• Title/Summary/Keyword: 고자장

Search Result 158, Processing Time 0.031 seconds

Study on NbTi superconducting joint process for high field MRI magnet (고자장 MRI 마그네트를 위한 NbTi 초전도 접합 공정 연구)

  • 하동우;오상수;하홍수;이남진;고락길;권영길;류강식
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.165-167
    • /
    • 2002
  • NbTi/Cu superconducting wires were jointed inserting the NbTi filaments into Cu/NbTi sleeve and pressing it. When the NbTi filaments were inserted into Cu/NbTi sleeve, additional NbTi filaments were inserted together to increase the numbers of filaments in the hole of sleeve. Critical current of the joint of 28 filaments wires with 1.7 mm thickness of dimple was 450 A at 4.2K, 0.5T. Ic of the joint of 54 filaments wires with 2.0 mm thickness of dimple was 600 A at 4.2K, 2T. It is possible to manufacture MRI magnet by using these results.

  • PDF

Development of a 1.8T HTS Insert Coil for High Field Magnet (고자장 자석용 1.8T HTS insert 코일 개발)

  • Bae, Joon-Han;Seong, Ki-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1035-1038
    • /
    • 2007
  • We designed and manufactured a 1.8T high temperature superconducting(HTS) insert coil for a NMR magnet operated at 4.2 K. Suitable HTS superconductor and HTS coil were carefully designed and developed. We have selected multi-filamentary Bi2223 conductor fabricated by American Superconductor Corporation(AMSC). The selected conductor consists of Bi2223 filaments of 55, silver stabilizer and stainless steel reinforcement tapes. Therefore, it shows good hoop strength as well as compression tolerance. The conductor has a tape cross-section of 0.31mm x 4.8mm. the Bi2223 conductor shows large anisotropy of critical current. The critical current of conductor in magnetic field parallel to the flat surface are much higher than that in magnetic field perpendicular. The HTS coil has an inner diameter of 78 mm, an outer diameter of 127 mm and a coil length of 600 mm. In this paper, the detailed design, fabrication and test results on the HTS insert coil are presented.

Design of 5T HTS Magnet using 2G Wire (2G 선재를 이용한 5T급 고온초전도 마그넷 설계)

  • Ku, Myung-Hwan;Kim, Dong-Lak;Choi, Yeon-Suk;Lee, Woo-Ho;Shin, Dong-Won;Kim, Myung-Su;Cha, Guee-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1117-1118
    • /
    • 2011
  • NMR이나 MRI와 같은 고자장을 필요로 하는 마그넷은 높은 운전전류를 갖는 초전도 선재를 이용하여 제작된다. 이때 마그넷은 여러 코일을 겹쳐서 제작하는 것이 일반적이고, 크게 내측마그넷과 외측 마그넷으로 구분할 수 있다. 본 논문에서는 15T 외측마그넷 안에서 동작하는 5T급 내측마그넷의 설계 과정을 나타내었다. 내측마그넷은 2세대 고온초전도 선재를 이용하여 설계되고, 4.2K의 액체헬륨 안에서 동작한다. 마그넷의 임계전류는 초전도 선재의 $I_c$-B 특성을 고려하여 산정하였고, 임계전류를 바탕으로 운전전류를 결정하였다. 내측마그넷의 발생자장이 5T를 만족하는 운전전류와 마그넷의 형상을 계산을 통하여 제시하였다.

