• Title/Summary/Keyword: 고분해능 질량분석기

Search Result 18, Processing Time 0.023 seconds

Pulsed-Delayed Extraction for Resolution Enhancement of Linear Time-of-Flight Mass Spectromenter in Surface-Assisted Laser Desorption/Ionization of Polypropyleneglycol (폴리프로필렌 글리콜의 표면-보조 레이저 탈착/이온화에서 선형 비행시간 질량분석기의 분해능 개선을 위한 시간 지연 추출법의 응용)

  • Kim, Jung Hwan;Kang, Wee Kyung
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.4
    • /
    • pp.328-336
    • /
    • 2000
  • The pulsed-delayed extraction (PDE) in linear time-of-flight mass spectrometer(TOF MS) is characterized on the enhancement of resolution, mass-depth of focus and effect of instrumentahan 2000. The ion signals separate isotopically by up to molecular weight of 2500 in instrumental broadening of 5 ns, which is a good agreement with calculation. The fragmentation paths of PPG can be sug-gested by the isotopica distributions of fragment series produced when PPG desorbed from graphite surface.

  • PDF

Analysis of PCDD/Fs and PCBs in Human Blood and Characteristics of Contamination Sources (국내 혈액에서의 PCDD/Fs 및 PCBs 분석과 오염원 특성에 관한 연구)

  • Yang, Yoon Hee;Kim, Byung Hoon;Chang, Yoon Seok
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.147-158
    • /
    • 2001
  • Polychlorinated dibenzo-p-dioxins(PCDDs), dibenzofurans(PCDFs), and biphenyls(PCBs) were analyzed by HRGC/HRMS in human blood samples from the Siwha industrial area in Korea. The PCDD/F and PCB concentrations in workers were higher than those in residents. The average TEQ concentrations of PCDD/Fs in workers and residents were 40.3 pg I-TEQs/g lipid and 16.6 pg I-TEQs/g lipid, respectively, and the total PCB concentrations were 174.1 ng/g lipid and 151.0 ng/g lipid, respectively. When applied to principal component analysis, the PCDD/F congener distributions of workers were differentiated from those of residents. But, all of them were similar to the distribution in several Korean foods. Estimated daily intake(EDI) of each person was calculated, and then only 40% to the total people were within the tolerable daily intake range(1-4pg I-TEQ/kg bw/day) suggested by WHO(1997).

  • PDF

Analysis of Dioxins and Furans from Bottom Ash Produced in an Municipal Solid Waste Incinerator (도시 소각로 시설의 고형 쓰레기 연소 후 생성된 바닥재 시료에 대한 다이옥신과 퓨란류의 분석)

  • Chang, Yoon-Seok;Hong, JongKi;Kim, Jin-Young
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.7
    • /
    • pp.513-523
    • /
    • 1995
  • Polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) are the most concerned toxic organic pollutants to human. Because of their extremely high toxicity and uncertain genotoxic potential, their determination in environmental and biological samples is of great interest. Municipal solid waste incinerator facilities have been reported as the major contributors of dioxins and furans to the environment, and their formation from combustion is a universal phenomenon, everywhere. In this study dioxins and furans were analyzed from the bottom ash produced during combustion in an municipal waste incinerator located in Seoul. The EPA method was modified for sample pretreatment: the soxhlet method was used for extraction and clean-up procedures were performed by using silica and basic alumina, excluding active-carbon. The extract was then analyzed by HRGC/HRMS. A general trend of increase in the amounts of 6∼7 chlorine-substituted dioxins and furans was observed. Total dioxins, furans and 2,3,7,8-TCDD were determined as 8.05 ng/g, 4.75 ng/g, and 6.93 pg/g, respectively.

  • PDF

Congener Specific Characteristics of PCBs and PCDD/Fs and Risk Assesment for Human Milk of Korea (국내 모유에서의 PCBs 및 PCDD/Fs 분포 특성과 위해성 평가)

  • Yang, Yoon-Hee;Chang, Yoon-Seok;Kim, Byung-Hoon;Yang, Ji-Yoen;Shin, Dong-Chun
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.520-533
    • /
    • 2000
  • We analyzed the PCDD/Fs and PCBs in human milk samples from a city and an industrial region by HRGC/HRMS. The average concentrations of PCDD/Fs and PCBs in human milk were 15.13 TEQ pg/g fat and 5.64 TEQ pg/g fat respectively. We discovered two kinds of homologue distributions. We compared congeners of each distributions with those of the commercial PCBs products. The daily intake of infant was predicted to be 60 TEQpg/kg/day according to the mean concentration of PCDD/Fs based on primipara. This value is much higher than the estimated range for background exposure to adult in the USA (1-3 TEQ pg/g fat).

