• Title/Summary/Keyword: 고유동콘크리트

Search Result 225, Processing Time 0.037 seconds

An Experimental Study on the Manufacturing and Application of High-Workable Concrete (고유동콘크리트의 제조 및 현장적용을 위한 실험적 연구)

  • 윤재환;차태환;홍순조;권지훈
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.2
    • /
    • pp.109-117
    • /
    • 1996
  • Recently, High-Workable Concrete has been developed and began to be used to a great extent in foreign countries, but it is not familiar with and fully Introduced in Korea yet. Therefore the aim of this paper is to suggest a reference data. for the development of High-Workable Concrete according to the comparative analysis which were done on the effects of mix proportion(water-binder ratio, sand-aggregate ratio, unit water, a kind of superplasticizer) on the flowing characteristics. And also this paper aims to examine the compactability and segregation resistance of High-Workable Concrete in a mock-up test and in a field test. From the result, we concluded that it is possible to produce and to use the High-Workable Concrete at the construction site.

Flexural Behavior of RC Beams made of High Flowing Self-Compacting Concrete with Normal Strength (보통강도 고유동 자기충전 철근 콘크리트 보의 휨거동)

  • Choi, Yun-Wang;Kim, Jee-Sang;Chu, Seok-Beom;Lee, Haeng-Ki;An, Tae-Ho;Ha, Sung-Kug
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.349-352
    • /
    • 2008
  • The research conducts a four-point loading test by making two reinforced concrete beams(HSCC test specimen and conventional concrete test specimen) in order to apply an HSCC with a normal strength(30MPa) to a structure. Also, it compares and analyzes the characteristics of the flexural behavior of HSCC and conventional concrete. The stiffness and ductility of the test specimens of HSCC and conventional concrete show similar behavior, but HSCC is more effective in crack control than conventional concrete. The result of the research demonstrates that HSCC can be applied in the construction site.

  • PDF

New Method for evaluation the Segregation Resistance of High-Fluidity Concrete (고유동 콘크리트의 새로운 재료분리 저항성 평가방법에 관한 제안)

  • 한천구;김기철
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.2
    • /
    • pp.147-154
    • /
    • 1998
  • 고유동 콘크리트의 특성을 판정하기 위한 방법으로서 기존에 알려진 재료분리 판정 방법은 매우 복잡하고 번거로운 실험방법으로 실무 적용에 많은 어려움이 있다. 그런데, 고유동 콘크리트의 유동성 측정 방법에는 슬럼프 플로우를 주로 측정하고, 슬럼프는 변화가 작아서 배제되고 있는 실정이나, 재료분리된 양상을 살펴보면 슬럼프 플로우는 큰 반면, 슬럼프는 작은 양상을 보이고 있다. 따라서 본 연구에서는 고유동 콘크리트의 재료분리 저항성을 슬럼프와 슬럼프 플로우의 조합으로 간단히 평가할 수 있는지 그 가능여부를 검토하고자 하였다. 연구 결과 슬럼프 플로우에 대한 슬럼프의 비는 양호한 재료분리의 평가지표로 이용할 수 있는데, 이 값을 2.5 이하로 유지하면 실무에서의 고유동 콘크리트는 양호한 재료분리 저항성을 관리할 수 있을 것으로 사료된다.

An Experimental Study on the Properties of High Flowing Concrete according to Water/Binder Ratio(W/B) (물결합재비에 따른 고유동콘크리트의 특성에 관한 실험적 연구)

  • 김무한;최세진
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.4
    • /
    • pp.329-335
    • /
    • 2001
  • Recently, in many laboratories and institutes it is being studied on the high flowing concrete widely, which has high fluidity, non-segregation ability and fillingability, and sometimes being applied to the construction field actually. And the fluidity properties of high flowing concrete are influenced according to the several factors ; binder content, water/binder ratio and water content etc. This is an experimental study to compare and analyze the effect of water/binder ratio and water content on the properties of high flowing concrete. For this purpose, the mix proportion of high flowing concrete according to water/binder ratio(W/B : 0.30, 0.35, 0.40, 0.45) and water content (W : 155, 165, 175, 185 kg/㎥) was selected. And then slump-flow, V-lot, L-passing test in fresh concrete, and compressive strength, freezing and thawing test in hardened concrete were peformed. According to test results, it was found that the viscosity of all those high flowing concrete with the water content 175 kg/㎥ was satisfied with 50 cm pass time of slump flow prescribed by Japanese Architectural Standard Specification (JASS 5) - from 3 to 8 seconds. And non-segregation ability of concrete with W/B 0.35 was better than the other mix proportions. Especially, the compressive strength after curing 24 hours(1 day) of all high flowing concrete was higher than that prescribed by JASS 5(50 kgf/㎠).

