• Title/Summary/Keyword: 고무 두께

Search Result 240, Processing Time 0.025 seconds

Properties of Polymer Electrolytes based on PEO-LiClO$_4$ Matrix Fabricated by Sol-Gel Process (솔-젤 법으로 만든 PEO-LiClO$_4$에 기초한 고분자 전해질의 물성)

  • 박영욱;이동성
    • Polymer(Korea)
    • /
    • v.27 no.3
    • /
    • pp.265-270
    • /
    • 2003
  • In spite of high ionic conductivity, the polymer gels have poor mechanical properties and high reactivity with lithium metal anode. To solve these problems, the dry solid systems and polymer composites have been intensively studied, due to their good mechanical, thermal, chemical, and electrochemical stability. The objectives of this experiment were to improve ionic conductivity and mechanical properties of the solid polymer electrolytes based on PEO-LiClO$_4$. To obtain higher ionic conductivity and better mechanical properties, ceramic or rubber phase was added in the PEO-LiClO$_4$(8:1) matrix. The results showed that ionic conductivity and mechanical properties were improved. The ionic conductivity of the samples was as high as 10$\^$-5/ S cm$\^$-1/. This value is similar to the best ionic conductivity ever reported in the solid drying system. To obtain better results, we used PEO with various molecular weights (600∼8000) and changed the salt contents. By using DSC, we found that the addition of salt reduced the crystallinity of PEO. The mobility of polymer dependence on salt contents was examined by FT-IR.

Milling Characteristics and Milled Rice Quality of Rice Varieties with Different Grain Size Shape (입형이 다른 벼 품종의 도정특성 및 쌀품위)

  • Hong, Ha-Cheol;Jeong, Young-Pyeong;Kim, Tae-Young;Son, Jong-Rok;Hwang, Hung-Goo;Choi, Hae-Chune;Min, Young-Kyoo;Kim, Kee-Jong
    • Applied Biological Chemistry
    • /
    • v.46 no.1
    • /
    • pp.46-49
    • /
    • 2003
  • Paddy and milled rice quality, milling characteristics, energy consumption of milling process were investigated using Dasanbyeo, Ansanbyeo, Hwaseongbyeo, Ilpumbyeo, and Donganbyeo varieties. Thousand grains weights of the varieties dried to 15% moisture content were 22.92-28.60 g, with Dasanbyeo being the heaviest. Optimum clearance of rubber roller for obtaining maximum dehulling recovery was 30% of each rice variety thickness. At that time, perfect brown rice ratios of Dasanbyeo, Ansanbyeo, Hwaseongbyeo, Ilpumbyeo, and Donganbyeo were 95.24%, 98.86%, 95.97%, 97.75%, and 97.31%, respectively, and showed no significant differences among varieties. Ratios of removed rice bran after two times milling ranged 70.93-91.38%, with Dasanbyeo showing the highest ratio, and the average head rice ratio was 92.87%.

Analysis on the Physical Property of Para-Aramid Filament according to the ATY processing Cordition (ATY 공정조건에 따른 Para Aramid 필라멘트의 물성분석)

