• Title/Summary/Keyword: 고장 분석

Search Result 2,043, Processing Time 0.03 seconds

A Study on Water Level Control of PWR Steam Generator at Low Power Operation and Transient States (저출력 및 과도상태시 원전 증기발생기 수위제어에 관한 연구)

  • Na, Nan-Ju;Kwon, Kee-Choon;Bien, Zeungnam
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.3 no.2
    • /
    • pp.18-35
    • /
    • 1993
  • The water level control system of the steam generator in a pressurized water reactor and its control problems are analysed. In this work the stable control strategy during the low power operation and transient states is studied. To solve the problem, a fuzzy logic control method is applied as a basic algorithm of the controller. The control algorithm is based on the operator's knowledges and the experiences of manual operation for water level control at the compact nuclear simulator set up in Korea Atomic Energy Research Institute. From a viewpoint of the system realization, the control variables and rules are established considering simpler tuning and the input-output relation. The control strategy includes the dynamic tuning method and employs a substitutional information using the bypass valve opening instead of incorrectly measured signal at the low flow rate as the fuzzy variable of the flow rate during the pressure control mode of the steam generator. It also involves the switching algorithm between the control valves to suppress the perturbation of water level. The simulation results show that both of the fine control action at the small level error and the quick response at the large level error can be obtained and that the performance of the controller is improved.

  • PDF

Derivation of Safety Management Implications through Analysis of Major Elevator Failures (승강기 중대고장 분석을 통한 안전관리 시사점 도출)

  • Kim, Beom-Sang;Park, Poem
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.3
    • /
    • pp.23-29
    • /
    • 2020
  • As the duty to report and investigate major elevator failures has expanded due to the total amendment of the Elevator Safety Management Act in 2018, more important information on major elevator failures that have been partially identified has been collected. As of 2019, the number of elevators in Korea exceeded 700,000, making it the eighth-class elevator powerhouse in the world, but there is a trend of increasing casualties due to accidents and breakdowns. An Seung-gang-gi is a term that encompasses an elevator that moves vertically and an escalator that moves horizontally. It is an important means of transportation for most citizens that are encountered almost every day in daily life, and it is also necessary as a means of transportation that enables the construction of skyscrapers. And it seems that its importance will never diminish in the future. Major elevator failures are the main cause of dispatch when accumulating the number of 119 dispatches, and the frequency of occurrence is high. It's a shame. According to Heinrich's Law, 300 minor signs and danger phenomena precede, 29 minor accidents and 1 major accident. Accidents caused by elevators are increasing every year due to the increase in the number of installations, and the damage is threatening the valuable lives and property of users and workers in related fields due to fatal risks such as death and serious injury. Elevator safety management can achieve its purpose only when it is managed with the usual interests, awareness of safety, and full efforts of the users, workers, and the government concerned. This study was analyzed based on 2019 data notified to the Korea Elevator Safety Agency on major breakdowns improved after the revision of the Elevator Safety Management Act in 2018, and a total of 8,256 data were analyzed using the SPSS 21 version, a statistical analysis tool, to analyze the correlation with technical statistics. Proceeded. Through the analysis, it was possible to obtain preventive safety management data to prevent serious elevator safety accidents from occurring, and to derive meaningful implications that related safety management and maintenance can be effectively operated to prevent serious failures. In addition, through this analysis, we expect the development of related industries and legal and institutional improvement.

A Study on the Improvement of Passenger Ship Rudder Stock and Tiller Locking Nut Loosening by Analyzing an Investigation Report and the NAS 3350 Test (조타장치 사고 재결서 분석과 NAS 3350 시험을 통한 카페리 여객선 타두재와 틸러 체결 너트 풀림 개선에 관한 연구)

  • Kang, Dae-Kon;Kim, Shin Hyo;Park, Jai-Hak
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.2
    • /
    • pp.253-259
    • /
    • 2018
  • In February 2014, the rudder upper stock and the nut of a passenger ship were released and an accident occurred. That accident occurred because the steering gear of passenger ships that was intended to move many passengers. The accidents due to steering gear was zero according to 2010-2016 statistics. There is no rules prevent loosening of the upper rudder nut in "Ship Safety Act" and "Structural standard of steel ship". Since the accident, the Korea register has been revised to the joining method in Part 5 Chapter 7 of the rules in the classification of steel ships. In the field survey of 12 passenger ships operating on Mokpo and surrounding islands, the welding method was applied in the cases as the fastening method. The fastening type was equipped with two C-type structures. It was structured to be difficult to access. The NAS 3350 test was conducted to investigate ways to prevent homologous accident considering the characteristic of passenger ships that need to lift or unload rides once a year.

