• Title/Summary/Keyword: 고신호광도

Search Result 9, Processing Time 0.025 seconds

Clinical Correlates of Subcortical Hyperintensities on Magnetic Resonance Imaging in Patients with Bipolar Disorder : Preliminary Study (양극성장애 환자의 뇌자기공명영상에서 보이는 피질하 고신호광도의 임상적 상관변수에 관한 예비적 연구)

  • Yoon, Dae Hyun;Kwon, Jun Soo;Han, Moon Hee;Chang, Kee Hyun
    • Korean Journal of Biological Psychiatry
    • /
    • v.4 no.1
    • /
    • pp.60-66
    • /
    • 1997
  • Objective : Accumulating evidence suggests a greater number of subcortical hyperintensities in the brain of patients with bipolar disorder. We studied the Clinical correlates of subcortical hyperintensities on magnetic resonance imaging in patients with Bipolar Disorder : Methods : Magnetic resonance images of the brain were obtained for 32 patients with bipolar disorder. The presence and location of hyperintensities were assessed. We compared clinical variables between patients with subcortical hyperintensities and patients without them. Results : Seven patients(21.8%) had subcortical hyperintensities, but among 8 patients who were 40 years or older, 5 patients(62%) had them. Age and age at onset of patients with subcortical hyperintensities were significantly older than patients without them. Psychotic symptoms were more frequent in patients with hyperintensities. Patients without hyperintensities had more familial loadings. Conclusion : Given the limitations of the study, our results should be seen as preliminary. This study, however, provides preliminary evidence supporting the notion that the onset, clinical feature and course of some bipolar disorders of late onset may be determined by underlying subcortical abnormalities, with such abnormalities being the consequence of factors related to aging or neurodegeneration(such as impaired cerebral circulation) rather than genetic factors which predispose to early-onset bipolar disorders.

  • PDF

Improvement Effects on Lock-in Thermography by Iterative Adaption in Optical Excitation (광학가진의 반복 정합에 의한 위상잠금 열화상 개선 효과)

  • Kim, Won Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.376-381
    • /
    • 2013
  • 위상잠금 열화상에서는 일반적으로 변조된 주파수의 광램프를 쓰고 있다. 하지만 램프의 광도 분포는 입력신호가 평단(flat)특성임에 불구하고 심지어 불균일하여 검사 시편내에 측면 열유동을 만들어낸다. 이러한 열유동은 원치 않는 효과로서 측면의 분해능을 감소시키는 등과 같이 관심 결함구조의 영상에 부정적인 영향을 미친다. 본 고에서 검토되는 방식은 열원으로서 LCD 프로젝터와 같은 것을 이용하여 각 가진픽셀에 개별적으로 진동진폭, 광도 오프셋, 위상지연 등을 할당하는 방법에 대한 접근기술이다. 이러한 반복적인 자체학습 과정에 의한 조명 패턴을 통하여 측면 열유동이 제거되고 분해능이 향상되도록 제공하는 것이다.

Comparison of Electrical Signal Properties about Top Electrode Size on Photoconductor Film (광도전체 필름 상부 전극크기에 따른 전기적 신호 특성 비교)

  • Kang, Sang-Sik;Jung, Bong-Jae;Noh, Si-Cheul;Cho, Chang-Hoon;Yoon, Ju-Sun;Jeon, Sung-Pyo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.93-96
    • /
    • 2011
  • Currently, the development of direct conversion radiation detector using photoconductor materials is progressing in widely. Among of theses photoconductor materials, mercuric iodide compound than amorphous selenium has excellent absorption and sensitivity of high energy radiation. Also, the detection efficiency of signal generated in photoconductor film varies by electric filed and geometric distribution according to top-bottom electrode size. Therefore, in this work, the x-ray detection characteristics are investigated about the size of top electrode in $HgI_2$ photoconductor film. For sample fabrication, to solve the problem that is difficult to make a large area film, we used the spatial paste screen-print method. And the sample thickness is $150{\mu}m$ and an film area size is $3cm{\times}3cm$ on ITO-coated glass substrate. ITO(Indium-Tin-Oxide) electrode was used as top electrode using a magnetron sputtering system and each area is $3cm{\times}3cm$, $2cm{\times}2cm$ and $1cm{\times}1cm$. From experimental measurement, the dark current, sensitivity and SNR of the $HgI_2$ film are obtained from I-V test. From the experimental results, it shows that the sensitivity increases in accordance with the area of the electrode but the SNR is decreased because of the high dark current. Therefore, the optimized size of electrode is importance for the development of photoconductor based x-ray imaging detector.

