• Title/Summary/Keyword: 고성능 AE감수제

Search Result 10, Processing Time 0.027 seconds

A Study for Improving the Fluidity Retention in Concrete Used High Range Water Reducing AE Agent (고성능AE감수제 사용 콘크리트의 유동성 유지성능 향상을 위한 연구)

  • 김기형
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.313-323
    • /
    • 1998
  • Fluidity retention of concrete used high range water reducing AE agent(HWAE) is varied according to main component, dosage amount and dosing method of HWAE. The type and substitution ratio of mineral admixture also have influence on the fluidity retention of concrete used HWAE. In this study, for the purpose of improving the fluidity retention in concrete used HWAE. 3 types of HWAE and ground granulated blast furnace slag(SG) are used in cement paste, mortar and concrete varing dosage amount and dosing time of HWAE and substitution ratio of SG respectively. According to using the HWAE of naphthalene sulfonates and SG, the fluidity retention of mortar and concrete is improved remarkably. And after 30 min, dosing method of HWAE is very effective in improving the fluidity retension and strength of concrete regardless of type of HWAE.

An Experimental Study on the Effect of Cement and High range water reducing AE agent in Fluidity of High Flowing Concrete (고유동콘크리트의 유동특성에 미치는 시멘트 및 고성능 AE감수제의 효과에 관한 연구)

  • 김규용;반성수;박선규;박유신;신홍철;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.63-68
    • /
    • 1998
  • The fluidity of high flowing concrete can be affected by numerous parameters which characterize either the cement of the admixture. The reactivity of a cement as determined by its chemical composition(especially its $C_3$A content), its fineness and its content in sulfates and alkalies obviously plays a key role in rheology of high flowing concrete in fresh state. Specific properties of high range water reducing AE agent used to enhance the workability of high flowing concrete also exert important influence. The purpose of this experimental study is to investigate and analyze the effect of cement and high range water reducing AE agent in fluidity, setting, compressive strength of high flowing concrete. As a result, we found that fluidity of high flowing concrete is affected greatly by kind of cement and high range water reducing AE agent, also, there is harmonic character between high belite cement and polycarbonic acid high range water reducing AE agent.

  • PDF

Properties of Concrete Using Slump Retentive Superplasticizer (고성능 AE감수제를 사용한 콘크리트의 기초적 성질)

  • 최재진;김은겸;신치범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.638-644
    • /
    • 1999
  • Workability time of superplasticized concrete is maintained generally for 30-60 minutes only. Therefore it is of great advantage for the concrete producer to use a high range water reducer which provides an extended slump life. Recently slump retentive srperplasticizer has been developed. Concrete mixing tests were done to know slump, setting, air content, bleeding and hardening characteristics of concrete using slump retentive superplasticizer. With slump retentive superplasticizer, high quality concrete was produced and slump loss of concrete was reduced in big way, making long transportation time possible as a practical alternative to on-site addition.

  • PDF

An Experimental Study on the Influence of the Qualities of Ordinary Portland Cement on the Flowability of High Flow Concrete (보통 포틀랜드 시멘트 품질이 고유동 콘크리트의 유동 특성에 미치는 영향에 관한 연구)

  • Choi, Sung-Woo;Jo, Hyun-Tae;Ryu, Deug-Hyun;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.37-44
    • /
    • 2012
  • Recently, due to developments in construction technology, the use of high-performance concrete became popular. High-performance concrete when compared to the ordinary concrete can better satisfy required performances by using mineral admixture and superplasticizer. Various studies on the effect of admixture materials on the quality of high-performance concrete have been reported. But there exist limited number of reported results on the effect of cement qualities, which is the most important constituent material in concrete. Therefore, in this study, the relationship between the quality of cement and the flowability of high flowing concrete is investigated. Qualities of domestically produced cement were identified, and then the influence of the qualities of cement on the flowability of high flowing concrete is evaluated. The result showed that the dosage of required superplasticizer was dependent on cement fineness, to brain, free-CaO, and interstitial phase, which all trigger initial hydration process of cement. Particularly, the results showed that fineness of cement has a high impact on the dosage of the superplasticizer. For strength property of concrete, the dosage of superplasticizer had a significant effect on the early age strength, but had negligible effect in the long term strength.

Evaluation of the Exothermic Properties and Reproducibility of Concrete Containing Electro-conductive Materials (전기전도성 재료를 혼입한 콘크리트의 발열특성 및 재현성 평가)

  • Song, Dong-Geun;Cho, Hyeong-Kyu;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.1
    • /
    • pp.25-34
    • /
    • 2016
  • From 1990's, a study on the development of exothermic concrete, a concrete which electro-conductive material is mixed, has been proceeded. However, due to the difficulty of exothermic reproducibility of concrete specimen, the study has been unable to continuously carried out. Accordingly, this study was focused on developing an exothermic concrete for the purpose of snow-melting material. Cement paste and mortar specimens mixed with graphite, conductive metal powder and chemical admixture were made. The evaluation of exothermic performance and reproducibility was conducted under $-2^{\circ}C$ of low temperature. In addition, micro-chemical analysis was carried out to investigate a cause of exothermic reproducibility. As a test result, the specimen mixed with graphite and superplasticizer with air entrained showed the best exothermic performance and reproducibility. Through micro-chemical analysis, it is judged that polymer or methacrylic acid (MAA), the contents inside the superplasticizer with air entrained, gave exothermic reproducibility by generating the electrochemical reaction with graphite.

An Experimental Study on the Required Performances of Roof Concrete Placed in the In-ground LNG Storage Tank (지하식 LNG 저장탱크의 지붕 콘크리트의 요구성능에 관한 실험적 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.339-345
    • /
    • 2013
  • This study is to derive from the required performances and the optimum mix proportion of the roof concrete placed in the in-ground LNG storage tank with a capacity of 200000 $m^3$, and propose the actual data for site concrete work. The concrete placing work without sliding and segregation in the fresh concrete condition is very important because the slope of domed roof is varied in the large range by its curvature. Also the control of hydration heat and the strength development at test ages are classified with massive section about 1.4 m thick and considered to the pre-stressing work and removal of air support after concrete placing work. Considering above condition, slump range is selected $100{\pm}25$ mm under the slope $20^{\circ}$ and $150{\pm}25$ mm over the slope $20^{\circ}$ s until 60 minutes of elapsed time. Also, the roof concrete is satisfied with compressive strength range including design strength at 91 days (30 MPa), pre-stressing work at 7 days (10 MPa), air support removal work at 21 days (14 MPa). Replacement ratio of limestone powder is determined by confined water ratio test and main design factors include water-cement ratio (W/C), sand-aggregate ratio and dosage of admixture. As test results, the optimum mix proportion of the roof concrete used low heat cement is as followings. 1) Replacement ratio of limestone powder 25% by confined water ratio test 2) Water-cement ratio 57.8% 3) Sand-aggregate ratio 42.0%. Also, test results for the adiabatic temperature rising test is satisfied with its criteria and shown the lower value compared to preceding storage tank (TK-13, 14). These required performances and the optimum mix proportion is to apply the actual construction work.