• Title/Summary/Keyword: 고온 열적 특성

Search Result 249, Processing Time 0.022 seconds

An Analysis of Thermal Conductivity of Ceramic Fibrous Insulator by Modeling & Simulation Method I (모델링/시뮬레이션 기법을 이용한 세라믹 섬유 단열재의 열전도도 해석 I)

  • Kang, Hyung;Baek, Yong-Kee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.83-95
    • /
    • 2002
  • Thermal conductivity of ceramic fibrous insulator was analysed and predicted by using the modeling/simulation technique. Ceramic fibrous insulators are widely used as high temperature insulator on account of their lightweight mass and heat resisting properties. Especially it is suitable to protect the high speed aircraft and missiles from severe aero-thermodynamic heating. Thermal conductivity of ceramic fibrous insulator could be determined from the conductive heat transfer and the radiative heat transfer through the insulator. In order to estimate conductive thermal conductivity, homogenization technique was applied, while radiative thermal conductivity was computed by means of random number and radiation probability. Particularly radiation probability can make it possible to estimate the conductivity of fibrous insulator without any experimental constant. The calculated conductivity predicted in the present study have a reasonable accuracy with an average error of 7 percent to experimental data.

Thermal and Electrical Properties of Poly(vinylidenefluoride-hexafluoropropylene)-based Gel-Electrolytes (Poly(vinylidenefluoride-hexafluoropropylene)계 겔-전해질의 열적, 전기적 특성)

  • 김영완;최병구;안순호
    • Polymer(Korea)
    • /
    • v.24 no.3
    • /
    • pp.382-388
    • /
    • 2000
  • Polymer electrolyte films consisting of poly(vinylidenefluoride-hexafluoropropylene) (PVdF-HFP), LiClO$_3$ and a mixture of ethylene carbonate (EC) and ${\gamma}$-butyrolactone (GBL) were examined in order to obtain the best compromise between high ionic conductivity, homogeniety, dimensional and electrochemical stability. Measurements of ionic conductivity, differential scanning calorimetry and linear sweep voltammetry have been carried out for various compositions. The highest conductivity of 3.8$\times$10$^{-3}$ S$cm^{-1}$ / at 3$0^{\circ}C$ were obtained for a film of 30(PVdF-HFP)+7.8LiClO$_4$+62.2EC/GBL. From the DSC study, it has been found that the PVdF-HFP gels are stable up to 10$0^{\circ}C$, and the salt lowers the melting temperature of crystalline part of PVdF by interacting sensitively with polymer segments. When Lithium metal is in contact with the gel films, it tends to undergo corrosion and the reaction products accumulate resulting in the formation of a passive film on Li electrode. As the aging time progresses, the interfacial resistance increases continuously. Anodic stability is measured to extend up to about 4.5 V vs. Li.

  • PDF

Heat Resistant Electromagnetic Noise Absorber Films Using Poly(amide imide)/Soft Magnet Composite (내열성 전자기 노이즈 흡수 폴리(아미드-이미드)/연자성체 복합체 필름)

  • Han, Ji-Eun;Jeon, Byung-Kuk;Goo, Bon-Jae;Cho, Seung-Hyun;Kim, Sung-Hoon;Lee, Kyung-Sub;Park, Yun-Heum;Lee, Jun-Young
    • Polymer(Korea)
    • /
    • v.33 no.1
    • /
    • pp.91-95
    • /
    • 2009
  • We fabricated the electromagnetic (EM) noise absorber films for high temperature use by blending a soft magnetic powder with poly(amide imide) (PAI). The EM noise absorber films of PAI/soft magnet composite were prepared by casting the solution of poly(amide amic acid)/soft magnet powder into glass substrate with casting applicator device and then thermal imidization. The obtained films were fully characterized and their physical properties including thermal behavior, thermal stability and mechanical properties were studied. The EM noise absorption ability was also investigated using micro-strip line method. At 1 GHz, the power loss of composite film with 150 ${\mu}m$ thickness was about 25%.

Estimation of Flood Discharge using Satellite-derived Rainfall in Abroad Watershed (위성강우를 이용한 해외 유역 홍수량 추정)

