Statistical Blade Angular Velocity Information-based Wind Turbine Fault Diagnosis Monitoring System (블레이드 각속도 통계 정보 기반 풍력 발전기 고장 진단 모니터링 시스템)

  • Kim, Byoungjin;Kang, Suk-Ju;Park, Joon-Young
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.619-625
    • /
    • 2016
  • In this paper, we propose a new fault diagnosis monitoring system using gyro sensor-based angular velocity calculation for blades of the wind turbine system. First, the proposed system generates the angular velocity dataset for the rotation speed of the normal blade. Using the dataset, we estimate and evaluate the state of blades for the wind turbine by comparing the current state with the pre-calculated normal state. In the experimental results, the angular velocity of the normal state was higher than $360^{\circ}/s$ while that of the damaged blades was lower than $360^{\circ}/s$ and the standard deviation of the angular velocity was significantly increased.

A Study on the Fault Tolerant System for the Optimum Performance of Virtual Sensor (가상센서를 활용한 고장 허용 시스템에 관한 연구)

  • Song, Min-Woo;Choi, Won-Seok;Lee, Doo-Wan;Jang, Kyung-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.7
    • /
    • pp.1634-1640
    • /
    • 2010
  • In this paper, I studied the "Establishment of Fault Tolerant System" as well as the sensor and cylinder that are general components being used in automation equipments. I design a system that when the sensor breaks down on free flow conveyor, it will be converted to virtual sensor system mode by simulation, also I design IPC(Internal Pressure Cylinder), a basis of various applicable fault tolerant system by analyzing the changing of analog data according to the load of operation. With IPC and the increasing ability of developer, the Fault Tolerant System will be widely applied in the increasment of service time of cylinder, grease pouring time expection, fault recognition of cylinder and etc.

Electric Power System Relay Protection System Design for the Proton Accelerator Research Center of PEFP (양성자가속기 연구센터의 전력계통 보호계전 방식)

  • Mun, Kyeong-Jun;Lee, Seok-Ki;Jeon, Gye-Po;Cho, Jin-Sam;Min, Yi-Sub;Nam, Jung-Min;Kim, Jun-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.428_429
    • /
    • 2009
  • 전력계통 운용시 고장이 발생하면 계통 운전원은 계전기 및 차단기 관련 동작정보 및 경보로부터 해당 고장내용을 판단하고 계통복구를 위한 조작을 행한다. 본 논문에서는 현재 건설중인 양성자가속기 연구센터의 전력 계통 운용시 발생한 고장에 따른 다중경보신호를 분석하기 위하여 전력계통의 고장영역별로 동작하는 보호계전기 신호, 차단기 신호 및 경보신호를 분류함으로써 이를 향후 전력계통 운용시 고장진단을 위한 기초자료로 활용하고자 한다.

  • PDF

Observer Design for H- Fault Detection of Large Scale T-S Fuzzy Systems (대규모 T-S 퍼지 시스템의 H- 고장검출을 위한 관측기 설계)

  • Jee, Sung-Chul;Lee, Ho-Jae;Joo, Young-Hoon;Kim, Do-Wan
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.1
    • /
    • pp.15-20
    • /
    • 2010
  • In this paper, we discuss a decentralized observer design problem for the fault detection in the large-scale continuous-time T-S (Takagi-Sugeno) fuzzy system. Since the fault detection residual is desired to be as sensitive as possible, on the fault, we use $\mathfrak{H}_-$ index performance criterion. Sufficient conditions for the existence of such a observer is presented in terms of linear matrix inequalities. Simulation results show the effectiveness of the proposed method.

Implementation of Digital Distance Protection Schemes using Optimal FIR Filter on a Digital Signal Processor (최척 FIR 필터를 이용한 디지탈 거리 계전 방식의 DSP 프로세서 구현)

  • Kwon, W.H.;Lee, G.W.;Lee, K.S.;Yoon, M.C.;Yoo, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.106-112
    • /
    • 1990
  • This paper presents the FIR filtering scheme for digital distance protection. In most faults, there exists severe oscillation of apparent impedance according to distortion in transient waveforms. In these cases, this scheme provides more accurate fault detection and fault location, as compared with conventional schemes for digital distance protection or Kalman filtering schemes. The test of these facts were performed on EMTP result data. For the real time implementation of the proposed schemes, the motorola DSP 56001 was used to the main calculation board of the digital protective relaying system.

  • PDF

A Study on Design for Incipient Failure Detection and Prediction System of Electric Supply Equipments Based on IoT (loT 기반의 배전설비 고장 감지 및 예지 시스템 설계에 관한 연구)

  • Kim, Hong-Geun;Lee, Myeong-Bae;Cho, Yong-Yun;Park, Jang-Woo;Shin, Chang-Sun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.405-407
    • /
    • 2016
  • 최근, ICT/loT 기술과의 융합은 다양한 산업분야에 적용되고 있으며, 안정적인 전력공급 및 지능형전력망 구축에 대해 다양한 연구가 이루어지고 있다. 특히, 수요라인과 직접적으로 연관된 배전계통의 효율적인 운영 및 배전설비의 유지/관리 기술에 대한 연구에 많은 연구를 수행하고 있다. 본 논문에서는 다양한 배전설비에 대한 환경정보를 loT 센서를 통해 수집함으로써 실시간으로 정전상황을 불러올 수 있는 기자재의 고장감지 및 예측을 위한 시스템 모델을 제안한다. 제안하는 시스템 모델은 실시간으로 수집되는 정보들에 대해 시계열 기반의 필터링 및 이상점 판단을 위한 성분 분석을 실시하고, 고장진단 및 예측을 위해 기계학습 기반의 데이터 분석실시하여 기자재들의 고장감지 및 고장 발생 여부를 예측한다.