The Driving Circuit Design for the LED Traffic Signal Lamp (에너지 절약형 LED 신호등 구동회로 설계에 관한 연구)

  • Jeong, Hak-Geun;Jung, Bong-Men;Yu, Seung-Weon;Park, Suk-In
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3144-3146
    • /
    • 1999
  • $8{\sim}12$인치의 원형(또는 사각) PCB 기판에 수백 개의 고휘도 반도체 발광 다이오드(Light Emitting Diode. LED)와 구동 회로로 구성되는 LED 교통 신호등은 특정 파장대의 단색광을 발광하므로, 기존의 백열전구식 신호등에 비해 시인성이 좋고, 80 % 이상의 에너지 절약이 가능하다. 그러나 LED는 주위 온도에 따라 밝기가 변화하는 특성이 있다. 신호등은 기능상 외부 온도의 영향 없이 항상 일정한 광도를 유지해야 하므로, 본 논문에서는 외부 온도의 변화에 관계없이 일정한 광출력을 유지할 수 있는 LED 구동회로를 설계한다 이를 위해 정전압 및 정전류로 구동되는 LED의 온도에 따른 광출력 특성 실험이 수행되고, 이러한 데이터들을 바탕으로 정광출력 LED 신호등 구동회로가 설계되고 그 성능을 평가한다.

  • PDF

The Feasibility Study of photoconductor materials for the use of a dosimeter in Radiotherapy (광도전체 물질의 치료 방사선 선량계 적용을 위한 가능성 연구)

  • Jang, Giwon;Shin, Jungwook;Oh, Kyungmin;Park, Sungkwang;Kim, Jinyoung;Park, Jikoon;Nam, Sanghee
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.81-84
    • /
    • 2013
  • The use of the dosimetry have been increasingly recognized as high radiation energy and radiation treatment planning(RTP) have rapidly developed in radiotherapy. There are many types of detectors for the dosimetry such as ionization chamber, film, TLD, diode, and etc. Among such detectors, the diode detector uses a photoconductor materials that generate electrical signals by the incident radiation energy. Though many research groups are recently interested in such materials, there is few experimental results except for silicon in the radiation therapy field. In this study, the feasibility of photoconductor materials was verified as a dosimeter through the evaluation of response properties at a high radiation energy. For the fabricated detectors based on $HgI_2$ and $PbI_2$, reproducibility, linearity, and pulse-rate response were analyzed. Such evaluations are essential factors for the use of dosimeter. From results, linearity and reproducibility of the fabricated $HgI_2$ detector indicated about 7% error. The fabricated $PbI_2$ detector showed 1.7% error in linearity, and 12.2% error in reproducibility.

The Environmental Control of $Er^{3+}$ ions in $R-SiO_2/ZrO_2$ Sol-Gel Matrix ($R-SiO_2/ZrO_2$ 졸-겔 재료내 $Er^{3+}$이온의 결합 환경 제어)

