• Title/Summary/Keyword: 고유동콘크리트

Search Result 225, Processing Time 0.024 seconds

Field Applicability and Manufacturing of Foam Concrete as Filler with the Low-strength and High-flow for Repair System of Ground Subsidence (지반 함몰 복구용 저강도·고유동 충전재로서 기포콘크리트 연구 및 현장적용)

  • Ma, Young;Kim, Beom-Seok;Woo, Yang-Yi;Jung, Kyung-Hun;Song, Hun-Young
    • Resources Recycling
    • /
    • v.29 no.1
    • /
    • pp.43-52
    • /
    • 2020
  • The objectives of this study were to identify the optimal mix of foam concrete with the low-strength and high-flow for the repairing ground subsidence situation emergently by utilizing a large amount of industrial by-products and evaluate the possibility by applying it to the site. The factors of the experiment were the mixing ratio of mixing water and a foaming agent and the mixing ratio of foam over paste volume. The optimal mix identified by the experiment was applied to the field and basic properties were evaluated. The results of the experiment showed that the optimal mixing ratio of mixing water and the foaming agent was 10%. Moreover, when the mixing ratio of pre-foam over paste volume was 170%, it satisfied the target. However, to ensure stable quality when applying to the field, the foam mixing ratio was set 140% for the field application. The field application test of foam concrete with the low-strength and high-flow using an eco-friendly binder satisfied all target performances. Therefore, the possibility of using it as a mixture and construction method for a ground repair system is confirmed. However, there was a quality deviation between the upper part and the lower part due to the separation between foam and paste. Consequently, further studies are needed to improve it.

The Effect of Combined Aggregates on Fluidity of the High Fluid Concrete Containing GGBFS (고로슬래그미분말을 혼입한 고유동콘크리트에서 골재조합이 콘크리트 유동성상에 미치는 영향에 관한 실험 연구)

  • Kim, Jae-Hun;Yoon, Sang-Chun;Jee, Nam-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.4
    • /
    • pp.79-86
    • /
    • 2003
  • The purpose of study is to offer base data for high fluid concrete mix property, as grasp effect of aggregate to reach much more effect for producing high fluid concrete. For this study, there are three types of combined aggregates, river sand + river aggregate(type A), river sand + crusted aggregate(type B), washed sea sand + crushed aggregate(type C) and take a factor, water-contents, water-binder ratio and S/a. And so, we had following conclusion, resulting application-ability of high fluid mortar by K-slump tester to use a handy consistency measuring instrument. And so, we had following conclusion, resulting application-ability of high fluid concrete by K-slump tester to use a handy consistency measuring instrument. 1) In cafe of regular water binder ratio, high fluid concrete suffered much effect of combined aggregates and water binder ratio. Range of water binder ratio by combined aggregates is w/b 0.4 downward(type A and B), w/b 0.35 downward(type C). 2) Water contents to need for producing high fluid concrete is minimum 170kg/$\textrm{m}^3$ without regard to combined aggregates. 3) The effect of S/a on high fluid concrete by combined aggregates is approximately S/a 50% (type A and B), s/a 50-55% (type C). 4) Consistency measuring of high fluid concrete by K-slump tester is possible and first indication value, high fluid concrete can be produced, is 6~10.5cm.

The Properties of High Flowing Concrete with the Kind and Content of Limestone Powder (석회석 미분말의 종류 및 함유율 변화에 따른 고유동 콘크리트의 특성)

  • 조중동;홍상희;조병영;장기영;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.267-270
    • /
    • 1999
  • In this paper, the application of limestone powder, which produced by being gathered electrically in the process of manufacturing of cement, to high fluidity concrete are investigated. According to the experimental results, especially, high viscosity and the loss of air content are accomplished by applying limestone powder as the partial substitution of fine aggregates. In case of hardened concrete, high compressive strength can be achieved by using limestone powder.

  • PDF

Permeability of Self-Consolidating Concrete (고유동 콘크리트의 투수성에 관한 연구)

  • 김민석;최석환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.156-159
    • /
    • 2003
  • Large amount of binders and high-range AE water-reducing (HRWR) agent are required for self-consolidating concrete in order to achieve flowability and segregation resistance. In this study, the initial permeability of SSC(self-consolidating concrete) until the age of 28 days is measured and compared with those of other SSCs, in which some parts of cement are substituted with fly ash or blast furnace slag. The strengths of SSC samples are also examined along with the permeability change.