Hydration Heat Properties of High Flowing Self-Compacting Concrete with Normal Strength (보통강도 고유동 자기충전 콘크리트의 수화발열 특성)

  • Choi, Yun-Wang;Kim, Byoung-Kwon;Lee, Jae-Nam;Ryu, Deug-Hyun;Song, Yong-Kyu;Jung, Woo-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.497-500
    • /
    • 2008
  • This research carries out experiments for hydration exothermic rate and adiabatic temperature rise of concrete to examine the characteristics of the hydration heat of high flowing self-compacting concrete with a normal strength. As a result of the hydration exothermic rate experiment, the high flowing self-compacting concrete that used Lime stone powder and fly ash as polymers shows that its hydration heat amount reduces due to the reduction of unit cement. The result measured the adiabatic temperature rise of concrete presents that high flowing self-compacting concrete having lots of binder contents has a good performance in temperature reduction due to the effect of polymer and that triple adding high flowing self-compacting concrete has a similar temperature rise speed with conventional concrete. As a result of the research, high flowing self-compacting concrete shows a better temperature reduction performance for the binder content per unit than conventional concrete. In addition, it is judged that triple adding high flowing self-compacting concrete with a specified concrete strength 30 MPa is more beneficial in temperature reduction and early hydration heat than double adding high flowing self-compacting concrete.

  • PDF

Evaluation of Filling Performance of Steel Concrete Panel (SCP) Mock-up Member with Low-binder based High-fluidity Concrete (저분체 기반 고유동 콘크리트의 Steel Concrete Panel Mock-up 부재 충전 성능 평가)

  • Park, Gi Joon;Park, Jung Jun;Kim, Sung Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.4
    • /
    • pp.477-483
    • /
    • 2019
  • Recently, precast type SCP modules are being used instead of PSC structures in order to reduce the construction period and costs of special structures such as nuclear power plants and LNG storage tanks. The inside of the SCP module is connected with a stud for the integral behavior of the steel and concrete, and the use of high fluidity concrete is required. High fluidity concrete generally has a high content of binder, which leads to an increase in hydration heat and shrinkage, and a problem of non-uniform strength development. Therefore, in this study, fluidity and passing performance of high fluidity concrete according to material properties are investigated to select optimum mix design of low binder based high fluidity concrete. Mechanical properties of high fluidity concrete before and after pumping are examined using pump car. The filling performance of SCP mock-up members was evaluated by using high fluidity concrete finally.

A Study on the Quality Properties of Exposed High Fluidity Concrete using Fly Ash and Limestone Powder (플라이애시 및 석회석 미분말을 사용한 고유동 노출 콘크리트의 품질특성에 관한 연구)

  • Choi, Yun-Wang;Oh, Sung-Rok;Kim, Ji-Hoon;Kim, Kyung-Hwan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.1
    • /
    • pp.67-75
    • /
    • 2013
  • Recently, the interest is increasing about the exposed concrete, accordingly, exposed concrete is expanding the use. However, concrete structures is difficult to apply the general concrete for exposed concrete, due to complex section and compact reinforcement, increasingly. Therefore, in this paper, for application of high fluidity concrete as exposed concrete, exposed high fluidity concrete using fly ash and lime stone powder was manufactured and observed quality property(fluidity properties, mechanical properties and Surface Properties) of exposed high fluidity concrete. The experiments are based on the OPC and LSP10, was evaluated Impact on the quality of concrete according to mixing ratio of FA(0, 10, 15 and 20). As a result, fluidity properties, mechanical properties and Surface Properties of exposed high fluidity concrete were satisfied to requirement conditions, fluidity and surface finishability was improved depending on mix of fly ash and limestone powder. Through this, we utilize of basic research data for development of high fluidity concrete for exposed concrete.