  • 김주현;권정오;석상일;안복엽
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.224-224
    • /
    • 2003
  • 광통신을 위한 구성 요소는 빛을 발생시키는 발광소자, 빛을 검출하는 수광소자 그리고 광신호를 처리하는 광신호처리 소자로 구성된다. 이때 각 소자간 광전송과 광소자에 의한 광 신호 처리 과정에서 광전송 손실이 심각하게 일어나 광정보를 상실하게 되므로 각 요소별로 광신호 증폭이 반드시 필요하다. 뿐만 아니라 완전 광화에 의한 초고속/대용량 광통신망의 구축에는 저가이며, 광집적화가 가능한 광도파로형 광증폭기가 요구되고 있다. 짧은 거리에 높은 증폭 효율을 얻기 위한 광도파로형 광증폭기를 구현하기 위해서는 광통신 파장대인 1.55$\mu\textrm{m}$ 대역의 증폭이 가능한 Er 이온을 고농도로 도핑 할 필요가 있다. 그러나 Er 이온을 단순히 고농도로 첨가하면 Er-Er 간 뭉침 현상에 의해 더 이상의 증폭이 어렵게 된다. 본 연구에서는 이러한 문제를 해결하면서 스핀 코팅이 가능하여 저가 공정이 가능한 유/무기 졸-겔 재료 내에 Er 이온을 제어된 방법으로 첨가하고 그 결합 환경을 FT-IR 및 $^{17}$ O-NMR로 분석하였다. 유/무기 졸겔 재료 제조를 위하여 먼저 MPTS(MethAcryoxyPropylTrimethoxySilane)를 부분 가수분해한 후 ZrOCl$_2$.8$_2$O (Zirconyl Chloride Octahydrate) 와 ErCl$_3$. 6$H_2O$ (Erbium(III) Chloride Hexahydrate)를 순차적으로 결합시키고, Zr/MPTS 및 Zr/Er의 첨가비에 따른 발광 특성을 PL(photoluminescence) 스팩트럼으로 분석하여 Er 이온의 주위 결합 환경이 PL에 미치는 영향을 조사하였다. 또한 Si 기판에 코팅한 Er이 도핑된 유/무기 하이브리드 졸-겔 코팅막의 굴절율 등 광도파로 재료로서의 특성도 프리즘 커플러 등을 이용하여 조사하였다.

  • PDF

Technology trend of optoelectronic device (광전소자의 기술동향)

  • 라용춘;조장연;박대희
    • Electrical & Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.549-556
    • /
    • 1994
  • 광전변화소자(Photo electric conversion device)는 광전효과-내부 광전효과(광도전 및 광기전력) 및 외부광전효과(광전자방출)을 이용하여 광을 전기신호로 변화시키는 소자를 광전자소자라 하며, 광전자 및 양자전자공학의 발전과 함께 많은 개발이 되고 있다. 이 광전변환소자는 주로서 고체박막의 재료를 이용하며, 소자의 소형화, 고성능화, 고신뢰성등의 요구와 함께 광전기술연구가 활발하게 진행되고 있다. 현재 광전소자의 광의 파장은 가시부만이 아니고, X선으로 부터 적외선까지에 걸쳐 있다. 이 파장에 대응하여 각종의 단결정이 필요하고, 소자의 설계가 요구된다. 이들의 응용은 소자의 광의 발진, 증폭, 검출의 소자만이 아니고 변조, 편향, 기록, 전달로등 다종다양의 기능을 갖는 소자가 요구되고 있다. 이들의 Optoelectronic Device의 연구가 활발하게 진행되어 새로운 광전소자의 제품이 개발되고 있어, 이에 대한 소개를 하고져 한다.