  • Kim, Joo Hun;Choi, Yun Seok;Kim, Kyeong Tak
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.250-250
    • /
    • 2017
  • 글로벌 위성 기반의 강수량 관측에 대한 역사는 1979년에 Arkin의 의해 제안된 IR방법에 의해 위성으로부터 강우자료를 유도하는 개념이 도입된 이후 1987년 해양에서의 비교적 정확한 강수량 추정이 가능한 다중 채널의 마이크로파(MW) 복사계를 이용한 방법으로 위성강수 추정에 대한 연구가 활발히 진행되었다. 이후 두 IR과 MW를 혼합한 방법에서, 또다시 1997년 TRMM위성의 PR(Precpipitation Radar)의 레이더를 이용하는 방법, 그리고 2014년 GPM 핵심 위성(GPM Core Observatory)에 탑재된 Dual PR에 의한 방법으로 위성강수의 정확도를 매우 높여가고 있다. 본 연구는 KOICA 사업으로 진행중인 모로코 세부강 유역 홍수방지 마스터플랜 사업에서 모로코 세부강 유역의 2010년 홍수사상에 대한 위성강우 및 지상계측 일일자료를 이용하여 홍수유출량을 추정하는 것으로 목적으로 하고 있다. 모로코 세부강(Oued Sebou) 유역은 모로코의 서북부에 위치하며 유역면적은 한강유역과 유사한 $38,380km^2$이고 하천연장은 450km로 모로코 국토면적의 약 7% 정도를 차지하며 모로코 농업생산의 중심지역이고 유역의 기후 및 기상 특성은 겨울철 온난다습하고 여름에 고온 건조한 지중해성 기후를 나타내며, 연강수량은 400mm이상으로 보고하고 있다(이산 등, 2015). 유역내 49개 관측소의 일일 강우량 자료를 분석한 결과 2000년부터 2010년까지의 유역 산술평균 강수량은 607.1mm/yr로 분석되었고, 2010년 가장 많은 강수를 기록한 지역은 Jbel oudka로 1874.1mm/yr였고, 가장 적은 강수량을 기록한 지역은 Allal Al Fassi - Barrage로 289.9mm/yr로 나타났다. 2010년 홍수가 발생한 시기인 2009년 12월 19일부터 2010년 1월 18일까지의 1시간 간격의 위성강우자료와 1일 관측 지상계측자료를 합성하여 위성보정강우량을 추정하였다. 보정 방법은 순위상관방법을 적용하였다. 사용한 모형은 일본 ICHARM에서 개발한 IFAS와 한국건설기술연구원의 MapWindow 기반 GRM 모형(mwGRM)을 이용하였다. 모형의 적용 결과 세부강 유역 본류의 첨두유출량은 $6,010m^3/s$(mwGRM)과 $5,878m^3/s$(IFAS)로 분석되었다. 향후 위성강우 및 지상계측 강우의 시계열적 정확도와 총강우량 등의 정확도 평가를 수행할 계획이다.

  • PDF

A Study on Variable Conductance Radiator using Liquid Metal for Highly Efficient Satellite Thermal Control (인공위성의 고효율 열제어 구현을 위한 액체금속형 가변 전도율 방열판에 관한 연구)

  • Park, Gwi-Jung;Go, Ji-Seong;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.2
    • /
    • pp.66-72
    • /
    • 2019
  • The observation satellites which uses high heat-dissipating equipment such as synthetic aperture radar (SAR) satellites require a radiator to transmit heat from the equipment into outer space. However, during cold conditions it requires a heater to maintain the temperature of equipment within the allowable minimum limit when it is not in operation. In this study, we proposed a variable conductivity radiator that changes its thermal conductivity value through movement of the liquid metal between two reservoirs based on the temperature condition. This reduces the power consumption of the heater by limiting heat transfer path to the radiator in cold condition, while effectively transferring heat to the radiator during hot condition. The feasibility of the proposed radiator was validated through comparison of the thermal control performance with the conventional fixed conductivity radiator via a thermal analysis.

A Study on Heating Element Properties of Carbon Nanotube/Silicon Carbonitride Composite Sheet using Branched Structured Polysilazane as Precursor (가지 달린 구조의 폴리실라잔을 전구체로 이용해 제조한 카본 나노튜브/실리콘 카보나이트라이드 복합체 시트의 발열특성에 관한 연구)

  • Huh, Tae-Hwan;Song, Hyeon Jun;Jeong, Yeong Jin;Kwark, Young-Je
    • Composites Research
    • /
    • v.33 no.6
    • /
    • pp.395-400
    • /
    • 2020
  • In this paper, we manufactured silsesquiaznae (SSQZ)-coated carbon nanotube (CNT) surface heating elements, which allowed stable heating at high temperatures. The prepared composite sheet was confirmed by FE-SEM that the SSQZ fully coated the surface of CNT sheet. Furthermore, it was also confirmed that the silicon carbonitride (SiCN) ceramic formed by heat treatment of 800℃ have no defects found and maintain intact structure. The CNT/SiCN composite sheet was able to achieve higher thermal stability than raw CNT sheets in both nitrogen and air atmosphere. Finally, the CNT/SiCN composite sheet was possible to heat up at a temperature of over 700℃ in the atmosphere, and the re-heating was successfully operated after cooling.