Study on Development of Automated System for Hazard Screening at Analysis (위험 선별 및 분석 통합 자동화 시스템 개발에 대한 연구)

  • 한의진;김용하;최승준;김구회;윤인섭
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.20-27
    • /
    • 2003
  • Hazard Analysis is one of the basic tasks to ensure the safety of chemical plants. However, it is an arduous, tedious, time-consuming work and requires multidisciplinary knowledge and demands considerable cognitive load from the analysts. To overcome these problems, there have been attempts to automate this work by utilizing computer technology, particularly in the area of knowledge-based technique. There is two methods in the risk assessment of Chemical plant; quantitative and qualitative risk assessment. Both of them have been applied respectively, but if the integrated method of quantitative and qualitative risk assessments is used, all of the advantage of two methods can be applied. It is difficult to carry out integrated risk management of chemical plant. Therefore, automated integration system of risk management is necessary. We developed S/W Automated System for Hazard Screening & Analysis(ASCA) and applied to practical plant. By applying ASCA to case study, we can get the information about relative ranks of equipments, variable deviation, and consequence of potential accident. In this study, we applied ASCA to the H.T.U(Hydrotreating Unit) of the process to produce aromatic material. We could know relative ranks of equipments, variable deviation of malfunction in storage tank, D-101, and consequence of potential accident using ASCA. If integrated risk management in the chemical plant is applied, we can develop the emergency plan and prevent the accident.

A Study on the Reliability Improvement Plan on Electric Leakage & Ground Fault of Low-voltage Electrical Line (저압전로의 누전.지락에 대한 신뢰성향상 방안에 관한 연구)

  • Kang, Kyung-Won;Yoon, Myung-O;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.136-145
    • /
    • 2011
  • One of a large proportion among the causes of fire is electrical factors, and of fire by electric factors, the accident which accounted for over certain percentage is electric leakage and ground fault. In order to reduce the electric leakage and ground fault, the technical guidelines on the protection of ground fault in the low-voltage electrical line (KECG 1091-2011) was amended for reflecting recent international standard, IEC 60364-4-41, and new conservation methods, which improved the reliability by recovering the facility's all-time use operation and breakdown defect, was on the rise. Accordingly, in this paper, after grasping the fire's status for last 10 years and analyzing the risk of electrical fires, and as a way to improve the electric leakage and ground fault accident which accounted for more than certain percentage, the revision of KECG 1091-2011 will be reviewed. And then, after applying to the preventive conservation methods in order to enhance the protection reliability of electric leakage and ground fault detection, the problems at issue routine inspection scheme and durable years scheme in time-scheduled conservation method are listed, along with suggestion of the problem-solving scheme, and the leakage current integrated monitoring systems and digital electric leakage devices by status monitor conservation method will be proposed.

Development of Monitoring System for Real Time Maintenance of Road Beacon Light (도로 표시등 실시간 유지관리를 위한 모니터링시스템 개발)

  • Lee, Jong Ho;Kim, Kyou Jeon;Choi, Ju Weon;Ahn, Won Tea;Lee, Seung Ki;Choi, Seok Keun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.3
    • /
    • pp.69-75
    • /
    • 2015
  • Road facilities for safe driving were designed for drivers to distinguish them during day and night, but they cannot play their role when the weather becomes worse. Recently, the road facilities have been designed by using electric and electronic technology so that they can be displayed well at a long distance, but they should be replaced very often due to their frequent breakdown. So, there are many problems in traffic calming and maintenance. In this study, to solve the above problems, semi-permanent LED beacon light was installed in the area where traffic accident are frequent, and monitoring system was developed so that the LED beacon light can be maintenanced by connecting with system. For the above installation and development, system was based on window operating system and it was developed for worker to operate it by using P.C. through connecting with wireless local area network. The result of this study led to analyzing state information on the battery of field-installed LED beacon light in real time, and manegement to effectively by predicting their life cycle.

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Power Generation and Stream - Results of the Field Investigation (바이오가스 이용 기술지침 마련을 위한 연구(I) - 현장조사 결과 중심으로)

  • Moon, HeeSung;Bae, Jisu;Park, Hoyeun;Jeon, Taewan;Lee, Younggi;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.1
    • /
    • pp.55-64
    • /
    • 2018
  • The purpose of this study is to provide a design and operation technical guideline for meeting the appropriate design criteria to biogas utilization treating organic wastes. In accordance with the government's mid-to long-term policies on bio-gasification and energization of organic wastes, the expansion of the waste-to-energy (WTE) facilities is being remarkably promoted. However, because of the limitation of livestock manure containing low-concentration of volatile solids, there has been increased in combined bio-gasification without installing new anaerobic digestion facilities. The characteristics and common problems of each treatment processes were investigated for on-going 11 bio-gasification facilities. The seasonal precision monitoring of chemicophysics analysis on anaerobic digestor samples was conducted to provide guidelines for design and operation according to the progress of biogas utilization. Consequently, Major problems were investigated such as large deviation of organic materials depending on seasons, proper dehumidification of biogas, pretreatment of hydrogen sulfide, operation of power generation and steam. This study was conducted to optimize biogas utilization of type of organic waste(containing sewage sludge and food waste, animal manure), research the facilities problem through field investigation.

