• Title/Summary/Keyword: 고장원인

Search Result 523, Processing Time 0.028 seconds

A Study of Humidification Method in PEMFC (고분자전해질형 연료전지의 가습 방법에 대한 연구)

  • Hyun, Deok-Su;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.3
    • /
    • pp.212-216
    • /
    • 2003
  • The humidification measurement system designed in laboratory was used to measure relative humidity and temperature of reaction gases passing through internal or external humidifier which was used in proton exchange membrane fuel cell test station. The relative humidity of gases was stabilized after $10\~20$ minutes and thus credibility of data could be assured. The effect of relative humidity on fuel cell performance could be analyzed by humidity measurement system. Extreme caution was needed to avoid humidity sensor mal-function or failure which is probable in experiment of high humidity condition near $100\%$. The amount of water carried by gas through humidifier was increased along the flow rate of gas. However, the extent of increase was lowered at high gas flow rate. These phenomena could be analyzed as residence time effect of gas in humidifier.

Estimation of Effect Zone for the Establishment of Damage-Minimizing Plan of Chemical Plants (화학공장의 사고피해 최소화 대책수립을 위한 영향범위 평가)

  • Lee, Hern-Chang;Han, Seong-Hwan;Cho, Ji-Hoon;Shin, Dong-Il;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.69-74
    • /
    • 2011
  • As a way to propose a method for the establishment of practical damage-minimizing plan for chemical plants, the release scenario was established by using API-581 BRD and the effect zone was estimated by the KS-RBI program supporting the quantitative cause analysis. And the risk assessment was performed. As a result, we found that to minimize the damage of a chemical plant, it is effective to use four release hole diameters (small, medium, large and rupture) and release time estimated according to the classes of detection and isolation systems. In addition, it can be safely said that through appling the damage areas considering weighted average by failure frequency and worst-case simultaneously, industrial sites can come up with the effective emergency response plan.

Feasibility Study of Modified Durometer to Evaluate Setting Time of the Concrete (콘크리트의 응결시간 판정시 개량형 듀로미터의 사용 가능성 분석)

  • Han, Cheon-Goo;Han, Min-Cheol;Shin, Yong-Sub
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.5
    • /
    • pp.433-440
    • /
    • 2020
  • In this study, a new type of Durometer was invented by modifying the currently used Durometer with the hemisphere shaped needle to columnar shaped needle. The aim of the study is, hence, to provide the feasibility of the advanced Durometer for assessing setting time of the concrete. Generally, the finishing of concrete surface should be conducted to secure the smooth surface, improve the permeability, and prevent the plastic shrinkage cracking. Although this surface finishing work should be conducted during the plastic phase between initial and final setting, currently in practical situations, the timing of starting the finishing work was determined by the sense of the worker. To improve this situation, Kato Junji suggested to use the hemisphere and needle shaped Durometers to determine the initial and final setting time, respectively. However, in this case, there are difficulties of using two different Durometers and of occurring failure of the Durometer due to the intruded cement paste. To prove the feasibility of new typed Durometer, setting time and surface hardness were evaluated by applying for the concrete with various replacing ratios of fly-ash and coal gasification slag as an aggregate.

Shield TBM trouble cases review and parameter study for the cause analysis (쉴드 TBM 트러블 사례 및 매개변수 연구를 통한 원인 분석)

  • Koh, Sungyil;La, You-Sung;Kim, Bumjoo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.2
    • /
    • pp.197-217
    • /
    • 2020
  • Shield TBM tunneling, used in the construction of Seoul subway line 7 and line 9, has been well known as a very efficient, as well as safe, tunneling method. Although the Shield TBM method has been known to be effectively used in poor ground conditions, a number of troubles have occurred during the use of the shield TBM, due to inappropriate machine selection, machine breakdown, and unpredicted ground conditions etc. In this study, several accidents and trouble cases occurred during excavation by Shield TBM, reported from Japan, were investigated. A series of numerical analysis was then performed to compare with the trouble cases and back-analysis results for the cause analysis. The lessons learned from the case studies are presented at the end.

DC Traction Regenerative Energy Storage Devices using Super-capacitor (슈퍼 커패시터를 이용한 직류철도 회생에너지 저장장치)

  • Kim, Jong-Yoon;Jung, Doo-Yong;Jang, Su-Jin;Lee, Byoung-Kuk;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.247-256
    • /
    • 2008
  • Regenerative energy generated by regenerative braking of DC traction can cause the system malfunction or damage to the rectifier, or malfunction of the power conversion device in power supply system by DC Line voltage rise in feeder line. Regenerative energy storage system using super capacitor is one of the ways to stabilize DC line voltage. In this paper, energy storage system of DC traction system using super-capacitor bank is implemented and using the field measurement data of the station N and the station S on the Line 2, the operation characteristics of line voltage caused by regenerative energy of electric trains are verified. Also, charge/discharge characteristics of super capacitor are verified as well. Thus, we can verify the operation characteristics of super-capacitor bank for regenerative energy storage system installed in DC Traction. And if we can use field measurement data of DC line voltage, we have obtained cost reduction. The stabilization of the system will be improved by measuring the operation characteristics of regenerative energy storage system in certain section operated by DC traction and predicting the capacity and lifetime of super-capacitor.