  • PDF

Setting and Compressive Strength Development of Hihg Flowing Concrete (고유동 콘크리트의 응결특성과 압축강도 발현)

  • 권영진;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.8-13
    • /
    • 1995
  • High flowing concrete has been made using a combination of different cementitious material. The use of supplementary cementitious material like ground granulated slag is not only interesting from an economical point of view but also from a mechanical and rheological point of view. In the case of high strength concrete, relation between the maturity and compressive strength development of high strength concrete is aproximated by appling gompertz curve and suggested new estimating method. It is the aim of this study to analysis the effect of different types of mineral fine power on the setting and compressive strength development of high flowing concrete.

  • PDF

A Fundamental Study on the Properties of High - Fluidity Concrete Using Viscosity Agent -Part 1 :Properties of Fresh Concrete - (증점제를 이용한 고유동 콘크리트의 특성에 관한 실험적 연구-제1보: 굳지 않은 상태 의 특성-)

  • 반호영;박상준;윤기원;최응규;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.41-44
    • /
    • 1995
  • The purpose of this study is analyze to the properties of high fluidity concrete(W/C 35~50%) with the dosage of viscosity agent(Hydroxy Propyl Methyl Cellulose ; HPMC ; 15U), From the resuls, flowability was good about 200g/㎥. segregation-resisibility and placeability were good upward 300g/㎥, To synthetic, the dosage of viscosity agent are discovered best in 200~400g/㎥

  • PDF

A Study on the Properties of High Performance Concrete Using Low Heat Portland(Type IV) Cement (저열 포틀랜드(4종)시멘트를 사용한 고유동, 고강도콘크리트에 관한 연구)

  • 최광일;김기수;하재담;김동석;이순기;이동윤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.422-429
    • /
    • 1997
  • In recent years, concrete construction have become larger and higher and are demanding high performance concrete with lower heat to prevent thermal cracking, far greater workability, high strength and durability. Application of low heat portland(Type IV) cement for the high performance concrete is the best solution to satisfied those requirements. Here are explained the basic properties of fresh concrete as well as hardened concrete of high performance concrete using low that portland cement.

  • PDF

An Experimental Study on Analysis of Concrete Properties According to the Dosage Variation of AE Superplasticizer (AE고유동화제 첨가량 변화에 따른 콘크리트의 특성분석에 관한 실험적 연구)

  • 윤기원;한천구;반호용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.04a
    • /
    • pp.19-22
    • /
    • 1992
  • Properties of concrete has effected on the dosage variation of AE superplasticizer agent, Therefore, this study is designed for analysis of concrete properies according to the dosage variation of AE superplasticizer agent , and is aimed to analyze the effect slump, air content, compressive strength, resistance of freezing-and-thawing and for presenting the reference data on the practical use.

  • PDF

A Study on the Optimum Mix Proportion for Early Strength of Concrete in the Upper Layers of High Rise Building (Part II - 80MPa) (초고층 빌딩용 상층부 콘크리트의 조기강도 확보를 위한 최적배합 도출에 관한 연구 (Part II - 80MPa를 중심으로))

  • Jeon, In-Ki;Park, Yong-Kyu;Lee, Joo-Hun;Choi, Myung-Hwa;Yoon, Gi-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.325-328
    • /
    • 2008
  • Recently increasing interest in high-rise building around the world for more than 100 floor, the trend is the increasing use of high-strength and high-flowable concrete so as of productivity improvements and cost savings to improve the performance of the early strength development. This study is to reach the optimal combination by reviewing the performance of high-rise building which is required. The results, lower the ratio of W/B was an increase in compressive strength and early strength in the use of admixture decreased in the combination of higher replacement ratio of admixture.

  • PDF

The Bond Characteristics of Deformed Bars in High Flowing Self-Compacting Concrete (고유동 자기충전 콘크리트와 이형철근의 부착특성)

  • Choi, Yun Wang;Jung, Jea Gwone;Kim, Kyung Hwan;An, Tae Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.511-518
    • /
    • 2009
  • This study was intended to compare and evaluate the adhesion of High flowing Self-compacting Concrete (HSCC), Conventional Concrete (CC) and deformed bar based on concrete strength 3 (30, 50 and 70 MPa), among the factors affecting the bond strength between concrete and rebar, after fabricating the specimen by modifying the rebar position at Horizontal reinforcement at bottom position (HB), horizontal reinforcement at top position (HT) and vertical reinforcement type (V). As a result of measuring bond strength of HB/HT rebar to evaluate the factor of the rebar at top position, the bond strength of HB/HT rebar at 50 and 70 MPa was 1.3 or less and at 30 MPa, HSCC and CC appeared to be 1.2 and 2,1, respectively. Thus, when designing the anchorage length according to the concrete structure design standard (2007) at HSCC 30, 50 and 70 MPa, it would be desirable to reduce the correction factor of anchorage length of the horizontal reinforcement at top position, which is suggested for the reinforcement at top position, to less than 1.3 of CC.