  • PDF

Sputtering방식을 이용한 Indium Thin oxide박막의 넓이에 따른 X-ray 검출기 특성 연구

  • Kim, Dae-Guk;Sin, Jeong-Uk;O, Gyeong-Min;Kim, Seong-Heon;Lee, Yeong-Gyu;Jo, Seong-Ho;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.321-322
    • /
    • 2012
  • 의료용 방사선 장비는 초기의 아날로그 방식의 필름 및 카세트에서 진보되어 현재는 디지털 방식의 DR (Digital Radiography)이 널리 사용되며 그에 관한 연구개발이 활발히 진행되고 있다. DR은 크게 간접방식과 직접방식의 두 분류로 나눌 수 있는데, 간접방식은 X선을 흡수하면 가시광선으로 전환하는 형광체(Scintillator)를 사용하여 X선을 가시광선으로 전환하고, 이를 Photodiode와 같은 광소자로 전기적 신호로 변환하여 방사선을 검출하는 방식을 말하며, 직접 방식은 X선을 흡수하면 전기적 신호를 발생 시키는 광도전체(Photoconductor)를 사용하여 광도전체 양단 전극에 고전압을 인가한 형태를 취하고 있는 가운데, X선이 조사되면 일차적으로 광도전체 내부에서 전자-전공쌍(Electron-hole pair)이 생성된다. 이들은 광도전체 양단의 인가되어 있는 전기장에 의해 전자는 +극으로, 전공은 -극으로 이동하여 아래에 위치한 Active matrix array을 통해 방사선을 검출하는 방식이다. 본 연구에서는 직접방식 X-ray 검출기에서 활용되는 a-Se을 ITO (Indium Thin oxide) glass 상단에 Thermal evaporation증착을 이용하여 두께 $50{\mu}m$, 33 넓이로 증착 시킨 다음, a-Se상단에 Sputtering증착을 이용하여 ITO를 11 cm, 22 cm, $2.7{\times}2.7cm$ 넓이로 증착시켜 상하부의 ITO를 Electrode로 이용하여 직접방식의 X-ray검출기 샘플을 제작하였다. 제작 과정 중 a-Se의 Thermal evaporation증착 시, 저진공 $310^{-3}_{Torr}$, 고진공 $2.210^{-5}_{Torr}$에서 보트의 가열 온도를 두 번의 스텝으로 나누어 증착 시켰다. 첫 번째 스텝 $250^{\circ}C$, 두 번째 스텝은 $260^{\circ}C$의 조건으로 증착하여 보트 내의 a-Se을 남기지 않고 전량을 소모할 수 있었으며, 스텝간의 온도차를 $10^{\circ}C$로 제어하여 균일한 박막을 형성 할 수 있었다. Sputtering증착 시, 저진공 $2.510^{-3}$, 고진공 $310^{-5}$에서 Ar, $O_2$를 사용하여 100 Sec간 플라즈마를 생성시켜 ITO를 증착하였다. 제작된 방사선 각각의 검출기 샘플 양단의 ITO에 500V의 전압을 인가하고, 진단 방사선 범위의 70 kVp, 100 mA, 0.03 sec 조건으로 X-ray를 조사시켜 ITO넓이에 따른 민감도(Sensitivity)와 암전류(Dark current)를 측정하였다. 측정결과 민감도(Sensitivity)는 X-ray샘플의 두께에 따른 $1V/{\mu}m$ 기준 시, 증착된 ITO의 넓이가 11 cm부터 22 cm, $2.7{\times}2.7cm$까지 각각 $7.610nC/cm^2$, $8.169nC/cm^2$, $6.769nC/cm^2$로 22 cm 넓이의 샘플이 가장 높은 민감도를 나타내었으나, 암전류(Dark current)는 $1.68nA/cm^2$, $3.132nA/cm^2$, $5.117nA/cm^2$로 11 cm 넓이의 샘플이 가장 낮은 값을 나타내었다. 이러한 데이터를 SNR (Signal to Noise Ratio)로 합산 하였을 시 104.359 ($1{\times}1$), 60.376($2{\times}2$), 30.621 ($2.7{\times}2.7$)로 11 cm 샘플이 신호 대 별 가장 우수한 효율을 나타냄을 알 수 있었다. 따라서 ITO박막의 면적이 클수록 민감도는 우수하나 그에 따른 암전류의 증가로 효율이 떨어짐을 검증 할 수 있었으며, 이는 ITO면적이 넓어짐에 따른 저항의 증가로 암전류에 영향을 끼침을 할 수 있었다. 본 연구를 통해 a-Se의 ITO 박막 면적에 따른 전기적 특성을 검증할 수 있었다.

  • PDF

The Evaluation and Fabrication of Photoconductor Sensor for Quality Assurance of Radiation Therapy Devices (방사선치료기기 정도관리를 위한 광도전체 센서 제작 및 평가)

  • Kang, Sang Sik;Noh, Sung Jin;Jung, Bong Jae;Noh, Ci Chul;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.565-569
    • /
    • 2016
  • Recently, a use of linear accelerator with a multi-leaf collimator(MLC) for radiation therapy is increasing. The importance of quality assurance (QA) for the linear accelerator is emphasized as the side effects of the inaccurate delivery of the radiation beam has been increased according to the high dose irradiation technique. In this study, The $HgI_2$ and $PbI_2$ photoconductor layer samples of $400{\mu}m$ thickness were fabricated using sedimentation method among particle-in-binder technology. From the fabricated samples, the electrical properties(dark current, output current, response properties and linearity) were investigated. From the experimental results, $HgI_2$ has good charge signal generation and linearity. Finally, from the signal response results about various thickness of $HgI_2$ sensor, the signal creation efficiency of $400{\mu}m$ thickness of $HgI_2$ sensor has the highest value and the excellent reproducibility below ${\pm}2.5%$.