• Title/Summary/Keyword: 고온공기

Search Result 420, Processing Time 0.031 seconds

The properties of algal degradation and gas emission by thermophilic oxic process (고온호기발효장치를 이용한 조류 분해 및 가스 발생특성)

  • Kang, Changmin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.7 no.2
    • /
    • pp.57-64
    • /
    • 1999
  • The purpose of this study is to establish effective conditions for controlling $CH_4$, $N_2O$ emission from organic Waste / wastewater treatment processes. Continuous and batch experiments were conducted to treat the micro algae from polluted and eutrophicated lakes through the thermophilic oxic process. The microalgae used were mainly Microcystis sp.(collected from eutrophic lake) and Chlorella sp. (cultured in laboratory) Wasted cooking oil was added by aid-heating source. Physico-chemical components of sludges and microalgae were analyzed. In batch experiments, air supply was changed from 50ml/min to 150ml/min. The temperature. water content and drained water were affected by the air flow rate at initial stage. However, there was almost no influence of air flow rate on them in middle and last stages. At air flow rate of 100ml/min, the degradation rate of organic material was higher than that at other air flow rates. $CO_2$ concentration in exhaust was proportional to the strength of aeration, especially at initial stage when degradation was active. $CH_4$ with low concentration was detected only at starting stage when air diffusion was not enough. $N_2O$ production was not affected by variation of air supply. In continuous experiments no matter what the dewatering methods (with PAC and without PAC) and media (wood chip and reed chip) were changed, $N_2O$ was almost not affected by variation of injected air. Result showed that the reed chips using for lake purification could be used as media for thermophilic oxic process in lake and marshes area. $CO_2$ concentration was not so much affected by the change of dewatering methods and media types. $CH_4$ was not detected in the experimental period. So it can be shown that the thermophilic oxic process had been well operated in wide handling conditions regardless of media and dewatering methods.

  • PDF

Development of MBOP for 125 kW Molten Carbonate Fuel Cell (125kW급 용융탄산염 연료전지 MBOP 개발 및 성능평가결과)

  • Kang, Seung Won;Lee, Junghyun;Kim, Beumju;Kim, Do-Hyung;Kim, Eui-Hwan;Lim, Hee Chun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.130.2-130.2
    • /
    • 2010
  • 한전 전력연구원에서는 2009년 12월부터 125 kW급 용융탄산염 연료전지 발전시스템의 성능평가를 위한 운전이 진행되고 있다. 현재 진행 중인 "250 kW급 열병합 용융탄산염 연료전지 Proto Type개발" 과제의 최종시작품인 250 kW급 발전시스템은 125 kW급 MCFC 스택 2기로 설계되어, 125 kW급 시스템의 시험운전은 매우 중요한 기술적 성과가 될 것이다. 현재 125 kW급 MCFC 스택은 10,000 $cm^2$의 유효전극면적을 갖는 단위전지들로 구성되었으며, 적층 스택의 온도 및 농도분포의 최적화를 위해 내부 매니폴드 및 Co-flow Type 열교환기 기반의 분리판을 개발 적용하였다. 연료극의 전극 구성은 Ni-Al alloy로, 공기극의 전극 구성은 Lithiated-NiO로 이루어졌다. 그리고 매트릭스는 ${\alpha}-LiAlO_2$로 제작되었고, 전해질은 Li과 K Carbonate가 68 : 32 비율로 섞인 용융염을 사용하였다. 본 125 kW급 용융탄산염 연료전지 시스템의 운전평가는 고적층 스택의 온도 및 농도 분포를 확인하고, 최적화된 스택 운전 조건을 도출하는 것을 그 목적으로 하고 있다. 125kW급 스택 1기의 규모의 주변기기 시스템은 외부개질기, 촉매연소기, 이젝터, 고온순환 블로어 및 공기블로어 등으로 이루어져 있다. 고온형 연료전지 시스템에서 연료극과 공기극의 균일한 온도 및 압력 확보는 매우 중요하며, 이를 위하여 외부개질기 및 촉매연소기 연동을 통한 온도편차를 최소화하고, 기존 고온용 순환 블로어 대신 이젝터를 개발 도입하여 압력균형을 조절하였다. 125kW급 MCFC 시스템은 2009년 12월부터 전처리 운전을 시작하여 2010년 1월 말부터 PCS로 전기를 생산하고 있다. 평균전압 0.83V에서 100kW의 출력을 기록하였으며, 피크부하 120 kW, 누적출력량 30 MWh를 초과달성하였다.

