• Title/Summary/Keyword: 고무제거

Search Result 53, Processing Time 0.029 seconds

Mechanically Induced Long Period Fiber Grating Array Device and Sensor Application (기계적으로 유도되는 장주기 광섬유 격자 배열 소자 및 센서 응용)

  • Lee, Nam-Kwon;Song, Jae-Won;Park, Jea-Hee
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.142-148
    • /
    • 2007
  • A mechanically induced long-period fiber grating array was fabricated and its transmission characteristics were measured. The grating away consisted of a rubber cover and a 45 cm metal bar with 10 grating groups. Each grating group was composed of 60 gratings. The period of the grating of the grating groups was increased by $10{\mu}m$ increments from $690{\mu}m$ to $780{\mu}m$. The long period fiber grating was induced when the pressure was applied on the long period grating array and the resonant wavelength depended on the position of applied pressure. The experimental results shows that this long period fiber grating away can be used as a various band rejection filter or a fiber optic sensor.

A Case of Mucocele in the Left Frontal Sinus (전두동 점액낭종)

  • 박병옥;노영식;소장영;김영길;김선우
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.13.2-13
    • /
    • 1981
  • Authors was experienced a case of mucocele in the left frontal sinus. A 24-years-old Korean male soldier was admitted to C.A.F.G.H. on 16th May 1980, with chief complaints of dull headache, exophthalmos, visual disturbance and intermittent epistaxis on the left side. On physical examination, left turbinates and septum were revealed hyperemic middle turbinate with blood tinged spots and deviated slightly to right side, and felt round, smooth, rubbery painless swelling within the orbit at the left inner canthus. The left orbital contents was displaced laterally producing proptosis with diplopia. On the radiological examination, Caldwell and Water's view showed hazy density in medial side of left orbital and left frontal sinus. Tomography of orbit showed hazy increased mass density with rather sharply defined outer margin of left bony orbit probably due to compressive erosion. The case was treated with surgical removal of the Lynch frontal approach, so present this case with a brief review of the literature.

  • PDF

Survey on the Cultivation Process of Plant Tissue Culture (식물조직 배양공정의 기계화를 위한 작업실태분석)

  • 강창호;정석현;한길수;권기영;윤진하;최홍기
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.401-406
    • /
    • 2002
  • 식물조직 배양공정의 기계화 기술개발을 위한 기초자료를 얻고자 식물조직 배양기술의 개발 또는 식물묘를 대량생산하는 연구지도기관 및 농원 등의 배양실 10개소를 대상으로 배지의 분주, 배양용기의 밀봉 및 세척, 배양체의 접종공정 등에 대한 작업실태를 조사분석한 결과를 요약하면 다음과 같다. 가. 배양기술의 개발 또는 식물묘 대량생산은 대부분이 나리, 호접란, 풍란, 심비디움 등 화훼류였으며, 배지는 모두 한천이 혼합된 고체배지, 배양용기는 형상 및 용량 등이 다른 플라스크, 배양병, pE용기 등이 사용되었다. 나. 배지의 분주작업은 조사대상 10개배양실중 6개소는 작업자가 비이커를 사용하여 분주하였고 4개소는 자동 또는 반자동분주기를 사용하였으며, 인력 및 반자동분주기의 사용시 배양용기간의 분주량은 기준량의 $\pm$25%범위에서 차이가 있었다. 다. 액체배지의 분주시 온도는 36.8~88.$0^{\circ}C$, 점도는 3.7~11.8cP 범위였고 점도는 배지에 혼합하는 한천, 사과 등 유기물의 량에 따라 차이가 있으므로 배지의 분주작업을 기계화하기 위해서는 배지의 온도와 점도, 배양용기와 분주량 등을 종합적으로 고려하여 배지의 점도에 따라 분주량을 조절할 수 있도록 개발할 필요성이 있다고 생각된다. 라. 배양용기의 밀봉소재는 플라스크의 경우 호일 또는 고무마개와 호일, 배양병은 모두 나사산이 있는 캡, PE용기는 뚜껑을 사용하였으며, 밀봉작업은 모든 배양실에서 인력에 의존하였고 작업능률은 호일만으로 밀봉하는 경우 시간당 180~240병, 캡은 시간당470~600개 정도였다. 마. 배양체의 접종작업은 모든 배양실이 인력에 의존하였으며, 배양체를 배지와 분리하여 불필요한 부분을 제거하고 배양작물에 따라 생육정도를 2~3등급으로 구분하여 배양용기의 배지 위에 치상하는 과정으로 수행되었으며, 작업능률은 호접란의 경우 배양병에 25본을 접종하는데 시간당 6병, 심비디움은 원형 플라스크에 25본을 접종하는데 시간당 10병 정도였다. 바. 식물체의 대량증식에 사용되는 플라스크, 배양병, PE용기 등 배양용기의 세척작업은 농원의 1개배양실에서 간이식 세척기, 이 외의 9개배양실은 모두 물에 담겨 두었다가 세제와 브러쉬 등을 사용하여 인력으로 세척하고 있어 생력화 기술개발이 요구되었다.