  • Kim, Seung-Jin;Park, Mi-Ra;Ma, Hye-Young;Choi, La-Hee;Park, Sung-Woo;Kang, Yoon-Hwa
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.03a
    • /
    • pp.29-29
    • /
    • 2011
  • 아라미드 섬유는 열에 강한 튼튼한 방향족 폴리아마이드 섬유이다. 아마이드는 "85%이상의 아미드(CO-NH)기가 두 개의 방향족 고리에 직접 연결된 합성 폴리아미드로부터 제조된 섬유"로 정의된다. 아라미드 섬유는 크게 파라계와 메타계로 대별되는데 본 연구에서 사용한 파라계 아라미드는 인장강도, 강인성, 내열성이 뛰어나며 고강력 고탄성률을 지니고 있다. 일반적인 유기 섬유와는 다른 우수한 성질을 바탕으로 부직포, UD laminatig, staple 등의 형태로 크게 섬유보강 고무 복합재료 등의 각종 복합재료, 로프, 케이블, 방탄방호용과 같은 산업자재의 용도로 자동차, 우주항공, 정보통신, 국방, 등 다양한 관련 산업분야에서 사용이 확대되고 있는 고부가 소재이며 가격대비 성능비가 우수하기 때문에 세계적으로 산업용 섬유 및 초고성능 섬유시장에서 비중이 증가될 것으로 예상되고 있다. 본 연구에서는 Para-Aramid 필라멘트를 이용하여 ATY를 생산할 때 제조공정조건에 따른 ATY 물성을 알아보고 고강도를 요구하는 방화복, 고무 보강용 섬유 등의 소재에 맞는 ATY 사가공 최적공정조건을 도출하여 체계화된 data-base를 구축하여 생산성 향상 및 품질개선과 함께 산업자재용 직물개발에 응용하고자 한다. 아라미드를 ATY로 제조할 경우, 표면에 생기는 loop로 인하여 타소재와 접착시, 접착제 담지 성능이 향상되어 접착력이 상승되는 반면, 아라미드 ATY가 기존의 아라미드의 물성보다 저하되는 약점을 가지고 있으므로 이를 보완하기 위해 본 연구에서는 ATY 제조공정에서 중요 공정인자인 사속, heater 온도, over feed ratio를 변화시켜 시료를 제조하여 이들의 물성을 분석하여 최적의 물성을 갖는 ATY 사가공 공정을 도출함으로써 물성이 저하되는 문제를 보완 가능할 것으로 기대된다. 물성분석은 강신도, 초기탄성률을 각각 측정하여 인장특성을 확인하였으며, 습열수축률과 건열수축률을 측정하여 시료의 열수축률에 대해 측정을 하였다. 표면의 루프 발현 정도를 보기 위하여 Crimp Rigidity(CR%), 형태 불안정성(instability)등을 측정하였으며, 영상 현미경 시스템을 사용하여 ${\times}40$ 배율로 표면특성을 측정하였다.

  • PDF

Effect of Rootzone Mixes Amended with Crumb Rubber on the Physical Properties (폐 타이어 고무칩을 혼합한 개량제의 물리성 개선 효과)

  • Chong, She-Kong;Ok, Chang-Ho
    • Asian Journal of Turfgrass Science
    • /
    • v.20 no.1
    • /
    • pp.83-91
    • /
    • 2006
  • This research was initiated to enhance the tilth of fine-textured soil for turf growth by incorporation of crumb rubber shredded from used tires. A specific objective was to determine the physical properties of soil mixes amended with different grade and amount of crumb rubber in soils. Two soils and three different grades(3.5, 6.5 and 9.5 mm) of crumb rubber were used. The soils selected were an Arenzville silt loam(coarse-silty, mixed, nonacid, mesic Typic Udifluvents) and a Hosmer silty clay loam(fine-silty, mixed, mesic Typic Fragiudalfs). The amount of crumb rubber mixed in soil ranged from 0 to 0.4 $g{\cdot}g^{-1}$(using 0.05 $g{\cdot}g^{-1}$) increments and 0 as a control. For each treatment, soil cores were constructed following the recommendation by the United States Golf Association Green Section Record. Results indicated that porosity of the mixes decreased as the amount of crumb rubber increased. Regardless of the grade of crumb rubber, mixes with less than 0.15 $g{\cdot}g^{-1}$ of crumb rubber in fine-textured soil could not enhance their macro-porosity and hydraulic conductivity. However, as the amendment increased over 0.15 $g{\cdot}g^{-1}$, the tilth of the mixes had improved significantly macro-porosity, hydraulic conductivity and air permeability, as compared with a control.

Microwave Absorbing Properties of M-type Barium Ferrites with BaTi0.5Co0.5Fe11O19 Composition in Ka-band Frequencies (BaTi0.5Co0.5Fe11O19 조성을 갖는 M형 바륨 페라이트의 Ka-밴드 전파흡수특성)

  • Kim, Yong-Jin;Kim, Sung-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.6
    • /
    • pp.203-208
    • /
    • 2009
  • Magnetic and Ka-band absorbing properties have been investigated in Ti-Co substituted M-type barium hexaferrites with $BaTi_{0.5}Co_{0.5}Fe_{11}O_{19}$ composition. The ferrite powders were prepared by conventional ceramic processing technique and used as absorbent fillers in ferrite-rubber composites. The magnetic properties were measured by vibrating sample magnetometer. The complex permeability and dielectric constant were measured by using the WR-28 rectangular waveguide and network analyzer in the frequency range 26.5~40 GHz. For the Ti-Co substituted M-hexaferrites, the ferromagnetic resonance is observed at Ka-band (29.4 GHz). The matching frequency and matching thickness are determined by using the solution map of impedance matching. A wide band microwave absorbance is predicted with controlled ferrite volume fraction and absorber thickness.