  • PDF

CrN/AlSiN multilayer coatings의 고온안정성 및 특성에 관한 연구

  • Kim, Yeong-Su;Kim, Gwang-Seok;Kim, Seong-Min;Heo, Yong-Gang;Lee, Sang-Yul
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.47-47
    • /
    • 2008
  • Cr and AlSi (Si=20 and 66 at.%) target들을 이용하여 Closed-field unbalanced magnetron sputtering (CFUBMS)으로 증착된 주기($\Lambda$)가 2.3 nm에서 8.0nm인 CrN/AlSiN multilayer coatings의 crystal structure, 화학적 조성, 및 기계적 특성을 glow discharge optical emission spectroscopy (GDOES), X-ray diffractometry (XRD), X-ray photoelectron spectroscopy (XPS) and nano-indenter 등의 분석장비를 이용하여 분석하였다. 고온안정성을 시험하기 위하여 $800^{\circ}C$$1000^{\circ}C$ 공기중 에서 30분 열처리하였다. CrN/AlSiN multilayer coatings의 고온안정성은 Si조성이 증가함에 따라 향상되었다. Si이 18.2 at.%함유된 coating이 가장 우수한 고온안정성을 갖고 있다.

  • PDF

반점세균병$\cdot$담배나방 (고추 장마철에 이런 병$\cdot$해충이 문제된다. - 돌림병$\cdot$검썩음병$\cdot$바이러스병$\cdot$반점세균병$\cdot$담배나방)

  • 신현욱
    • The Bimonthly Magazine for Agrochemicals and Plant Protection
    • /
    • v.7 no.4
    • /
    • pp.72-79
    • /
    • 1986
  • 우리 식생활에 없어서는 안되는 양념 채소인 고추는 이른 봄부터 늦가을까지 재배기간이 긴 작물로서 특히 고온다습한 장마철에 방제하기가 어려운 병충해의 발생이 심한 것으로 장마철의 주요 병해충을 보면 돌림병(疫病)을 비롯해서 검썩음병과 바이라스, 반점세균병 그리고 담배나방을 들 수 있다. 이들 중 가장 무서운 피해를 주는 것은 연작포장에서 심하게 발생되는 역병과 고온다습한 공기를 타고 급격히 전염되는 탄저병 그리고 반점세균병과 진딧물이 매개하는 바이러스 즉, 오갈병과 연중 3$\~$4회 발생하여 피해를 주는 담배나방이 있다.

  • PDF

Experimental Study on High Temperature Air Regenerative Combustion System (축열식 고온공기 연소시스템에 대한 실험적 연구)

  • Yang, B.O.;Lim, I.G.
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.189-200
    • /
    • 1999
  • Combustion characteristics of a regenerative combustor for high temperature air combustion have experimentally studied. Temperature measurement on regenerative ceramic material and combustor has been carried out with changing equivalence ratio at constant turn-over period. Stable and unstable combustion region have been found and also detailed averaged temperature profile with respect to various air flow conditions have been obtained.