  • PDF

Effect of Concentration Polarization on The Pervaporation of Aqueous Chlorinated-Organic Solution (유기염화물 수용액의 투과증발에 미치는 농도분극의 영향)

  • Cho, Min-Suk;Kim, Seung-Jai;Kim, Jin-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.9 no.5
    • /
    • pp.698-703
    • /
    • 1998
  • The pervaporation experiments of aqueous solutions of trichloroethylene (TCE) and chlorobenzene (CB) through the silicone rubber (polydimethylsiloxane, PDMS) membrane were carried out and the effect of concentration polarization on the separation characteristics was investigated. The resistance-in-series model was used to explain the boundary layer resistance. It was clear that the concentration polarization phenomenon had a significant effect on the permeation behavior in the pervaporation separation of the trace organic chlorides from aqueous solutions. With the same membrane thickness, the permeation of TCE, which has a stronger affinity for the PDMS, appeared to be more influenced by the boundary layer resistance than that of CB. The effect of boundary layer resistance was reduced and the membrane resistance became dominant with increasing membrane thickness at a given hydrodynamic condition. The separation factor was increased to approach the intrinsic separation factor of the membrane with its thickness.

  • PDF

Scientific Conservation of Underwood Typewriter(Hangi6863) in National Hangeul Museum (국립한글박물관 소장 언더우드 영문 타자기(한기6863)의 과학적 보존)

  • Kim, Yu Jin;Chung, Kwang Yong
    • Conservation Science in Museum
    • /
    • v.28
    • /
    • pp.1-16
    • /
    • 2022
  • Treatment was performed to conserve the Underwood Typewriter (Hangi 6863) from the collection of the National Hangeul Museum. Since the typewriter was presumably manufactured in the modern or contemporary era and bore patterns of damage such as component loss, corrosion, and paint loss, as well as being made of multiple materials, a condition survey and a scientific analysis were conducted ahead of the conservation treatment in order to carry out appropriate treatments for each material. The analysis confirmed that the typewriter was made of various materials including metal, paint, and rubber, and the conservation treatment was performed in the sequence of removal of contamination, reinforcement, and restoration under conditions where each material was stable. Conservation treatment was completed in a stable state by strengthening the layer of damaged paint and restoring the lost leg. These processes have enabled a better understanding of the materials and characteristics of typewriters manufactured in the early modern era, which is expected to provide basic data for typewriter conservation research to be conducted in the future.

TREATMENT OF OPEN BITE BY TONGUE THRUSTING HABIT USING HABIT BREAKING APPLIANCE AND MYOFUNCTIONAL THERAPY (습관제거장치와 근기능요법을 이용한 혀내밀기 원인성 개방교합의 치료)

  • Choi, Ji-Won;Oh, You-Hyang;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.229-235
    • /
    • 2005
  • A problem that affects children's dentitions is the harmful habit which is difficult to treat. Harmful habits for children are such as abnormal swallowing patterns, low/forward tongue rest posture problem, habitual open-lips resting posture, habitual mouth-breathing, excessive digital sucking habit and tongue thrusting. Tongue thrusting habits cause a bit of cranio-facial skeletal changes and a great deal of dental malocclusion such as anterior open bite. Anterior open bite causes masticatory, speech, and esthetic problems in the growing children and difficulties in diagnosis, treatment, and the prediction of its prognosis. The treatments of such abnormal behaviors involve orofacial myofunctional therapy and using of habit breaking appliance. The prognosis is not determined by the presence of severity of oral habit but the skeletal tendency of the patient. Usage of tongue crib resulted in not only the discontinuance of the habit but also improvement in overbite and overbite. This study showed that relatively successful results could be generated by using removable tongue crib and myofunctional therapy in the case of openbite related to tongue thrusting habit.

  • PDF

The Effects of Diluted Fibrin Glue about Continuous Air Leakage after Lung Surgery (폐수술 후 지속적 공기누출에 희석한 Fibrin Glue의 효과)

