• Title/Summary/Keyword: 고도처리공정

Search Result 269, Processing Time 0.024 seconds

Advanced Treatment of Shipboard Sewage by RCM Process with BM (복합미생물제제를 이용한 RCM공법의 선박오수 처리장치 적용에 관한 연구)

  • Ha, Shin-Young;Kim, In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.38 no.5
    • /
    • pp.451-456
    • /
    • 2014
  • Lab scale experiment was carried out to study biological wastewater treatment technology developed for shipboard. RCM process using BM(Beneficial Microorganisms) was investigated for practical application on shipboard sewage treatment. RCM process is an environmental friendly treatment system, with minimum production of sludge. In the test, BOD5, CODcr, T-N and T-P were reduced a 96%, 97%, 78% and 81.68% respectively. From the result it was suggested that RCM process with BM might be a suitable process for shipboard sewage treatment, maintenance of useful microorganisms and creating special environment as the SDC tank is circulating in the non-biodegradable organics sludge generated during the wastewater treatment, thus reducing the amount of sludge generated. Therefore, the RCM process does not require additional equipment to strengthen it to meet the marine pollution standards.

The Study of Modified Sequencing Batch Reactor Process for Small Advanced Wastewater Treatment (소규모 고도하수처리를 위한 변형 연속회분식공정에 관한 연구)

  • Han, Woonwoo;Kim, Kyuhyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.35-43
    • /
    • 2008
  • This study was carried out to estimate the performance of modified sequencing batch reactor (SBR) process by the application of SBR process for small advanced wastewater treatment plant. Organic, nitrogen and phosphorus were able to remove in the unit reactor by SBR process and it would be able to select the suitable operation method. The plant was operated to achieve high performance with influent control, optimum anoxic/oxic condition using intermediate aeration method, and solid (sludge) /liquid (effluent) separation by modified decanter. The optimum operating mode was 3Cycles a day and intermediate input and aeration. Under these conditions, the treatment efficiencies were good with 60% of designed flow rate and low influent quality. When the influent concentrations of BOD and CODMn were 120.4 mg/L and 95.7 mg/L, respectively. The effluent concentrations of BOD and CODMn were 6.8 mg/L and 11.0 mg/L, respectively. The average removal efficiencies of BOD and CODMn were 94.4% and 88.5%, respectively. The removal efficiencies of T-N and T-P were 69.6% and 73.6%, respectively when the average T-N and T-P concentrations were 32.2mg/L and 4.65mg/L, respectively. The T-N and T-P removal efficiencies were slightly decreased to 58.8% and 68.5%, respectively in the winter season but its were also stable efficiencies. BOD, T-N and T-P were removed by 90%. 67% and 46% respectively in the first anoxic/oxic condition, in addition to T-P was removed by 70% in the second anoxic/oxic condition. From the results, modified sequencing batch reactor (SBR) process is suitable for small advanced wastewater treatment.

  • PDF

Taeyoung Submerged-type Membrane Filtration for Advanced Drinking Water Treatment (태영 침지식 막여과 고도정수처리)

  • Yeon, Kyeongho;Cho, Jaebeom;Lee, Yunkyu;Kang, Hojung;Kim, Woogu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.4
    • /
    • pp.15-27
    • /
    • 2013
  • In order to plan out the Daegu G membrane filtration water treatment plant, water quantity, water quality and process stability were evaluated using the field pilot-scale tests, during the six months of continuous operation, including low water temperature period. The field model experiments, which were carried out according to the Installation Criteria of Ministry of Environment, consisted of two series : series 1 - water quality verification, and series 2 - membrane process evaluation. The process water quality met all drinking water standards with less than 0.03 NTU. Moreover, process operation showed a stable membrane pressure with 99% of recovery ratio. This shows that the tests were properly designed in terms of the influence of water loading and temperature. In conclusion, the purpose of this study is to establish core technology for advanced drinking water treatment, through on-going accumulation of engineering and construction know-how.