Enhanced Oxidation Resistance of LSI-Cf/SiC Composite by De-siliconization (탈규소화를 통한 LSI-Cf/SiC 복합재료의 내산화성 향상)

  • Jung Hwan Song;Jung Hoon Kong;Seung Yong Lee;Young Il Son;Do Kyung Kim
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.6
    • /
    • pp.21-27
    • /
    • 2022
  • Cf/SiC composites have low density, high mechanical strength, and good thermal stability, making them promising materials for high-temperature applications such as rocket propulsion and military fields. However, the remaining Si deteriorates physical and thermal properties. In this paper, the de-siliconization was introduced as a method to remove the Si of the Cf/SiC composite fabricated through Liquid Silicon Infiltration(LSI) process. The stability of composite has been tested under an oxyacetylene torch flame for up to 5 minutes. The oxidized surface and cross section of specimens were characterized by 3D scanning, X-ray diffraction(XRD), Optical microscope(OM) and Scanning electron microscope(SEM).

A Study on Fabrication and Characterization of Inorganic Insulation Material by Hydrothermal Synthesis Method (2) (수열합성법을 이용한 무기계 단열소재 제조방법 및 특성에 관한 연구 (2))

  • Seo, Sung-Kwan;Chu, Yong-Sik;Lee, Jong-Kyu;Song, Hun;Park, Jae-Wan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.225-232
    • /
    • 2013
  • The inorganic insulating material was fabricated with quartzite, ordinary portland cement(OPC), lime, anhydrous gypsum and foaming agent by hydrothermal reaction. The inorganic insulating material was fabricated by using autoclave chamber under high-temperature and high-pressure. The inorganic insulating material is a porous lightweight concrete. Because of its porous structure, properties of inorganic insulating material were light-weight and high-heat insulation property. Properties of fabricated inorganic insulating material were $0.26g/cm^3$ in specific gravity, 0.4MPa in compressive strength and 0.064W/mK in thermal conductivity. In this study, the inorganic insulating material was fabricated and analyzed at different size of quartzite/OPC, various foaming reagent and functional additives to improve the properties. Consequently, polydimethylsiloxane can improve density and thermal conductivity. Especially, polydimethylsiloxane showed excellent improvement in compressive strength.

Growth and Characterization of Ultra-Thin $TiO_2$Film on Mo(100) Surface (Mo(100) 표면에 $TiO_2$초박막의 성장과 특성)

  • Kim, Dae Young
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.5
    • /
    • pp.223-233
    • /
    • 1997
  • Ultra-thin $TiO_2$ films are grown on the Mo(100) surface using evaporated Ti metal under ambient $O_2$ pressure. The thickness of the $TiO_2$ film is controlled by the dosing rate of Ti metal over Mo(100) which is determined from the Auger signal changes with dosing time. 30 ML, 5 ML, and 1.6 ML thick films are prepared and used to determine the growth mechanism, the chemical composition, and the surface structure of the films. The growth mechanism of the $TiO_2$ film on Mo(100) is observed to follow the layer-by-layer growth mechanism. The chemical composition of the film is found to be that of bulk $TiO_2$. The surface plane of the film is (001), which facets irreversibly at 1200 K. The LEED pattern obtained from the film can be explained with the faceted surface with {011} planes reconstructed to $(2\sqrt2{\times}\sqrt2)R45^{\circ}$ with respect to the $TiO_2$ (001) surface. The film is somewhat thermally unstable when annealed to 1300 K. The film sputtered with $Ar^+$ ion is also studied by XPS.

  • PDF

Analysis of Abnormal High Temperature Phenomena in Cixi-si of China using Landsat Satellite Images (Landsat 위성영상을 이용한 중국 츠시시의 이상 고온 현상 분석)

  • Park, Joon-Kyu;Lee, Jong-Sin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.34-40
    • /
    • 2017
  • In recent years, global warming has caused abnormal weather phenomena. Unusually cold climates have occurred all around the world, including cold waves in the Northeastern United States, Beijing, China, Southern India, and Pakistan, as well as floods in Chile, Kazakhstan, and Vietnam. China has been experiencing a nationwide heat wave annually since the year 2013, especially in the southern region. In this study, we used Landsat 8 OLI TIRS sensor images from four periods to analyze the characteristics of abnormal high temperature phenomena in Cixi-si, China. Land cover classification was performed using 10 bands of satellite imagery, and the surface temperature was extracted using the 10th thermal band. The results of the land cover classification of the fourth period show the changes of the time series quantitatively. The results of the surface temperature calculation provided both the average overall temperature and the average temperature of individual items. The temperature was found to be highest for buildings, followed by grassland, forest, agricultural land, water systems, and tidal flats in the same period.