  • Choi Chang-Woo;Lee Seong-Jin;Lee Chol-Sae;Lee Kihl-Rho;Lee Seock-Yeol
    • Journal of Chest Surgery
    • /
    • v.39 no.10 s.267
    • /
    • pp.770-774
    • /
    • 2006
  • Background: Continuous air leakage through chest tube after lung surgery may increase pt's hospital stay and lead to many complications including empyema etc. Chemical pleurodesis has frequently been used for prevention of air leakage. Therefore, we performed chemical pleurodesis using diluted fibrin glue in patients with continuous air leak-age and observed the effects and efficiency of treatment. Material and Method: From September, 2001 to August, 2005, 16 patients whose continuous air leakage lasted more than 7 days underwent chemical pleurodesis with diluted fibrin glue. The effects of treatment, complications and recurrences were reviewed. Dissolved fibrinogen 1.0 g and aprotinin 500,000 KIU were mixed in a 50 cc syringe (Mixed solution A). And dissolved thrombin 5,000 IU and Calcium chloride 600 mg were mixed in a 50 cc syringe (Mixed solution B). Cefazolin 1.0 g was mixed in a 50 cc syringe (Mixed solution C). Rubber tube was inserted between the chest tube and the collecting bottle. An inserted rubber tube was positioned 60cm above the patient and forming a loop appearance was done. Mixed solutions A, B and C were injected into the highest rubber tube. Results: Continuous air leakages disappeared in all f6 patients at next day. Chest tubes were removed after 3 days in all patients. Complications were chest pain in 12 patients (75%), leukocytosis in 14 patients (88%), fever and chill in 14 patients (88%). All complications were transient and disappeared without specific treatment. Conclusion: Our findings demonstrated that diluted fibrin glue chemical pleurodesis was effective in patients with continuous air leakage lasting more than 7 days. Diluted fibrin glue chemical pleurodesis had good results with acceptable complications. long term follow-up is necessary to evaluate the accurate effects of treatment and recurrence in a large number of patients.

A Study on the Mechanical Properties of Surface Activated Waste EPDM and The Analysis of Odor Materials (표면 활성화된 폐 EPDM 분말의 물성과 냄새 성분 분석 연구)

  • Choi, J.;Kim, S.;Chung, K.;Chung, J.;Yoo, T.;Yang, J.
    • Elastomers and Composites
    • /
    • v.42 no.4
    • /
    • pp.249-258
    • /
    • 2007
  • In this study, the EPDM powder which was surface activated by high temperature and shear pulverization process was prepared and the mechanical properties and odor material analysis were investigated. Analysis for particle size and size distribution of waste of the EPDM powder has been performed. The waste EPDMs used in this study were 4 types of solid, sponge, solid+sponge, and solid+metal. According to the results, the solid type showed the smallest particle size among the 4 types of EPDM powder. Effective surface devulcanization of EPDM powder could be obtained by the addition of the reclaiming agent. The dicumyl peroxide was considered as the best crosslink agent for dynamic vulcanization when the surface activated EPDM powder was blended with polyolefin in order to make TPE. Also, the optimum amounts of DCP was 6 phr in terms of surface crosslink reaction and mechanical properties of EPDM powder. The processes of water adsorption and rose oil addition were employed to remove the odor of EPDM powder caused by reclaiming agent. The GC/MS was used to analyze the odor compounds.