  • PDF

Non-linear Analysis for Penetrated Magnetic Field in Superconducting Nb Foil (인가 자장에 의한 초전도 Nb 박막의 비선형적인 자장분포 해석)

  • Chung, Yoon-Do;Oh, Sung-Kwun;Kim, Hyun-Ki;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.644_645
    • /
    • 2009
  • 이미 개발된 리니어형 초전도 전류 보상기는 다양한 동작 조건에서 충전 전류 실험을 통해 검증되었고, 고자장 초전도 마그넷용 전류보상기로 적용하기위한 기본적인 특성을 수행하고 있다. 충전전류는 초전도 Nb 박막에 인가되는 자장의 크기와 이동속도(주파수)에 영향을 받아 발생됨이 실험적으로 이미 확인되었다. 특히 인가 주파수가 임계점이상 (20 Hz이상)에서 충전전류가 서서히 감소되는 비선형적인 충전특성이 확인되었다. 본 논문에서는 초전도 Nb 박막에 침투되는 자장의 분포를 3D FEM을 이용하여 자장분포 해석을 수행하였다. 초전도 Nb 박막에 인가되는 자속의 이동속도에 따른 침투영역의 크기 변화를 근거로 침투자속에 따른 초전도 Nb 박막의 비선형성을 확인하였다.

  • PDF

Spin Visualization for Magnetic Resonance Imaging (자기공명영상에서의 스핀 시각화)

  • Cho, S.H.;Kang, S.W.;Jeon, Y.S.;Lim, H.J.;Kim, P.K.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2153-2154
    • /
    • 2006
  • MR imaging에서 RF pulse에 의한 Spin들의 이동과 dephase, rephase 되는 모양을 Spin visualization을 사용하면 직관적으로 이해할 수 있다. 다양한 각도의 RF pulse 가 여러 번 가해지면, spin echo 외에도 stimulated echo, "eight-ball" echo 등이 나타나기 때문에 직관적으로 echo들을 이해하기가 어려워진다. Spin에 RF pulse가 가해졌을 때, 기존의 2차원의 Profile로 spin들의 상태를 보는 것보다 3차원 공간상에서 spin들의 상태를 살펴봄으로써, 좀 더 쉽게 MR 신호를 이해할 수 있다. 특히 고자장에서 SAR 문제 때문에 낮은 각도의 RF pulse 를 사용하여 영상을 해야 하기 때문에 spin visualization은 새로운 영상 방법을 이해하거나 디자인하는데 중요하다.

  • PDF

High Field Superconducting Magnet Optimal Design for Nuclear Magnetic Resonance (NMR) Applications (핵자기공명(NMR) 응용을 위한 고자장 초전도 마그네트의 최적화 설계)

  • 고락길;조영식;권영길;진홍범;배준한;심기덕;류강식
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.150-153
    • /
    • 2000
  • NMR researches are required high field and high homogeneous super-conducting magnet. Thus superconducting magnets for NMR applications are designed with minimization of coil winding volume satisfied constraints such as field strength, field homogeneity, etc. In this paper, we are discussed optimal design of high field super-conducting magnet for NMR applications. For a design example, we designed unshielded superconducting magnet for 600MHz NMR spectrometer with 100mm room temperature bore size and obtained 14.1011[T] field strength and 1.33 ppm field homogeneity.

  • PDF

Construction of a Pulsed Field Magnetometer and Magnetic Properties Measurement of Rare Earth Permanent Magnets (고자장 펄스마그네토미터 구성 및 희토류 영구자석의 자성측정)

  • 김윤배;우병칠;박포규;김만중;김택기
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.4
    • /
    • pp.212-216
    • /
    • 1997
  • A pulsed field magnetometer with maximum applied field of 130 kOe has been constructed. The pulsed field generated by a 18 kJ capacitor bank system combined with a pulse coil was damped oscillation with the period of 10.12 ms. Magnetic hysteresis loop was measured by induction method during 10.12 ms of a pulse duration from the first positive to the second positive peak. The difference from DC magnetic properties due to the eddy current effect was inferred below 3% for the NdFeB magnet with the diameter below 5 mm.