A Basic Study on a Magnetic Fluid Driven Artificial Heart (자성유체에 의해 구동되는 인공심장에 관한 기초연구)

  • Kim, Dong-Wook;MITAMURA, Yoshinoro
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.5
    • /
    • pp.940-947
    • /
    • 2006
  • A variety of actuators fur an implantable artificial heart have been studied. They, all, however, share the disadvantages of a complicated energy conversion mechanism and of the need to use bearings. A ferrofluidic actuator directly drives magnetic fluids by applying a magnetic field to these fluids; it does not require bearings. In this study, the feasibility of a ferrofluidic actuator for an implantable artificial heart was studied. An way of two Poles of ring solenoids was mounted near the acrylic tube $({\phi}\;7.4mm)$. A rubber sack (volume : $2m{\ell}$ was connected to both ends of the acrylic tube. The sack were encased in a rigid chamber that had inlet and outlet ports. The acrylic tube and the rubber sack were filled with water encased in a rigid chamber magnetic fluid and the iron cylinder were immersed in the water. Two experiment method was conducted. 1) distance between stoppers were 72mm and 2) distance between stoppers were 104mm. A stroke volume was stability and $0.96m{\ell}$ was obtained in the experiment 1 and $1.92m{\ell}$ in the experiment 2. The energy efficiency of Experiment method 2 is about five times than Experiment method 2. A magnetic fluid-driven blood pump could be feasible if the magnetic fluid with high magnetization (3 times yester than the current value) is developed.

  • PDF

A study on visuomotor and visuotactile synchronization in full body ownership illusion with virtual avatars (가상 아바타와의 전신 몸 소유감에서 시각-운동 및 시각-촉각 동기화에 관한 연구)

  • Oh, Jintaek;Kim, Jihwan;Kim, Kwanguk
    • Journal of the Korea Computer Graphics Society
    • /
    • v.28 no.3
    • /
    • pp.1-11
    • /
    • 2022
  • Body ownership illusion (BOI), which means 'the illusion that a non-bodily object feels like my body', has been actively studied since the Rubber-hand Illusion showed that a person can feel a rubber hand like one's own hand. It has been proven that BOI can be elicited for virtual bodies in virtual reality. Although many studies have been examined the effect of visuomotor (VM) and visuotactile (VT) stimuli, which are mainly used for the elicitation of BOI, there were very limited studies that delivered both stimuli to the whole body at the same time. In this paper, we investigated how each stimulus affects BOI when delivering VM and VT stimulisimultaneously to the virtual avatar, and examined user experience that appears as presence, emotion, and virtual motion sickness. The results showed that BOI was high when VM is synchronous, but there was no significant difference according to VT levels. In the case of presence, it was confirmed that VT affects only when VM is synchronous, and in the case of emotion, both VM and VT affect valence, and in the case of virtual motion sickness, a statistical difference is not found.These results suggest that overall synchrony of VM is important factor in BOI with virtual avatars, but that the matching VT affects subjective experience such as presence when VM is synchronous.

Full-scale Shaking Table Test of Uninterruptible Power Supply Installed in 2-stories Steel Structure (2층 철골 구조물에 설치된 무정전전원장치의 실규모 진동대 실험연구)

  • Lee, Ji-Eon;Park, Won-Il;Choi, Kyoung-Kyu;Oh, Sang-Hoon;Park, Hoon-Yang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.29-38
    • /
    • 2022
  • In this study, the shaking table tests were carried out on six types of non-structural elements installed on a full-scale two-story steel structure. The shaking table tests were performed for non-structural elements with and without seismic isolators. In this study, the seismic performance of Uninterruptible Power Supply (UPS) specimens was tested and investigated. Non-seismic details were composed of conventional channel section steel beams, and the seismic isolators were composed of high damping rubber bearing (HDRB) and wire isolator. The input acceleration time histories were artificially generated to satisfy the requirements proposed by the ICC-ES AC156 code. Based on the test results, the damage and dynamic characteristics of the UPS with the seismic isolator were investigated in terms of the natural frequency, damping ratio, acceleration time history responses, dynamic amplification factors, and relative displacements. The results from the shaking table showed that the dynamic characteristics of the UPS including the acceleration response were significantly improved when using the seismic isolator.