Anti-allergic Effect of Zizania latifolia Turcz Extracts (고장초의 항알레르기 효과)

  • Lee, Eun-Jung;Whang, Eun-Yeong;Whang, Key;Lee, In-Seon;Yang, Seun-Ah
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.6
    • /
    • pp.717-721
    • /
    • 2009
  • The anti-allergic effect of the methanol extract of Zizania latifolia Turcz was investigated. Methanol extract of Z. latifolia Trucz did not display any cytotoxicity activities in the IgE-sensitized RBL-2H3 cells. The extract was found to inhibit compound 48/80-induced degranulation and antigen-induced $\beta$-hexosaminidase release as well as PMA plus A23187-induced TNF-$\alpha$ production in RBL-2H3 mast cells in a dose-dependent manner. Release of $\beta$-hexosaminidase, a marker for the release of histamine in mast cells, was inhibited with an $IC_{50}$ value of $73.8\;{\mu}g/mL$. These results suggest that Z. latifolia extracts may be useful for the prevention of type I allergic reaction.

Kinematic Model based Predictive Fault Diagnosis Algorithm of Autonomous Vehicles Using Sliding Mode Observer (슬라이딩 모드 관측기를 이용한 기구학 모델 기반 자율주행 자동차의 예견 고장진단 알고리즘)

  • Oh, Kwang Seok;Yi, Kyong Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.10
    • /
    • pp.931-940
    • /
    • 2017
  • This paper describes a predictive fault diagnosis algorithm for autonomous vehicles based on a kinematic model that uses a sliding mode observer. To ensure the safety of autonomous vehicles, reliable information about the environment and vehicle dynamic states is required. A predictive algorithm that can interactively diagnose longitudinal environment and vehicle acceleration information is proposed in this paper to evaluate the reliability of sensors. To design the diagnosis algorithm, a longitudinal kinematic model is used based on a sliding mode observer. The reliability of the fault diagnosis algorithm can be ensured because the sliding mode observer utilized can reconstruct the relative acceleration despite faulty signals in the longitudinal environment information. Actual data based performance evaluations are conducted with various fault conditions for a reasonable performance evaluation of the predictive fault diagnosis algorithm presented in this paper. The evaluation results show that the proposed diagnosis algorithm can reasonably diagnose the faults in the longitudinal environment and acceleration information for all fault conditions.

`94 원전 운영 실적

  • 홍주보
    • Nuclear industry
    • /
    • v.15 no.2 s.144
    • /
    • pp.15-21
    • /
    • 1995
  • 값싸고 질좋은 전력의 안정적 공급노력은 지속적으로 추진되었으며, 계획예방정비기간의 조정, 정비기간의 단축 등 공급능력 증대와 고장정지 예방을 위한 다각적인 노력과 중국 광동원전 기술인력 지원 등 1994년은 원전기술 수출의 원년의 해로 원전기술을 세계적 수준으로 올리는데 성공적인 한해였다고 판단된다.

  • PDF

Reliability Analysis on Firewater Supply Facilities based on the Probability Theory with Considering Common Cause Failures (소방수 공급설비에 대한 공통원인고장을 고려한 확률론적 신뢰도 분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.76-85
    • /
    • 2003
  • In this study, we write down the definitions, their causes and the techniques of analysis as a theoretical consideration of common cause failures, and investigate the limitation and the importance of the common cause failures by applying to the analysis on the fire protection as a representative safety facility. As you can know in the reliability analysis, most impressive cause is the malfunctions of pumping operations; especially the common cause failure of two pumps is dominant. In other words, it is possible to assess system-reliability as twice as actual without CCF From these, CCF is extraordinarily important and the results are highly dependent on the CCF factor. And although it would increase with multiple installations, the reliability are not defined as linear with those multiplications. In addition, the differences in results due to the models for analysis are not significant, whereas the various sources of data produce highly different results. Therefore, we conclude that the reliabilities are dependent on the quality of the usable data much better than the variety of models. As a result, the basic and engineering device for the preventions of CCF of the multiple facilities is to design it as reliably as to design the fire-water pump. That is to say, we must assess those reliabilities using PFD whether they are appropriate to SIL (Safety Integrity Level) which is required for the reliability in SIS (Safety Instrumented System). The result of the analysis on the reliability of the fire-water supply with CCF shows that PFD is 3.80E-3, so that it cannot be said to be designed as safely as in the level of SIL5. However, without CCF, PFD is 1.82E-3 which means that they are designed as unsafely as before.