  • PDF

자기공명영상에서 신호의 dynamic range와 quantization noise 분석

  • 안창범;이정선;김휴정;이흥규
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.75-75
    • /
    • 2002
  • 목적: 고자장 자기공명영상 시스템 등으로 신호대잡음비가 향상됨에 따라 데이터 측정에서 analog-to-digital converter (ADC)의 quantization noise 가 중요한 시스템 사양으로 부각되고 있다. 특히 자기공명영상은 공간주파수 영역에서 데이터를 측정하기 때문에 dc와 ac간의 신호 차이가 매우 크며, 이러한 dynmic range는 3-D 영상에서 더욱 커진다. 본 연구에서는 다양한 자기총명 영상기법 및 실험 파라미터에 따른 신호의 dynamic range와 ADC의 bit 수에 따른 quantization noise를 살펴봄으로써, 주어진 시스템에 적합한 ADC의 bit 수를 분석하고자 한다. 대상 및 방법: 펄스 시퀀스의 종류, 파라미터, 2D/3D 등에 따른 각 신호의 크기를 수학적으로 모델링하여 신호의 크기를 예측하였다. 또한 whole body MRI 시스템에서 실험을 통하여 신호의 크기를 비교하였다. ADC의 quantization noise를 실험과 시뮬레이션을 통하여 살펴보았다. 시뮬레이션은 test 영상을 Inverse FFT 하여 spatial frequency domain data를 만든 후, 다양한 bit 수의 ADC로 quantization을 한 후 다시 영상을 재구성하였다. 재구성된 영상과 원영상 간의 error가 quantization noise가 된다. 또한 이러한 error가 주파수 영역에서의 error 값과 일치하는지를 확인하였다.

  • PDF

High b-value Diffusion Study of Normal Brain at 3 Tesla

  • 이영주;손철호;황문정;배성진;장용민
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.83-83
    • /
    • 2002
  • 목적: 현재 임상적으로 사용되고 있는 확산경사자장의 세기 이상( > 1200)의 강한 확산 경사자장이 가해진 경우 뇌구조물들의 확산계수값을 조사하고 고자장(Bo = 3T)에서 이러한 강한 확산 경사자장을 이용하는 경우 1.5T에서 시행하는 경우와의 차이점을 비교 연구해보고자 하였다. 대상 및 방법: 정상 성인 3명을 대상으로 b-value를 0부터 3500까지 변화시키며 확산강조영상을 최대경사자장 40 mT/m, slew rate 150 T/m/s의 경사자장계가 장착된 3T MR scanner (General Electric, USA)에서 획득하였다. 사용한 펄스열은 Stejskal-Tanner type의 확산강조 경사자장이 포함된 single-shot SE EPI를 사용하였으며 영상획득시 사용한 파라미터는 다음과 같다. TR/TE= 10000/95.1, Thickness/space=512mm, FOV=24$\times$21cm, Matrix=128$\times$128, NEX=1 뇌구조물들에 관심 영역을 설정하고 b-value에 따른 신호감소를 측정하였다. 측정된 데이터를 hi-exponential decay 모델을 이용하여 분석하였다.

  • PDF

Analysis of Signal-to-Noise Ratio in High Field Multi-dimensional Magnetic Resonance Imaging (고자장 다차원 자기공명영상에서 신호대잡음비 분석)

  • Ahn, C.B.;Kim, H.J.;Chang, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2783-2785
    • /
    • 2003
  • In multi-dimensional magnetic resonance imaging, data is obtained in the spatial frequency domain. Since the signal variation in the spatial frequency domain is much larger than that in the spatial domain, analog-to-digital converts with wide conversion bits are required. In this paper, the quantization noise in magnetic resonance imaging is analyzed. The signal-to-quantization noise ratio(SQNR) in the reconstructed image is derived from the level of quantization in the data acquisition. Since the quantization noise is proportional to the signal amplitude, it becomes more dominant in high field imaging. Using the derived formula the SQNR for several MRI systems are evaluated, and it is shown that the quantization noise can be a limiting factor in high field imaging, especially in three dimensional imaging in magnetic resonance imaging.

  • PDF