The Consideration of the Region of Interest on $^{99m}Tc$-DMSA Renal Scan in Pediatric Hydronephrosis Patients (수신증을 진단 받은 소아 환자의 DMSA 신장 검사에서 정확한 관심영역 설정에 대한 고찰)

  • NamKoong, Hyuk;Lee, Dong-Hyuk;Oh, Shin-Hyun;Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2012
  • Purpose: Most of diagnosis in the pediatric hydronephrosis patients have been performed $^{99m}Tc$-DMSA renal scan. Then the region of interest (ROI) is set for comparative analysis of uptake ratio in left-right kidney after acquiring the image. But if the equipment set an automatic ROI, the ROI could include expanded renal pelvis due to hydronephrosis and the uptake ratio of left-right kidney will be incorrect result. Therefore this study compared both ROIs including expanded renal pelvis and excluding renal pelvis through experiment using normal kidney phantom and expanded renal pelvis phantom and suggested setting method of improved ROI. In addition, this study have been helped by readout doctor for investigate distinction radiopharmaceutical uptake between renal cortex and remained urine by expanded renal pelvis. Materials and Methods: The both of renal phantoms were filled with water and shacked with $^{99m}TcO_4$ 111 MBq. In order to describe the expanded renal pelvis, the five latex balloon were all filled with 10 mL water and each of balloon was mixed with $^{99m}TcO_4$ 18.5, 37, 55.5, 74, 92.5 MBq. And we made phantom with fixed $^{99m}TcO_4$activity of 37 MBq and mixed water 5, 10, 15, 20, 25 mL in each balloon. The left kidney was fixed its shape and the right kidney was modified like as hydronephrosis kidney by attached the latex balloons. And the acquiring counts were 2 million. After acquisition, we compared the image of ROI with Expanded renal pelvis and the image of ROI without renal pelvis for analyzing difference in the uptake ratio of left-right kidney and for reproducibility, set the ROI 5 times in the same images. Patients were injected $^{99m}Tc$-DMSA 1.5~1.9 MBq/kg and scanned 3 to 4 hours after injection. The each of 3 skillful radio technologists performed the comparing estimation by setting ROI. To determine statistical significance between two data, SPSS (ver. 17) Wilcoxon Signed Ranks Test was used. Results: As a result of renal phantom's experiment, we compared with average of counts Background (BKG) ratios in the setting of ROI including expanded renal pelvis and setting of excluding expanded renal pelvis. Therefore, they can obtain changed counts and changed ratios. Patient also can obtain same results. In addition, the radiopharmaceutical uptake in expanded renal pelvis was come out the remained urine that couldn't descend to ureter by the help of readout doctor. Conclusion: As above results, the case of setting ROI including expanded renal pelvis was more abnormally increasing uptake ratio than the case of setting ROI excluding expanded renal pelvis in analysis the uptake ratio in left-right kidney of hydronephrosis. Because of the work convenience and prompted analysis, the automatic ROI is generally used. But in case of the hydronephrosis study, we should set the manual ROI without expanded renal pelvis for an accurate observation of the uptake ratio of left-right kidney since the radiopharmaceutical uptake in expanded renal pelvis is the remained urine.

  • PDF

Performance of Thrie-Beam Guardrail System withe Impact Attenuator (에너지 흡수 장치를 부착한 트라이빔 가드레일 시스템의 거동)

  • Ko, Man-Gi;Kim, Kee-Dong
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.4
    • /
    • pp.381-393
    • /
    • 2001
  • The current traffic situation in Korea can be described as rapid change in traffic volume and diversity in vehicle size from compact cars to large trucks. W-beam barrier most widely used in Korea was found not to satisfy the stiffness requirement for the Koran impact condition of 14 ton-60Km/h-15deg. and it was too stiff for small vehicles impacting with more realistic speed to satisfy the safety of vehicle occupants. To develop a guardrail system satisfying the two contradicting goals, a thrie-beam guardrail system, which had the beam thickness of 3.2mm and rubber cushions, was conceived. Even though the height of the thrie-beam(450mm) is increased by 100mm as compared to that of W-beam (350mm), there was only 2% increase in the weight of the thrie-beam. The new thrie-beam barrier system could contain more wide range of vehicle bumper heights, and showed better performance in the viewpoint of stiffness and energy absorbing capability than the W-beam system. The impact performance was evaluated from a crash test. The developed thrie-beam guardrail system satisfied all applicable criteria for NCHRP 350 test designation 3-10.

  • PDF