Treatment Efficiency and Organic Matter Characterization of Wastewater through Activated Sludge Process and Advanced Wastewater Treatment Process (활성슬러지공정과 고도처리공정에 따른 하수처리수의 처리효율과 유기물 특성)

  • Hong, JiHea;Sohn, Jinsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.807-813
    • /
    • 2004
  • Wastewater was treated by two different treatment processes; activated sludge process and advanced wastewater treatment process (KNR process) using lab-scale experiment. Two treated wastewater showed good treatment efficiency of organic matter removal, up to 90% removal. Nitrogen and phosphorus were not effectively removed though activated sludge process, while KNR process showed good removal efficiency of nitrogen and phosphorus; 56% nitrogen removal and 95% phosphorus removal. KNR process showed better removal efficiency of organic matter, nitrogen, and phosphorus compared to activated sludge process. Organic matter characterization was tracked though measurement of UV scan, SUVA, and XAD fractionation. Treated wastewater showed higher SUVA value than wastewater influent, indicting less aromatic characteristic of organic matter. XAD fractionation showed hydrophilic fraction decreased though wastewater treatment, suggesting microbes preferentially digest hydrophilic and aliphatic molecules rather than hydrophobic and aromatic molecules of organic matter.

Design of a Wastewater Treatment Plant Upgrading to Advanced Nutrient Removal Treatment Using Modeling Methodology and Multivariate Statistical Analysis for Process Optimization (하수처리장의 고도처리 upgrading 설계와 공정 최적화를 위한 다변량 통계분석)

  • Kim, MinJeong;Kim, MinHan;Kim, YongSu;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.589-597
    • /
    • 2010
  • Strengthening the regulation standard of biological nutrient in wastewater treatment plant(WWTP), the necessity of repair of WWTP which is operated in conventional activated sludge process to advanced nutrient removal treatment is increased. However, in full-scale wastewater treatment system, it is not easy to fine the optimized operational condition of the advanced nutrient removal treatment through experiment due to the complex response of various influent conditions and operational conditions. Therefore, in this study, an upgrading design of conventional activated sludge process to advanced nutrient removal process using the modeling and simulation method based on activated sludge model(ASMs) is executed. And a design optimization of advanced treatment process using the response surface method(RSM) is carried out for statistical and systematic approach. In addition, for the operational optimization of full-scale WWTP, a correct analysis about kinetic variables of wastewater treatment is necessary. In this study, through partial least square(PLS) analysis which is one of the multivariable statistical analysis methods, a correlation between the kinetic variables of wastewater treatment system is comprehended, and the most effective variables to the advanced treatment operation result is deducted. Through this study, the methodology for upgrading design and operational optimization of advanced treatment process is provided, and an efficient repair of WWTP to advanced treatment can be expected reducing the design time and costs.

Investigation of Treatment Efficiency for Advanced Processes of Water Treatment Plants in Korea (국내 정수장 고도정수처리 공정에서 공정별 처리효율 조사)

  • Mun, Sung-Min;Choi, Suing-Il;Sohn, Jin-Sik;Yoon, Je-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.323-329
    • /
    • 2005
  • Advanced processes such as ozonation or activated carbon filtration (ACF) in water treatment plants have been used in Korea since 1994. At present, seventeen drinking water treatment plants are currently operating. This survey compares the treatment performance of advanced processes in eight plants which have comparable water quality data. The three parameters (DOC, $UV_{254}$, and $KMnO_4$ consumption) of water quality were selected as an indicator of treatment efficiency. The treatment efficiency of ozonation and ACF processes was found to vary with large deviations in each plant. Treatment efficiency of DOC, $UV_{254}$, and $KMnO_4$ consumption by post ozonation ranged from 3 to 11%, 6 to 33%, and 12 to 28% respectively. On the other hand, for ACF, treatment efficiency of DOC, $UV_{254}$, and $KMnO_4$ consumption ranged from 7 to 38%, 8 to 48%, and 16 to 66% respectively. These large deviations indicate the advanced processes of water treatment plants to be further optimized.

