오염원 농도 측정방법을 개발하였다. 특히 제안식에서는 한계함수량의 개념을 도입하여 전기전도도와 함수량관계를 추정하므로 추정식의 실험값 반영 정도를 증가시켰다. 본 연구에서 제안된 식을 이용하여 추정된 전기전도도와 함수량관계는 다른 제안식에 비하여 개선된 결과를 보여 주었고, 본 연구에서 개발한 오염원 농도 측정법을 이용하여 측정한 결과 함수량이 0.15이하에서는 측정오차가 크지만 함수량이 0.15이상일 경우 매우 좋은 결과를 보였는데 질량평형을 검토한 결과 약 5-10%의 오차율을 보였다. 따라서 본 논문에서 개발된 천이상태의 오염원 농도측정법은 용존 오염물질의 이송에 관한 정확한 실험을 제공할 것으로 판단된다.며, 수질 보전적-환경 보전 차원에서 저수관리 체계를 확고히 할 수 있는 방안을 강구하여야 할 것이다.펄스주입법에 의해 증착된 박박은 강유전성 이력을 나타내었다.지역과 비도시지역을 비교하는 조사 연구가 필요하며, 이러한 조사결과를 바탕으로 자녀의 식습관에 대한 교육을 위한 교재, 교구의 개발과 영양, 식습관 교육프로그램의 개발을 통해 가정과 학교에서 부모와 교사가 자녀의 식생활 지도 관리를 돕고 가정과 교육기관이 연계한 교육 프로그램이 활성화 될 수 있도록 지속적인 관심을 기울여 나가야 할 것이며, 이에 따른

  • PDF