The study on Accelerated Life-Time Reliability Test Methods of Ni-Mn-B ternary alloy Plating(electrodeposit) (Ni-Mn-B 삼원합금도금 가속수명 및 신뢰성 평가에 대한 연구)

  • Ma, Seung-hwan;Noh, young-tai;Jang, gun-ik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.2993-2999
    • /
    • 2015
  • Steel companies are applying Ni-B or Ni-Co alloy plating to protect the surface of Continuous casting mold, and they are using saccharin polish which causes crack on plating layer due to sulfur in saccharin. It is considered that the Ni-S compound causes the cracking and additional tensile stresses. The Ni-Mn-B ternary alloy plating was developed for suppression of crack by forming Mn-S compound before Ni-S compound is formed, but there were no domestic or international standard on the Ni-Mn-B alloy plating. Therefore, reliability evaluation standard was established to evaluate the newly developed Ni-Mn-B plating. To develop accelerating life testing method, FMEA(Failure Mode & Effective analysis) was used to analyze the cause of the main failure in plating. The Ni-Mn-B reliability standard included accelerating life test method, and it was categorized by the fundamental performance test, environment test, and accelerated life test, and was designed to guarantee 1 000 hours of B10 life with 80 % reliable level.

Measurement System for Vehicle Electric Power using LabVIEW (LabVIEW를 이용한 자동차 발전기 전압 계측시스템)

  • So, Soon-Sun;Yang, Su-Jin;Lee, Seong-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.5899-5905
    • /
    • 2014
  • Faults in electric power system can be a critical problem for vehicles. The system durability is determined mainly by the durability of their components and operating conditions. Monitoring the conditions of the electric power system may be necessary because it is very difficult to predict precisely when it will fail. Therefore, the aim of this study was to develop a diagnosis system for an electric power system of a vehicle. The alternator voltage, excitation voltage, lamp voltage, battery voltage, and engine rpm from a crank angle sensor are monitored continuously and the system fault can be then detected in real time. NI USB- 9201 DAQ and LabVIEW SW have been used to measure the voltages and analyze the data. Compared to conventional measurements for only each component, an integrated and portable measurement method was developed. In addition to the monitoring the electric power system in real time, the saved data from the measurement also provides valuable information to improve the durability of the components.

A Study for Basic Durability Assessment of Shale Shaker (셰일 셰이커 기초 내구성 평가에 관한 연구)

  • Oh, Jung-Soo;Kim, Sung-Min;Whang, Jong-Duk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.296-302
    • /
    • 2019
  • In this study, a basic durability assessment was performed by selecting the main part of a trial product of a shale shaker, which is one of components for a mud circular system. For a preliminary durability assessment, it was assumed that the lifetime of the bearing for the vibrator motor and the stiffness of the support spring are affected by the vibration when the motor operates continuously. In the case of the motor, the initial p-p level was 0.72 g, but after 100 hours of operation, the p-p level was rapidly increased to 1.26 g. Bearing defects could be estimated through ball defect frequency analysis. In the case of the spring, the stiffness of the spring was reduced by approximately 3.78% at the end of 2,000 hours of the fatigue-durability test by applying excitation conditions to shale shaker body. In the future, we will analyze the influence of the particle removal efficiency of the shale shaker.

Structural Improvement for Crack of Integrated Circuit in Single Board Computer by Structure Analysis (단일보드컴퓨터 구조해석을 통한 집적회로 균열현상의 구조적 개선)

  • Ryu, Jeong-min;Lee, Yong-jun;Sohn, Kwonil
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.460-465
    • /
    • 2019
  • In this study, we aim to derive a solution from the structural analysis for electrical failure of single board computers for computing navigation information. By analyzing the characteristic factor, we identify that crack occur on the central processing unit board due to a certain structural problem, and that the physical effect by the crack make communication function be impossible to perform, which it causes booting error. In order to find the location of excessive stress causing the crack, structural analysis for the single board computer is done. From the structural analysis, the areas where stress concentration occurs are identified, and improvement methods changing the structures are developed. As a result, we shows that stresses are reduced entirely on the stress distribution for the improved structure. In addition, heat analysis shows that changing the structure to reduce stresses is not affect to the heat radiation, and the thermal resistance of the actual equipment is verified by measuring the temperature of the heat sink applied with the improved structure.

Development of Catenary Stagger and Height Measurement System using Laser (레이저를 이용한 전차선 편위 및 높이 측정 시스템 개발)

  • Song, Sung-Gun;Lee, Teak-Hee;Song, Jae-Yeol;Park, Seong-Mo
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.6
    • /
    • pp.569-574
    • /
    • 2008
  • Catenary and Pantograph are used to transmit electrical energy to electric railways. Catenary (Overhead Contact Lines) should be installed precisely and managed for stable train operations. But external factors such as weather, temperature, etc., or aging affect catenary geometry. Changed catenary stagger and height cause high voltage spark or instant electric contact loss. Big spark derived from contact loss can damage the pantograph carbon strip and overhead contact lines that might interrupt the train operations. Therefore, to prevent a big scale spark or electric contact loss, catenary maintenance are required catenary geometry measurement systems with catenary maintenance capability. In this paper, we describe the development of catenary height and stagger measurement system. The catenary height and stagger measurement system uses Acuity company's AR4000 Laser Range Finder for distance measurement and AccuRange Line Scanner for degree measurement. This system detects suspicious overhead line sections with excessive stagger and height stagger variance.