  • PDF

Determination of PCDD/F in Working Clothes of a Municipal Waste Incineration (생활폐기물 소각장 작업복 샘플의 다이옥신 분석)

  • 박순자;신정화;신정숙;정명희;안윤경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.2
    • /
    • pp.354-363
    • /
    • 2004
  • PCDD/F (Polychlorinated dibenzo-p-dioxins and dibenzofurans) in both of treated fabric and untreated fabric for working clothes of a municipal waste incineration were determinated. The treated fabric for working clothes was developed for less exposure of PCDD/F in municipal waste incinerations. The total concentrations of PCDD/F in some parts such as surface, middle layer, inside for treated and untreated fabric were investigated. The I-TEQ value of surface was 0.23370ng TEQ/g for treated fabric, 0.15355ng $.$ TEQ/g for non-treated fabric. On the other hand, the value of middle layer was 0.00077ng $.$ TEQ/g, 0.00177ng $.$ TEQ/g, respectively. The surface of the treated fabric containing high levels PCDD/F was caused by absorption of them. Therefore, PCDD/F of the treated fabric in middle layer was less I-TEQ value than that of the untreated fabric. The treated fabric makes effect on preventing PCDD/F from permeating into human body.

Structural determination of triterpenic acids in Prunellae Spica by fast atom bombardment tandem mass spectrometry (하고초의 생리활성 성분 Triterpenic Acids의 FAB-MS를 이용한 구조 규명)

  • Ahn, Young Min;Lee, Kang Ro;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.245-258
    • /
    • 2008
  • Five triterpenic acids as marker compounds were extracted and isolated from Prunellae Spica by column chromatography and reversed-phase high-performance liquid chromatography (HPLC), and their purity was determinated by HPLC (purity ${\geq}90%$). Molecular weight and elemental compositions of the five marker compounds were determined by fast atom bombardment high-resolution mass spectrometry (FAB-HRMS). The structural determination of the five marker compounds was carried out fast atom bombardment collision-induced dissociation tandem mass spectrometry (FAB-CID-MS/MS). The collision-induced dissociation (CID) of protonated molecules $[M+H]^+$ and deprotonated molecules $[M-H]^-$ produced diverse product ions due mainly to retro Diels-Alder reaction (RDA), dehydration and decarboxylation. Moreover, the CID-MS/MS spectra of the $[M-H]^-$ ions were observed charge-remote fragmentation (CRF) patterns. On the basis of interpretation of CID-MS/MS spectra, structural elucidation of triterpenic acids isolated from Prunellae Spica was clearly performed.

Analysis of all PCB Congeners in Air Samples by HRGC/HRMS (대기 시료 중 PCBs 전 이성체 분석에 관한 연구)

  • Kim, Kyoung-Soo;Song, Byung-Joo;Kim, Jong-Guk
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.309-319
    • /
    • 2003
  • This study was performed to describe analysis method of 209 PCB congeners in ambient air samples. The samples were collected by high volume air sampler in Chonju city. Extracted samples were cleaned by silicagel cleanup modified with sulfuric acid and activated carbon cleanup processing. The cleaned samples were analyzed by high resolution gas chromatography and high resolution mass spectrometry (HRGC/HRMS) with DB-5 column (60 m, 0.25 mm i.d., 0.25 m film thickness) to analyze the 209 kinds of PCB congeners. PCBs levels of air samples were detected to the range between 0.003 and $0.163pg-TEQ/m^3$. The PCBs congener of 162 kinds were detected in samples analysed using DB-5 column and 37 kinds peaks were overlapped with congeners more than one. It is difficult to isolate PCB 118/106 and PCB 105/127 in coplanar PCB, so it is likely to overestimate the concentration.. The distribution of coplanar-PCB congeners in origin source samples (Kanechlor and exhaust gas from incinerator) was compared with that in air samples, and PCB 81, PCB 77, PCB 126, and PCB 169 were higher in incinerator samples.

Evaluation of human exposure to polychlorinated biphenyls using human serum by congener-specific analysis (혈액 중 PCBs 이성질체별 분석에 의한 인체 노출 평가)

  • Park, Hyo-Keun;Lee, Se-Jin;Jin, Guang-Zhu;Kang, Jung-Ho;Baek, Song-E;Chang, Yoon-Seok
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.73-85
    • /
    • 2006
  • Blood serum concentrations of polychlorinated biphenyls (PCBs) were measured in employees who worked at a municipal solid waste incinerator (MSWI), members of residential community who lived near the MSWI (<0.3km) and members of residential community lived far from the MSWI (>10 km). Human blood serum samples were analyzed for all PCB congeners using high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS). The mean levels of total PCBs and dioxin-like PCBs in 87 serum samples were 242.77 ng/g lipid and 8.83 TEQ pg/g lipid, respectively. The PCB homologue profiles showed that penta-, hexa-, hepta-chlorinated biphenyls contributed more than 80% of the total PCBs concentration. The most abundant congeners were PCB153, PCB138, PCB180, PCB187, PCB118. A statistical analysis was performed to determine whether there were significant correlations between PCB concentrations and specific variables such as age, gender, smoking habits, occupation, BMI (Body Mass Index) and time of residence. As a result, the age was found to be strongly correlated with serum PCB concentrations. In addition, there were strong correlations between total PCBs and PCB153 (r=0.93, p<.0001), dioxin-like PCBs and PCB118 (r=0.98, p<.0001). So these two congeners are satisfactory indicators for total PCB concentrations and dioxin-like PCBs in human blood respectively.