Removal of Algogenic Organic Matter in Drinking Water Treatment Process (정수처리공정에서 조류유래 유기물질의 제거)

  • Park, Se-Jin;Cha, Il-Kwon;Yoon, Tai-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.377-384
    • /
    • 2005
  • Algae causes not only the eutrophication of lake, but also the deterioration of drinking water process. Especially, algogenic organic matters(AOM) are assumed as disinfection by-products(DBPs) precursors like humic and fulvic acids. In this study, it was investigated the characteristics changes of algogenic organic matter(AOM) by prechlorination and coagulation treatment. Evaluation of enhanced coagulation and applicability of UV oxidation process were also evaluated as the drinking water treatment system for the eutrophicated water source. prechlorination was effective process for algae removal but caused releasing of dissolved organic matter(DOC) into water due to the destruction of algae's cell. In coagulation treatment with Fe(III) coagulant, reaction pH is an important factor for the removal of AOM and triholomathanes(THMs). At pH 5, removal efficiency of DOC and THMs were dramatically improved by 50% and 28%, respectively, in comparison with the conventional coagulation treatment at about pH 7. Photo-Fenton($UV/H_2O_2/Fe^{3+}$) process among the UV oxidations is the most effective system to remove AOM, but its removal efficiency was lower than that of enhanced coagulation treatment at pH 5.

Technical Feasibility for Hollow-Fiber Ultrafiltration Water Treatment System and its Economic Aspects (중공사형 한외여과막 수처리 공정의 기능성과 막을 사용한 수처리공정의 경제성에 관한 연구)

  • Wang, Jin-Soo;Kim, Byung-Jick;Choi, Soo Hyoung
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.12-18
    • /
    • 1999
  • This research was undertaken to do the technical and economical feasibility study of membrane water treatment system. For the technical feasibility study, batch water treatment system using UF(ultrafiltration) was set up and several experiments were carried out. The performance of the UF membrane was tested in terms of turbidity. The experimental results showed that the UF membrane process produced less than 1 NTU water regardless of input water turbidity. For the economical feasibility study, the cost model was analyzed and programmed for simulation. Also costs of the membrane water treatment and the conventional treatment were evaluated. The simulation results showed that the unit production cost increased when design flow or permeate flow decreased. The production cost of membrane water treatment system was lower than that of the conventional system. Both technical and economical feasibility study showed that the UF membrane water purification system was a very competitive water purification process.

  • PDF

Variation of Pollutant Removal Efficiency and Backwashing Effect of BAC Basin in Advanced Water Treatment Processes (고도정수공정에서 오염물질 제거효율 변화특성과 BAC조의 역세척에 따른 영향)

  • Park, Soo-Yee;Lee, Sang-Bong;Sin, Sang-Min;Jun, Chang-Jea;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.45-53
    • /
    • 2008
  • In this paper, the property of influent water and variations of removal efficiencies in each unit processes were studied based on the experiment data from the advanced water treatment plant in a city of Korea. The microbial species in the biological activated carbon(BAC) after backwashing of activated carbon filtration tank(ACFT) were also identified. The property and the removal efficiencies were evaluated by considering 8-9 items. The variations of 4 items were investigated from the influent and effluent of ACFT. SEM recording were conducted on BAC samples before and after backwashing. And the existence of attached microorganisms were identified through HPC(Heterotrophic Plate Counter) investigation. For the property of influent water, the concentrations of most items were maintained in the constant ranges, some items had seasonal properties. For the removal efficiencies, there were some items showing similar monthly-pattern and increasing with time, other items decreasing at the ozone contactor. Through these investigations, it was possible to distinguish the target items, which were removed by the advanced processes. The existence of microorganisms in ACFT could be predicted based on the variation curve of NH$_3$-N, and this fact were proved by SEM and HPC.

A Study on the Highly Effective Treatment of Spent Electroless Nickel Plating Solution by an Advanced Oxidation Process (고도산화공정을 이용한 고농도 무전해 니켈도금 폐액 처리방안 연구)

  • Seo, Minhye;Cho, Sungsu;Lee, Sooyoung;Kim, Jinho;Kang, Yong-Ho;Uhm, Sunghyun
    • Applied Chemistry for Engineering
    • /
    • v.26 no.3
    • /
    • pp.270-274
    • /
    • 2015
  • We develop advanced oxidation processes for the treatment of spent electroless nickel plating solution. Apart form recovering nickel by leaching and enrichment, more emphasis is placed on rendering the waste water recyclable via oxidizing phosphite and hypophosphite into phosphate which can then be precipitated easily. $UV/H_2O_2$ process is employed and the conversion efficiency of COD and $PO_4-P$, and $H_2O_2$ consumption are analyzed. Furthermore, the $UV/H_2O_2/O_3$ process in conjunction with $O_3$ generator enables us to not only save the treatment time by 6 hours but also reduce $H_2O_2$ consumption by 30%.