  • PDF

A Study on the Entrance Region Fouling of Sludge Incinerator Air-preheater at IronWorks (제철슬러지 소각로의 공기예열기 입구의 파울링특성 연구)

  • 박상일;김정근
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.557-562
    • /
    • 2003
  • 산업체 소각로의 고온 배가스에는 소각물질의 특성에 따라 다양한 성분의 오염물질이 함유되어 있다. 고온 소각배가스의 후처리를 위하여 배가스냉각용 열교환기가 사용되고 있다. 그러나, 소각로 열교환기의 입구와 전열면에 파울링 현상이 발생하여 열교환기의 전열성능이 감소하고 또한 심한 경우, 유로면적이 줄어들어 통풍저항이 증대된다.(중략)

  • PDF

The Study on Aerodynamic Characteristics for the Design of High Efficiency Jet Vane (고 효율 제트 베인 설계를 위한 공기역학적 특성 연구)

  • 길경섭;정용갑;박종호
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.4
    • /
    • pp.39-45
    • /
    • 2003
  • Of the various means for active trajectory correction, a thrust vector control system represents the only principle independent of missile external forces so that this method is operative. The purpose of this study is to analyze the characteristic of jet vane TVC(Thrust vector control) system among mechanical jet deflection. To ensure high performance leading edge shape, aspect ratio and ablated condition is optimized. Supersonic flow system, jet vanes and nozzle with Mach number 2.88 and under expansion ratio 2 were designed to study aerodynamic characteristics of leading edge shape, aspect ratio and ablated conditions.

An Experimental Study for performance evaluation of a ceramic heat exchanger (세라믹 열교환기의 성능 평가를 위한 실험적 연구)

  • Choe, Hyeon-Su;Sin, Dong-Hun;Jeong, Tae-Yong;Park, Sang-Hwan
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2010.04a
    • /
    • pp.44-44
    • /
    • 2010
  • 대부분의 산업분야에서 사용되는 공업로는 연소 시 $1000^{\circ}C$이상의 고온 배기가스가 배출되고 있기 때문에, 이들 배기가스로부터 폐열을 회수하여 에너지를 절감하고자 열교환기를 사용하고 있다. 하지만 현재 사용되고 있는 금속 소재의 열교환기의 경우 사용온도가 $800^{\circ}C$로 제한되어 있으며, 산화, 부식, creep등의 문제가 대두되고 있다. 본 연구에서는 세라믹 소재의 열교환기를 제작하여 열전달율, 공기누설율등을 평가하는 성능실험을 하였다. 실험방법은 연소시작 후 정상상태에 도달하기까지의 경향을 알아보고 공기유량과 가스유량에 변화를 주었을 때, 열전달율과 공기누설율등을 평가하고 이론적인 데이터와 비교하였다. 실험 결과, $1300^{\circ}C$이상의 환경에서도 정상적으로 작동하였으며, 외부환경조건을 고려하였을 때, 이론적인 데이터와 근접한 데이터를 얻을 수 있었다. 그러나 대류열전달에 의한 열손실과 공기누설등이 문제점으로 지적되었다. 향후 연구에서는 대류열전달에 의한 열손실을 고려한 연구와 효과적인 씰링으로 누설을 줄일 수 있는 실험장치를 개발할 필요가 있다.

  • PDF

A Study on the Optimization of Ventilation Fan Position and Flow Rate for a Turbine Building of a Power Plant (화력발전소 터빈 본관의 환풍기 위치 및 용량 최적화에 관한 연구)

  • Kim, T.K.;Ha, J.S.;Park, C.H.
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.86-93
    • /
    • 2016
  • The existence of high temperature equipment such as steam pipe, deaerator, steam storage tanks and main steam stop valves makes relatively higher workplace temperature in a power plant of the turbine building. In order to cool down the air temperature in the turbine building, the outside air flow with lower temperature passes through the window and the hotter air in the building is extracted to the outside by installing the ventilation fan on the roof. Nevertheless, higher temperature regions near the high temperature equipment still exist in the turbine building and additional fans for the temperature reduction in the higher temperature region should be examined for the optimal location and mass flow rate. The purpose of the present study is to suggest the optimized location and capacity of the additional ventilation fans for a comfortable working environment. From the present study, it has been elucidated that the additional ventilation fans might be located near the high temperature deaerator and it could reduce the mean temperature in the turbine building by $3.0^{\circ}C$ and the temperature near the deaerator could be reduced by $4.2^{\circ}C$.