Electric Circuit Analysis for PV Array on Short-Circuit Failure of Bypass Diode in PV Module (PV모듈의 바이패스 다이오드 단락 고장 시 태양광어레이 회로 특성분석)

  • Lee, Chung-Geun;Shin, Woo-Gyun;Lim, Jong Rok;Hwang, Hye-Mi;Ju, Young-Chul;Jung, Young-Seok;Kang, Gi-Hwan;Chang, Hyo-Sik;Ko, Suk-Whan
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.15-25
    • /
    • 2019
  • As the installation of photovoltaic systems increases, fire accidents of PV system grow every year. Most of PV system fires have been reported to be caused by electrical components. The majority of fire accidents occurred in combiner box, which is presumed to be short-circuit accidents due to dustproof and waterproof failures or heat deterioration of blocking diode. For this reason, the blocking diode installation became optional by revised PV combiner regulation. In this paper, according to the revised regulation, reverse current that generated by voltage mismatch was measured and analyzed in PV array without a blocking diode. The factors that cause voltage mismatch in array are assumed to be shaded PV module and short circuit failure of bypass diode. As the result of experiment, there is no reverse current to flow under shading condition in module, but reverse current flows on the failure of bypass diode in module. According to the module's I-V characteristic curve analysis, open voltage was slightly reduced due to operation of bypass diode in shading. However, it showed that open circuit voltage has decreased significantly in the failure of bypass diode. This indicates that the difference in open voltage reduction of voltage mismatch factor causes reverse current to flow.

Concurrency Control Using the Update Graph in Replicated Database Systems (중복 데이터베이스 시스템에서 갱신그래프를 이용한 동시성제어)

  • Choe, Hui-Yeong;Lee, Gwi-Sang;Hwang, Bu-Hyeon
    • The KIPS Transactions:PartD
    • /
    • v.9D no.4
    • /
    • pp.587-602
    • /
    • 2002
  • Replicated database system was emerged to resolve the problem of reduction of the availability and the reliability due to the communication failures and site errors generated at centralized database system. But if update transactions are many occurred, the update is equally executed for all replicated data. Therefore, there are many problems the same thing a message overhead generated by synchronization and the reduce of concurrency happened because of delaying the transaction. In this paper, I propose a new concurrency control algorithm for enhancing the degree of parallelism of the transaction in fully replicated database designed to improve the availability and the reliability. To improve the system performance in the replicated database should be performed the last operations in the submitted site of transactions and be independently executed update-only transactions composed of write-only transactions in all sites. I propose concurrency control method to maintain the consistency of the replicated database and reflect the result of update-only transactions in all sites. The superiority of the proposed method has been tested from the respondence and withdrawal rate. The results confirm the superiority of the proposed technique over classical correlation based method.

Clinical and Statistical Analysis with Age in Cases of Pediatric Burn Patients (소아 화상 환자 2,795례에 대한 연령별 임상 통계학적 분석)

  • Cho, Ki-Hyun;Jang, Young-Chul;Lee, Jong-Wook;Koh, Jang-Hyu;Seo, Dong-Kook;Choi, Jai-Ku
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.445-450
    • /
    • 2011
  • Purpose: The objective of this study is to analyze the epidemiological characteristics of pediatric burn patients and to determine the targets for a pediatric burn prevention program. Methods: A retrospective review of all medical records of acute pediatric burn patients (age < 15 years old) admitted to our hospital between January 2005 and December 2009 was performed. Results: 1472 males and 1323 females were investigated, with a male to female ratio of 1.11 : 1. The greatest number of burn patients were those with an age of 1~2 years (1,463, 52.3%). Scalding burn was the most common cause of injury, which accounted for 2183 (78.1%) patients, followed by contact burns (10.5%), flame burn (4.9%), steam burn (3.6%). Especially steam burn was the second cause of injury in the age under 1 year, while flame burn was the second cause of injury in the age over 7 years. During recent 5 years, incidence of flame burn, steam burn, electrical burn gradually decreased. Variation of seasonal incidence is minimal and most of the patients (2,716 cases, 97.2%) had burns less than 20% TBSA (Total body surface area). The median hospital stay was 18.79 days, and the rate of operation was 28.6% with a high rate in electrical burn (76.2%), flame burn (50.0%), steam burn (46.1%). 6 patients died in this series, which yielded a mortality rate of 0.2%. Conclusion: Prevention efforts should reflect recent study results. Focused prevention program and campaign to make people aware of risk factors and their avoidance is required to reduce the number of burn accidents in children.