산화철 폐촉매를 사용한 NiZn-페라이트웨 합성 및 자기적 특성

  • Park, Sang-Il;Hwang, Yeon;Lee, Hyo-Sook
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2003.05a
    • /
    • pp.26-26
    • /
    • 2003
  • 산업 폐기물로서 전량 매립되고 있는 styrene monomer (SM) 공정에서 발생되는 산화철 폐촉매를 사용하여 NiZn-페라이트를 합성하였고, 그 자기적 특성을 조사하였다. 평균입경 0.5㎛로 미분쇄된 산화철 폐촉매에 NiO 및 ZnO를 혼합하여 900℃에서 하소한후 1230℃에서 5시간 동안 소결하여 스핀넬형 페라이트 소결체를 얻었다. Ni/sub x/Zn/ub 1-x/Fe₂O₄(x=0.36, 0.50, 0.66) 및 (Ni/sub 0.5/Zn/sub 0.5/)/sub 1-y/Fe/sub 2+y/O₄(y=-0.02, 0, 0.02) 조성에 대하여 초투자율을 측정하였다. S-parameter를 측정하여 반사 감쇄량을 계산하였다. Ni/sub 0.5/Zn/sub 0.5/fe₂O₄ 조성의 경우 밀도 5.38 g/㎤ kHz에서의 초투자율이 59인 특성을 얻었다. 산화철 폐촉매를 이용하여 X-band 주파수 영역에서 높은 전자파 흡수능을 갖는 전파흡수체를 제조할 수 있음을 확인하였다. Ni/sub 0.5/Zn/sub 0.5/Fe₂O₄ 조성에 대하여 1100℃에서 하소한 분말을 사용하여 실리콘 고무에 복합시킨 후 전파흡수능을 측정하였다. 폐촉매에는 산화철 이외에 CeO₂가 주된 첨가물로 함유되어 있어서 페라이트의 합성 후에도 2차상으로서 존재하였다. 출발 원료인 산화철 폐촉매에 존재하는 K₂O 및 CeO₂를 제거하기 위하여 산처리와 분산제를 이용한 CeO₂ 분리과정을 행하였다. 정제된 산화철 폐촉매에 NiO 및 ZnO를 혼합하여 900℃에서 하소하여 스핀넬형 페라이트를 합성하고 1325℃에서 5시간 소결하였다. 위와 마찬가지로 Ni/sub x/Zn/sub 1-x/Fe₂O₄(x=0.36, 0.50, 0.66)과 (Ni/sub 0.5/Zn/sub 0.5/)/sub 1-y/Fe/sub 2+y/O₄(y=-0.02, 0, 0.02) 조성에 대하여 자기적 특성을 조사하였다.화된 중성자빔으로 측정하였다 BPC-Si를 구부려 슬랩의 곡률반경을 변화시키면서 단색기-시료-검출기가 평행파 반평행배치일 때 Cu(111), (200), (220), (311), (331), (420)면의 회절선을 측정하여 각 조건에서 분해능과 강도를 평가하였다.료의 가시적 변화를 통해 illumination angle 1.25mrad(Dose rate : 334 × 10³ e/sup -//sec·n㎡)일 경우 약 3초 이내에 비정질화가 시작됨을 알 수 있었고 이는 약 1 × 10/sup 6/ e/sup -//sec·n㎡ 의 전자선량에 해당되며 이를 기준으로 각각의 illumination angle에 대한 임계전자선량을 평가할 수 있었다. 실질적으로 Cibbsite와 같은 무기수화물의 직접가열실험 시 전자빔 조사에 의해 야기되는 상전이 영향을 배제하고 실험을 수행하려면 illumination angle 0.2mrad (Dose rate : 8000 e/sup -//sec·n㎡)이하로 관찰하고 기록되어야 함을 본 자료로부터 알 수 있었다.운동횟수에 의한 영향으로써 운동시간을 1일 6시간으로 설정하여, 운동횟수를 결정하기 위하여 오전, 오후에 각 3시간씩 운동시키는 방법과 오전부터 6시간동안 운동시키는 두 방법을 이용하여 품질을 비교하였다. 각 조건에 따라 운동시킨 참돔의 수분함량을 나타낸 것으로, 2회(오전 3시간, 오후 3시간)에 나누어서 운동시키기 위한 육의 수분함량은 73.37±2.02%를 나타냈으며, 1회(6시간 운동)운동시키기 위한 육은 71.74±1.66%을 나타내었다. 각각의 운동조건에서 양식된 참돔은 사육초기에는 큰 변화가 없었으나, 사육 5일 이후에는 수분함량이 증가하여 15일에는 76.40±0.14, 75.62±0.98%의 수분함량을 2회와 1회 운동시킨 참돔의 육에서 각각 나타났다. 운동횟수에 따른 지질함량은 2회 운동시킨 참돔은 5.83±2.08, 1회 운

  • PDF

The Microbiological Evaluation of Environments and Facilities at Food Service Operations in Elementary School (초등학교 단체급식 소의 환경과 급식설비에 대한 미생물 평가)

  • 정동관;류은순
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.2
    • /
    • pp.216-220
    • /
    • 2002
  • The microbiological examinations of food service operations were conducted for the hygienic evaluation at four elementary schools in Busan, Korea. Total one hundred and seventy two swabbed samples using sponge were collected from the surface of environments, utensils and equipments of food service facilities and analyzed by measuring the total, coliform and psychrotrophic count. Sampling sites were the surfaces of floors, drains, walls, knives, cutting boards, rubber gloves, vinyl aprons, plastic containers, carriers, shelves, trays, dry shelves, electric tray dryer, food containers, soup containers, rice cookers, frying pans, boiling cookers, refrigerators, dumb waiters and dishwashers. The swabbed samples kept in an ice-parked box were transported to a laboratory and analyzed. The results demonstrated that the degree of contamination depended on the sampling sites. Averages of total counts of surface swab samples were ranged from 0.62 to 7.79 Log CFU/200 cm$^2$. The level of coliforms were ranged from not detectable to 5.26 Log CFU/200 cm$^2$, and those of psychrotrophs from not detectable to 6.15 Log CFU/200 cm$^2$. The severely contaminated sites were dumb waiters, drains, rice cookers, knives, plastic containers and floors. Also cutting boards, rubber gloves, carriers, drying shelves, vinyl aprons, boiling cookers, soup containers, frying pans and refrigerators were highly contaminated with the level of abode 3.5 Log CFU/200 cm$^2$. Therefore, those sites should be focused and controlled according to control points of sanitation standard operating procedures (SSOP). Also, periodic microbiological examination in addition to visual examination is recommended on these highly contaminated sites indicated above results at food service operations in elementary school.